| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹23.9 L+₹1.0 L (4.56%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹24.3 L+₹1.5 L (6.66%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹24.4 L+₹1.6 L (6.85%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹24.5 L+₹1.7 L (7.52%)Rejected-Finance 1331 GENERAL GANJ OPP WATER TANK MATHURA 281001 | MATHURA | UTTAR PRADESH | 281001 | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
12 Sept 2020, 6:00 pmClosed
GE EAST AGRA
Garrison Engineer East Agra, Gwalior House, 62 Taj Road Agra Cantt
REPAIR REPLACEMENT OF LEAKAGE SEAPAGE SUNKEN FLOOR GI PIPE AND SERVICE TANK DAMAGE ROOF SHEETS AND ROOF TREATMENT ETC IN AATS UNDER AGE BR I OF GE EAST AGRA
2020_MES_371338_1
9270/E8
Open Tender
Civil Works
Works
180 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹50,000
Yes
24 Oct 2020
22 Aug 2020
19 Sept 2020
22 Aug 2020
12 Sept 2020
7 Sept 2020
Amount
Demolition of brick tiles or terracing tiles single layer on roofs complete including removal of debris away from the site etc complete all as specified and directed.
Demolition of Mud of any thickness including plastering and leeping on roofs complete including removal debris away from the site etc complete all as specified and directed.
Demolition of concrete in any description and in any position (unreinforced) complete all as specified and directed.
M&L for applying 15-20 mm screed with polymer modified non reactive mortar with fibre mortar mixed with cement and sand at site to produce a thixotropic mortar applied by shortcrete concrete machine .the product shall achieve a compressive strength of 15 Mpa in one day and 45 MPa in 28 days and a flextural strength of 7 MPa @7 days . it shall be compensate both plastic and Hardened shrinkage and have minimum direct adhesive bond strength of greater than 2 MPa it shall be alkaline ,compatiable with host concrete with similar thermal properties and shall achieve a elastic modulus of minimum 25 KN/ Sqm complete all as specified and directed by Engineer- in- Charge. Note:- Quoted rate shall be inclusive of all labours tools and plants scaffolding and working up to 15 mtr height and all safety measures like safety belt , ropes, helmats netting etc which are required for safety of working at height 3 to 25 mtr shall be mendatory and deemed to inclusive of quoted rates. Make:- Cipy polyyurethane/Thermax Ltd/ Kryton Build Mat Pvt Ltd/Carlisle Syntec.
M&L for providing PCC (1:2:4) Type B-1 using 20mm graded stone aggregates as in mass concrete,padding etc. complete all as specified and as directed
S&F 4 mm dia mild steel wire fabric weight not exc 4Kg /Sqm as extra reinforcement to RCC members like roof, ceiling, chhajas, beams, columns, parapet walls, waste slab etc including all cutting and waste complete all as specified and directed
M & L rendering 20 mm thick in C M 1:4 on concrete surfaces as in roof with chicken wire mess reinforcement and liquid water proofing compound as per manufacturer instruction complete all as specified and directed. (Note :WPC shall be measured and paid seperately)
Supply only liquid water proofing compound
M&L cutting out crack to V section in existing roofs or terracing cleaning out wetting grouting with cement and sand mortar 1:3 complete all as specified and directed.
M&L PCC 1:2:4 type B-0 using 12.5mm stone aggregate as in fillets junction of roof and parapet wall, caving slightly chamfered or rounded complete all as specified and directed..
S & F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall (110mm bore ) complete all as specified and directed.
S&F in repairs PVC (SWR) bends with access door any radius 110mm dia complete all as speified and directed
Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 10 mm thick on any faces of brick work in CM 1:6 finished even and fair complete all as specified and directed.
M&L for rendering 15 mm thick on any faces of brick work in CM 1 :4 finished even and fair complete all as specified and directed.
M & L rendering 10 mm thick in C M 1:4 on concrete surfaces as in ceiling complete all as specified and directed.
M & L rendering 10 mm thick in C M 1:4 on roof projection, chajjas of height exc 3.5m incl necessary scaffolding/centering etc complete all as specified and directed.
M & L for three coats of white wash on new plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
M & L for 2 coats of Oil bound Distemper over priming coat on walls including preparation of newly plastered surfaces complete all as specified and directed.
M&L for preparation of new surfaces and applying two coats of weather proof paint on walls tinted or white over chalk whitening s complete all as specified and as directed.
M&L for preparation of old surfaces by complete removal of existing treatment by rubbing down, washing and scraping of distempered and painted surface etc and applying two coats of weather proof paint on walls tinted or white over chalk whitening s complete all as specified and as directed.
M&L for preparation of old surfaces by complete removal of existing treatment by rubbing down, washing and scraping of distempered and painted surface etc and applying two coats of Oil bound Distemper on walls tinted or white complete all as specified and as directed.
M&L for a coat of Birla/ JK wall putty complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars , etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
M & L for brick work with old size sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class ‘B’ old size bricks straight or curved on plan to any radius as in half brick thick wall built in CM 1:4 complete all as specified and directed
S&F in repair 500 ltr capacity Rotational moulded polyethylene water storage tanks with cover (cylindrical vertical with closed top) hoisted and fixed in position incl disconecting of existing tank all as specified in SSR Part I including ball valve PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed for 20mm bore dia of pipe complete all as specified and directed.
S&F in repair 1000 ltr capacity Rotational moulded polyethylene water storage tanks with cover (cylindrical vertical with closed top) hoisted and fixed in position incl disconecting of existing tank all as specified in SSR Part I including ball valve PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed for 20mm bore dia of pipe complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and refixing in position.(Capacity in litres exc 250 & n exe 500) complete all as specified and directed.
S & F in repair 20mm dia bore Stop valves of PTMT any colour high pressure screwed for iron pipe or for unions and fixed complete all as specified and directed.
S & F in repair ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed for 20mm bore dia of pipe complete all as specified and directed.
Taking up or down 15 mm bore dia steel tubing and connections complete all as specified and directed.
Taking up or down 20 mm bore dia steel tubing and connections complete all as specified and directed.
S&F 15mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20 mm dia tubes medium galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Refixing 15 mm dia old steel tubing and connection in new or old position walls, ceiling, floors, etc.complete all as specified and directed Note:- Serviceable GI pipe obtained from item No 32.00 shall be reused after cleaning.
Refixing 20 mm dia old steel tubing and connection in new or old position walls, ceiling, floors, etc.complete all as specified and directed Note:- Serviceable GI pipe obtained from item No 33.00 shall be reused after cleaning.
Demolition of cement concrete(reinforced) of any description and in any position not otherwise specifically specified incl removal of the rubbish to a distance n. exc 100m complete all as specified and as directed by Engr-in-charge.
S&F Joist, channel, angle or tee sections of GDE FE-410-W or FE-250-W fixed independently without connecting plates (cut to ordinary lengths i.e within 20mm of the length indicated) complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surface over 10 cm width or girth including preparation of new or previously untreated steel surfaces complete all as specified and directed
M&L for 40-45mm thick sand stone slabs in sun shades, chajjas, shelves, cills, landings, cover stones, templets incl cutting chases, pinning in brick work etc n. exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and as directed.
Dismantling Structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
Dismantling framed trusses etc complete all as specified and as directed.
S&F framed work such as gates, doors of angle iron or other section of MS including pintel hinges, stops, hung as gate, hand made sliding bolt etc confirming to Fe-410-O of Fe 310-O complete all as specified and as directed.
M&L for preparation of old or untreated steel surface of any description and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for 1.25 mm thick mild steel black sheet as in steel gate and similar works cut to size, holes punched including round headed screw welded etc complete as specified and as directed.
S&F 0.56mm plain aluminium sheeting alloy 31000 H4 in doors, ridges, hips, valley gutter,drip & straight flashing etc complete all as specified & directed.
Dismantling of floor hearth or wall tiling of any description including cement mortar complete all as specified and directed.
M&L for Non - skid Ceramic tiles (coloured ) 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick screed beding in CM 1:4 complete all as specified and directed.
Dismantling of Fibre/AC (corrugated or semi corrugated etc) sheet in roof covering etc complete all as specified and as directed.
S&F for 6mm thick asbestos cement corrugated or semi corrugated sheets in roofs, walls etc and fixed with L or J type hook or cranked hook bolt complete all as specified and as directed.
S&F for AC two pieces adjustable plain wing ridge 6mm thick fixed with J type bolts etc complete all as specified and as directed.
S&F MS work as in wind ties for roof including securing bolts, posts and struts in fencing/shed including cutting tops to shape as directed, drilling holes, notching for wire, flat iron fillets (for securing wire mesh) including all necessary drilling, bolting or rivetting etc and similar work conforming to Fe 410-O or Fe-310-O in repairs complete all as specified and as directed.
S&F PVC bends 110 mm dia laid to floor or mounted to wall for rain water pipe complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
Dismantling wall ceilling board (fiber pulp insulation etc) or insulation boards/ slabs /blankets any thickness including cover fillets complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any guage,thickness including Nanitial or similar pattern roof coverings complete all as specified and directed.
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. including 6mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to /GI frame work with screws complete all as specified and directed.
Sukaba Enterprises
Mohd Shakir and Co.
SahaDevSingh Constructions
JWALA ELECTRIC CONTRACTORS
m/s het singh sharma const co.
m/s shanti consruction co
kedar nath
milan enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .