Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹3.9 L+₹2,523.36 (0.66%)Accepted-Finance | L2 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹7,400
Closing Date
17 Mar 2022, 11:15 amClosed
Executive Engineer (EnM) M-07
Office of the Executive Engineer (EnM) M-7 Nangloi Phase-III, Near Surajmal Statdium Metro Station New Delhi-110041.
Internal and External Electrification at water emergency and OHT BPS L Block in AC 12 Mangol Puri.
2022_DJB_218751_4
e-NIT No.06 / (EnM) M-7/ 2021-22
Open Tender
Miscellaneous Works
Works
45 days
Nangloi Ph-III EE EnM M-7
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
Account No SB 50448339804
₹7,400
Yes
23 Mar 2022
10 Mar 2022
17 Mar 2022
10 Mar 2022
17 Mar 2022
10 Mar 2022
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. SOR 31.1.2
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. SOR 31.31
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. SOR 31.32
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. SOR 31.12
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. SOR 31.26
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. SOR 31.25
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. SOR 31.44
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. SOR 31.41
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. SOR 31.50.1
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. Make : - Havells / Gloster / Grandley / Approved By DJB SOR 31.14.2
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single pole, make L&T / Havells / C&S / Approved by DJB SOR 32.10.1
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (2 + 16), Double door. SOR 32.3.4
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 A, L&T / Havells / C&S / Approved by DJB SOR 32.12.1
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. SOR 35.1.4
Supply of PVC/XLPE insulated(HEAVY DUTY), electrical cable for working voltage up to and including 1100vpolts to IS :1554(part-I) 1988/7088/7098(part-I) 1988 with Copper conductor, Armoured of 2X10 Sq MM Make: - Gloster, Grandlay, Havels, Polycab SOR 18.9.5
S/o. Decorative ultra slim profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. Lamp make: Havells/ Crompton/ Bajaj/ Philips Type Order 18 Watt SOR 19.1.1
S/o ceiling fan, 1200 mm sweep make: Havells / Crompton SOR 20.1.1
Supply of exhaust fan heavy duty 1400 RPM size 450 mm, Make: Havells/ Crompton/ Almonard SOR 20.2.3
Supply of 450 MM air circulator Make: Havells/ Crompton/ Almonard SOR 20.3.1
New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07.. 70/72 watt Make: Bajaj / Havells / Philips / Approved by DJB SOR 19.10.6
Raj Engineering Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .