Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAdmitted-Finance | ₹6.5 L | L1 | Admitted-Finance |
| 2 | L2₹6.7 L+₹18,158.31 (2.78%)Admitted-Finance | ₹6.7 L+₹18,158.31 (2.78%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical EMD not deposit |
| 4 | Rejected-Technical | - | - | Rejected-Technical EMD not deposit |
| 5 | Rejected-Technical | - | - | Rejected-Technical EMD not deposit |
| Sl No | Description | Qty | Unit | ARIHANT ENGINEERS AND TRADERS L1 | Shiva Buildtech L2 |
|---|---|---|---|---|---|
| 1.01 | S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as reqd. 1 or 2 modules DSR 2022 1.27.1 | 4 | Nos | 1,180 ₹1,180 Lowest | 1,200 ₹1,200 |
| 1.02 | 6 module DSR 2022 1.27.4 | 10 | Nos. | 3,980 ₹3,980 Lowest | 4,050 ₹4,050 |
| 1.03 | S/F of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including ,painting etc DSR 2022 1.57 | 6 | Nos. | 4,320 ₹4,320 Lowest | 4,380 ₹4,380 |
| 1.04 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 2.5 sqmm DSR 2022 1.17.12 | 145 | mtrs | 19,720 ₹19,720 Lowest | 20,300 ₹20,300 |
| 1.05 | 3 x 4 sqmm DSR 2022 1.17.21 | 220 | mtrs | 44,880 ₹44,880 Lowest | 46,200 ₹46,200 |
| 1.06 | 3 x 6 sqmm DSR 2022 1.17.30 | 170 | mtrs | 51,170 ₹51,170 Lowest | 52,700 ₹52,700 |
| 1.07 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. 2 x 10 + 1 x 6 sqmm earth wire. DSR 2022 1.14.5 | 35 | mtrs | 21,283.15 ₹21,283.15 Lowest | 21,630 ₹21,630 |
| 1.08 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B DSR 2022 1.10.2 | 22 | Nos. | 25,740 ₹25,740 Lowest | 26,070 ₹26,070 |
| 1.09 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch DSR 2022 1.24.1 | 12 | Nos. | 1,224 ₹1,224 Lowest | 1,260 ₹1,260 |
| 1.10 | 3 pin 5/6 amp socket outlet DSR 2022 1.24.4 | 8 | Nos. | 968 ₹968 Lowest | 1,000 ₹1,000 |
Tender Value
Refer Docs
EMD Value
₹13,200
Closing Date
3 Jul 2026, 11:15 amClosed
Executive Engineer (EnM) M-8
Office of the Executive Engineer (EnM) M-8 Nangloi Phase-III, Near Maharaja Surajmal Stadium Metro Station New Delhi-110041.
Electrification of Sewer Store, Q Block Mangolpuri AC-12
2026_DJB_294416_1
NIT No.04 /EE(EnM)M-8/2026-27 Item 11
Open Tender
Civil Works
Works
30 days
Nangloi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹13,200
Yes
16 Jul 2026
25 Jun 2026
3 Jul 2026
25 Jun 2026
3 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as reqd. 1 or 2 modules DSR 2022 1.27.1 | 4 | Nos | 80 | ₹320 |
| 1.02 | 6 module DSR 2022 1.27.4 | 10 | Nos. | 80 | ₹800 |
| 1.03 | S/F of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including ,painting etc DSR 2022 1.57 | 6 | Nos. | - | - |
| 1.04 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 2.5 sqmm DSR 2022 1.17.12 | 145 | mtrs | - | - |
| 1.05 | 3 x 4 sqmm DSR 2022 1.17.21 | 220 | mtrs | - | - |
| 1.06 | 3 x 6 sqmm DSR 2022 1.17.30 | 170 | mtrs | - | - |
| 1.07 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. 2 x 10 + 1 x 6 sqmm earth wire. DSR 2022 1.14.5 | 35 | mtrs | - | - |
| 1.08 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B DSR 2022 1.10.2 | 22 | Nos. | - | - |
| 1.09 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch DSR 2022 1.24.1 | 12 | Nos. | - | - |
| 1.1 | 3 pin 5/6 amp socket outlet DSR 2022 1.24.4 | 8 | Nos. | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_391427.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .