Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC 22 1755A KANNANKATTU TEMPLE ROAD EDAKOCHI KOCHI 682010 ERNAKULAM KERALA 682010 | ERNAKULAM | KERALA | 682010 | L1 | Accepted-AOC 1st Lowest and Reasonable | |
| 2 | L2₹9.4 L+₹1,270 (0.14%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹9.7 L+₹30,144.86 (3.22%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest | |
| 4 | L4₹10.8 L+₹1.5 L (15.6%)Rejected-Finance | L4 | Rejected-Finance 4th lowest | |
| 5 | L5₹12.0 L+₹2.6 L (28.2%)Rejected-Finance | L5 | Rejected-Finance 5th Lowest |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
20 Feb 2024, 6:00 pmClosed
CWE Mhow
HQ CWE MHOW, Mhow Cantt Mhow M.P-453441
REPAIR/MAINT OF STP AND OTHER CONNECTED WORKS INSTALLED AT VARIOUS LOCATIONS OF AGE E/M -1 UNDER GE (MIS) MHOW.
2024_MES_637989_1
CWE/MHOW/25 (T) of 2023-24
Open Tender
Civil Works
Item Rate
180 days
HQ CWE Mhow
As per tender documents
8 documents required · 8 mandatory
₹500
GE (M) Inf School Mhow
₹27,000
1 Mar 2024
18 Jan 2024
22 Feb 2024
18 Jan 2024
20 Feb 2024
6 Feb 2024
Amount
Repair and overhauling including dismantling / taking down all electrical and mechanical connection of Air blower including motor installed at STP and servicing hole body, change gear oil/ lubricant and V belt, overhauling and testing including painting of complete body and air outlets complete all as specified and directed.Spares and gear oil/ lubricants in adequate qty for one Air Blower should be provide by the contractor and the rate for the same shall deemed to be included in the quoted rates:- (a) Servo Gear oil Super 90 - 5 Ltrs (b) Bearing for Air blower and motor as per sample -1 (c) Oil Seal as per existing size -1 (d) Gasket Kit as per existing size -1 (e) Oil Seal As per existing size -1 (f) V Belt as per existing size -1 (g) Air filter as per existing size -1
Dewatering the equalisation tank with the help of mud pump and removal of complete sludge and cleaning inside, descaling internal surface of tank with wire brush and scraper, washing with fresh water two times with bleaching powdercomplete all as specified and directedby Engr-in-Charge. Note :- (a) Making temporary arrangement for pumping out the raw sewage effluent from manhole near the equalisation tank to a distance of appx 100 mtrs from the STP during cleaning period of equalisation tank, cost incurred is deemed to be included the quoted rates. (b) While cleaning the tank contractor shall ensure necessary safety precautions and to arrange safety mask, Hand Gloves etc. (c) Arrangement for sludge pump to pump out the settled sludge in equalisation tank and manhole is to borne by the contractor , cost incurred is deemed to be inclusive in the quoted rate.
M&L for dewatering with the help of Mud Pump and manning for cleaning of MBBR Tanks of compartments of STP of capacity 230 KLD installed at PW Div and removing all the settled solid sludge or any other type of material and applying two coat water proof anti corresive enemel paint through brush/ spray gun inside and out side the tank and through out side for a minimum distance of 100 Mtrs from STP complete all as specified and directed by Engr-in-Charge.
M&L for dewatering with the help of Mud Pump and manning for cleaning of MBBR Tanks of compartments of STP of capacity 120 KLD installed at MH Mhow and removing all the settled solid sludge or any other type of material applying two coat water proof anti corresive enemel paint through brush/ spray gun inside and out side the tank and through out side for a minimum distance of 100 Mtrs from STP complete all as specified and directed by Engr-in-Charge.
M&L for dewatering with the help of Mud Pump and manning for cleaning of MBBR Tanks of compartments of STP of capacity 300 KLD installed at HP Enclive and removing all the settled solid sludge or any other type of material applying two coat distemper paint through brush/ spray gun inside and out side the tank and through out side for a minimum distance of 100 Mtrs from STP complete all as specified and directed by Engr-in-Charge.
M&L for dewatering with the help of Mud Pump and manning for cleaning of Tube settler Tank of STP of Capacity 300KLD installed HP Encluve removing all the settled deposited Sludge/ fungus or other type of Bio fouling and cleaning inside, descaling internal surface of tank with wire brush and scraper, washing with fresh water two times with bleaching powder applying the two coat anti corrosive water proof enmel paint with brush /spray gunall complete all as specified and directed by Engr-in-Charge
M&L for dewatering with the help of Mud Pump and manning for cleaning of Tube settler Tank of STP of Capacity 230 KLD installed at PW Div removing all the settled deposited Sludge/ fungus or other type of Bio fouling and cleaning inside, descaling internal surface of tank with wire brush and scraper, washing with fresh water two times with bleaching powder and applying the two coat anti corrosive water proof enamel paint with brush /spray gun complete all as specified and directed by Engr-in-Charge
M&L for dewatering with the help of Mud Pump and manning for cleaning of Tube settler Tank of STP of Capacity 120 KLD installed at MH Mhow and removing all the settled deposited Sludge/ fungus or other type of Bio fouling and cleaning inside, descaling internal surface of tank with wire brush and scraper, washing and welding inside the tank were required and applying the two coat anti corrosive water proof enamel paint with brush /spray gun after that fresh water two times with bleaching powder complete all as specified and directed by Engr-in-Charge.
Removing the dry sludge from the sludge drying bed, further drying, loading to a suitable transport and transporting for disposing regularly during period of operation complete all as specified and directed by the Engr in charge. (Note:-For 120M3/Day 230 M3/Day& 300m3/Day)
Testing of treated water sample, once in every three month by sending the water samples to the authorised laboratories for the following parameters:- (Note:-For 120 M3/Day ,300 M3/Day & 230 M3/Day) a) PH : 5.5 to 9.0 (SPCB Limit) b) BOD: 10 mg/L Maximum (SPCB Limit) c) Turbidity : 5 NTU Maximum (SPCB Limit) d) Total Suspended solids : 30 mg/L Maximum (SPCB Limit) e) Residual chlorine: 1.0 mg/L Maximum (SPCB Limit) f) E. Coli: Nil CFU (SPCB Limit)
Supply and mix bleaching powder grade-I, ISI marked having stable available chlorine % by mass minimum 35% as per IS 1065-1971 with water as directed by Engineer in charge and pouring into dosing plant system complete all as specified and directed. Make : Vikram. Note: Bleaching powder shall be packed and supplied in 25 Kg bag
Supply and mix aluminium chloride in powder form, grade basicity with water as directed and pouring into dosing plant system for purification of water complete all as specified and directed. Make : Vikram.
Supply and mix sodium Hypochloride solution with water as directed and pouring into dosing plant system complete all as specified and directed.
Dismantling the electric induction motor 415 volts AC 3 Phase, capacity 5 to 7 HP, 440 V, 50Cycle of any make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair/rewinding, strip opening the motor and removing of defective burnt winding, ball bearing, bush, rewinding the motor after cleaning the rotor and stator with super enamelled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing ball bearing, bush, all high grade material and class ‘B’ varnish for insulation & replacing the u/s nuts, bolts, washers of appropriate size and reassembling the complete motor and re-fixing, proper alignment, coupling with pump including connecting the existing electric cable connection, earthing, and testing the motor on full load up to entire satisfaction of Engineer-in-charge complete all as specified and directed Note :- (i) Super enamelled copper winding wire shall be measured and paid separately under appropriate item of this DCS in supply only. (ii) The T & P/ vehicles will be arranged by the contractor and the cost deemed to be included in the quoted rates.
All as per Item No. 14 above but electric motor of capacity upto 2HP complete all as specified and as directed by Engineer-in-charge
Supply only in repair, Super enamelled copper winding wire for rewinding the electric motors Note:- Labour for motor winding shall be measured and paid separately under appropriate item of this BOQ.
M&L for MBBR media made out of poly propylene with virgin plastic, UV stabilised of specific gravity 0.95 to 0.98 complete all as specified and directed
M&L in replacement of tube settler modules made of PVC complete all as specified and as directed.
M&L for Dismantling and taking down the complete pipe line of STP's for descaling including painting the outer surface of pipe and refixing the same and testing for leaks and replacing the complete nuts, bolts, washers and rubber gaskets etc complete all as specified and as directed.
M&L for replacement of fine coreus sand filter media and cleaning of PSF tank including taking out old media out side for a minimum distance of 100 Mtrs from STP complete all as specified and directed
M&L for replacement of carbon filter media and cleaning of ACF tank including taking out old media out side for a minimum distance of 100 Mtrs from STP complete all as specified and directed by Engr-in-Charge.
M&L for Pressure gauge, analogue type of range up to 22 kg/sq.cm including taking down the existing unserviceable pressure gauge complete all as specified and directed
M&L for Writing letters or figures (Block, Roman, Italic or Indian) not exceeding 15cm height with white synthetic enamel paint over a coat of black colour paint complete all as specified and directed. PER 10 NOS (PER CM OF HEIGHT)
Repair/overhauling/ maintenance to chlorination dozing plants sodium hypo chlorite solution type of any make & model, including replacement of unserviceable motor, repairs to pump and replacement of injection check valve, 3/8'' white suction/discharge tubing & fixing new injection check valve, 3/8'' white suction/discharge tubing etc. for complete serviceability of systems, complete all as specified and directed by Engineer-in-charge.
Supply only of liquid end spare (a) Non return valve
(b) LDPE Pipe
(c) Discharge valve
(d) diaphragm
(e) suction valve
(f) coupling nut
(g) foot valve assembly
(h) NRV spring
(j) Ring seal
(k) ball (ceramic)
(l) pressure relief valve
(m) '' y'' type strainer
(n) head
Drive end spare (o) spacer
(p) spacer gasket
(q) spring
(r) spring plate
(s) ball bearing
(t) motor gasket
(u) gear plate
(v) mounting base
S&F in repair FRP type solution preparation cum settling tank of capacity 100 ltrs with level guage, lid,inlet/outlet,drain connection and fitted with speed reducer,motor and SS/PVC agitator complete all as specified and directed by Eng-in-charge
M&L for cleaning of Raw water collection chember with help of manning for removing sludge/oil/grease from screening bar chember, raw water tank, oil and grease removal chember complete all as specified and directed.
M&L for Dismantling mono block/centrifugal pump set motor from the existing foundation after disconnecting the inlet / out let pipe connections, disconnecting electrically and taking to civil authorised KIRLOSKAR dealer workshop for repair/strip opening and repairing of pumping sets by replacement the worn out defective/unserviceable parts such as bearing, bush, gland rope, check nut, shaft sleeves etc. complete. Reassembling including oiling, greasing replacement of worn out nuts, bolts, gasket etc, and re-fixing in its original position at site, making all connections, commissioning and testing for smooth and noise free operation including bringing back the same from workshop after necessary servicing and testing the same after proper mounting/refixing for entire satisfaction of Engr - in - Charge complete all as specified and directed of capacity 5 HP.
M&L for disconnecting/ removing the defective starter from the LT panel board and Supply & fixing new CosmicStar-Reversing Starter 415 volts 3 phase with single phase protection feature with overload relay range 7 to 10 Amp and Contactors suitable for 5 HP electric motor at the existing panel board in position and making electric connections complete all as specified and directed by Engr-in-Charge.
S & F in replacement XLPE insulated and PVC armoured heavy duty electric cables with aluminum conductor, 1100 volt grade of size 2 core 10 sqmm in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with suitable size aluminum lugs and testing complete all as specified & directed for the following sizes:- Note : (a) Excavation shall be measured and paid seperately under respective items of Sch 'A' (b) All redq lugs of suitable sizes according to laying of cable measured and paid seperately under respective items of Sch 'A'
All as per Item No.50 but 16 Sqmm 4 core.
Supply and fixing in replacement for LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
Supply and fixing in replacement for LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in any type of soil for foundation, laying pipe etc. or for shafts, wells, cesspits, manholes, pier holes, etc. and getting out complete all as specified and directed.
Returning filling in soft/loose soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing excavated material (Soils) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
Taking up or down existing GI tubing and connections including cleaning for refixing or removal to store for following size of pipes complete all as specified and directed :- (a) 100 mm bore
(b) 80 mm bore
( c) 50 mm bore
Supply, fixing, laying & jointing in repair galvanised iron water tubes 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, check nuts, caps, plugs etc.and clips, wall hooks etc. laid in trenches, on ground or fixing on wall and testing complete all as specified and directed of following sizes: - (a) 80 mm bore
(b) 50 mm bore
Supply & fixing laying and jointing in repair of PVC /ASTM pipe with all necessary fittings complete all as specified and directed.
M& L in repair of sprinklers head with tripod stand with accessories connecting assembly complete all as specified and directed.
M & L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strep 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia light grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board as indicated including testing complete all as specified and directed.
Ankit construction
NEERAJ DUBEY
Vinayak Trading House
MODI CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .