Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹3.9 L
Closing Date
29 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or " V" whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully or substantially completed any of the following during last 07(seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of work for this tender is -" Electronic Interlocking work { Indoor OR (Indoor + Outdoor)}. And/OR Panel Interlocking work { Indoor OR (Indoor + Outdoor)}. And/OR Route Relay Interlocking work { Indoor OR (Indoor + Outdoor)}."
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
CONSTRUCTION OF COMMON LOOP FOR LEFT OVER WORK AT Sagardighi(SDI) STATION OF HWH DIVISION.
SDSTE-COMMONLOOP-SDI-26
SDSTE-COMMONLOOP-SDI-26
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹3.9 L
29 May 2026
5 May 2026
15 May 2026
181 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,96,00,576.47 | ||
| — | — | — | 53,99,238 | ||
| Modification /Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines /TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved S I P a n d circuit diagrams. A l l the material (Interface cards/re1ays/wiring material/ connectors /fuses/communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings /circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. A)Alteration involving modification from 11 up to 20 routes | — | 2.00 | — | — | |
| — | — | — | 49,160 | ||
| Modification/ upgradation, validation and alteration of data logger as per site engineer. This includes changes of NMDL software etc. Also data logger to be interfaced with PI/ EI equipment keeping at relay room. This work includes validation, wiring, etc. For this work necessary wire from relay to tag block & from tag block to data logger and tag block, terminal, wiring material etc. required for this work to be supplied by contractor. Wire to be procured from RDSO approved firms and to be inspected by consignee. | — | 1.00 | — | — | |
| — | — | — | 75,380 | ||
| Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS: S-34 & S-23 with Amdt. upto date or latest. The interlocking code for this unit shall be "ABCDE". Inspection authority:- RDSO | — | 20.00 | — | — | |
| — | — | — | 74,740 | ||
| Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No. IRS: S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABCDF". Inspection authority:- RDSO | — | 20.00 | — | — | |
| — | — | — | 76,900 | ||
| "Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn. No.IRS: S@45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be ""ABDGH"". Inspection authority:- RDSO" | — | 20.00 | — | — | |
| — | — | — | 1,14,360 | ||
| Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No. IRS: 5-34 & S-23with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDEG". Inspection authority:- RDSO | — | 20.00 | — | — | |
| — | — | — | 98,240 | ||
| Q-Series LED ECR (Universal Type i.e. QECX- 61), 4F/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS:94 1A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt. -1 and RDSO Specn.No.IRS: S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDHK".Inspection authority:- RDSO | — | 20.00 | — | — | |
| — | — | — | 39,100 | ||
| Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 60/40 core cable/flexible wire on tag block/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on ER & the instruction of Rly. Engineer at site. Inspection authority:- Consignee | — | 100.00 | — | — | |
| — | — | — | 1,10,000 | ||
| "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." A)Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) | — | 2000.00 | — | — | |
| — | — | — | 10,000 | ||
| "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." B)Supply of End plate 2.5mm/0.091 in thick as per site requirement. | — | 1000.00 | — | — | |
| — | — | — | 10,000 | ||
| "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." C)Supply of End Stopper 10mm/0.0394 in width as per site requirement. | — | 1000.00 | — | — | |
| — | — | — | 1,09,000 | ||
| "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." D)Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | 1000.00 | — | — | |
| — | — | — | 8,000 | ||
| "Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/ SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link o f international standard for Railway signalling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." E)Supply of Markers strip. | — | 500.00 | — | — | |
| — | — | — | 6,47,000 | ||
| "Transportation of HDT machine/Micro Tunnelling through Horizontal directional drilling (HDD) machine with accessories including handling of stores materials, preparation of sites, boring and laying of DWC/HDPE/GI pipes for crossing of S&T cable at bridges/culverts/track crossing/pucca road crossing. Boring diameter should be at least 110mm & shall be minimum 3 (three) meter below the river bed and minimum 1 m at track/road/pucca road crossing area etc. In case the site doesn't allow to perform as per schedule, written approval must be obtained from at least site in charge officer. The ground level shall be considered ignoring the bank height of the bank of the road. Note: DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after laying of the cables into DWC/HDPE/GI pipe is laid in the bore." | — | 1000.00 | — | — | |
| — | — | — | 55,600 | ||
| Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to O.6 Mtrs wide and back filling after placing of DWC / RCC/GI pipe. (Placing of DWC/ RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. F o r track crossing, RDSO sketch No. SDO/CABLE LAYING/ 009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed. | — | 200.00 | — | — | |
| — | — | — | 45,000 | ||
| Termination of Outdoor Cables (Main Cables / tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: Consignee | — | 5000.00 | — | — | |
| — | — | — | 15,600 | ||
| Supply of PBT ARA terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST. Material to be procured from RDSO's approved fi r m only. Inspection: RDSO. A)1 WAY,DRG NO.23741A, ALT-4. | — | 200.00 | — | — | |
| — | — | — | 2,745 | ||
| Supply of fuse block (PBT) to spec.no.IRS-5- 75/2006(REV-2) OR LATEST, DRG.NO.SA- 2 3 7 4 8 w i t h f u s e inserts cartridge, non- deteriorating type to spec.IRS-S-78/92 with latest amendment, to be mounted inside the location box on hylum sheet. Inspection: - RDSO. A)Fuse, non- deteriorating(2A/6A/10A/16A) type, cylindrical(IRS-S-78/92) [quantity as per site requirement] | — | 45.00 | — | — | |
| — | — | — | 8,010 | ||
| Supply of fuse block (PBT) to spec.no.IRS-5- 75/2006(REV-2) OR LATEST, DRG.NO.SA- 2 3 7 4 8 w i t h f u s e inserts cartridge, non- deteriorating type to spec.IRS-S-78/92 with latest amendment, to be mounted inside the location box on hylum sheet. Inspection: - RDSO. B)Fuse Base. | — | 45.00 | — | — | |
| — | — | — | 5,400 | ||
| Carrying out relay alteration to the existing relay wiring at relay rack/location box as per the approved circuit diagram. These work includes the releasing of existing unused wires and wiring the relays using 16/0.2 mm copper wire as per RDSO Spec. Wire to be procured from RDSO's approved source and inspection: by RITES [for value of material above Rs. 5.0 lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]. Note: - wire to be procured from RDSO's approved source only. All required material like wire, soldering material, paint etc. To be supplied by the contractor for execution of the work. | — | 20.00 | — | — | |
| — | — | — | 1,31,515 | ||
| Inter connection wiring with ladder arrangement from control panel to IPS to relay rack, battery & CTR. This includes interconnection, wiring with ladder arrangement between relay racks, CTRS, control cum indication panel and relay rack tag blocks for data logger. This also includes termination of cables / wires on all the above and dressing, bunching etc. As required at site. 16 sq. mm. cable to be used between IPS & it's battery duly soldered with good quality lugs in duplicate. From relay rack to panel wire should be of 40/60 core multicore cable of 1 sq.mm., 0.5mm dia., 16/0.2 mm for relays, 3/0.75 mm for MCBS and 10 sq.mm for power wiring. Indoor cable will be 60 x 1 mm /40 x 1 mm as per IRS-S-76/89, amd-2 or latest for interconnection. Supply of wires / cables by the contractor, shall be procured from RDSO's approved firm only & to be duly inspected. Note:1) necessary 40/60 multicore, 16/0.2 mm, 3.0.75 mm, 10 sq.mm cables required for wiring to be supplied by the contractor. 2)to suite load requirement necessary re- arrangement of DC-DC converters by OEM of IPS. A)Up to 6 Lines Station | — | 1.00 | — | — | |
| — | — | — | 1,51,470 | ||
| "Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags o f minimum 1 0 k g = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod - 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of l50x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO" | — | 10.00 | — | — | |
| — | — | — | 65,790 | ||
| "Installation of Unit Maintenance Free Earth as supplied in above item. It includes ( i ) Digging the earth to the required depth. (ii) Insertion o f electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper a n d outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential bus bar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential bus bar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover t h e earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest.Inspection: Consignee" | — | 10.00 | — | — | |
| — | — | — | 89,760 | ||
| "Supply of earth electrode mild steel galvanized, light class, IS:1239(PART-I) - 1979.earth electrode pipe should be with 3 mm thick, 50 mm dia and perforated(staggered),5 mm dia holes, 2 nos per 305 mm length with clamp of MS FLAT(galvanised) of size 35 mm x 6 mm (SPEC. NO.226 STD). Earth pipe should include CI threaded cap. Materials to be procured and designed as per CSTE /ER'S DRG.NO.SI/TYP/0097 DTD. 25.03.25. Inspection: - BY RITES [for value of material above Rs. 5.O lakhs.]. Inspection by consignee [for value of material below than Rs 5.0 lakh]" | — | 60.00 | — | — | |
| — | — | — | 54,660 | ||
| Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE /ER'S DRG.NO.SI/TYP/0097 DTD. 25.03.25 (or latest). Inspection : by consignee. | — | 60.00 | — | — | |
| — | — | — | 69,660 | ||
| Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE /ER'S DRG.NO.SI/TYP/0097 DTD. 25.03.25 for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing M S fl a t a t apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories a n d welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note:-all materials required to be arranged by the contractor except 2 core cable will be supplied by the railway. | — | 60.00 | — | — | |
| — | — | — | 34,260 | ||
| Provision of cement concrete enclosure for earth electrodes as per DRG. NO. S&T/C- 36(NKG). This includes supply of all materials by the contractor duly inspected by consignee. | — | 60.00 | — | — | |
| — | — | — | 2,09,050 | ||
| "Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest. Inspection: RDSO" A)RED Aspect | — | 25.00 | — | — | |
| — | — | — | 2,51,610 | ||
| "Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest. Inspection: RDSO" B)YELLOW Aspect | — | 30.00 | — | — | |
| — | — | — | 1,88,760 | ||
| "Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest. Inspection: RDSO" C)GREEN Aspect | — | 20.00 | — | — | |
| — | — | — | 78,535 | ||
| "Supply of colour light signal post 5.6 mtr and ladder 5.5 mtr with bases for ladder & post as per RDSO SPEC. NO. IRS:S-6-81 (or latest) and DRG. NO. SA-23156 (ADV), ALT-1 (OR LATEST). CLS base as per DRG. NO. S-2011/M (OR LATEST). Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Materials to be procured only from RDSO approved list of firms for manufacture & supply of mechanical signalling items. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 5.00 | — | — | |
| — | — | — | 79,749 | ||
| Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 2 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as RDSO SPEC NO. RDSO/ SPN/ 151/1997 OR LATEST. Afl drawings should be as per latest. Materials to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes LED signal lighting unit including current regulator. This also includes protection of unit from rain water. A)"Supply. Inspection: (i)RDSO/RITES if value of item i n w ork m ore tha n 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 3.00 | — | — | |
| — | — | — | 4,974 | ||
| Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 2 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as RDSO SPEC NO. RDSO/ SPN/ 151/1997 OR LATEST. Afl drawings should be as per latest. Materials to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to 'LED' type. Note: installation, erection & wiring of signalling unit includes LED signal lighting unit including current regulator. This also includes protection of unit from rain water. B)Execution | — | 3.00 | — | — | |
| — | — | — | 61,566 | ||
| Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 4 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as per rdso spec no. Rdso/spn/151/1997 or LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only. Note: Signal unit should b e compatible t o 'LED' type. Note: installation, erection & wiring of signalling unit includes led signal lighting unit including current regulator. This also includes protection of unit from rain water. A)"Supply. Inspection: (i)RDSO/RITES if value of item i n w ork m ore tha n 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 2.00 | — | — | |
| — | — | — | 5,460 | ||
| Installation, erection and wiring of CLS unit, post, ladder & base LED unit including paying out of tail cable from location box and earthing of CLS (LED type). This includes supply of non - metallic (FRP) colour light signal housing multi-unit type for Rly. Signalling suitable for RE Area 4 Aspect complete without lenses, lamps and signal transformer as per DRG. NO. SA 23001/A/M(ADV), ALT.8 and as per SPEC. NO. RDSO/SPN/194/2006 (VER1.0) OR LATEST. FRP material as per rdso spec no. Rdso/spn/151/1997 or LATEST. All drawings should be as per latest. Materials to be procured from RDSO's approved firm only. Note: Signal unit should b e compatible t o 'LED' type. Note: installation, erection & wiring of signalling unit includes led signal lighting unit including current regulator. This also includes protection of unit from rain water. B)Execution | — | 2.00 | — | — | |
| — | — | — | 17,510 | ||
| Supply and fixing of protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per std. practice in RE Area. Inspection: Consignee. | — | 5.00 | — | — | |
| — | — | — | 1,865 | ||
| "Supply, Fabrication and Fixing of Retro reflective Nomenclature Board of size 254 mm x 358 mm made of 2mm thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE -IV) including fixing arrangement for fixing them on existing post as per standard practice. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 5.00 | — | — | |
| — | — | — | 5,026 | ||
| Supply of cast iron offset bracket for Main Signal with U clamps, nuts, washers complete DRG. NO. SA-23080/ADV/ALT-1. RDSO SPEC. NO. IRS-5- 10/78. Inspection: consignee. Note : Offset bracket has to be connected wherever necessary as per site engineer. | — | 2.00 | — | — | |
| — | — | — | 40,325 | ||
| Casting, concreting & curing of foundation for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips as per DRG. NO. S&T/C-42(NKG). | — | 5.00 | — | — | |
| — | — | — | 15,325 | ||
| Releasing of existing tail cables and drawl of new tail cables for colour light signals up to four aspects with or without route indicator, post type shunt signal and calling signals. Termination of new tail cables and wiring using wire PVC 3/0.75 mm copper as per latest RDSO spec. This work includes drawl of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals [Wire PVC 3/0.75 mm copper, paints and all other miscellaneous materials shall be supplied by the contractor. Wire to be procured from RDSO's approved source only]. Inspection- consignee. | — | 5.00 | — | — | |
| — | — | — | 6,090 | ||
| Dismantling of existing main signal including dependent shunt signal, calling on signal if any, fitted on the same post along with signal post, signal unit, ci base without damaging any part. | — | 5.00 | — | — | |
| — | — | — | 11,060 | ||
| Dismantling of existing Signal Foundation (upto ground level by hydraulic breaker). | — | 5.00 | — | — | |
| — | — | — | 7,599 | ||
| "Supply of Calling ON/ Guard Repeater Signal Unit with Brackets & Fixing accessories. Calling ON/ Guard Repeater Signal Unit shall conform to RDSO Drg no 24351(Adv) A1t1 suitable to LED Signal Lighting Unit. Inspection: (i)RDSO /RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 3.00 | — | — | |
| — | — | — | 6,993 | ||
| Fixing of Calling-on Signal/A-Sign/AG-Sign unit on signal post including Guard Repeater Signal. The item includes fixing of Co- On signal /'A' sign/ 'AG' sign unit on signal post with bracket, hood etc. Item includes supply of bracket & fixing materials etc. by the contactor. The item also includes termination of cables & wiring inside Co- On signal /'A' sign/ 'AG' sign unit as per standard practice. Inspection: Consignee. | — | 3.00 | — | — | |
| — | — | — | 34,117 | ||
| Installation, erection and wiring of junction type route indicator [LED type] this include supply of non metallic FRP junction type route indicator for Railway Signalling suitable for RE Area without lamp. Lenses, signal transformer as per RDSO SPEC. NO. RDSO/SPN/194/2006 (VER - 1.0) OR LATEST. FRP material as per RDSO SPEC. NO. RDSO/SPN/151/ 1997 OR LATEST. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to LED type. Note: installation, erection & wiring of signalling unit includes LED signal, lighting unit including current regulator. This also includes protection of unit from rain water. A)"Supply of 1 WAY AS PER RDSO DRG. NO. SA- 23401 (ADV)/ ALT.2 Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 1.00 | — | — | |
| — | — | — | 669 | ||
| Installation, erection and wiring of junction type route indicator [LED type] this include supply of non metallic FRP junction type route indicator for Railway Signalling suitable for RE Area without lamp. Lenses, signal transformer as per RDSO SPEC. NO. RDSO/SPN/194/2006 (VER - 1.0) OR LATEST. FRP material as per RDSO SPEC. NO. RDSO/SPN/151/ 1997 OR LATEST. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: Signal unit should be compatible to LED type. Note: installation, erection & wiring of signalling unit includes LED signal, lighting unit including current regulator. This also includes protection of unit from rain water. B)Execution of 1 WAY AS PER RDSO DRG. NO. SA- 23401 (ADV)/ ALT.2 | — | 1.00 | — | — | |
| — | — | — | 27,720 | ||
| "Installation, erection and paying out of tail cable from location box and wiring of shunt signal, LED unit on the same post below the main signal as per technical specification. This includes supply of position light shunt signal unit without lenses, lamps, base, post and without signal transformer as per RDSO DRG NO. SA-23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type." A)"Supply. Inspection: (i)RDSO/RITES if value of item i n work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 5.00 | — | — | |
| — | — | — | 2,525 | ||
| "Installation, erection and paying out of tail cable from location box and wiring of shunt signal, LED unit on the same post below the main signal as per technical specification. This includes supply of position light shunt signal unit without lenses, lamps, base, post and without signal transformer as per RDSO DRG NO. SA-23840/ADV/ALT-2. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note- Signal unit should be compatible to 'LED' type." B)Execution | — | 5.00 | — | — | |
| — | — | — | 24,840 | ||
| Supply of Point JB fitted with 18 nos. 1-way terminal block confirming to IRS-S-75/91 (AMD-2) OR LATEST, DRG. NO. SA-2374 1A with 3 no. of 40 mm bore G I PIPE 600 mm long as per DRG. NO. SGW/MGS/ PT4/91 fixed on hylum sheet with U channel (75x40x1500) mm for fixing ARA terminal to be procured from RDSO approved sources. Inspection- Consignee. | — | 6.00 | — | — | |
| — | — | — | 7,86,990 | ||
| Supply of Electric Point machine IRS type 220 mm throw, high thrust (AC immunity 160V AC), non trailable to operate on 110V, DC complete with Lock and Detector slides, Cable Termination Box and clamp lock 60 Kg. confirming to IRS: S 24/2002 & Assy. Drg. No. RDSO-S /11000 & For Motor IRS: S 37/82. (items to be procured through stores)Inspection: RDSO | — | 6.00 | — | — | |
| — | — | — | 62,442 | ||
| Installation of electric point machines on MS plate fixed on wooden/ concrete sleepers complete with fixing of junction boxes, ground connections including smithy works involved, insulation of MS plate on which the point machine is to be fixed from the gauge tie plate involving riveting/welding of angle cleats, installation of point JB, termination adjustment for operation of points by crank handle, painting and lettering as required including wiring, testing and commissioning. Note: MS plate/flat/angle /angle cleats, paints, bolts & nuts and washers of sizes as required for fixing the point machine shall be supplied by the contractor except point machine. | — | 6.00 | — | — | |
| — | — | — | 2,42,844 | ||
| Supply of TWS 220 mm Point Ground Connection Set of thick web point machine. Drg No. RDSO/S-3454 Alt-A Ver.1 or Similar | — | 6.00 | — | — | |
| — | — | — | 49,770 | ||
| Dismantling of existing point fittings, drilling of holes in stock rail/tongue rail/ gauge tie plate, re arrangement and refixing of existing electrical detector and installation of IRS 24/2002 with latest Amdt. point machine on MS plate fixed on wooden/concrete sleepers complete with fixing of point JB ground connections including smithy job for welding & termination & wiring of point machine, adjustment and testing as per technical specification and dismantling of all new fittings excluding point machine and marking with paint for future and transportation up to railway's store | — | 6.00 | — | — | |
| — | — | — | 12,320 | ||
| "Point insulation Complete set as per RDSO/ SPN/168/2005 for 1.Switch bracket 'D' bracket insulation for IRS point machine - One set comprises of (a)Side plate LH to Drg. No.S-3266 - 1 No. (b)Side plate RH to Drg.No.S-3265 - 1 No. (c)Insulating bush to Drg.No.S-3199 - 4 Nos. (d) Insulating washer to Drg.No.S-8640 - 4 Nos., 2. Split-Stretcher bar 2.1 Insulation for Leading stretcher bars(BG) each set comprising of (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg.No.T-10384 - 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg.No.T-10535- 4 Nos. (c) Insulating Washer for insulated stretcher bar BG as per RDSO drg.No.T-10371 - 6 Nos. 2.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg.No.T-10367 - 3 No. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg.No..T-10368 - 6 Nos. (c)Insu1ating washer for insulated stretcher bars BG as per RDSO Drg.No.T10371 - 12 Nos& 3. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washer each set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg.No.T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg.No.T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg.No.T-10371 - 6 Nos. Inspection: (i) RDSO/ RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 10.00 | — | — | |
| — | — | — | 3,650 | ||
| "Gauge Tie plate insulation as per RDSO/ SPN/168/2005 as per RDSO drg. No: T- 10372Alt2, T- 10368, T- 10371A1t2, T-15083/88/Alt2 & T-11690/Alt2 and as per RDSO/ SPN/168/2005 with latest amendments as applicable. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washer each set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg.No.T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg.No.T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg.No.T-10371 - 6 Nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 10.00 | — | — | |
| — | — | — | 1,870 | ||
| "Supply of William Stretcher Insulation Set (complete) as per RDSO/SPN/168/2005 with insulating bush and washer to suit point layout and conforming to RDSO Drg.No.T-10372 or latest, T-10368 or latest and T-10371 or latest. 1.1 Insulation for Leading stretcher bars(BG) each set comprising of (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg.No.T- 10384 - 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg.No.T-10535- 4 Nos. (c) Insulating Washer for insulated stretcher bar BG as per RDSO drg.No.T- 10371 - 6 Nos. 1.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg.No.T-10367 - 3 No. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg.No..T-10368 - 6 Nos. (c)Insulating washer for insulated stretcher bars BG as per RDSO Drg.No.T10371 - 12 Nos Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 10.00 | — | — | |
| — | — | — | 2,78,320 | ||
| Supply of full size apparatus case (GKP type) (as per DRAWING NO. SW SK NO. 4/90 & & other applicable GKP SW Drawing). This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S- 11500. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED L I S T O F F I R M S FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy | — | 20.00 | — | — | |
| — | — | — | 70,640 | ||
| Casting, concreting and curing of concrete foundation ((in ratio 1:3:6), erection and installation of full size apparatus case (GKP type)/Stainless Steel (SS) Apparatus Case as per DRG.NO. S&T/C-6/98(NKG) with 'E' type lock on CC foundation. This includes cost of all materials required for fixing holding down bolts, casting, concreting. Note: - bolts, nuts and washers, bitumen compound to be supplied by contractor and bitumen compound to be used in between apparatus case and foundation as per site engineer. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: - Location boxes to painted with anti- corrosive paints as per IS:- 9862-1981, one and half feet from the bottom, on all surfaces- both inside and outside. Inspection: Consignee | — | 20.00 | — | — | |
| — | — | — | 96,600 | ||
| Fixing by slotted angle, wiring of terminal strips, hylam strip, relays, fuses with base, fixing of hard wood shelves for full size apparatus case with termination & Earthing of cables and wiring with lettering as required including supply of slotted angles, wires, ferrules for marking and miscellaneous materials per location to be supplied by contractor. (all materials except relay, terminal strips, Bakelite strip, fuses with base and hard wood shelves to be supplied by the contractor). Wires to be used for this purpose should be procured from RDSO'S approved firm and to be inspected by RDSO. [Quantity of wires to be specified by contractor]. NB- power cable to be terminated with proper lugs and required buss bar and other terminals to be supplied by the contractor. Inspection: Consignee | — | 20.00 | — | — | |
| — | — | — | 22,520 | ||
| Supply of hard wood shelves thickness 25 mm for keeping equipment's and batteries in the location box (FULL or HALF GKP /other type) with suitable varnish and anti-termite chemicals fitted on angles with nuts & bolts. Inspection: -Consignee (note-balance quantity may be taken from rly store if available) . A)950 x 400 x 25 MM for full size location box . | — | 40.00 | — | — | |
| — | — | — | 80,550 | ||
| Supply of paper base hylam sheet 12 mm thick. Inspection: consignee. | — | 15.00 | — | — | |
| — | — | — | 5,200 | ||
| "Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. NOTE: - The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) of Apparatus Case Full Size. (Outside & inside)" | — | 20.00 | — | — | |
| — | — | — | 91,440 | ||
| Supply of Medium class GI pipes 100 mm dia {4.5 mm thickness} as per IS 1239 (Part 1}: 2004 or Latest with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. | — | 120.00 | — | — | |
| — | — | — | 11,760 | ||
| Laying & Fixing of Medium class GI pipe 50/ 100 mm dia {4.5 mm thickness} as per IS 1239 {Part 1}: 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. GI Pipe Supplied By Rly. | — | 120.00 | — | — | |
| — | — | — | 8,22,000 | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Eastern Railway a n d instructions o f Railway Engineer at site. Note:-(a)for all trenches from distant signal t o home signal and t o relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. Of cables headway i s not available, 4 " o f 1:2:4 concreting should b e done. Note:-(b-1) payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. | — | 3000.00 | — | — | |
| — | — | — | 8,340 | ||
| Supply, Transportation at site and Installation of RCC cable route marker engraved and painted on both side along the route at every 30 meter and at route diversion. The cable marker shall be as per ER Drawing DRG NO. S.I.- S&T/1/2024(SHEET NO. 1) Technical Policy Circular -108 Dated-22.04.2024 or latest. The fixing work is to be done as per extant practice of E. Rly. and as per Railway site supervisor. | — | 20.00 | — | — | |
| — | — | — | 2,34,700 | ||
| Termination of new/ alteration of main/tail cables on the existing terminals/ fuse blocks in apparatus cases/battery boxes/ CT boxes/ cable termination racks as per approved circuit diagram. The terminal particulars are to be re-painted / corrected on the doors of apparatus cases/ battery boxes/cable termination boxes and FTOT index board as instructed byRailway representative at site. This work includes alteration of lettering / painting, closing the opening created for entry of new cables in the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks with cablecompound.[Paints, wire PVC3/0.75mm and 16/0.2mm copper,sealing compound, bricks, cement,river sand and all other required miscellaneous materials shall be supplied by the contractor]. | — | 5000.00 | — | — | |
| — | — | — | 23,528 | ||
| Supply of maintainer's furniture of godrej make or superior and each set consist of(i) executive revolving bearing series low back-floating chair with normal arms cushioned chair-01 Nos. (ii) Executive table size 1650x900x728 mm with 3 drawers one side locker- 01 no.(iii) visitor chair seat & back cushion with high density foam with plastic pvc handle capsule type painted back-03 nOS. | — | 1.00 | — | — | |
| — | — | — | 5,804 | ||
| Supply of Office Chair make Godrej CH-7B or similar of reputed brand. Inspection: Consignee | — | 2.00 | — | — | |
| — | — | — | 9,032 | ||
| Supply of Office Revolving Chair Godrej Make Model No.9U02R Bravo or Similar of reputed brand. Inspection: Consignee | — | 1.00 | — | — | |
| — | — | — | 25,772 | ||
| Supply of Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm) or Similar of reputed brand. Inspection: Consignee | — | 2.00 | — | — | |
| — | — | — | 34,326 | ||
| Supply of Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand. Inspection: Consignee | — | 2.00 | — | — | |
| — | — | — | 1,50,000 | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometre post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | — | 30000.00 | — | — | |
| — | — | — | 1,13,319 | ||
| Supply of Tools Kit for High frequency Digital Axle Counter Multi section. This includes Supply of Service test panel including meter for test of track equipment, tools for mounting and adjustment of track equipment and standard jig for drilling holes in rail. It should be as per Principal manufacturers (OEM) recommended list adequate for installation, day to day maintenance, and adjustment of indoor and outdoor gears. This shall also include kit for making and drilling of holes on rail. Note: (1) this also includes supply of cross talk measuring set as per RDSO SPEC. TC 45-88 or latest, dB meter for measuring attenuation loss & 500v insulation tester, dummy wheel, torque wrench (2) multimeter should be pure sine wave digital multimeter make Fluke Model 287/ Rishabh Model 28s. Each measuring tools & equipments to be supplied with OEM'S test certificate/ guarantee certificate (as applicable). Detail Specification of tools kit are provided in tender document. Inspection: Consignee | — | 1.00 | — | — | |
| — | — | — | 57,29,632.2 | ||
| Underground, Armoured, Unscreened Railway signaling cable (Heavy Duty) with high conductivity copper conductor of size 12 Core X 1.5 sq mm as per Specn. No.IRS: S-63/2014 (Rev.4.0) with latest Amdt.if any.Inspection: RDSO | — | 20.00 | — | — | |
| — | — | — | 12,09,132.57 | ||
| Supply of PVC INSULATED STEEL STRIP ARMOURED, UNSCREENED, COPPER CONDUCTOR OF SIZE 2 CORE X 10 SQ. MM POWER CABLE STANDARD 7 X 1.40 MM FOR RAILWAY SIGNALLING CONFIRMING TO SPEC. NO. IRS :S-63-2014 REV . 4.0 AND IS : 1554 ( PART-1) WITH LATEST AMDT. IF ANY. Inspection : RDSO | — | 3.00 | — | — | |
| — | — | — | 11,553 | ||
| PROVISION OF COMMUNICATION FACILITY (PA SYSTEM) DURING NON-INTERLOCKING PERIOD AND PROVISION OF TEMPORARY GOOMTIES - 4 NOS, CHAIRS - 12 NOS ; TABLE - 4 NOS FOR OPERATIONAL FACILITIES DURING NI PERIOD. ALL REQUIERD MATERIALS TO BE ARRANGE BY CONTRACTOR FOR THE WORK AS PER SITE ENGINEER. ALL REQUIRED MATERIALS TO BE SUPPLIED BY THE CONTRACTOR ON HIRING BASIS ALONG-WITH LIGHTINING ARRANGEMENT AT SITE, GOOMTIES AS PER SITE ENGINEER. A)STATION | — | 1.00 | — | — | |
| — | — | — | 7,669 | ||
| "Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn. No. IRS: 5-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/ RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 1.00 | — | — | |
| — | — | — | 17,749 | ||
| "Supply of PVC insulated multi strand, single core copper conductor of size 3/0.75 mm as per IS 694:20 10 and RDSO Specn. No.IRS: S- 76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 1.00 | — | — | |
| — | — | — | 42,000 | ||
| "Supply of 1 x 6 Sq.mm. (Red/Black/Green multi strand copper power wire as per IS:694:20 10 or latest, 84 conductor each dia 0.30mm +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn. No.IRS:5-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 1000.00 | — | — | |
| — | — | — | 17,447 | ||
| "Supply of Industrial vacuum cleaner wet & dry duty with 220 millibar vacuum pressure, air flow rate 54 Liters/sec, suction hose length 3.5-meter, floor nozzle size -350 mm, power cord length-10 meter with 01 no motor of 1350 watt capacity with container capacity 35 Liter with filter dust class - G2 & filter area - 1 sq. meter with stainless steel body & container and operated voltage - 230 V AC. Make- Eureka Forbes/Panasonic, Deerma/ Dyson /Inalsa or better." | — | 1.00 | — | — | |
| — | — | — | 1,53,400 | ||
| Sonel Color LCD Thermal imager 14000 Pixel., Model: Sonel KT 128, Category Name & Quadrant : thermal imager (Q2), Brand : Sonel Or Similar. Inspection : Consignee | — | 1.00 | — | — | |
| — | — | — | 94,960 | ||
| "Supply of Handheld Digital Earth Clamp Tester for clamp on earth/ground resistance measurement up to 1000 ohms. Accuracy 0.1 - 0.99 D: 1%, 1 - 49 D: 1.5% Also measure current leakage up to 20A. No spines required for measurement Model - DECT-2 or equivalent / higher version make Motwane/ Stanlay/ Fluke/Megger.Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee" | — | 1.00 | — | — | |
| — | — | — | 8,761 | ||
| Supply of Digital Earth Resistance Tester for measurement of earth resistance with 3.5 digital LCD, 12.5 mm screen segment and Range -0.5 Ohms to 500 Ohms. WACO or Similar make. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee | — | 1.00 | — | — | |
| — | — | — | 8,239.7 | ||
| Supply of Solder Soft for Smooth polished, oxide free, non-corrosive soft solder bar in ratio of 60% Tin & 40% lead with melting point between 180 to 190 degree Celsius & can be used for hot dip soldering conforming to IS:11516:2005. | — | 5.00 | — | — | |
| — | — | — | 12,840 | ||
| PROTEX 10 Meter (Length Of theTape) Pressure Sensitive Adhesive Plasticized Pvc Tapes having 20 mm Width Brand: PROTEX (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC511687754042921 dt.29/08/2023 , ISI marked pressure sensitive adhesive tape for electrical purpose (Plasticized PVC tape with nonthermosetting adhesive) flame retardant, 0.125 mm thickness, 20 mm width, length of rolls 10 mt rs And confirming to IS:7809 latest with amendments | — | 1000.00 | — | — | |
| — | — | — | 1,19,000 | ||
| "Supply of 1 x 10 Sq.mm. {Red/Black/Green} multi strand copper power wire as per IS:694:20 10 or latest, 140 conductor each dia 0.30mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/ RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 1000.00 | — | — | |
| — | — | — | 65,500 | ||
| "Supp1y of 1 x 16 Sq.mm. {Red/Black/Green} multi strand copper power wire as per IS:694:20 10 or latest, 126 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/ km and test parameters as per RDSO Specn. No.IRS: S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 500.00 | — | — | |
| — | — | — | 1,38,500 | ||
| "Supply of 1 x 25 Sq.mm. {Red/B1ack) multi strand copper power wire as per IS:694: 2010 or latest, 196 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.78 ohms/km and test parameters as per RDSO Specn. No.IRS:S- 76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/ RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 500.00 | — | — | |
| — | — | — | 88,500 | ||
| "Supp1y of 1 x 35 Sq.mm. {Red/Black/Green} multi strand copper power wire as per IS: 694:2010 or latest, 276 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.554 ohms/km and test parameters as per RDSO Specn. No.IRS: 5-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/ RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board." | — | 500.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CheckListAnnexItoVIIIUPDATED_1.pdf
ATTACHMENT
AnnexureIX.pdf
ATTACHMENT
Annexure-X.pdf
ATTACHMENT
Annexure-XI_1.pdf
ATTACHMENT
AnnexureV.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
Annexure-VIA.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
GCCwithCorrectionSlips1to10_1.pdf
ATTACHMENT
LabourCessAddendumCorrigendumslipno.4.pdf
ATTACHMENT
JPO-CABLEDIGGINGWORK-VICINITYOFUNDERGROUNDCABLE-SRDSTESRDEN-C-240124.pdf
ATTACHMENT
TermsofPayment.pdf
ATTACHMENT
Updatedtenderdocument.pdf
ATTACHMENT
NewEarthElectrodeDrawing1_1.pdf
ATTACHMENT
sketch-Foundation_1.pdf
ATTACHMENT
FoundationC-6-98_1.pdf
ATTACHMENT
foundationMain_1.pdf
ATTACHMENT
TECHNICALCIRCULARNO108-CableRouteMarkerPoli_250925_155743_1.pdf
ATTACHMENT
EarthElectrodeC-36_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .