Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC VILL GARANIA P O JUKHIA BAZAR P S BHUPATINAGAR DIST PURBA MEDINIPUR PIN 721430 | PURBA MEDINIPUR | WEST BENGAL | 721430 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.0 L+₹5,276.24 (0.31%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹19.5 L+₹2.6 L (15.0%)Rejected-Finance CHATTAPADMAPUR RAMNAGAR DIST PURBA MEDINIPUR | PURBA MEDINIPUR | L3 | Rejected-Finance 3rd lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to absence of OEM authorization Certificate, Updated P-Tax Certificate, Balance Sheet of last three years,Credential Certificate,Tech Person , Annex A , Annex B and Annex D |
| Sl No | Description | Qty | Unit | BHUNIA ENTERPRISE L1 | TAPAN ELECTRICS L3 | MAA NACHINDA ELECTRIC L2 |
|---|---|---|---|---|---|---|
| 1.00Supply of 2/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / RR Cable /Havells / Gloster] | ||||||
| 1.01 | 4core 10 Sq. mm (Street light) [ NS ] | 1,200 | Mtr | 344.56 ₹4,13,472 Lowest | 344.56 ₹4,13,472 Lowest | 389 ₹4,66,800 |
| 1.02 | 2core 6 Sq. mm (for Gate light) [ NS ] | 120 | Mtr | 192.34 ₹23,080.8 Lowest | 192.34 ₹23,080.8 Lowest | 205 ₹24,600 |
| 2.00 | Laying of 4 core 10 sqmm PVC/XLPE Ar. cable with earthing attachment in 10 SWG GI (Hot Dip)Wire in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. | 1,100 | Mtr | 197.06 ₹2,16,766 Lowest | 300.1 ₹3,30,110 | 200 ₹2,20,000 |
| 3.00 | Laying of 2 core 6 sqmm PVC/XLPE Ar. cable with earthing attachment in 10 SWG GI (Hot Dip)Wire in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. | 120 | Mtr | 197.06 ₹23,647.2 Lowest | 197.06 ₹23,647.2 Lowest | 205 ₹24,600 |
| 4.00 | Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core. | 100 | Mtr | 51.92 ₹5,192 Lowest | 51.92 ₹5,192 Lowest | 76 ₹7,600 |
| 5.00 | Supplying & fixing 40 mm medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. | 70 | Mtr | 298.54 ₹20,897.8 Lowest | 298.54 ₹20,897.8 Lowest | 323 ₹22,610 |
| 6.00Supplying and fixing compression type gland those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. | ||||||
| 6.01 | 4core 10 Sq. mm | 80 | Each | 210 ₹16,800 | 160.48 ₹12,838.4 Lowest | 175 ₹14,000 |
| 6.02 | 2core 6 Sq. mm [7(a)/F-4 ] | 10 | Each | 82.6 ₹826 Lowest | 82.6 ₹826 Lowest | 90 ₹900 |
Tender Value
Refer Docs
EMD Value
₹34,016
Closing Date
13 Sept 2025, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SENIOR SUPERINTENDING ENGINEER
GOVERNMENT OF WEST BENGAL OFFICE OF THE SENIOR SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Repairing and Renovation of street light at New integrated Govt. School, Ramnagar II , Purba Medinipur.
2025_WBPWD_896150_1
WBPWD/SSE/SWEC/NIQ42/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
PURBA MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹34,016
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER
30 Oct 2026
28 Aug 2025
15 Sept 2025
28 Aug 2025
13 Sept 2025
3 Sept 2025
2 Sept 2025
Amount
Supply of 2/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / RR Cable /Havells / Gloster]
4core 10 Sq. mm (Street light) [ NS ]
2core 6 Sq. mm (for Gate light) [ NS ]
Laying of 4 core 10 sqmm PVC/XLPE Ar. cable with earthing attachment in 10 SWG GI (Hot Dip)Wire in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of 2 core 6 sqmm PVC/XLPE Ar. cable with earthing attachment in 10 SWG GI (Hot Dip)Wire in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core.
Supplying & fixing 40 mm medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
Supplying and fixing compression type gland those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4core 10 Sq. mm
2core 6 Sq. mm [7(a)/F-4 ]
Supplying and fixing crimping type finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4core 10 Sq. mm
2core 6 Sq. mm
Supply, delivery and installation of 7 Mtr. Octagonal Poles in 3mm shaft thickness with Top A/F 70 mm, Bottom A/F - Minimum 130 , Base Plate Size-minimum 200x200x12 mm suitable for wind speed 180 Km/hr. as per IS:875 with suitable bracket arrangement to install 1 or 2 no. Led Steet Light and window with flash cover at a height of 0.5 mtr. from the the base for cable termination block inbuilt loop box having 4 terminal loop stud inside the pool with inspection door and locking arrangment and 1no 6A SPMCB (make- Legrand) as per direction of EIC. A) Material grade of shaft shall be of S355JO/JR as per BSEN 10025 or Equivalent IS: 2062 grade E350 (BR) B) Materials grade of Base Plate shall be E250(BR) as per IS:2062 C) Galvanization as per BSEN ISO:1461 [ Make– Bajaj/ Valmont/ Transrail/Subham pole]
Supply and fixing of 4 Nos. M20X600 “J” Type foundation bolts as per EN-8 Grade (TS-600) manufactured from special steel along with nuts, washers, and templates as per direction of EIC.
Construction of suitable Shallow foundation for the above said octagonal Pole with M-20 grade concrete for Pole considering soil bearing capacity (SBC) 10T/sq. mtr. at 2 Mtr. depth with all materials and labour payment made as per PWD civil schedule
Supply and fixing of 1500 mm Single Arm Bracket made of 40 NB /48.3 OD Mild Steel Pipe as per IS:1161 suitable to insert at Pole Top A/F 70 as per direction of EIC.
S & F of Fiber reinforced plastic water proof type 200x150x100mm Loop box having 4mm thick comprising of one 250V 15A Kit Kat fuse unit, one 1ph NL bar on porceling insulator, (make- SINTEX, code-GSJB-1414 ) & incl. necessar accessories.
Supplying & Delivery of 70 Watt LED,minimum System efficacy 120lm/Watt, Outdoor Street Light fittings having colour Tep-57 K, CRI-70, IP -66 protectection and IK-09 with all accessories and minimum 05 years of onsite Warrenty. (Make: Surya-SLE UL 70W IP66 NGN/Wipro-LR02-781-XXX-57-G3 or equivalent of Phillips)
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length arm bracket, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
Supply & fixing of minimum 30 W LED Post Top light fitting (IP 65) complete with all accrssories suitable for light fitting (Make: Surya-RIGEL SLE PT 30W/ Phillips-BGP161 LED2500 or equivalent of Wipro ) to be fixed complete with all accessories.
Supply & Fixing of 240V minimum 40 W LED UniScape Post Top light fittings on main gate, complete with all accessories, light should be fixed on gate top with necessary nut bolt arramgement (Surya-ETPP SLE PT 40W/ Wipro-LP07-501-XXX-57-CL or equivalent of Phillips).
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground evel and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By ISI-Medium GI pipe
Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Solid GI wire No 4 S.W.G wire
Excavation of soil for installation of Earth Electrode and filling & ramming. For soft Soil
Testing & checking of all wiring of street light
MAA NACHINDA ELECTRIC (BID ID -6926301)
TAPAN ELECTRICS (BID ID -6925729)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .