Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.7 L+₹10,254.81 (0.50%)Rejected-AOC VILLAGE DINAK P O KANAID TEHSIL SUNDERNAGAR | BILASPUR | HIMACHAL PRADESH | 174001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹26.1 L+₹5.5 L (26.8%)Rejected-AOC GROUND FLOOR THAKUR COMPLEX BASANTPUR | BASANTPUR | SHIMLA | HIMACHAL PRADESH | 171018 | L3 | Rejected-AOC L3 | |
| 4 | L4₹31.1 L+₹10.5 L (51.3%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹37.4 L+₹16.8 L (81.8%)Rejected-AOC HOUSE NO 45 NEAR MONAL PUBLIC SCHOOL SANJAULI SHIMLA 171006 | SHIMLA | HIMACHAL PRADESH | 171006 | L5 | Rejected-AOC L5 |
Tender Value
₹23.2 L
EMD Value
₹42,400
Closing Date
11 Jun 2016, 5:00 pmClosed
EE Electrical
Electrical division No-I Shimla-9
Providing E.I. there in
2016_PWD_11900_1
No.PW.ED.AB.Tender 2016..404-10 dated03.05.16
Open Tender
Electrical Works
Item Rate
360 days
Solan Arki
Please refer tender document
7 documents required · 7 mandatory
₹500
EE Electrical
₹42,400
25 Jul 2023
18 May 2016
13 Jun 2016
18 May 2016
11 Jun 2016
18 May 2016
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Group C
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x1.5 Sq. mm.
2x6 Sq.mm.
2x10 Sq.mm.
Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and fixing metal box of 100mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 200mmx150mmx75mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 3 pair of S.P. 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required.(Computer Point)
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double Door-8 Way.
Double Door-12 Way.
Double Door-16 Way.
Double Door-4 Way.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(MCB-6AMP=82Nos+16Amps=56Nos =138 Nos
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- 40 Amps=7 Nos+63 Amps=18Nos=25Nos
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Triple pole & Neutral. Cat-A.
Supplying and fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 Amps, 415 volts, TPN industrial socket outlet, 4-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp TPN-MCB, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
Providing and fixing TP&N switch disconnector fuse unit cubical type, 415/500 volts with 3 No. HBC/HRC fuses, in sheet steel enclosure including drilling holes on the board, connections, earthing the body etc. as required.
63 Amp. Category-A
100 Amp. Category-A
200 Amp. Category-A
Supplying and fixing sheet metal bus-bar chamber suitable for 63 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 450mm & cross-sectional area (16mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (530mmx350mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 600mm & cross-sectional area (25.4mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (680mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and fixing sheet metal bus-bar chamber suitable for 200 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 600mm & cross-sectional area (25.4mmx4.75mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (680mmx450mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps
Providing and fixing ultra slim decorative extruded box fixture with Commercial electronic ballast, snap-on installers, suitable for 28 watt FTL (T5), complete with all accessories (including one No. T-5 Tube), connections, testing and commissioning etc. as required.1x28 watt-FTL(T5) (Cat.-A)
Providing and fixing following surface mounting T5 luminaries with powder coated CRCA sheet steel housing, mirror optics reflector, electronic ballast, decorative end caps, suitable for 28 watt FTL (T5), complete with all accessories (excluding the T-5 Tube), connections, testing and commissioning etc. as required. 2 x28 watt-FTL(T5) (Category-A)
Providing and fixing following type of surface mounting decorative mirror optics luminaire with powder coated CRCA sheet steel housing, low glare aluminium mirror reflector, pre-wired with 110 V starter & 36/40 w copper ballast for housing CFL (but excluding the cost of CFL), complete with all accessories, connections, testing and commissioning etc. as required.
2 x18watt-CFL (Category-A)
3 x36 watt-CFL (Category-A)
Supplying and fixing of surface/recess mounting ceiling fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Ceiling fitting, surface type (Category-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- (A) Ceiling Fan 1200 mm sweep, Category-A
(B) Ceiling Fan 1400 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Exhaust Fan, Heavy duty, 300 mm sweep
Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Bulk head fitting, CFL type (Category-A)
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Mirror light 460 mm, single lamp.(Category-A)
Providing & fixing of White foot light with 8 model box and lamp holder of Havell make as per cat no CQ000462 but with out CFL lamp complete in all respect.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 16 sq. mm (four core)
Armoured cable 25 sq. mm (3.5 core)
Armoured cable 400 sq. mm (3.5 core)
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
Providing and fixing 25mm x 5mm copper strip in 40 mm dia. G.I. pipe from earth electrode etc. as required.
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron 50 mm x 50 mm x 6 mm thick duly welded complete with 3mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required:-
P/F of 65 mm bore dia G.I. pipe A Class for Service connections of the building with best satisfaction of Engineer in Charge.
Providing and erection of CFL ( Compact florurcent lamp ) existing fittings 11/15 watt.
Providing and erection of CFL ( Compact florurcent lamp ) existing fittings 18 watt.Pin type.
Providing and erection of CFL ( Compact florurcent lamp ) existing fittings 36 watt.Pin type.
Providing Erection of T-5 tube rod existing fittings 28 watt.
Note:-The Steel conduit pipe of different sizes already laid at site, necessary recovery will be made from the bill of the Contractor on the following rates.i) Steel conduit size 20mm dia= Rs. 111/- Per Meter. ii) Steel conduit size 25mm dia= Rs. 129/- Per Meter.
Bhardwaj Electrical Co.
Rakesh Kumar
Haminder Pal
vijan agencies
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_15345.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .