Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 626 6TH FLOOR DLF TOWER A DLF TOWER 626 6TH FLOOR DLF TOWER A JASOLA JASOLA SOUTH DELHI DELHI 110076 | SOUTH DELHI | DELHI | 110076 | Admitted-Finance |
| 4 | Admitted-Finance FLAT NO 5 IIND FLOOR IIIRD B 2 NEHRU NAGAR GHAZIABAD UP 201001 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201001 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹21.0 L
Closing Date
5 Jul 2021, 6:00 pmClosed
Superinteng Engineer ( Contracts-II)
MM Building, Old Power House Premises, Banim Park, Jaipur-302006 (Rajasthan)
Construction of 400kV and 220kV Bays and ETC of 500 MVA transformer at Hindaun
2021_RRVPN_224422_1
RVPN/ SE(Contracts-II)/BN-9019002101
Open Tender
Electrical Works
300 days
jaipur
Please refer Tender documents.
22 documents required · 22 mandatory
₹17,700
as per bid document
₹21.0 L
Yes
Jaipur
3 Sept 2021
2 Jun 2021
6 Jul 2021
2 Jun 2021
5 Jul 2021
10 Jun 2021
7 Jun 2021
Amount
Substation Equipments with connectors & necessary spares:
400kV, 3 pole Circuit Breaker (3-phase)
400 KV CT's (1-phase) Ratio 500/1000/2000/1A, 5C
LA's for 400kV System (1phase)
400kV Motor operated Isolators with single EB(3-phase) 2000A
400kV Motor operated Isolators with double EB(3-phase) 2000A
Marshling Kiosks (MK) for 400kV system
400kV Contol and relay panel with SCADA enabled with necessary spares relay kit:
i) For transformer Type- R7A,7B,7C
iii) For Tie Breaker typr- R8A,8B,8C
400kV Bus-bar Protection scheme for the complete system
400 KV Sub Station Structures
Beam 400 KV (24 Meter)
PI Stru.
400 KV Iso. Stru.
400 KV CT Structure
400 KV LA Structure
Insulators
400 KV Post Insulators along with corona rings & connectors
FOR 400 KV SUSPENSION long road insulators
FOR 400 KV TENSION long road insulators
400 KV Bus hardware, Clamps & Connectores various types suitable for moose conductor and pipe buses
Bus Bar Spacer suitable for 400 KV buses of moose conductor
220 KV Substation Equipments with connectors & necessary spares:
220 KV Circuit Breakers.
220 KV CT's (1-phase) 500/1000/2000/1A, 5C for T/F I/C
220 KV LA's (1-phase) for TF.-LA
220 KV motor operated Isolators without EB (3-phase) 2000A
220 KV motor operated Isolators with single EB (3-phase) 2000A
220 KV motor operated Tandem Isolators (3-phase) 2000A
Marshling Kiosks (MK) for 220kV system
220 KV control & relay panel with SCADA enabled with necessary spares relay kit: :-
i) for220 KV side of 315 MVA Power transformer
220kV Bus-bar Protection scheme for the complete system
220 KV Sub Station Structures
AO5(LA Structure)
AO3 (CT Structure)
AOI (Iso. Structure)
AIO(T) ( Tendam Iso. Structure)
PIS Stru.
AB2 Beam (16.6 Mater)
Insulators
220 kV Post Insulators along with corona rings & connectors
FOR 220 KV SUSPENSION long road insulators
FOR 220 KV TENSION long road insulators
220 KV Bus hardware, Clamps & Connectores various types suitable for tarantulla conductor and pipe buses
Bus Bar Spacer suitable for 220 KV buses of Tarantulla conductor
FRLS Power Control Cables
18 CORE * 2.5 SQ MM
12 CORE * 2.5 SQ MM
6 CORE * 2.5 SQ MM
4 CORE * 4 SQ MM
4 CORE * 2.5 SQ MM
EARTHING MATERAL
MS FLAT 75*12 MM
MS ROD 40MM
M.S CHANNEL 100*50*6 MM
ACSR Moose Conductor
AAC Tarantulla Conductor
Earth wire connectors & H/W
Fire fighting system (Hydrant System for Bays)
Yard Lighting system
Any Other item required for successful completion of work
Description of Work / Item(s)
Amount
ETC of Transformer
Erection, testing & commissioning of 400/220kV, 500 MVA Power Transformer with all accessories and including Fire Fighting (HVWS) System Neutral CT, Bushing CT (BCT), On-line incipient fault monitor, Tertiary and Neutral connection, 33kV tertiary equipments and arrangement etc.
Shifting work of existing 8 Nos, CVT's by dismantaling and re-erection at new location alonwith structure & civil work due to extension of 400 KV Buses (Main Bus-I & Main Bus-II) in all respects.
Shifting work of existing 8 Nos, 400 KV Isolators by dismantaling and re-erection at new location alonwith structure & civil work due to extension of 400 KV Buses (Main Bus-I & Main Bus-II) in all respects.
Complete work of extension of 400 KV Main Bus-I & Main Bus-II in all respects inclding conductor, clamps & connectors, hardwares, etc. .
Modification work for using existing 220 KV Bus Coupler Bay as 220 KV Transformer Bay (I/C) alongwith construction of 220 KV Bus Coupler Bay at new Location in all respects
Complete work of extension of 220 KV Main Bus-I, Main Bus-II & 220 KV Aux. Bus in all respects inclding conductor, clamps & connectors, hardwares, etc. .
Substation Equipments with connectors & necessary spares:
400kV, 3 pole Circuit Breaker (3-phase)
400 KV CT's (1-phase) Ratio 500/1000/2000/1A, 5C
LA's for 400kV System (1phase)
400kV Motor operated Isolators with single EB(3-phase) 2000A
400kV Motor operated Isolators with double EB(3-phase) 2000A
Marshling Kiosks (MK) for 400kV system
400kV Contol and relay panel with SCADA enabled with necessary spares relay kit:
i) For transformer Type- R7A,7B,7C
iii) For Tie Breaker typr- R8A,8B,8C
400kV Bus-bar Protection scheme for the complete system
400 KV Sub Station Structures
Beam 400 KV (24 Meter)
PI Stru.
400 KV Iso. Stru.
400 KV CT Structure
400 KV LA Structure
Insulators
400 KV Post Insulators along with corona rings & connectors
FOR 400 KV SUSPENSION long road insulators
FOR 400 KV TENSION long road insulators
400 KV Bus hardware, Clamps & Connectores various types suitable for moose conductor and pipe buses
Bus Bar Spacer suitable for 400 KV buses of moose conductor
220 KV Substation Equipments with connectors & necessary spares:
220 KV Circuit Breakers.
220 KV CT's (1-phase) 500/1000/2000/1A, 5C for T/F I/C
220 KV LA's (1-phase) for TF.-LA
220 KV motor operated Isolators without EB (3-phase) 2000A
220 KV motor operated Isolators with single EB (3-phase) 2000A
220 KV motor operated Tandem Isolators (3-phase) 2000A
Marshling Kiosks (MK) for 220kV system
220 KV control & relay panel with SCADA enabled with necessary spares relay kit: :-
i) for220 KV side of 315 MVA Power transformer
220kV Bus-bar Protection scheme for the complete system
220 KV Sub Station Structures
AO5(LA Structure)
AO3 (CT Structure)
AOI (Iso. Structure)
AIO(T) ( Tendam Iso. Structure)
PIS Stru.
AB2 Beam (16.6 Mater)
Insulators
220 kV Post Insulators along with corona rings & connectors
FOR 220 KV SUSPENSION long road insulators
FOR 220 KV TENSION long road insulators
220 KV Bus hardware, Clamps & Connectores various types suitable for tarantulla conductor and pipe buses
Bus Bar Spacer suitable for 220 KV buses of Tarantulla conductor
FRLS Power Control Cables
18 CORE * 2.5 SQ MM
12 CORE * 2.5 SQ MM
6 CORE * 2.5 SQ MM
4 CORE * 4 SQ MM
4 CORE * 2.5 SQ MM
EARTHING MATERAL
MS FLAT 75*12 MM
MS ROD 40MM
M.S CHANNEL 100*50*6 MM
ACSR Moose Conductor
AAC Tarantulla Conductor
Earth wire connectors & H/W
Fire fighting system (Hydrant System for Bays)
Yard Lighting system
Any Other item required for successful completion of work
Civil works
Foundations
Transformer
400/220kV, 500 MVA Power Transformer with all accessories and including Fire Fighting (HVWS) System Neutral CT, Neutral CT, Bushing CT (BCT), On-line incipient fault monitor, Tertiary and Neutral connection, 33kV tertiary equipments and arrangement etc.
400 KV Sub Station/Equip. Structures
PI Stru.
400 KV Iso. Stru.
400 KV CT Structure
400 KV LA Structure
400kV, 3 pole Circuit Breaker (3-phase) Str
220 KV Sub Station Structures
AO5(LA Structure)
AO3 (CT Structure)
AOI (Iso. Structure)
AIO(T) ( Tendam Iso. Structure)
PIS Stru.
220 KV Circuit Breakers.
CABLE TRENCH
Design, engineering and construction of R.C.C. cable trenches for required depths precast R.C.C. covers, water stops, brick works wherever required including the supply of labour, material, cement, reinforcement steel, steel angles, flats and providing P.C.C.(1:4:8) below cable trenches as per technical specification and approved drawings
Section B
Section C
Section D
Sump pits with a provision of automatic dewatering pumps
CABLE TRENCH CROSSING
Design, engineering, construction including supply of labour, material, cement, reinforcement steel, form work etc. and all associated works for construction of cable trench crossings as per technical specification and approved drawings
Section B crossing road
Section C crossing road
Section D crossing road
Sump pits with a provision of pumps
ANTIWEED TREATMENT
Providing and supplying all labour material including borrowed / removal of earth for maintaining the FGL, equipments etc., removal of weeds, soil sterilization / antiweed treatment including excavation, mixing / injecting chemicals to achieve the guaranteed effectiveness of treatment at least up to one years, rolling dressing, compacting the excavated earth within substation areas as per technical specification .
JELLY SPREADING
a) 100mm thick layer of granite/basalt/trap jelly of 20mm size shall be spread over the entire switchyard area as per drawing and directions of engineer in-charge of the work. The 20mm nominal size shall pass 100% through IS. Sieve designation 40mm and nothing through 16.00mm IS Sieve. The whole switchyard area (excluding buildings pathway road, drainages, cable trenches, equipments/ structures plinths etc) shall be covered with jelly spreading. The jelly used shall be free from dirt, organic materials and flakes b) Barricades shall be provided to confine Jelly Spreading which include construction of solid concrete block masonry in CM (1:6) with cement concrete solid blocks of proportion (1:5:3) crushing strength not less than 50 Kg. per Sq.cm / 40x40x20 cms. Size (l, b, h) conforming to IS 32185-196) including necessary curing etc. complete. The concrete block shall be 100 mm above gravel top. The exposed surface of barricades shall be plastered with 12 mm thick in cm (1:6) & two coat of water proof cement paint.
ROAD WORK
Design and construction of roads and walkways/shoulders within sub-station or outside the station as per specification, layout, sectional detail drawing and directions of Engineer-in-charge of work etc. complete in all respect.
a) 5.00 Mtr. Wide Road.
b) 3.75 Mtr. Wide Road.
Kiosk Building
Design and construction of Kiosk as per specifications complete in all respect
a) 400 KV Kiosk.
b) 220 KV Kiosk.
Any Other item required for successful completion of work
JSP Projects Pvt Ltd
Jakson Limited
Sumaja Electroinfra Private Limited
GEPDEC INFRATECH LIMITED
JSP Projects Pvt Ltd
GEPDEC INFRATECH LIMITED
Jakson Limited
Associated Power Structures Pvt. Ltd.,
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid