Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹43.1 L+₹1.1 L (2.55%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹43.4 L+₹1.3 L (3.16%)Rejected-Finance P O CHAMURCHI BAZAR CHAMURCHI DIST JALPAIGURI | CHAMURCHI | JALPAIGURI | WEST BENGAL | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹43.7 L+₹1.7 L (3.97%)Rejected-Finance C O PULAK SAHA MAHAKAL PALLY SURYASEN PARK MAIN GATE SILIGURI 734001 DIST DARJEELING | JALPAIGURI | WEST BENGAL | 734001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹44.2 L+₹2.2 L (5.16%)Rejected-Finance SREE COLONY BAGDOGRA PO BAGDOGRA DIST DARJEELING WB | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
11 Aug 2021, 6:00 pmClosed
GE SEVOKE ROAD
GE SEVOKE ROAD POST SALUGARA DIST JALPAIGURI
REPAIRS TO LEAKAGE SEEPAGE SHAFT AND TILING AND CONNECTED WORKS OF OTM ACCN OF ZONE A AREA AT SEVOKE MIL STN UNDER GE SEVOKE ROAD
2021_MES_460303_2
GE/SEV/17 OF 2021-22
Open Tender
Civil Works
Item Rate
270 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹88,000
Yes
4 Sept 2021
30 Jul 2021
13 Aug 2021
30 Jul 2021
11 Aug 2021
6 Aug 2021
30 Jul 2021 - 31 Jul 2021
Amount
Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of reinforced cement concrete work, RCC tank of any description and in any position not otherwise specifically provided for all as specified.
M&L for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class "B" bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified.
M&L for 20 mm thick rendering in CM 1:4 in two layers of 10mm each using water proofing compound in top layer only including finishing the surface even and fair(WPC shall be measured and paid seperately) complete all as specified and as directed
Supply only water proofing compound (integral) complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down 20 mm bore steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down 25 mm bore steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified.
S&F 15 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed.
S&F 20 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed.
S&F 25 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of weather resistant acrylic emulsion paint over a coat of primer complete all as specified and directed. .
Disconnecting existing tanks, setting aside (or lowering if required) of any capacity for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (including Cleaning, repairing, etc.)
M&L for precast cement concrete, 1:2:4 type B1 (Using 20 mm stone aggregate) as in slabs, landings, etc. including formwork complete all as specified and directed
M&L for mild steel TMT bar 5mm dia and over and including 10mm dia as in stirrups, spacer bars and binders complete all as specified and directed
Demolition of brick coba/cement concrete (unreinforced) from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retreived debris in low lying area complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope including making rounded or chamfered on edges mixed with WPC @2% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only complete all as specified and directed
M&L for 15mm thick rendering in CM (1:4) over RCC roof surface to receive roof treatment finished even and smooth without using extra cement mixed with water proofing compound as per manufacturers instruction (WPC shall be measured and paid separately).
M&L for providing, laying water proofing treatment over plastered surfaces of RCC roof shall be as under:- (a) The dried plastered surface of slab shall be painted with one coat of bituminous primer @0.4 liter/Sqm. (b) Over the primed surface a layer of APP based polymeric membrane minimum weight of 3 kg/sqm of approved manufacturer minimum 3mm thick, reinforced with polyster non woven fabric (weighing not less than 160gms/sqm) shall be laid by torch application method. The side over laps of membrane shall be minimum75mm and the end laps shall be minimum 100mm and sealing all overlaps and joints shall be done as per manufacturer's instruction. (c) The finished surface shall be given Aluminium paint @ 0.11 Kg/Sqm on APP as per manufacturer's instructions. Make:-M/S TEXSA INDIA LTD (MOPLY-FP) / M/S STP LIMITED (SUPER THERMOLAY) / IWL INDIA LIMITED (HYPERPLAS)/M/S Tiki Tar Danosa (India) Pvt Ltd (Hydro Stop)/M/s Supreme Bituchem India Pvt Ltd (Super Shield)
M&L for treatment of sunken floor slab compraises of the following specifications and all as specified.:- Note:- Cost of the following specification shall be included in the quoted rate.
M&L for cleaning the sunken/ lowered portion of RCC slab surface (including vertical total depth plus skirting height ) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely . 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope includiing cutting holes in bricks or RCC wall for spout.
M&L rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed , nozzles shall be fixed and grouting carried out (WPC shall be measured and paid separately )
All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty.
After drying putty , wash the slab and sides of sunken portion with water and make it clear and clean.
M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level +100mm height . The thickness of two layer shall be 1mm . When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per menufacturer's specification including rounding of corners and junctions sloping towards spout ( WPC Shall be measured & paid separately)
Note :- Test the water proofed area (ponding test ) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE . Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is inclued in the rates quoted.
All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint.
Two nos 50mm bore GI pipe medium grade 600mm long spout shall be provided through external wall to drain out accumulated water.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed
M&L for non skid coloured ceramic tiles of 7 to 8 mm thick (square/rectangular) area exceeding 0.06 sqm but not excdeeding 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles including 20 mm thick screed bed or beding layer of CM 1:6 for fixing of tile in skirting complete all as specified and as directed
M&L for glazed coloured ceramic tiles of size 450x300x 7mm thickness in vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles including 10 mm thick backing layer of CM 1:3 for fixing of tiles on wall complete all as specified and as directed.
S & F Vitreous China, semi-pedestal pattern (EWC) excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed.
S&F PVC connection pipe 15 mm dia, 450 mm long with PTMT nut complete all as specified and as directed
S & F in repairs flushing cistern, 10 Ltrs. Capacity, PVC valveless, syphonic action type with dual flushing system, low level,white with inlet, ball valve,float and handle including brackets, flush pipe of polyethylene PVC 32mm dia, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
S & F 110 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door complete all as specified & directed.
S & F 110 mm bore PVC (SWR) Vent cowl complete all as specified & directed
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
S & F 75 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door complete all as specified & directed.
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified & directed
M& L provinding precast cement concrete louvers and jallies, 50 mm thick (measured solid) including all mouldings but excluding frame type B-0 1:2:4 (12 mm graded crushed stone aggregate ) set in cm 1:4 complete all as specified and directed.
S&F bib tap 15 mm bore cast copper alloy chromium plated, fancy type with capstan head wall flange screwed down screed for iron pipe complete all as specified and as directed.
S& F 15 mm bore angle stop valve cast copper alloy chromium plated fancy type with capstan head, wall flange screwed down screwed for iron pipe and fixed in repairs complete all as specified and as directed.
S&F concealed 15 mm angle stop valve cast copper alloy, chromium plated, fancy type with capstan head, wall flange screwed down screwed for iron pipe and fixed in repairs complete all as specified and as directed.
M&L for PVC (SWR) floor trap plain with grating including jointing with solvent cement of diamemeter ,75mm complete all as specified and as directed.
Cutting chases in brickwalls girth exc 10 cm but n exc 20 cm , pinning in making good to facings where required and pointing in cement mortar 1:3 for conceled water tubing etc and making good complete all as specified.
S&F in repairs vitreous china squatting pan "ORISSA" patern of size 580x440mm white, with integral foot rests (excluding flushing cistern & flush pipe) including provisioning of lime concrete bedding complete all as specified.
S&F 15mm bore CP Toilet Hand Pressed Nozzle (Heath faucet) with 1.5 mtr long tube with CP wall bracket including taking down the old one complete all as specified and as directed.
S&F in repairs CP brass overhead shower 80mm dia round shape with and including CP brass shower arm 240mm long with wall flange complete all specified and directed.
S&F in repairs 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball for iron pipe complete all as specified and directed.
S&F 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball for iron pipe complete all as specified and directed.
S&F in repairs 25 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball for iron pipe complete all as specified and directed.
S&F 25 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball for iron pipe complete all as specified and directed.
M&L for applying two coats of Synthetic Enamel paint on newly primed Steel surfaces exc 10 cm in width or girth complete all as specified and directed.
S&F pre-painted Galvalume Aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colur having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F pre-painted Galvalume Aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F rolled mild steel section any type including hollow section as in main and cross beams, hip and jack rafter purlins where conncected to common rafter and running rails and guide for sliding doors fixed with angle cleats or other connectiing plates FE 290 Gde E-165 complete all as specified and directed..
M/S HARMANS
JHA CONSTRUCTION AND CO
MARWA CONSTRUCTION
M/S S.B. CONSTRUCTION
SRI SURAJIT SENGUPTA
ASSOCIATED TRADING CORPORATION
SHRI JAYANTA GHOSH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .