| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | ₹32.3 L Quoted ₹33.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹35.3 L+₹1.4 L (3.98%)Rejected-Finance 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | ₹35.3 L+₹1.4 L (3.98%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹36.4 L+₹2.5 L (7.43%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | ₹36.4 L+₹2.5 L (7.43%) | L3 | Rejected-Finance Not Lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
26 Sept 2024, 6:10 pmClosed
GE NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
REPAIR REPLACEMENT OF CEILING FANS EXHAUST FANS GEYSERS SPIT WINDOW TYPE AIR CONDITIONERS WATER COOLERS DEEP FREEZER AND ALLIED WORKS UNDER GE NORTH BANGALORE
2024_MES_668256_1
8496
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BANGALORE
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹78,000
Yes
30 Oct 2024
30 Aug 2024
3 Oct 2024
30 Aug 2024
26 Sept 2024
12 Sept 2024
30 Aug 2024 - 12 Sept 2024
Amount
Inspection, taking down, dismantling of geysers of any type / capacity, cleaning, descaling, reassembling & reinstallation in the existing place incl hydraulic pressure test of container with hand operated hydraulic pump complete, brazing inner tank, internal wiring and reinstallation after necessary repair / replacement of old parts all as specified & as directed. Note :Supply only new parts will be measured and paid for separately.
Supply only stainless steel inner tank of capacity 25 ltrs unit including internaly assembly of any size and type complete all as specified & as directed.
Supply only internal assembly/apparatus rod unit of any size and type of capacity 25 ltrs complete all as specified & as directed.
Supply only stainless steel inner tank of capacity 50 ltrs unit complete with all fitting and fixtures all as specified & as directed.
Supply only internal assembly/apparatus rod unit of any size and type of capacity 50 ltrs complete all as specified & as directed.
Supply only heating element of 2 KW rating triangular/round type as per existing size and type including rubber washers all as specified & as directed.
Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
Supply only Thermostat/auto cut off of suitable for 25/50 Ltrs capacity of any size.
Supply only Indicator lamp red and green type square/round.
Supply only Safety valve/high pressure valve / NRV of exisitng type ISI marked.
Supply only PVC insulated Copper cable flexible 3 core of size 40/0.0076 ISI marked.
Supply only outer cover of geyser for capacity 25 ltrs unit complete with all fitting and fixtures as specified & as directed.
Supply only outer cover of geyser for capacity 50 ltrs unit complete with all fitting and fixtures as specified & as directed.
Supply only PVC flexible pipe 16mm dia 450mm long with 2 Nos of brass ferrule & rubber washer for hot and cold water all as specified & as directed.
Supply and Fix in Repair PVC flexible pipe 16mm dia 450mm long with 2 Nos of brass ferrule & rubber washer for hot and cold water all as specified & as directed.
Supply and Fix in Repair Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
Supply and Fix in Repair heating element of 2 KW rating triangular / round type as per existing size and type including rubber washers all as specified & as directed.
Supply and Fix in Repair element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
Supply and Fix in Repair Indicator lamp red / green type square/round.
M&L for Preparation old painted surface & painting the geyser complete after cleaning & applying one coat of spray paint of white enamel, writing MES No incluing taking down and refixing in same or other place complete all as specified & as directed by Engr -in-Charge.
Taking down ceiling fan 1200mm/1400mm and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, spray painting with one coat of synthetic enamel paint including writing MES NO, replacing the split pin, rubber pulley etc., refixing and connecting the same complete all as specified and as directed.
Inspection, disconnecting electric connecting and dismantling of ceiling fan / exhaust / wall mounted fan of any type / size, cleaning oiling, greasing the bearing, tightening of nuts and bolts, refixing complete after carrying out necessary repair / replacement of old parts all as specified & as directed. Note : Supply of parts shall be measured & paid separately.
Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting/exhaust fan including greasing complete all as specified and as directed.
Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed.
Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed.
Supply only PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust /wall mounting fans complete all as specified and as directed.
Supply only Rubber bush, set of MS bolts, nuts & washers with 'U' clamps for ceiling fans complete all as specified and as directed.
Supply only motor rotar ring for ceiling fans complete all as specified and as directed.
Supply only motor stator for ceiling fans complete all as specified and as directed.
Supply only down rod of 30/45 cm with nut, bolts and safety pin for ceiling fans complete all as specified and as directed.
Supply only plastic cup with screw for ceiling fans complete all as specified and as directed.
Supply and fix in repair capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
Supply and fix in repair capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed.
Inspection in position at site of the ceiling fan 1200 / 1400mm sweep of any make and type and do the necessary preventive maintenance like checking and replacing of split pins, nuts bolts and rubber bush and flexible wire complete all as specified and as directed. Note: Quoted rate is inclusive of spares and wire.
Dismantling / opening the ceiling fan of 1200 mm sweep of any make and type, removing the burnt winding carefully, cleaning the inner parts rewinding with the same gauge with super enamelled copper conductor of good insulation, varnishing, drying and reassembling / the same complete all as specified and as directed.
Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the burnt winding carefully, cleaning the inner parts rewinding with the same gauge with super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removingburnt winding carefully, cleaning the inner parts, rewinding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Taking down exhaust fans 230 mm/300mm / 450mm sweep from position after disconnecting electric lines, preparing the surfaces, filling cavities with filler, cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
Dismantling / opening exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old burnt winding carefully, cleaning the inner parts and rewinding with the same gauge with super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling / opening exhaust fan of 450 mm sweep of any make and type, removing burnt winding carefully, cleaning the inner parts and rewinding the same gauge with super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
M&L extension of down rod for ceiling fan upto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed.
S&F in replacement PVC Fresh air fan of 150mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
S&F in replacement PVC Fresh air fan of 200/225mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
S&F in replacement PVC Fresh air fan of 250/300mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
S&F in replacement of exhaust fans motor suitable for 280/300 mm sweep, heavy duty, 1400 RPM, AC single phase 230/240 V with blades complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
S&F in replacement of exhaust fans motor suitable 225/230 mm sweep, heavy duty, 1400 RPM, AC single phase 230/240 V with blades complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
S&F in replacement of exhaust fans outerframe for holding exhaust fan motor upto 280/300 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
S&F in replacement of exhaust fans outerframe for holding exhaust fan motor upto 225/230 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
S&F in repairs, louver of exhaust fan suitable for 300/230 mm sweep complete accessories all as specified and directed
S&F in repairs, louver of exhaust fan suitable for 450 mm sweep complete accessories all as specified and directed
Servicing of window type AC / split type AC of 1.0 / 1.5 / 2.0 ton capacity installed at site by cleaning the condenser and evaporator coil by blower, checking the cleaning wiring, replacement of burnt out wiring terminals, cleaning the air filter, adjustable relays etc, complete all as specified and as directed.
All as per item No 52 here-in-before, but for water coolers of any capacities
All as per item No 52 here-in-before, but for refrigerators/Deep freezer of any capacity
Removing the split type AC of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace with new factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position incl testing and commissioning complete all as directed for the following capacities:- 1.5 ton capacity
All as per item No. 55 above but for 2.0 ton capacity
All as per item No 55 here-in-before, but for water cooler/refrigerators/deep freezer of following capacities. 40/60/80 ltrs capacities water cooler
All as per item No. 55 above but for 120/150 ltrs capacities water cooler
All as per item No. 55 above but for 165/180 ltrs capacities refrigerators
All as per item No. 55 above but for 220 ltrs capacities Deep freezer
All as per item No. 55 above but for 286/310/320 ltrs capacities refrigerators / Deep freezer. Note for item No 52 to 61:- (i) Gas will be measured and paid separately for item No 52 to 61 under relevent item of this schedule. (ii) Spares cost more than 200 Rs will be measured and paid seperately under relevent item of this schedule.
Labour only forsplit / window AC for leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete for the following capacities: 1.5 Ton AC
All as per item No. 62 above but for 2.0 Ton AC
All as per item No 62 here-in-before, but for water cooler storage type of following capacities 40/60/80 ltrs capacity
All as per item No. 62 above but for 120/150 ltrs capacity water cooler
All as per item No 62 here-in- before, but for refrigerators / deep freezer 165 / 220 ltrs capacities
All as per item No. 62 above but for refrigerators / deep freezer of 286 / 310 / 320 ltrs capacities
Painting of water coolers with two coats of enamel paint of existing colour all as directed over a coat of primer after welding the base plate with MS angle iron frame of existing size removing dust, tinkering, applying metal putty wherever necessary incl writing of SM/MES No all as directed by Engineer-in-Charge for water coolers of following capacity:- 40/80 ltrs capacities
All as per item No. 68 above but for 120/150 ltrs capacities
Removing the unserviceable blower motor from the window type AC/Spilit type AC, removing the burnt out winding from slots, rewinding with superior quality copper winding wire of higher insulation level, varnishing drying the motor complete and fixing in position incl testing and commissioning for 1.5/2 ton capacity
All as per item No 70 above but for water cooler of any capacity
All as per item No 70 above but for refrigerators / deep freezer of any capacities
Removing the damaged/unserviceable fan blades from the condenser motor shaft and replace new fan blade of the same size and type for any capacity of window type AC and water coolers all as specified and directed.
Removing the unserviceable thermostat and Supply and fix new thermostat of same make and type for the following :- (Make- Indfos / Danfoss) Split / window type AC 1.5/2 ton capacity
All as per item No. 74 above but for Water Cooler 40/60/80 ltrs capacity
All as per item No. 74 above but for Water Cooler 120/150 ltrs capacity
All as per item No. 74 above but for Refrigerator 165/220 ltrs capacity
All as per item No. 74 above but for Refrigerator 286/310/320 ltrs capacity
Removing the unserviceable potential relay and Supply and fix relay of same make and type for the following:- Water cooler 40/60/80 ltrs capacity
All as per item No. 79 above but for Water cooler 120/150 ltrs capacity
Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for water cooler upto 120/150 Ltrs capacity and testing complete all as directed.
Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for refrigerator/Deep Freezer 165/175/286/310/320 Ltrs capacity and testing complete all as directed.
Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for Split/window type AC of 1.5/2 Ton capacity and testing complete all as directed.
Removing the unserviceable LMS from the refrigerator Supply and fix new relay of same make and type for refrigeraters/ deep freezes of following capacities:- 165/175/220 ltrs
All as per item No. 84 above but for 286/310/320 ltrs
Removing / dismantling unserviceable evaporator freezer box unit incl door cover and providing new & connecting the refrigerant pipe lines, peak testing, vacuuming and gas charging the unit with required quantity of refrigerant for refrigerator of 286/310 ltrs capacity and testing complete all as directed.
All as per item No 86 here-in-before, but for refrigerator of 165/175/220 ltrs capacity
Removing the damaged / unserviceable refrigerator / Deep freezer magnetic gasket of door and replacing with new door gasket of same type and size incl making good the surfaces for proper seating of the door for the following capacities 165/175/220 ltrs
All as per item No. 88 above but for 286/310/320 ltrs
Removing the unservicable running capacitor of 40 MFD, Supply and fix of new capacitor suitable for 1.5 ton AC make :- BHEL / EPCOS/ TDK/ TIBCON or equivalent.
All as per item No 90 herein before, but starting capacitor of 80/100 MFD for 2 TR AC.
All as per item No 90 herein before, but starting capacitor of 60/80 MFD for water cooler.
Removing the unservicable over load protection and Supply and fix new over load protector for split/window type AC of 1.5/2.0 TR capacity.
Removing the unservicable PVC ball valve 15mm dia incl float and replace with new PVC ball valve of 15mm dia for water coolers of any make and size all as specified and directed.
Removing the unservicable PVC flexible pipe and Supply and fix new PVC flexible pipe of existing size for water outlet of water cooler/AC.
Disconnecting and removing the damaged unservicable supply cord for cooling appliances and Supply and fix new PVC insulated 3 core 2.5 Sqmm multi stranded copper conductor cable complete all as directed.
S&F in replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amps.
Supply and fill refrigrent gas (R-22 / 410A / 134A) for cooling appliance.
Disconnecting and taking out the unservicable sensor/remote unit completely and supply and fix new sensor unit of indoor unit of AC to suit the AC of Makes carrier/Bluestar/Voltas 1.5 Ton Split type AC
All as per item No. 99 above but for 2 Ton Split type AC
Disconnecting and taking out the unservicable PCB, refixing new PCB for split AC / window AC any type and any make all as specified and as directed. 1.5 Ton AC
All as per item No. 101 above but for 2 Ton AC
Disconnecting and taking PCB circuit of disconnecting out PCB from split AC, repairing the same and refixing in original location complete all as specified and directed for 1.5/2 Ton capacity all as directed.
Disconnect electrical connection, removing copper line, discharge line of split type AC upto 2 Ton capacity including indoor and out door units and all accessories and shifting/reinstalling and testing the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls complete all as specified.
Supply and fix voltage stabilizer suitable for water cooler of 1 KVA capacity complete all as specified and as directed. Make : V Guard / Everest / Sinotech
All as per item No. 105 above but for 2 Ton AC
All as per item No. 105 above but for 1 / 1.5 Ton AC
S&F ceiling fans complete with complete accessories, 230V, SP 1200 mm Sweep with BEE 3 Star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed .Make Bajaj, SABSE TEZZ EE 03. Model No 251120 and equ on Havells/CG/ USHA.
S&F in replacement of brass flare nuts suitable for 1.5/2 ton of Split AC complete all as specified and directed.
S&F in replacement of brass angle valve for gas charging for split AC 1.5/2 ton of AC compete all as specified and as directed.
S&F in replacement of MCB single pole 240 volts 20/25 Amps complete all as specified and as directed
S&F Storage type water heater 25 Ltrs BEE 5 star rated complete incl steel wired pipe for hot/cold water connection for inlet and out let water etc complete all as specified and directed at site. Make Bajaj. Model No CALENTA 150801 or eqv on Venus / Havells)
S&F in replacement of swing motor of existing capacity and type for indoor unit of split AC fins complete all as specified and as directed
S&F in replacement of MS fabrication clamps for hanging, fan including hook as existing complete all as specified and as directed
S&F in replacement of Nitrile rubber insulation for suction and dischaged pipe of split type AC of size 15/19 mm dia complete all as specified and as directed.
S&F in replacement of Soft copper tubbing 15mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
S&F in replacement of Soft copper tubbing 19mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, call bell socket or power circuits) complete and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
Vasavi Electricals (BID ID -3100676)
GS TRADERS (BID ID -3099583)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .