Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.1 LAccepted-Finance 14 147 VASUNDHRA GHAZIABAD SECTOR 14 VASUNDHRA VASUNDHRA GHAZIABAD UTTAR PRADESH 201012 | GHAZIABAD | UTTAR PRADESH | 201012 | L1 | Accepted-Finance L1 | |
| 2 | L2₹65.6 L+₹1.6 L (2.49%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹69.8 L+₹5.7 L (8.90%)Accepted-Finance A 04 ADGNJ CHANDAN NAGAR OPP IOCL PETROL PUMP RAMPUR ROAD BAREILLY U P 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L3 | Accepted-Finance L3 | |
| 4 | L4₹69.9 L+₹5.8 L (9.13%)Accepted-Finance | L4 | Accepted-Finance L4 | |
| 5 | L5₹70.3 L+₹6.3 L (9.78%)Accepted-Finance | L5 | Accepted-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹95,460
Closing Date
29 May 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer EUDC-III GHAZIABAD
SE EUDC-III GANDHI NAGAR GZB
Work of releasing connection in the area of EUDD-IV, Ghaziabad
2025_PVVNL_1035570_2
02/W/ 2025-26/E.U.D.C - 3 GZB
Open Tender
Electrical Works
Item Rate
90 days
SE EUDC-III GANDHI NAGAR GZB
Please Refer Tender Documents
2 documents required · 2 mandatory
₹3,540
Superintending Engineer EUDC-III GZB
₹95,460
31 May 2025
14 May 2025
29 May 2025
14 May 2025
29 May 2025
14 May 2025
Amount
For the work of releasing connection to 68 MLD, STP karhera (1380KW) & 71.17 MLD MPS Karhera (758KW) Ghaziabad in the area of EUDD-IV, Ghaziabad.
Carriage of ST POLE 11 METER SP-55 from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Transformer 33/11 KV 5 MVA from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Cable HT XLPE 33 KV 3x300 Sq.mm from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of ACSR Dog conductor from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV XLPE Cable 3x300 Sq. mm from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV XLPE Cable 3x120Sq. mm from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of other line steel material as:- M.S CHANNEL 100X50 X2240 MM - 490 Kg, DROPPER CHANNEL 125X50X2000 MM- 250 Kg, MS T-OFF CHANNEL- 175 Kg, MS ANGLE (65 X 65)- 145 Kg ...etc.. from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of M.S Earthing rod (2540x20 mm) from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Bus isolator 800A, 33KV from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Line isolator from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33KV Lightning arrester from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33 KV Post insulator from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV Electronic TVM from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of CT/PT unit O/D 60/5 A from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of CT/PT unit O/D 150/5 A from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33 KV CT O/D 200/100/1-1-1 A from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33 KV PT O/D 33KV/110V from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Cubical meter 60/5 A from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Cubical meter 150/5 A from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 90 lbs rail pieces for TF (44.64 Kg/Mtr.) from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33 KV VCB 1250 A from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 33 KV Control panel for single TF from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV VCB for I/C CTR 600/300/5A 350MVA from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV VCB for O/G CTR 200/100/5A, 350MVA from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Erection of ST pole 11 Mtr long at site complete in all respect as per RESPO norms.
Providing Concreating/Grouting of Pole complete in all respect as per RESPO norms.
Construction of new transformer plinth of size 4.5x3.5 Mtr. for Transfomer having depth 0.5 Mtr. below ground level & 0.5 Mtr. above ground level. The work including excavation of foundation. base & concreting of foundation base of CC 1:6:12 ratio (cement, fine sand & brick ballast) first class brick work of cement morter of ratio 1:4 for masonry & lintring work of transformer plinth of RCC work of ratio 1:2:4 (cement, coarse sand and store grit of 20mm using MS Bars of 10mm dia(tor) for reinforcement of linter including cutting, bending & binding of MS bars of required plinth size & shape. The work also includes laying of 7 Mtr. 90 lbs rail pieces for Transformer provide from store center (44.64 Kg/Mtr.) after cutting in proper size & shape & fitting etc. The plinth will be made as per RESSPO/Approved drawing suitable for 5 MVA transformer & shall be plastered of walls of ratio 1:4 (cement & fine sand)/finished on top and sides of the plinth.
Mounting & Safely placing of 5 MVA Transformer on the plinth by the help of Crane/Chain Cuppie etc. complete in all respect as per Respo Norms.
Providing and Water level earthing upto water level minimum at site complete in all respect as per RESPO norms.
Laying, Lifting and sagging/ Jumpering of ACSR Dog Conductor at various site complete in all respect as per RESPO norms.
Laying of 11KV KV XLPE cable 3x300 sqmm from power T/F to control room I/C . 11 KV Cable will be layed in brick trench constructed below 750x1050 mm to the ground level over the ganga sand. brick trench will be constructed by Ist class bricks covering three sides of cable, after laying 11 KV Cable brick trench will be filed by Ganga sand & then will be covered by bricks & backfill of soil over cable trench -150 Mtr and Laying of 11KV KV XLPE cable 3x300 sqmm in air/Trench- 10 Mtr complete in all respect as per RESPO norms.
Laying of Cable 33 KV 3x300 Sq.mm XLPE will be layed in brick trench constructed below 750x1050 mm to the ground level over the ganga sand. brick trench will be constructed by Ist class bricks covering three sides of cable, after laying 11 KV Cable brick trench will be filed by Ganga sand & then will be covered by bricks & backfill of soil over cable trench -100 Mtr and Laying of 33 KV 3x300 Sq.mm XLPE in air/Trench- 100 Mtr complete in all respect as per RESPO norms.
Providing of HDPE Pipe 6" Dia for 11 kv XLPE 3x120 sqmm Cable Laying complete in all respect as per respo norms.
Laying, of 11 kv XLPE 3x120 sqmm Cable with above HDPE Pipe through tranchless method complete in all respect as per respo norms.
Laying, of 11 kv XLPE 3x120 sqmm Cable underground with sand and brick method complete in all respect as per respo norms.
Laying, Lifting and sagging of 11 kv XLPE 3x120 sqmm Cable in air at site complete in all respect as per RESPO norms.
Providing Fixing and filing of 11 KV Cable J/kit outdoor type for 3x300 Sq.mm termination of cable by filling heat shrinkable type cable boxes including hoisting of cable and proper connection with bus bar gantry and bus isolator by providing suitable connectors complete in all respect as per respo norms. Jointing Kit used only approved vendor of PVVNL.
Providing Fixing and filing of 11 KV Cable J/kit indoor type for 3x300 Sq.mm termination of cable by filling heat shrinkable type cable boxes including hoisting of cable and proper connection with bus bar gantry and bus isolator by providing suitable connectors complete in all respect as per respo norms. Jointing Kit used only approved vendor of PVVNL.
Providing Fixing and filing of 11 KV Cable J/kit outdoor type for 3x120 Sq.mm termination of cable by filling heat shrinkable type cable boxes including hoisting of cable and proper connection with bus bar gantry and bus isolator by providing suitable connectors complete in all respect as per respo norms. Jointing Kit used only approved vendor of PVVNL.
Providing Fixing and filing of 11 KV Cable J/kit indoor type for 3x120 Sq.mm termination of cable by filling heat shrinkable type cable boxes including hoisting of cable and proper connection with bus bar gantry and bus isolator by providing suitable connectors complete in all respect as per respo norms. Jointing Kit used only approved vendor of PVVNL.
Providing Fixing and filing of 11 KV Cable Jointing Kit (3×120sq.Mm) Straight Through termination of cable by filling heat shrinkable type cable boxes including hoisting of cable and proper connection with bus bar gantry and bus isolator by providing suitable connectors complete in all respect as per respo norms. Jointing Kit used only approved vendor of PVVNL.
Providing Fixing and filing of Cable box O/D 33KV 3x300 Sq.mm XLPE termination of cable by filling heat shrinkable type cable boxes including hoisting of cable and proper connection with bus bar gantry and bus isolator by providing suitable connectors complete in all respect as per respo norms. Jointing Kit used only approved vendor of PVVNL.
Providing and construction of Plinth & Foundation of 33 kv VCB with safely placing complete in all respect as per respo norms.
Providing and Fabrication, erection and grouting of the Structure for bus & line isolator as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge
Providing and Fabrication, erection and grouting of the Structure for LA as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge
Providing and Fabrication, erection and grouting of the Structure for Fuse set as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge
Providing and Fabrication, erection and grouting of the Structure for post insulator as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge
Providing and Fabrication, erection and grouting of the Bus bar structure T- type as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge
Providing and Fabrication, erection and grouting of the Cable support structure on 100x50x6mm chanel as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge
Providing and Fabrication, erection and grouting of the Neutral link structure as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge
Providing and Fabrication, erection of the Structure for CT & PT as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge
Providing and Painting of the all above fabricated structures with one coat of red oxide primer and two coats of synthetic enamel alumm. Paint/green paint of ISI Mark alongwith earthing strip above ground level.
Fixing/Installation of 33 KV VCB 1250 A complete in all respect as per respo norms.
Fixing/Installation of 33 KV Control panel for single TF complete in all respect as per respo norms.
Fixing/Installation of 11 KV VCB for I/C CTR 600/300/5A 350MVA complete in all respect as per respo norms.
Fixing/Installation of 11 KV VCB for O/G CTR 200/100/5A, 350MVA complete in all respect as per respo norms.
Fixing/Installation of M.S Earthing rod (2540x20 mm) complete in all respect as per respo norms.
Fixing/Installation of Bus isolator 800A, 33KV complete in all respect as per respo norms.
Fixing/Installation of Line isolator complete in all respect as per respo norms.
Fixing/Installation of 33KV Lightning arrester complete in all respect as per respo norms.
Fixing/Installation of 33 KV Post insulator complete in all respect as per respo norms.
Fixing/Installation of 11 KV Electronic TVM complete in all respect as per respo norms.
Fixing/Installation of CT/PT unit O/D 60/5 A complete in all respect as per respo norms.
Fixing/Installation of CT/PT unit O/D 150/5 A complete in all respect as per respo norms.
Fixing/Installation of 33 KV CT O/D 200/100/1-1-1 A complete in all respect as per respo norms.
Fixing/Installation of 33 KV PT O/D 33KV/110V complete in all respect as per respo norms.
Fixing/Installation of Cubical meter 60/5 A complete in all respect as per respo norms.
Fixing/Installation of Cubical meter 150/5 A complete in all respect as per respo norms.
Fixing/Installation of M.S CHANNEL 100X50 X2240 MM complete in all respect as per respo norms.
Fixing/Installation of DROPPER CHANNEL 125X50X2000 MM complete in all respect as per respo norms.
Fixing/Installation of MS T-OFF CHANNEL complete in all respect as per respo norms.
Fixing/Installation of MS ANGLE (65 X 65) complete in all respect as per respo norms.
Providing & fixing of MS HOLDING CLAMP complete in all respect as per respo norms.
Providing & fixing of G.I. Pipe 150mm Dia complete in all respect as per respo norms.
Providing & fixing of DANGER BOARD WITH CLAMP complete in all respect as per respo norms.
Providing & fixing of G I PIPE "6" DIA complete in all respect as per respo norms.
Providing & fixing of Allu zinc coated NUT & BOLT OFF SIZE complete in all respect as per respo norms.
Providing & Painting of RED OXIDE PAINT complete in all respect as per respo norms.
Providing & fixing of PG Clamp Dog to Dog complete in all respect as per respo norms.
Providing Fixing/Installation of control cable 2x2.5 Sq.mm complete in all respect as per respo norms.
Providing Fixing/Installation of control cable 4x2.5 Sq.mm complete in all respect as per respo norms.
Testing & Commissioning charges of substation complete in all respect as per respo norms.
Providing & fixing of Copper bond 50x6mm for Neutral complete in all respect as per respo norms.
Providing & fixing of G.I. Strip of size 50x6mm complete in all respect as per respo norms.
Providing Fixing/Installation of Stone Pad complete in all respect as per respo norms.
Providing Fixing/Installation of of 33 KV Fuse set complete in all respect as per respo norms.
Providing Fixing/Installation of Copper bus bar of size 2500x50x6mm complete in all respect as per respo norms.
Making of all HT/LT connections required to energize the line and restoring of electricity supply to consumer properly complete in all respect.
For the work of releasing connection to 68 MLD, STP karhera (1380KW) & 71.17 MLD MPS Karhera (758KW) Ghaziabad in the area of EUDD-IV, Ghaziabad.
Carriage of ST Pole 11 M-IS 410 SP-55 from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV PILFER PROOF METERING CUBICAL CTR 60/5 from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV CT/PT O/D TYPE COMBINED METERING POLE MOUNTED UNIT 60/5 from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 10 MVA Transformer from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Cable AL.3 X 120 sq.mm XLPE 11 KV from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11KV VCB Outgoing from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Earth Rod from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of ACSR Dog Conductor from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV Polymeric Pin Insulator from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of MS Channel 100x50x2240 MM from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Dropper Channel from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of Tee Off Channel from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of MS Angle 65x65x6 MM from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV Electronic TVM from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Dismantling of 5 MVA Transformer and Safley carriage from work site to Store center/JE store loading and unloading both side.
Erection of ST Pole 11 M-IS 410 SP-55 at site complete in all respect as per RESPO norms.
Providing Concreating/Grouting of Pole complete in all respect as per RESPO norms.
Mounting & Safely placing of 10 MVA Transformer on existing plinth by the help of Crane/Chain Cuppie etc. alongwith its erection including fixing of all accessories complete in all respect as per Respo Norms.
Laying, Lifting and sagging/Jumpering of ACSR Dog Conductor at various site complete in all respect as per RESPO norms.
Providing of HDPE Pipe OD PN-80 Grade UV stablized for 11 kv XLPE 3x120 sqmm Cable Laying complete in all respect as per respo norms.
Laying, of 11 kv XLPE 3x120 sqmm Cable underground with sand and brick method-1150 Mtr with above HDPE Pipe OD PN-80 Grade UV stablized complete in all respect as per respo norms.
Laying, Lifting and sagging of 11 kv XLPE 3x120 sqmm Cable in air at site complete in all respect as per RESPO norms.
Fixing/Installation of 11KV VCB Outgoing complete in all respect as per respo norms.
Providing and Water level earthing upto water level minimum of 11KV VCB Outgoing at site complete in all respect as per RESPO norms.
Fixing/Installation of 11 KV PILFER PROOF METERING CUBICAL CTR 60/5 at site complete in all respect as per RESPO norms.
Fixing/Installation of 11 KV CT/PT O/D TYPE COMBINED METERING POLE MOUNTED UNIT 60/5 at site complete in all respect as per RESPO norms.
Fixing/Installation of Earth Rod at site complete in all respect as per RESPO norms.
Fixing/Installation of 11 KV Polymeric Pin Insulator at site complete in all respect as per RESPO norms.
Fixing/Installation of MS Channel 100x50x2240 MM at site complete in all respect as per RESPO norms.
Fixing/Installation of Dropper Channel at site complete in all respect as per RESPO norms.
Fixing/Installation of Tee Off Channel at site complete in all respect as per RESPO norms.
Fixing/Installation of MS Angle 65x65x6 MM at site complete in all respect as per RESPO norms.
Fixing/Installation of 11 KV Electronic TVM at site complete in all respect as per RESPO norms.
Providing Fixing/Installation of Holding Clamp complete in all respect as per respo norms.
Providing Fixing/Installation of Danger Board with Clamp complete in all respect as per respo norms.
Providing Fixing/Installation of G. I. Pipe 6'' Dia complete in all respect as per respo norms.
Providing Fixing/Installation of Allu zinc coated Nut & Bolt complete in all respect as per respo norms.
Providing & Painting of Red Oxide complete in all respect as per respo norms.
Providing Fixing and filing of 11 KV Cable Jointing Kit O/d (3×120 Sq. mm) termination of cable by filling heat shrinkable type cable boxes including hoisting of cable and proper connection with bus bar gantry and bus isolator by providing suitable connectors complete in all respect as per respo norms. Jointing Kit used only approved vendor of PVVNL.
Providing Fixing and filing of 11 KV Cable Jointing Kit (3×120 sq.mm) Straight Through termination of cable by filling heat shrinkable type cable boxes including hoisting of cable and proper connection with bus bar gantry and bus isolator by providing suitable connectors complete in all respect as per respo norms. Jointing Kit used only approved vendor of PVVNL.
Making of all HT/LT connections required to energize the line and restoring of electricity supply to consumer properly complete in all respect.
M/S PRAKHAR ELECTRIC WORK (BID ID -5222751)
BHARAT ELECTRICAL TRADERS (BID ID -5222148)
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER (BID ID -5213763)
NAVITECH ENGINEERS (BID ID -5222816)
M/s Shubham Traders (BID ID -5212437)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .