| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.2 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹37.2 L+₹47,431.30 (1.29%)Rejected-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹44.7 L+₹7.9 L (21.6%)Rejected-AOC | L-3 | Rejected-AOC L-3 | |
| 4 | Rejected-Technical 6 341 RATAN VIHAR NANGLOI DELHI 110041 | DELHI | WEST DELHI | DELHI | 110041 | - | Rejected-Technical Not enlisted in eligible category |
Tender Value
Refer Docs
EMD Value
₹96,800
Closing Date
9 May 2022, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION, LT/HT CABLES, PANELS, STREET LIGHT AND CERTAIN ALLIED WORKS IN SSPL LAB UNDER GE (I) RND DELHI
2022_MES_514650_1
GE/RND-115/DLI/2021-2022
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class- D, Cat b(i), (ii)
2 documents required · 2 mandatory
₹500
Yes
GE I RND DELHI
₹96,800
Yes
10 Jun 2022
21 Mar 2022
11 May 2022
21 Mar 2022
9 May 2022
26 Apr 2022
Amount
S&F in repair end termination joint 11 KV indoor type, end termination heat shrinkable of size 3x 95 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and directed.
S&F in repair cable jointing kit for 11KV (Earthed) grade cable for indoor termination , heat shrinkable of size 120 to 185 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and directed.
S&F in repairs straight through joint 11 KV heat shrinkable of size upto 95 Sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and directed.
S&F in repairs straight through joint 11 KV heat shrinkable of size 120 to 185 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and directed.
S&F in replacement of ACB 4 pole ,415 V with thermal magnetic release (Manual fixed type) of capacity 630 Amps complete all as specified & directed.
All as per item srl No 5.00 above but capacity 800 Amps
All as per item srl No 5.00 above but capacity 1000 Amps.
All as per item srl No 5.00 above but capacity 1250Amps.
All as per item srl No 5.00 above but capacity 1600 Amps.
Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 core including suitable size aluminium lugs properly crimpled with crimping tools including testing complete all as specified and directed
All as per item Srl No 10 above but 35 Sqmm 3.5 core.
All as per item srl No 10.00 above but 50 Sqmm 3.5 core
All as per item srl No 10.00 above but 70 Sqmm 3.5 core
All as per item srl No 10.00 above but 95 Sqmm 3.5 core
All as per item srl No 10.00 above but 120 Sqmm 3.5 core
All as per item srl No 10.00 above but 185 Sqmm 3.5 core
All as per item srl No 10.00 above but 240 Sqmm 3.5 core
Supply and laying in replacement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 Sqmm 3 core including testing complete all as specified & directed
All as per item srl No 18.00 above but 95 Sqmm 3 core
Supply and laying in replacement GI pipe light grade of 100mm dia laid in trenches for protection of UG cable complete all as specified and directed.
All as per item srl No 20.00 above but 80mm dia
M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique /manually/ mechanically and necessary machine including supply and laying of 100mm dia HDPE/GI pipe complete all as specified and directed
Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB/OCB HT 11KV 300 to 630 Amps of any make and type and servicing of all minor/major parts of the VCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley component as directed , inserting the trolley, testing the complete HT electric supply and putting on supply on load complete all as specified & directed. Note:- All cleaning /testing equipment/ safety equipment material shall be provided by the contractor and cost for the same shall be demed to be included in quoted rates.
Calibration of relay of 11KV HT VCBs and 1.1KV ACBs installed at various sub stn at KWC area complete all as specified and directed. Note:- 1. All testing & calibration equipment with all accessories shall be brought by the contractor and cost for same is deemed to be included in quated rates. 2. The complete test report shall be submitted by the contractor to Engr-in-charge/GE(I)R&D Delhi
S&F in replacement HRC /MCB fuse link clip type on fuse link 2 to 20 amp operating voltage 415 V complete all as specified and directed.
S&F in replacement fuse base suitable for cylindrical /DIN type HRC fuse of capacity 2-32 amps complete all as specified and directed.
S&F in replacement closing spring assembly complete all as specified and directed.
S&F in replacement tripping spring assembly complete all as specified and directed.
S&F in replacement charging motor cut off limit switch complete all as specified and directed.
S&F in replacement spring charging handle motorized mechanism of VCB complete all as specified and directed.
S&F in replacement push button bracket assembly complete all as specified and directed.
S&F in replacement bus bar support insulator 75 mm dia including all fixing accessories suitable for VCB/HT Bus bar chamber complete all as specified and directed.
S&F in replacement bus bar barrier as per existing (set of three) with nuts bolts complete all as specified and directed.
S&F in replacement toggle switch for space heater complete with all accessories complete all as specified and directed.
S&F in replacement Charged/Discharged indication assembly complete all as specified and directed.
M&L in replacement control wiring for panel with 2.5 Sqmm copper conductor FRLSH cable including proper laying with the help of locking device as per manufacturer instruction complete all as specified and directed
M&L for taking down repairable potential transformer of HT VCB 11 KV/ 110 V of any make, opening & dismantling the complete unit and refixing after carrying out the following repairs/replacement :- (a) Rewinding of transformer as per existing gauge and pattern. (b) Cleaning and servicing of the PT. (c) Replacement of wornout nuts/bolts and other minor parts including HRC Fuse. (d) Soldering / tightening of loose connections. (e) Replacement of potential transformer oil having dielectric strength upto 50 KV. (f) Painting of outer portion of PT with synthetic enamel paint of grey colour. (g) Testing of the PT's for proper functioning to the entire satisfaction of the Engineer- in-charge
S&F in replacement potential transformer of HT VCB 11 KV/110 V complete all as specified and as directed
S&F in replacement 11 pin anti pumping relay 110V DC complete all as specified and directed.
S&F in replacement bottom terminal with jaw contact complete all as specified and directed.
S&F in replacement top terminal with jaw contact complete all as specified and directed.
S&F in replacement space heater 230V AC 80W with accessories complete all as specified and directed.
S&F in replacement thermostat with accessories complete all as specified and directed.
S&F in replacement PT epoxy female bushing suitable for R-Y-B phase complete all as specified and directed.
S&F in replacement PT epoxy male bushing suitable for R-Y-B phase complete all as specified and directed.
S&F in replacement PT fuse 11 KV complete all as specified and directed.
Dehydration and filtration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 60 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and directed.
Supply and topping up transformer oil having dielectric strength not less than 45 KV complete all as specified and directed.
Taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 200 to 450 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required complete to the entire satisfaction of Engineer- in-charge.
All as per item ser No 49.00 above but of capacity 500 to 1000 KVA
S&F in repair HT bushing 11KV suitable for 200 to 1000 KVA /1500KVA Transformer including brass rod with gasket as per existing conditions complete all as specified and directed.
S&F in repair LT bushing 11KV suitable for 200 KVA to 1000 /1500 KVA transformer including brass rod with gasket as per to existing conditions complete all as specified and directed.
S&F in repair head gasket sheet 6mm thick suitable for Transformer 200KVA to 450 KVA capacity including replacement of nuts, bolts, washers and necessary T&P required at site complete all as specified and directed.
S&F in repair head gasket sheet 6mm thick suitable for Transformer 500KVA to 1000 KVA capacity including replacement of nuts, bolts, washers and necessary T&P required at site complete all as specified and directed.
S&F in repair Dehydrating breather assembly with silica gel grains in the breather assembly suitable for transformers 200 KVA to 1000KVA as per existing conditions complete all as specified and directed
S&F in repair temperature gauge analog type with all accessories as per existing conditions complete all as specified and directed
S&F in repair voltmeter digital type for voltage range of (0-500V) including all accessories and wiring complete all as specified and directed.
S&F in repair ammeter digital type for current range of 0-1000 Amps as per existing conditions including all accessories and wiring complete all as specified and directed.
S&F in repair power factor meter digital type for frequency range (45-65 Hz) as per existing conditions including all accessories and wiring complete all as specified and directed.
S&F in repair three phase over current earth fault relay MC-61 as per existing conditions including all accessories and wiring complete all as specified and directed.
S&F in repair three phase overcurrent earth fault relay MC-61A as per existing conditions including all accessories and wiring complete all as specified and directed.
S&F in repair three phase digital KV volt meter range up to 15 KV as per existing conditions including all accessories and wiring complete all as specified and directed.
S&F in repair LED type Indicating lamp of voltage AC/DC set of RYB, as per existing conditions complete all as specified and directed.
S&F in repair Battery Charger of capacity 12 volt for AMF panel complete all as specified and directed.
S&F in repair Battery Charger of capacity 24 volt for AMF panel complete all as specified and directed.
S&F in repair Current Transformer as per exisitng conditions complete all as specified and directed.
S&F in repair Multifunctional meter complete all as specified and directed
S&F in repair VCB Power Pack unit 24 Volt DC 7 AH with battery bank for backup including panel as per exisitng conditions complete all as specified and directed
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width for LT Cables, HT Cables, complete all as specifed and directed
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply & laying dry fine clean sand for cushioning of underground cable laid in trenches/duct complete all as specified and directed. Note : Punned thickness shall be measured.
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and laying un-reinforced factory made precast concrete cable cover , class HV, type 1, flat size-300x180x40 mm complete all as specified and directed
Excavation in trenches in hard/dense soil not exceeding 1.5m depth & not exceeding 1.5m in width for LT Cables complete all as specified & directed
S&F in replacement 3 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified & directed
S&F in replacement 3 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified & directed
S&F in replacement 3 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified & directed.
S&F in replacement 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified & directed.
S&F in replacement 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified & directed.
S&F in replacement 4 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified & directed.
S&F in repair Steel tubular swaged poles ( swan neck type) with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31,9 metres long poles duly painted with two coats of black bituminus paint through out internally and externally upto plinth height. The remaning portion of the pole shall be painted with one coat of red oxide primer complete all as specified & directed. Note : Rate for demolition of PCC including taking out unserviceable poles are deemed to be included in quoted rates. Earth work & PCC shall be measured & paid separately under respective item of BOQ
M&L for PCC 1:3:6 type B1 using 20 mm graded stone aggregate for foundation of pole complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation of pole complete all as specified and directed.
S&F in repair junction box SMC kiosk box water proof IP-54 of size 140x140x95 mm incl fixing of terminal connector 100 A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified & directed.
S&F in repair Capacitor Bank MPP-H, 5 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 10 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 20 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 25 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
Supply and laying GI pipe light grade size 40 mm dia fixed on wall/laying in trench including all connected fitting/acessories including taking out old unserviceable complete all as specified and directed
Supply and laying in replacement of old unserviceable XLPE insulated heavy duty electric cables with aluminium conductor,1100 volts grade, cross sectional area 16 Sqmm 4 Core and testing complete all as specified and directed
S&F in replacement of old unserviceable bollard light cone series act as an imposing street furniture a silient observed, diffuser at the upper portion adds functional value with IP-65 with in built 8 watt LED 1 M height and connected all acessories complete all as specified and directed
Supply and fixing in repair PVC pipe of size 20 mm dia medium grade iicluding all connected acessories complete all as specified and directed
Supply and fixing Cross arms of angle iron bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape ( as per site requirment or directed by Engr -in-charge) size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint, two end of angle iron grouting in the wall upto 8 inch including clamp bend to shape with nut & bolt and finishing the wall with cement mortar complete all as specified and directed
Dismantling old rusted cross-arms of M.S. channel or angle sections etc. and setting aside with in 50 mtr complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron wire 4mm dia by means of Copper nuts, bolts and washers. GI wire laid in 20mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI wire 4 mm dia (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for repair, rewinding indoor transformer of 500 KVA capacity, the item of works to be carried out are as under :- (i) Disconnection of Transformer for both HT/LT Panel. (ii) Shift the transformer to the workshop. (iii) Drain out the Transformer Oil and clean the Chamber. (iv) Open the Transformer and Rewind the Both side with the existing gauge winding wire. (v) Fixing only HT procelain bushing with studs, nuts, washers 3 Nos. and LT procelain bushing with studs, nuts and washers 4 Nos. and connection with primary and secondary windings and reconnecting with the main terminals as required and directed. (vi) Fixing only breather assembly, conservator, oil temperature gauge after proper cleaning, minor repairs etc. as required and directed. (vii) Replacement of all unserviceable gasket with new from top cover, HT/LT bushing with new one by using rubberised gasket sheet 4.0mm/6.0mm thick duly pasted with suitable adhesive. (viii) Replacement of unserviceable bolts with new one and fixing existing serviceable bolts, nuts, washers of different sizes and tightening properly. (ix) Repositioning of core and winding assembly inside the tank, assembling complete unit and making the traansformer ready for filling oil and subsequent testing as directed. (x) Filling of Fresh Transformer Oil and Test the rewinded Transformer as Per IS Norms-2026. (xi) Brought the Transformer from workshop to site after full satisfaction of Engr-in-Charge. (xii) Fix at old location and connect from both side as directed by Engineer-in-Charge.
BLANK
Taking down of Old unserviceable point wiring any type for light, fan, power etc including unserviceable switch,socket, regulator and ceiling rose etc of any make complete including making good disturbed surfaces of walls ,floors roof etc complette all as specified & directed.
Taking down Celling Fan carefully and refixing the same including Painting with synthetic enamel white paint by spraying ,greasing,minor repair if required complete all as specified & directed.
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable FRLSH PVC insulated and unsheathed in and including 20mm dia non metalic rigid, medium grade PVC concealed conduit including cutting chasing for conduit and terminal boxes with all fittings /accessories and including 1.5 Sqmm FRLSH PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings including acessories as modular metal flush box 2mm thick surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and directed.
All as per srl item No 102 above but for 1 No 05 Amps Socket outlet independent board.
All as per srl item No 102 above but 05 Amps Socket outlet independent below the switch board.
All as per srl item No 102 above but for 1 No 05 Amps Socket outlet on the same board with other switches.
All as per srl item No 102 above but using cable size 2.5 Sqmm for 15 Amps Socket outlet with 2.5 sqmm earth wire.
S&F in replacement Glow Plug Top 16 Amps with Indicator complete all as specified & directed.
S&F sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified & directed.
S&F modular switch 6 Amp single pole one way-1 module complete all as specified & directed.
S&F modular switch 20 Amp single pole one way-2 module complete all as specified & directed.
S&F modular socket outlet shuttered-6A-2/3Pin-universal India 2 Module complete all as specified & directed.
S&F modular socket outlet shuttered-6/16A-2/3Pin Indian 2 Module ccomplete all as specified & directed.
S&F Fan step regulator 120W - 2 module complete all as specified & directed.
S&F in replacement of LED Fitting 2x2 ft recessed type 36 W LED complete including connection with 1.5 Sqmm 3 core flexible copper conductor cable. complete all as specified & directed.
M&L for Modular Bell push 6 Amp 2 Module complete all as specified & directed.
M&L in replacement Bell AC 230Volts single Pole complete all as specified & directed.
S&F in replacement LED 10 Watt fitting batten with decorative end cap with aluminium housing & integral electronic driver with tube 10 watt incl connection with 1.5 Sqmm 2 core flexible copper conductor cable complete all as specified & directed.
S&F in replacement LED 10 watt surface mounted downlight of size 200mm dia with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency complete including connection with 1.5 Sqmm 2 core flexible copper conductor cable complete all as specified & directed.
S&F in replacement LED 15 watt surface mounted downlight of size 200mm dia with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency complete including connection with 1.5 Sqmm 2 core flexible copper cable complete all as specified & directed.
S&F in replacement LED 18 Watt fitting batten with decorative end cap complete with aluminium housing & integral electronic driver with tube 20 watt complete including connection with 1.5 Sqmm 2 core flexible copper conductor cable. complete all as specified & directed.
S&F in replacement LED 20 Watt fitting batten with decorative end cap complete with aluminium housing & integral electronic driver with tube 20 watt complete including connection with 1.5 Sqmm 2 core flexible copper conductor complete all as specified & directed.
S&F in replacement of Electronic ballast 36 Watt complete all as specified & directed.
S&F in replacement of Electronic ballast 28 Watt for T5 fitting complete all as specified & directed.
S&F in replacement of FTL Rod 36 Watt complete all as specified & directed.
S&F in replacement of T5 28Watt tube rod complete all as specified & directed.
S&F in replacement of LED bulb 5 Watt (maxglow) B22 Base (6500 K) complete all as specified & directed.
S&F in replacement of LED bulb 7 Watt (maxglow) B22 Base (6500 K) complete all as specified & directed.
S&F in replacement of remote bells including battery and fixing arrangements complete all as specified & directed.
S&F in replacement of extension cord 4x1 5Amps sockets with 1.5 mtr power cable including 5 Amps Plug Top complete all as specified & directed.
S&F in replacement of extension cord 4x1 5Amps sockets with 4 mtr power cable including 5 Amps Plug Topcomplete all as specified & directed.
S&F in replacement of capacitor 2.5 mfd including connection complete all as specified & directed.
S&F in replacement of Pedstal Fan PVC body 400 mm dia having 03 Blade complete all as specified & directed.
S&F in replacement of exhaust fan PVC body 200mm dia having 05 Blade including connection and fixing on wall with nuts bolts washers etc complete all as specified & directed.
S&F in replacement of exhaust fan PVC body 250mm dia having 05 Blade including connection and fixing on wall with nuts bolts washers etc complete all as specified & directed.
M&L for MCB TP&N distribution board suitable TPN 4 Way double door 415 Volts complete all as specified & directed.
S&F sheet metal enclosure for DBs 16 Way single Pole and Neutral with acrylic door having 200 Amps rated copper bus bar 240 Volts AC complete all as specified & directed.
S&F sheet metal enclosure for DBs 12 Way single pole and neutral with acrylic door having 200 Amps rated copper bus bar 240 Volts AC complete all as specified & directed.
S&F sheet metal enclosure for DBs 08 Way single pole and neutral with acrylic door having 200 Amps rated copper bus bar 240 Volts AC complete all as specified & directed.
S&F in repair MCB TPN 63 Amps braeking capacity 10KA , 415 Volt complete all as specified & directed.
S&F in repair MCB SPN 40 Amps braeking capacity 10KA , 230 Volt complete all as specified & directed.
S&F in repair MCB SP 06 to 32 Amps braeking capacity 10KA , 230 Volt complete all as specified & directed.
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified & directed.
S&F ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified & directed.
M&L for sub main wiring complete using 4 run of 10 sqmm and two run of 10 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor ISI marked 1100 V grade cable in existing concealed PVC conduit fixed in wall/floor,passing through wall/ceiling including taking out old unserviceable wiring complete all as specified and directed. Note : Six run of 10 Sqmm cable shall be measured as one unit (RM)
M&L for sub main wiring 2x4.0 sqmm and 1x4 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade in existing concealed conduit or fixed in wall/floor, passing through wall/ceiling including taking out old unserviceable wiring complete all as specified and directed. Note : Three run of 4 Sqmm cable shall be measured as one unit (RM).
M&L for sub main wiring with using 2x6.0 sqmm and 1x6 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor cable ISI marked 1100 V grade in existing PVC concealed conduit or fixed in wall/floor,passing through wall/ceiling including taking out old unserviceable wiring complete all as specified and directed. Note : Three run of 6 Sqmm cable shall be measured as one unit (RM).
M&L for sub main wiring with using 2x10 sqmm and 1x10 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor cable ISI marked 1100 V grade in existing PVC conduit fixed in wall/floor,passing through wall/ceiling including taking out old unserviceable wiring complete all as specified and directed. Note : Three run of 10 Sqmm cable shall be measured as one unit (RM).
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover.
M&L Galvanised iron strip 25x4mm buried in ground including necessay excavation & earth work in soft/loose soil and removal of excavated naterial n. exc 50m and depositing where complete all as specified and directed.
S&F in repair MCCB Four pole 400 Amps 36KA complete all as specified and directed.
S&F in repair MCCB Four pole 250 Amps 36KA complete all as specified and directed.
S&F in repair MCCB Four pole 160 Amps 36KA complete all as specified and directed.
S&F in repair MCCB Four pole 100 Amps 25KA complete all as specified and directed.
S&F in repair RCCB Double Pole 63A(30mA) complete all as specified and directed.
S&F in replacement RCCB Double Pole 40A(30mA) complete all as specified and directed.
S&F in replacement RCCB Four Pole 63A(30mA) complete all as specified and directed.
S&F in repair PVC conduit 25mm dia including fittings/accessories concealed in wall including cutting chasing and making good to disturb surfaces complete all as specified and directed.
S&F in replacement PVC Sheathed copper conductor cable 1.5 Sqmm 3 core complete all as specified and directed.
S&F in replacement PVC Sheathed copper conductor cable 2.5 Sqmm 3 core complete all as specified and directed.
S&F in replacement heating element 1.5 KW triangular type for 25Ltr hot water heater including connection complete all as specified and directed.
S&F in replacement heating element 2.00 KW for 50Ltr hot water heater including connection complete all as specified and directed.
S&F in replacement inlet/outlet assembly to matching the existing 25/50 Ltr capacity geyser inclding fixing and testing complete all as specified and directed.
S&F in replacement copper water tank suitable for 25 Ltr geyser including proper fixing and testing after repair complete all as specified and directed.
S&F in replacement copper water tank suitable for 50 Ltr geyser including proper fixing and testing after repair complete all as specified and directed.
S&F in repalcement thermostat switch for 25/50 Ltr geyser including LED indicator lamp complete all as specified and directed.
Supply and fixing in repair Geyser 25 Ltr capacity 5 star rating having copper inner tank including fixing on wall complete all as specified and directed.
Supply and fixing in repair Geyser 50 Ltr capacity 5 star rating having copper inner tank complete including fixing on wall complete all as specified and directed. Note for item No. 166 & 167 - Old unserviceable geysers shall be deposited in E/M Store Yard.
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable, FRLSH PVC insulated and unsheathed in PVC casing & caping double lock including fixtures and terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper conductor earth wire connected common earth with terminal boxes for Modular fittings including acessories as modular surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point including taking out old unserviceable complete all as specified and directed.
All as per srl item No 168 above but for 1 No 05 Amps Socket outlet independent board.
All as per srl item No 168 above but using cable size 2.5 Sqmm for 15 Amps Socket outlet terminal boxes for Modular switches including acessories as moduler surface cover plate with frame, metal flush box with 2.5 sqmm earth wire complete all as specified and directed.
S&F in replacement switch piano type flush type single pole one way 5 Amps complete all as specified and directed.
S&F in replacement socket outlet 2 in one 3 Pin 5 Amps complete all as specified and directed.
S&F in replacement switch piano type flush type single pole one way 15 Amps complete all as specified and directed.
S&F in replacement socket outlet 2 in one 3 Pin 5 & 15 Amps complete all as specified and directed.
S&F in replacement LED tube rod 18/20 watt double side connection complete all as specified and directed.
S&F in replacement LED tube rod 20/22W double side connection complete all as specified and directed.
S&F in replacenent PVC connection 600mm long with brass Nut with rubber washer suitable hot/cold water complete all as specified and directed.
S&F in replacement modular cover plate with frame 3 module complete all as specified and directed.
S&F in replacement modular cover plate with frame 4 module complete all as specified and directed.
S&F in replacement modular cover plate with frame 6 module complete all as specified and directed.
S&F in replacement modular cover plate with frame 8 module complete all as specified and directed.
M&L for rewinding of Exhaust fan with super enamelled copper winding wire of suitable gauge, varnishing material including cleaning and removing all dust etc, fixing, connecting with 3 Core 1.5 Sqmm copper conductor flexible cable and testing after repair complete all as specified and directed.
S&F in replacement Ceiling fan 1200 mm sweep three blade white colour BLDC Type 5 star rating inclding all fixing material and testing complete all as specified and directed.
S&F in replacement of Ceiling fan 1400 mm sweep three blade white colour BLDC Type energy efficient inclding all fixing material and testing complete all as specified and directed. Note : For item No. 183 & 184- Old unserviceable ceiling fan shall be deposited in E/M Store Yard.
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable FRLSH PVC insulated and unsheathed in existing PVC counduit including fixtures and terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings including acessories as modular surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point including taking out old unserviceable complete all as specified and directed.
All description as per srl item No 185 above but for 1 No 05 Amps Socket outlet independent .
All as per srl item No 185 above but 15 Amps Socket outlet terminal boxes for Modular switches including acessories as modular surface cover plate with frame, metal flush box with 2.5 sqmm earth wire complete all as specified and dierected.
Taking down old unserviceable ceiling fan and rewinding with super enamelled copper winding wire of existing gauge including varnish material and replacement of capacitor 2.5 mfd and painting of ceiling fan including fan blade and fixing the same in existing position and connecting with 1.5 Sqmm 3 core copper conductor cable complete all as specified and directed.
S&F in replacement of capacitor 4 mfd including connection complete all as specified and directed.
S&F in replacement GI Wire 4 mm dia for connecting earthing complete all as specified and directed.
M/s Adhikari construction co.
DP COMPLEX
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .