Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC | L1 | Accepted-AOC Successful bidder as L1 bidder | |
| 2 | L2₹33.5 L+₹4,971 (0.15%)Rejected-AOC CHITADARCHUK CITY TWON MAJULI P O CHITADARCHUK P S GARAMUR DIST MAJULI PIN 785104 ASSAM | MAJULI | ASSAM | 785104 | L2 | Rejected-AOC Unsuccessful bidder | |
| 3 | L3₹33.6 L+₹15,928 (0.48%)Rejected-AOC | L3 | Rejected-AOC Unsuccessful bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Technically not qualified |
Tender Value
₹32.0 L
EMD Value
₹63,932
Closing Date
14 Dec 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE PWD Dist Ghy East Ter. Bldg. Div
O/o the EE PWD Dispur and Guwahati East Territorial Building Division, Fancy Bazar, Guwahati-1
Maintenance work of NCC RCC (G 3) Building at Paltanbazar, Guwahati-08
2023_PWBNH_34195_1
DGETBD_Maintenance work_NCC Bldg
Open Tender
Civil Works - Building
Item Wise
90 days
Paltanbazar, Guwahati
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹63,932
Yes
O/o EE PWD Dist Ghy East Ter. Bldg. Div
30 Jan 2024
24 Nov 2023
15 Dec 2023
24 Nov 2023
14 Dec 2023
24 Nov 2023
1 Dec 2023
Amount
Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :15.12.1 : Of area 3 sq. metres and below
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in- charge (Door handle, lock and stopper etc.to be paid separately).
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2: 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :13.41.1: New work (two or more coats) over and including water thinnable priming coat with cement primer
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :13.99.1: One or more coats on old work
Finishing walls with textured exterior paint of required shade :13.110.1: Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.18.50.1:15 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :18.22.1: 100 mm diameter 18.22.2:150 mm diameter
Providing and fixing PTMT pillar cock of approved quality and colour.18.56.1: 15 mm nominal bore, 107 mm long, weighing not less than 110 gms
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.12.41.1: 75 mm diameter
12.41.2 : 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.12.42.3: Single tee with door 12.42.31: 75x75x75 mm
Single tee without door 12.42.4.1: 75x75x75 mm
Bend 87.5° 12.42.5.1: 75 mm bend
110 mm bend
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 18.10.2: 20 mm dia nominal bore
Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 18.9.5: 40 mm nominal outer dia Pipes
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required. 1.8.3: Group-C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required. 1.27.2: 3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.2: 3 Module
6 Module
8 Module
12 Module
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.1.24.1 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
2 way 5/6 A switch
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.10.3: Double pole
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.2.2.16 250 A,36KA,FPMCCB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 2.4.1_4 way (4 + 12), Double door
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
Supplying with fitting and fixing Philips 16W Led Recessed Luminaire complete including making necessary connection as approved, specified and directed by the deptt
Supplying with fitting and fixing of Philips 18W HL Yes 5 Star 1250 for 18W HL with 6500 K G-13 including making necessary connection as per direction of department.
Supplying with fitting and fixing of Philips Base B22 9-Watt Led Bulb (Cool Day Light) including making necessary connection as per direction of department.
Supplying and fitting fixing of Powder coated die cast aluminium alloy with UV stabilized clear one piece PMMA diffuser IP 65 Led post top lantern, Power 30 Watt including necessary connection etc. as required complete and as directed by the Department.
Supplying and fitting fixing of Supply fitting & fixing of crompton Led Street Light including necessary connection etc. as required complete and as directed by the Department.
Supplying with fitting and fixing BILGON Digital Volt Meter 5.0 KVA Automatic Line Voltage Corrector Or Step Type Auto Transformer complete including making ecessary connection as approved, specified and directed by the deptt.
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.Overload Relay Range 16 - 25 Amps in 3 Module, Note(This item is not available in GEM Portal)
Supplying with installation testing and commissioning of Nezone make 1000mm length single Arm Bracket as approved and directed by the Deptt. Note This item is not available in GEM portal)
Re-Installation /Testing / Comissioning
Dismantal of Hi-Wall Split Type Air Conditioner
Hi-Wall Split Type Air Conditioner Gas Refilling
Replacement of Coil Condenser
Jet Pump Service
Overall Servicing of 250KVA Silent DG set (changing of Mobil and Mobil Filter,Changing of Coolent and Coolent Filter, Repairing of Control panel)
Supplying with fitting and fixing of ajanta 120 Squmm a 4 Core PVC Aluminium Cable (Heavy Duty)(aluminium armoured cable) complete
LAKHYAJIT KAMAN
M/s Assam Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .