Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L1 | Accepted-AOC Awarded lowest | |
| 2 | L2₹22.9 L+₹6.4 L (38.9%)Rejected-Finance | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹23.8 L+₹7.3 L (44.6%)Rejected-Finance 1853 DARSHAN SINGH BUILDING MASTANA CHOWK RANJHI JABALPUR MP | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Highest amount quoted |
Tender Value
₹27.2 L
EMD Value
₹54,400
Closing Date
7 Mar 2024, 6:00 pmClosed
Garrisong Engineer (P) No 1 Jabalpur
Garrisong Engineer (P) No 1 Jabalpur 482005
REPAIR MAINTENANCE OF ELECTRICAL FITTING AND FIXTURE INCLUDING REPLACEMENT OF CONVENTIONAL LIGHT FITTINGS TO LED FITTINGS IN RESTRICTED DOMESTIC AREA OF SQAE (A) LPR AND AQAW(A) UNITS UNDER GE (P) NO 1 JABALPUR
2024_MES_639892_1
8457/KH/E8
Open Tender
Civil Works
Item Rate
180 days
GE (P) No 1 Jabalpur
D b (i)
7 documents required · 7 mandatory
₹500
GE (P) No 1 Jabalpur
₹54,400
19 Mar 2024
31 Jan 2024
9 Mar 2024
31 Jan 2024
7 Mar 2024
17 Feb 2024
31 Jan 2024 - 7 Feb 2024
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, holders, pendants, regulators, sockets etc and making good disturbed surface by using cement mortar, white cement, putty etc and match with existing surfaces of walls, floors etc complete all as specified as directed. (Note : (i) Taking down of light fittings any type will be measured separately
M&L for point wiring with two single core 1.5 Sq mm (Nominal cross section area), FRLS, PVC insulated, single core, unsheathed, multi stranded 1100 volts grade, copper conductor cable and one single core 1.5 Sqmm (Nominal cross section area), copper conductor as earth and earth dolly drawn through and including stove enamelled steel rigid concealed conduit of 20mm dia, including tee, bends elbows, junction box etc for one flame proof concealed conduit wiring light / fan point controlled by one flame proof switch including necessary cutting on wall / ceiling and making good disturbed surface complete all as specified and directed.
All as per item No. 2 above but 2.5sqmm (Nominal cross section area), complete all as specified and directed.
Supply and fixing LED light fitting 2 x 16 watt flame proof, CMRI certified recommended or gas / vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 die cast aluminium housing with heat resistant toughened glass with LED tube light fixures driver, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F switch flame proof rotary type with termination box in LM6, 16A, single pole 250 Volts complete all as specified and directed.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250 Volts, 2P+earth complete all as specified and directed.
S&F switch piano flush type suitable for 5Amp 230 Volt complete all as specified and directed.
S&F socket outlet 2 in 1.5 Pin 5 Amp flush type of polycarbonate body complete all as specified and directed.
S&F switch socket combination 5 in 1.5 Pin 5/6 Amp flush type universal of polycarbonate body complete all as specified and directed.
S&F switch socket combination 5 in 1.5 Pin 6/16 Amp flush type universal of polycarbonate body complete all as specified and directed.
S&F switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified and directed.
S&F call bell ding dong sound type suitable for AC 230 Volt single pole complete all as specified and directed.
S&F lamp holder / batten or angle holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified and directed.
S&F ceiling fan regulator electronic type 280 watt capacity of polycarbonate body ISI marked complete all as specified and directed.
S&F in replacement of flame plate for modular switch 1 module including screws and washer etc model/make as per existing in site complete all as specified and directed.
S&F in replacement of flame plate for modular switch 2 module including screws and washer etc model/make as per existing in site complete all as specified and directed.
S&F in replacement of flame plate for modular switch 3 module including screws and washer etc model/make as per existing in site complete all as specified and directed.
S&F in replacement of flame plate for modular switch 4 module including screws and washer etc model/make as per existing in site complete all as specified and directed.
S&F in replacement of flame plate for modular switch 6 module including screws and washer etc model/make as per existing in site complete all as specified and directed.
S&F in replacement of flame plate for modular switch 8 module including screws and washer etc model/make as per existing in site complete all as specified and directed.
S&F in replacement MS Housing box 1/2 module suitable for for modular switch as per existing switch box and making good to the disturb surface complete all as specified and directed.
S&F in replacement MS Housing box 3 module suitable for for modular switch as per existing switch box and making good to the disturb surface complete all as specified and directed.
S&F in replacement MS Housing box 4/5 module suitable for for modular switch as per existing switch box and making good to the disturb surface complete all as specified and directed.
S&F in replacement MS Housing box 6/8 module suitable for for modular switch as per existing switch box and making good to the disturb surface complete all as specified and directed.
S&F in replacement of modular switch 6-10 Amp one module 230 volts AC as per existing model/make complete all as specified and directed.
S&F in replacement of modular switch 16 Amp one module 230 volts AC as per existing model/make complete all as specified and directed.
S&F in replacement of modular socket, 6A-2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and directed.
S&F in replacement of modular socket, 6/16A-2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and directed.
S&F in replacement modular fan regulator, 2 Module 4 step 180w heavy duty 230 volts as per existing model/make complete all as specified and directed.
S&F in replacement modular bell push switch piano, flush type 6 Amps complete all as specified and directed.
S&F in replacement of single core wire 6sqmm multistrand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
S&F in replacement of single core wire 4 sqmm multistrand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
S&F in replacement of single core wire 2.5 sqmm multistrand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
S&F in replacement of single core wire 1.5 sqmm multistrand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
S&F in replacement of PVC insulated, unsheathed twin twisted copper conductor wire of nominal size 23/0.0076, 1100 volt grade, ISI marked, complete all as specified and directed.
M&L PVC insulation tape of width 18mm, thicknes 0.125 mm in length of 6 mtr, ISI marked complete all as specified and directed.
S&F in replacement MCB triple pole and neutral 63 Amps, 415V, 10KA breaking capacity complete all as specified and directed.
S&F MCB, SPN, 240 volts, 40 Amps capacity 'C' series complete all as specified and directed.
S&F MCB, SP, 240 volts, 5 to 32 Amps capacity 'C' series complete all as specified and directed.
S&F in repairs Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps all as specified and directed.
Supply and fix LED tube light fitting box type 20 watts, 2000-2200 luminaire with poly carbonate LED upto 2100 lumin tube rod with in built reflector of same make, connecting cable three core PVC insulated and PVC sheathed copper flexible cable of size 16/0. 20mm with two Nos. MS bracket on wall including hanging arrangment and necessary fixing arrangement complete all as directed.
Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watts, 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable fo suitable size complete.
Supply and fix LED light fitting 1x9W/1x10W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed/surface type, as directed, with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED 15/18 recessed/surface mounted downlighter spotlight fitting, 110 lumin per watts, decorative type with all accessories and proper connection from fitting to existing point as per site requirement and making the surface smooth complete all as directed.
S&F in replacement of LED security light Luminaire 35 Watt with 4500 or more lumen warm white, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 Volts, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type, GI pipe 40 mm dia medium Grade not less than with 1.2 m long in any shape with 2 Nos of pole fitting clamps made out of MS flat, nuts and bolts and painting with aluminium paint complete all as specified and directed.
S&F in repair LED bulb 230V AC 9/10 watt cool day light 6500K heavy duty complete all as specified and directed.
S&F in repair LED bulb 230V AC 7 watt cool day light 6500K heavy duty thread type or as required at site complete all as specified and directed.
Supply fixing and connecting LED top post lantren, decorative luminaire with diffuser, 240 volts, 50 Hz, 20 watts with mounting arrangement incl taking down of existing fitting complete all as specified and directed.
Comprehensive maint of window type/split type air conditioner of capacity 1.5 / 2 Ton including taking out, reinstalling after repairing, cleaning, servicing, oiling in moveable parts and charging of refrigrent gas if required including testing, comissioning and quarterly servicing of each Air Conditioner and in between period as an when required machanic will visit for minor repair such as electric connections, replacement of small size of wire, cleaning of filter and complete till completion of work all as specified and as directed. Note : (i) Cost of refrigrent gas and necessary spare parts shall be paid separately. (ii) No extra payment will be made to the contractor for machanic visit.
Servicing, maintenance and repairs to regrigerator / deep freezer of capacity up to 310 Ltrs of any make and model including periodical cleanng to condenser coil and compreser. Replacement of defectice spares will be measured and paid separately under relevant items as under complete all as specified and directed.
Comprehensive maint of water cooler of any make, any type and any capacity after disconnecting inlet, outlet drain pipe and reinstalling, connecting the same after repairing including taking out, reinstalling after repairing, servicing, cleaning of water tank and charging of refrigrent gas if required including testing, comissioning and quarterly servicing of each Water Cooler and in between period as an when required machanic will visit for minor repair such as electric connections, replacement of small size of wire, cleaning of inner tank and complete till completion of work all as specified and as directed. Note : (i) Cost of refrigrent gas and necessary spare parts shall be paid separately. (ii) No extra payment will be made to the contractor for machanic visit.
S&F in repair sealed unit compressor suitable for split type air conditioner of 1.5 Ton capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as specified and directed. Note : Cost of refrigrent gas shall be paid under relavent item.
S&F in repair sealed unit compressor suitable for split type air conditioner of 2 Ton capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as specified and directed. Note : Cost of refrigrent gas shall be paid under relavent item.
S&F in repair sealed unit compressor suitable for water cooler of 40/80 litres capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as specified and directed. Note : Gas for charging shall be measured and paid under relavent item.
S&F in repair sealed unit compressor suitable for water cooler of 60/120 litres capacity, cutting of suction and discharge copper tubes including breezing, jointing, testing and commissioning complete all as specified and directed. Note : Gas for charging shall be measured and paid under relavent item.
S&F in repair PCB (Printed Control Board) with remote control operation and sensor for window type AC/split type AC/multi split type AC 1.5 / 2.0 TR complete all as specified and directed.
S&F in replacement of unserviceable starting capacitor of 80-100 60-80 MFD capacity 220-240 Volt including taking down old (starting capacitor for water cooler) complete all as specified and directed.
S&F in replacement of unserviceable running capacitor 220-240 Volt , 50 HZ of 45-55 MFD capacity including taking down old running capacitor ( suitable for Air conditioner / water cooler) complete all as specified and directed.
S&F in replacement of unserviceable contactor switch suitable for 1.5/2 TON capacity AC, any type and any make complete all as specified and directed.
S&F in replacement of unserviceable over load protector,relay,capacitor for water cooler of any capacity, any type and any make complete all as specified and directed.
S&F in replacement of unserviceable Filter pad for 1.5/2 Ton air conditoner any type and any make complete all as specified and directed.
S&F in replacement of water cooler copper condensor coil complete with all accessories ,all as per site requirement for any capacity / any type water cooler complete all as specified and directed.
S&F in replacement of Split AC uutdoor unit copper condensor coil complete with all accessories, all as per site requirement for 1.5/2 Ton capacity AC complete all as specified and directed.
S&F in replacement of rusted outdoor mounting stand set with new one for outdoor unit of Split type AC including nuts, bolts & wahers complete all as specified and directed.
S&F Drain hose pipe for 1.5/2 Ton AC complete all as specified and directed.
S&F Swing motor suitable for 1.5/2 Ton AC complete all as specified and directed.
S&F coil Sensor and air sensor suitable for 1.5/2 Ton AC complete all as specified and directed.
S&F in replacement of unserviceable thermostate suitable for water cooler complete all as specified and directed.
S&F in replacement of unserviceable dry filter suitable for Any capacity window/split type air conditioner complete all as specified and directed.
S&F in replacement of unserviceable propeller fan blade suitable for window/split type air conditioner outdoor unit complete all as specified and directed.
S&F in replacement of unserviceable propeller fan blade suitable for water cooler compressor unit of any type and any capacity complete all as specified and directed.
S&F in replacement of unserviceable Chromium plated cock of 15 mm dia for water cooler Push type complete all as specified and directed.
S&F in replacement of unserviceable Chromium plated cock of 15 mm dia for water cooler self close type complete all as specified and directed.
Supply and charging of gas F-22/R-32/R-134/R-290/R-600A/R-410A (freon) suitable for water cooler/window or split AC of any type complete all as specified and directed.
S&F in replacement of unserviceable copper tube ( suction /discharge line copper tube ) for Window/split A/C of any make / type complete all as specified and directed.
S&F in replacement of Float valve for Water cooler of existing size any make and any type complete all as specified and directed.
S&F in replacement of unserviceable condensor motor in Air Conditioner of capacity 0.087 HP (65 Watt ) / 0.08 HP (60 Watt ) / 0.120 HP (90 Watt), 240 Volt, 50HZ (suitable for Air conditioner) & testing complete all as specified and directed.
S&F in replacement of unserviceable blower motor in Air Conditioner of capacity 0.038 HP (29 Watt ) / 0.024 HP (18 Watt ) / 0.048 HP (36 Watt ), 240 Volt, 50HZ (suitable for Air conditioner) & testing complete all as specified and directed.
S&F in replacement of unserviceable condensor motor in water cooler of capacity 0.087 HP (65 Watt ) / 0.120 HP (90 Watt), 240 Volt, 50HZ (suitable for water cooler) & testing complete all as specified and directed.
Taking down and disconnecting existing voltage stabilizer upto 5 KVA and strip opening up, single phase automatic buck and boost type with input voltage not less then 130 Volts to 280 Volts and output voltage 230 Volts, plus or minus 2.5% replacement of unserviceable parts re-assembling complete all as specified and directed. Note : Rewinding of voltage stabilizer if required will be measured and paid separately.
Re-winding power transformer of stabilizer of capacity 1 KVA to 5 KVA with super enamelled copper winding of same gauge and turns as per existing including all insulating material such as latherite paper, glass sleeves, paper insulation if required, varnishing, drying and testing complete all as specified and directed.
Comprehensive maint of desert cooler of any make/type Cleaning / overhauling, greasing of fan motor ,fan and checking electric connection and reconnecting the electric connection complete all as directed. Note : Items required to be replaced, over hauling & rewinding of fan motor if required will be measured and paid separately.
Dismantling fan motor of desert cooler and removing the burnt winding and Material and labour for rewinding the same with supper enamelled copper wire of existing size, gauge and turns including cleaning the slots properly, and testing complete all as specified and directed.
S&F in replacement of unserviceable fan blade suitable for desert cooler any type and any capacity complete all as specified and directed.
S&F in replacement of unserviceable khas pads/wood wool pad of required size for desert cooler of any make complete all as specified and directed.
S&F in repair of fan motor with blade suitable for desert cooler of any type /capacity single phase, 230 Volt complete all as specified and directed.
S&F in replacement of unserviceable submersible water lifting pump for desert cooler, 240 Volts, 50 Hz, AC, 12 Watt, 1.5 Metres max head and output : 800 LPH complete all as specified and directed.
M&L repair/maintenance and servicing of RO filter of capacity upto 20 litres per hour, 230V AC supply icluding replacement of micron pre filter, activated arbon filters, sediment filters, cleaning the housing, servicing UV filters, Complete all as directed. Note :- RO membrane if required to be replaced shall be measured separately.
S&F in repair membrane o suitable size as per site requirement for water cooler RO plant of capacity upto 20 Ltrs/hr complete all as directed.
S&F in repair housing of suitable size as per site requirement for water cooler RO plant complete all as directed.
S&F in repair solenoid valve (SV) of suitable size as per site requirement for water cooler RO plant complete all as directed.
S&F in repair FRT of suitable size as per site requirement for water cooler RO plant complete all as directed.
S&F in repair PVC pipe of suitable size as per site requirement for water cooler RO plant complete all as directed.
S&F in repair RO booster pump of suitable capacity as per site requirement for water cooler RO plant complete all as directed. Note :- for item No 90 to 97 cost of service charge for monthly visit of mechanic is included in the coated rate.
S&F in repair RO plant water cooler sensor complete all as per site requirement all as directed.
Taking down carefully ceiling fan/exhaust fan/wall fan any size / make with cable and all accessories remove from site to store for repair/overhaulling complete all as directed.
Preventive maintenance and checking of ceiling /exhaust/wall fan/air circulator/table fan/padestal fan of any size/type/make, checking the serviceability of safety pins, clamps, down ros, rubber bushes, nuts, bolts, canopies and electric connections etc. reconnecting /hanging in original position, reconnecting the electric cables and testing complete all as directed (Note :- Items required to be replaced, overhaulling & rewinding of fan motor if required will be measured and paid separately including)
Dismantle the ceiling /exhaust/wall fan/air circulator/table fan/padestal fan of any size/sweep, cleaning servicing, greasing the fan motor and reassemble the fan complete all as directed (Note :- Items required to be replaced, overhaulling & rewinding of fan motor if required will be measured and paid separately including)
Dismantling of ceiling fan 1200/1400 mm sweep and removing the burnt winding and material and labour for rewinding the same with supper enamelled copper wire of existing size, gauge and turns including the slots properly and testing complete all as directed.
Dismantling of exhaust fan/wall mounting fan/padestrial fan of any sweep and removing the burnt winding and material and labour for rewinding the same with supper enamelled copper wire of existing size, gauge and turns including the slots properly and testing complete all as directed.
S&F in replacement of unsv fan blade suitable for ceiling fan of any type /size complete all as directed.
S&F in repairs down rod suitable for ceiling fan complete all as directed.
S&F in replacement of unsv condensor ISI marked 2.5 mfd complete all as directed.
S&F in replacement of unsv ball bearing/bush suitable for ceiling fan/exhaust fan/wall fan/air circulator/padestal fan any size complete all as directed.
Maint and repair of solar water heating system (plant) of capacity 200 ltrs, cleaning servicing of complete system with panel and solar water tube including cleaning of air blockage and minor repair with replacement of parts as and when required at site complete all as directed.
Supply only solar water tubes of plants cap 200 ltrs complete all as directed.
Supply only panel washer for top and bottom of tubes for solar water tubes of plants cap 200 ltrs complete all as directed.
Taking down carefully storage type water heaters (Geyser) of any type and make of capacity upto 50 ltrs, after disconnecting their electrical and water connections. De-scaling the inner container, heating element, base assembly using diluted hydrochloric acid and cleaning thoroughly. Filling the inner container with water and detecting leakage including brazing as required to stop the leakage, if any, reassembling the geysers after replacing the u/s spare parts, filling water and testing the geysers by applying pressure by means of hand/foot operated pump, to ensure leak proof. Refixing geyser in the same original position/location and making the electrical/water supply connections incl testing on completion complete all as specified and directed. Note - Items required to be replaced shall be measured and paid separately under relevent items of the Schedule.
S&F Thermostat suitable for Geyser 25/35/50 ltr complete all as specified and directed.
S&F Geyser Element 1000/1500 Watt of any type complete all as specified and directed.
S&F Geyser connection pipe 12/18'' long with sockets in both end, made of steel complete all as specified and directed.
S&F in repairs High Bay luminaire for use with LED lamps, of capacity not less than 100 Watts, 230 Volts, with high quality lenses & reflector, High grade aluminium pressure Die-Cast Housing with toughened glass cover, complete with control gear and all accessories including fixing accessories as required complete all as specified and directed.
Schedule of credit amount of Rs. 45459.00 to be deducted during AOC
RELIABLE PRODUCTS AND SERVICES
M/S. HONEY CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .