Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical RG METRO ARCADE SECTOR 11 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | Accepted-Technical Fulfilled the required criteria |
| 2 | Accepted-Technical | Accepted-Technical Fulfilled the required criteria |
| 3 | Accepted-Technical | Accepted-Technical Fulfilled the required criteria |
| 4 | Accepted-Technical SHOP NO 02 RAMCHAND APARTMENT MAKHMALABAD NAKA PANCHAVATI NASHIK MAHARASHTRA | NASHIK | NASHIK | MAHARASHTRA | 422003 | Accepted-Technical Fulfilled the required criteria |
| 5 | Accepted-Technical 807 PEARL BUSINESS PARK NETAJI SUBHASH PLACE PITAMPURA DELHI | DELHI | DELHI | Accepted-Technical Fulfilled the required criteria |
Tender Value
₹141.5 Cr
EMD Value
₹2 Cr
Closing Date
6 Mar 2023, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, Circle Office, UPJN(R), Varanasi
Office of the Superintending Engineer, Circle Office, Madhopur, Sigra, U P Jal Nigam (Rural), Varanasi
Construction of 55 MLD STP at Bhagwanpur to cater additional flow of Assi Drain along with apputenant works in Varanasi on DBOT mode under Namami Gange Program.
2023_UPJNG_769335_1
32/W-NMG/08 dt 18.01.2023
Open Tender
Civil Works - Others
Turn-key
547 days
Varanasi
As per Bid Document
2 documents required · 2 mandatory
₹23,600
PM GPPU UPJN(R) Varanasi
₹2 Cr
Varanasi
23 May 2023
25 Jan 2023
6 Mar 2023
25 Jan 2023
6 Mar 2023
8 Feb 2023
30 Jan 2023
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 55 MLD STP and Appurtenant Works | - | - | - | - |
| 2 | Nalla Tapping Arrangement:Survey, design and construction of suitable size R.C.C. (M-30) Nala tapping structure(weir) at Assi Drain with RCC M-30 River Training works at upstream and downstream of tapping point upto suitable length and installation of two number Stainless Steel sluice gates to regulate the flow along with construction of inlet channel and installation of stainless steel coarse screen and proper arrangement for operating platform. | 1 | Job | - | - |
| 3 | Sewage Pumping Stations | - | - | - | - |
| 4 | MPS after dismantelling existing defunct MPS: Design and construction of main pumping station of 50 MLD capacity including construction of Sump well , receiving chamber, screen chamber, Pump house, Panel room, DG/Transformer yard, Panel & PLC Room Boundary wall, RCC retaining wall on two sides along Assi Drain, internal road, site development works along with supply, installation and commissioning of suitable capacity non-clog submersible pumps (MOC- Casing- 2%NiCI, Impeller- ASTM CF8M, Shaft & Shaft sleeve- ASTM SS 410) capable of pumping 100 mm particle with necessary accesseries such as motors, panals, cabeling, valves, pipings etc, D.G. set of suitable capacity with necessary accessaries, one no. Electromagnetic Flowmeter cum totalizer having charecteristics/MOC: Liner: Polyurethane or Hard Rubber / Electrode MOC: SS316L /Housing : Die Cast Aluminium or CS /Power Supply: 90-230 V AC / Output: 4-20mA with HART / Sensor Cable : 10 mt / Flow Tube or Sensor housing protection IP68 / Process Flange : SS316 / Display : 3 1/2 LCD Display / Cable Connection : 1/2"NPT /Accuracy : 0.5%, Automation of MPS, two nos Mechanical screens, one no. Manual screen, two nos. Transformers and Substation, provision for supply and installation of 5T capacity chain pulley block with traveling trolley with 15 meter lift with girder etc with necessary tools and spares, provision for testing of each pump set, valves etc. at manufacturer works and at site, painting of all pumps piping and valves with two coat enamel paint, supply and installation of AMF panel with associated works, supply and installation of actuated sluice gates with associated works etc. including Installation, commissioning and testing of all E&M equipments complete to the satisfaction of engineer in charge. Civils component of the MPS shall be designed for 68 MLD capacity. | 1 | No. | - | - |
| 5 | IPS at Nakkha Nalla:Design and construction of main pumping station of capacity 5 MLD including construction of I&D arrangement of Nakkha Drain, Sump well , receiving chamber, screen chamber, Pump house, Pannel room, DG/Transformer yard, RCC Retaining wall, RCC approach upto IPS along with supply, installation and commissioning of suitable capacity non-clog submersible pumps (MOC- Casing- 2%NiCI, Impeller- ASTM CF8M, Shaft & Shaft sleeve- ASTM SS 410) with necessary accesseries such as motors, panals, cabeling, valves, pipings etc, one no. D.G. set of suitable capacity with necessary accessaries, one no. Electromagnetic Flowmeter cum totalizer having charecteristics/MOC: Liner: Polyurethane or Hard Rubber / Electrode MOC: SS316L /Housing : Die Cast Aluminium or CS /Power Supply: 90-230 V AC / Output: 4-20mA with HART / Sensor Cable : 10 mt / Flow Tube or Sensor housing protection IP68 / Process Flange : SS316 / Display : 3 1/2 LCD Display / Cable Connection : 1/2"NPT /Accuracy : 0.5%, Automation of MPS, two nos Mechanical screens, one no. Manual screen, two nos. Transformers and Substation, provision for supply and installation of required capacity chain pulley block with traveling trolley with 15 meter lift with girder etc with necessary tools and spares, provision for testing of each pump set, valves etc. at manufacturer works and at site, painting of all pumps piping and valves with two coat enamel paint, supply and installation of AMF panel with associated works, supply and installation of actuated sluice gates with associated works etc. including Installation, commissioning and testing of all E&M equipments complete to the satisfaction of engineer in charge. Civil component of the MPS shall be designed for 6 MLD capacity. | 1 | No. | - | - |
| 6 | Rising Main | - | - | - | - |
| 7 | Rising main from MPS to STP: Design, Supply and laying of 900 mm diameter DI K-9 pipe Pressure Pipes (S&S) with out side Zinc coating with finishing layer of Bitumen and have factory internal cement mortar lining in SRC cement for sewerage confirming to IS 8329:2000 (amended upto date) with push on type EPDM 'ISI marked' rubber gasket (including cost of rubber gasket) joining as per IS 5382 specifications with hydraulic field testing, commissioning as per specifications, providing, Erecting, Testing, Commissioning of C.I. double ball orifice type Air Valve, construction of air valve chamber as per type design including supply & fixing of 500 mm dia medium duty perforated C.I. cover, Providing, Erecting, Testing, Commissioning, of Scour/Drain Valve with construction of chambers including dismantellin & restoration of road, excavation by manually or mechanically in inordinary soil (earth, sand, loam & clay) including ramming dressing, leveling by manually or mechanically, refilling of trenches in 15cm layer watering and ramming the same including removal of surplus earth or other dismantled material upto a distance of 500 m from the centre of trenches/trenchless technology, construction of required necessary thrust blocks, construction of R.C.C. bridge on pile foundation above HFL for crossing of Nala etc complete to the satisfaction of engineer in charge. | 2,100 | Mtr | - | - |
| 8 | Rising main from IPS to STP:Supply and laying of 300 mm diameter DI K-9 pipe Pressure Pipes (S&S) with out side Zinc coating with finishing layer of Bitumen and have factory internal cement mortar lining in SRC cement for sewerage confirming to IS 8329:2000 (amended upto date) with push on type EPDM 'ISI marked' rubber gasket (including cost of rubber gasket) joining as per IS 5382 specifications with hydraulic field testing, commissioning as per specifications, providing, Erecting, Testing, Commissioning of C.I. double ball orifice type Air Valve, construction of air valve chamber as per type design including supply & fixing of 500 mm dia medium duty perforated C.I. cover, Providing, Erecting, Testing, Commissioning, of 150 mm dia Scour/Drain Valve with construction of chambers including dismanteling & restoration of road, excavation by manually or mechanically in inordinary soil (earth, sand, loam & clay) including ramming dressing, leveling by manually or mechanically, refilling of trenches in 15cm layer watering and ramming the same including removal of surplus earth or other dismantled material upto a distance of 500 m from the centre of trenches, construction of required necessary thrust blocks, etc. complete to the satisfaction of engineer in charge. | 1,410 | Mtr | - | - |
| 9 | Construction of STP at Bhagwanpur: Construction of one no. 55 MLD Sewage Treatment Plant on any proven technology to meet the KPI's as specified in bid document along with construction of Co-Treatment facility of 10 KLD, admin building, DG/Transformer yard, laboratory, boundary wall, Guard Room , Sludge handling facility, campus development, water supply, drainage, sewerage facility, approach & Internal Road, internal & external electrification, online monitoring facility, SCADA with all electro-mechanical components along with appurtenant works described in detail in bid document. | 1 | No. | - | - |
| 10 | Treated Effluent Pipeline: Design, Supply and laying of 1400 mm diameter NP-3 RCC pipe from STP to outfall point with suitable outfall structure to discharge effluent with protection works true to alignment and slope as per design, excavation, jointing, hydraulic testing and commissioning with necessary timbering, proper barricading approved by engineer in charge, bedding, backfilling with fine sand (Ganga) including dismentalling of existing 500 mm dia effluent line, dismanteling and restoration of roads as required, shifting & reinstatement of existing utilities if any, bailing out of water, construction of R.C.C. Manholes with heavy duty SFRC covers as per CPHEEO manual, disposal of surplus earth as per direction of engineer in charge, reinstatement of dismantelled roads including supply of all materials, labor and T&P etc. complete to the satisfaction of engineer in charge. | 1,350 | Mtr | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_1269306.xls
BOQ Document • 0.27 MB
113393621.pdf
Tender Document • 3.92 MB
Drawing.pdf
Tender Document • 3.24 MB
Tender_Document_Vol_1.pdf
Tender Document • 4.12 MB
Tender_Document_Vol_2.pdf
Tender Document • 4.09 MB
113393623.html
Tender Document • 0.03 MB
114639189.pdf
Tender Document • 0.91 MB
115672374.pdf
Tender Document • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .