| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹18.9 L+₹89,845 (5.00%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹19.0 L+₹99,315 (5.53%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹19.8 L+₹1.8 L (10.1%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹20.1 L+₹2.1 L (11.9%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹34,000
Closing Date
14 Oct 2024, 6:00 pmClosed
GE GAYA
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar, PIN-823005
Repair/replacement of internal wiring, DBs meters boxes, fitting fixture and service cables in Md Accn at Mil Stn Gaya.
2024_MES_676879_2
8036/GE/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GAYA
₹34,000
Yes
18 Nov 2024
5 Oct 2024
15 Oct 2024
5 Oct 2024
14 Oct 2024
9 Oct 2024
Amount
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/ concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
M & L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- (a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps.
(c) One light point controlled by one, two way switch 5 Amps
(d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
(f) One bell point controlled by one, bell switch 5 Amps
Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
Description all as per item No. 4 here in before but using 4.0 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point)
S & F switch piano type single pole 5 amp, 230 Volts complete all as specified and directed.
S & F switch piano type single pole 15 amp, 230 Volts complete all as specified and directed.
S & F switch bell push piano type 5 amp, 230 Volts Complete all as specified and directed.
S & F socket outlet 2-in-1, 5 pin, 5 amp, 230 Volts complete all as specified and directed.
S & F socket outlet 2-in-1, 5 pin, 5/15 amp, 230 Volts complete all as specified and directed.
S & F ceiling rose, surface bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F stepped type electronic fan regulator flush type complete all as specified and directed.
S & F lamp holder, PVC / Polycarbonate type with back plate suitable for batten/ slanting fittings complete all as specified and directed.
S & F bell electric ding dong type suitable for operation on 230 volt 50 Hz AC supply complete all as specified and as directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 2.5 sqmm cable and one run of PVC conduit will be measured as one unit.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including in PVC casing caping on surface in wall etc one run of PVC insulated with 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 2.5 sqmm cable and one run of PVC conduit will be measured as one unit.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including in PVC casing caping on surface in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit.
S & F sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F metal clad box suitable for 230 volt 50 Hz AC supply three pin plug with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed
S & F energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make : Bajaj Cat No BIBWP 10W LED or its equvalent in Philips, Wipro.
S & F wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make: Bajaj Cat part No BCLAB 20W WH LED P, Wipro Cat part No LL20-281-XXX065-ALI or its equvalent in Philips, Havells.
S & F energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make : Bajaj Cat part No ENXT P 24L WH CR PC SD (Edge plus series) or its equvalent in Philips, Wipro, Havells
M&L Earthing with galvanized steel earthing plate electrode 60 cm x 60 cm 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep being ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connecting to a galvanised earth lead wire 4 mm dia by means of bolts, nut check nut and washers protected with and including 15 mm dia light grade GI pipe, necessary excavation and earth work, charcoal and common salt filling, watering arrangement with 20 mm GI pipe light grade including PCC pit with pre cast RCC (1:2:4) cover, GI funnel with test point, testing and commissioning all as specified and directed.
S & F in replacement of service wire 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with tape and overall PVC sheathed 10 Sqmm two core nominal cross section complete all as specified and directed.
S & F in replacement of service wire 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with tape and overall PVC sheathed 16 Sqmm two core nominal cross section complete all as specified and directed.
BISHWNATH KUMAR BHARTI (BID ID -3137326)
M/S SANJAY KUMAR YADAV (BID ID -3138947)
M/S VIKAS CONSTRUCTION CO. (BID ID -3134499)
M/S PANCHAM RAI SONS (BID ID -3139157)
MAA BHAGWATI TELECOM LINK (BID ID -3138630)
M/s Vinay Kumar (BID ID -3138638)
M/S ABHAY KUMAR AND BROTHERS (BID ID -3138936)
SINGHAL ENTERPRISES (BID ID -3138870)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .