Replacement of old and unserviceable 2.0 TR Split Type Air Conditioner in the Chamber of Deputy Secretary (Shipping), Room No. 1399, Secretariat, Sri Vijaya Puram
2026_APWD_24743_1
DB-8(1)/WO/WSD/2026-27/2780
Open Tender
Air-Conditioner
Works
2 days
Sri Vijaya Puram
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
18 Sept 2026
18 Sept 2026
21 Sept 2026
18 Sept 2026
21 Sept 2026
18 Sept 2026
18 Sept 2026 - 21 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only | |||||
| 1.1 | 2 TR capacity, 5 star rating | 1 | Each | 62,206.91 | ₹62,206.91 |
| 2SITC of wall mounting type of following capacity automatic line voltage stabilizer having range of 180V to 275V (minimum) single phase, 50Hz with steady single phase output voltage with built in time delay, high and low voltage cut-off with connecting 3 core cable of 1 meter length complete etc. as per site requirement. Make: V Guard or equivalent. | |||||
| 2.1 | 5 KVA single phase | 1 | Each | 4,651.05 | ₹4,651.05 |
| 3 | Providing & Fixing of pre-fabricated stand for keeping outdoor units of 1 Ton/1.5 Ton / 2 Ton Capacity split type AC as required. | 1 | Each | 1,141.3 | ₹1,141.3 |
| 4Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(Drain pipes for IDU of AC) | |||||
| 4.1 | 25 mm | 3 | Mtr | 130.48 | ₹391.44 |
| 5Providing and fixing of refrigerant copper pipes of following sizes (Suction & delivery) of split type AC i/c providing electrical cables, insulation, extra gas charging , cutting, drilling holes on the wall for passing gas pipes , fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish and covering with PVC non adhessive tape over the insulation of refrigerant pipes and as per the direction of E-in-C. | |||||
| 5.1 | Refrigerant pipes of Sizes 3/4" & 1/2" | 3 | Mtr | 2,072.52 | ₹6,217.56 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
BOQ_26187.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .