| 1 | L1₹93,306Accepted-AOC | L1 | Accepted-AOC Lowest rates quoted by agency and negotiation given by agency | |
| 2 | L2₹1.0 L+₹9,474 (10.2%)Rejected-Finance | L2 | Rejected-Finance Highest rates quoted by agency |
Tender Value
₹73,000
EMD Value
₹1,500
Closing Date
8 Jun 2020, 5:00 pmClosed
Ravi Ladwal, EE
Executive Engineer Elect. Division PWD B and R Hisar
Construction of Sub Health Center at Village Madha in Distt. Hisar (Pdg. E.I Internal only).
2020_HRY_129926_1
PWD/Elect-GGR/Elect-HSR/17347
Open Tender
Construction Works
Works
60 days
Hisar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer, Elect. Division PWD B and R Br
₹1,500
24 Oct 2020
1 Jun 2020
9 Jun 2020
1 Jun 2020
8 Jun 2020
1 Jun 2020
Amount
1 : - Main Switches Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. (HSR 31.12 (a). v) Double pole switch 32 amp. 415 Volts Cat-B,
2 : - Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. (HSR 31.13) ii) Size 40 mm x 40 mm x 6 mm.
3 : - M.S.Sheet (HSR 31.14) i) Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
4 i : - Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (HSR 31.17) Miniature circuit breakers of 9 KA breaking capacity. ii) SP MCB 6 amp. to 32 amp.
ii : - iii) SPN MCB 6 amp. To 32 amp.
5 i : - Supply and erection of Fittings and Accessories (HSR 31.18) vii) Call bell 220 / 230 volts A.C. bakelite with double coil.
ii : - ix) Bell push flush type ( without flexible wire ) in existing sheet.
iii : - xi) Bakelite angle / straight button holder large size.
iv : - xii) Switch 5 amp. On existing sheet.
v : - xiii) Wall socket 5 amp. On existing sheet.
vi : - xxiv) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
vii : - xxvi) Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job.
6 i : - Erection and carriage of fans (HSR 31.20) i) Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
7 i : - Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. (HSR 31.21) xxi) Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
ii : - xxii) Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
8 i : - (Q) Earthing (HSR 31.22) i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
ii : - ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
iii : - xii) Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required .
iv : - xiv) Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
9 i : - PVC Insulated wiring in recessed conduit. (HSR 31.36) Wiring in 1.5 sqmm PVC insulated copper conduct cable in 1.6 mm thick conduit pipe. i) Fan Point b) Medium Point
ii : - ii) Light Point a) Short Point
: - b) Medium Point
: - c) Long Point
iii : - iii) Twin Control Light point with 2 way, 5 amp. Single pole switch c) Long Point
iv : - vi) Call bell point including MS box of size 180mmx 60 mm deep for call bell. c) Long point
v : - vii) 3 pin 5 amp. Plug point including earthing the 3rd pin etc. a) Short Point
: - c) Long point
vi : - viii) 3 pin 15 amp. Plug point with 4 amp. PVC insulated copper conductor cable including earthing the 3rd pin etc. c) Long point
10 i : - S/E of of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (HSR 31.40). i) Cable size 1.5 sqm(3/0.81 mm)
ii : - iii) Cable size 4 sqm(7/0.85 mm)
iii : - v) Cable size 10 sqm(7/1.35 mm)
11 i : - S/E of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.41) ii) 8-way, SP&N (Horizontal)
12 : - S/E of MS saddles and clamps on wall/ RCC parapet for fixing underground cable at a distance of 0.60 meter centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect upto the Engineer-in-Charge of the work. (HSR 31.48)
13 : - Supply and erection of 50mm diameter 1.5mtr. Long GI bracket (B-Class) making an angle 10 to 15 degree with horizontal plane for mounting street light fitting on GI bracket on wall with 2 Nos. 50mmx3mm thick MS flat including cost of cutting welding of GI bracket on wall with 2 nos. 50mm x 3mm thick MS flate including cost of cutting welding of GI pipe complete with cement sand mixture bolts and nuts etc including making necessary connection in all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (HSR 31.53).
14 : - Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Deluxe model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.55).
14 : - Non Schedule Items S/E of 45 W LED Street light fitting BRTFG45 W LED V2 make Bajaj/ LR02-501-XXX-57-XX of Wipro make/ LSTP-45-CDL-1 of Crompton make in aluminum PDC housing toughened glass cover with IP-66 protection With Lense including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work.
15 : - S/E of 18 W indoor LED Tube fitting with batten and tube, decorative ultra slim liniare LED lighting fixture with extruded poly carbonate, environmental friendly, energy effiecent completed including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. (Make:- Philips/ Havell's/ Crompton.)
16 : - Supply only of AC Ceiling fan without regulator of size 1200 mm (48") sweep complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Orient/ Crompton/ Havell's make.
Panchal Electrical
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .