Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHATRAPATI SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKTA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹17.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹21.6 LRejected-Finance | ₹21.6 L | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹23.0 LRejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹23.0 L | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹24.0 LRejected-Finance | ₹24.0 L | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹24.1 LRejected-Finance | ₹24.1 L | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | somnath engineering corporation L2 | pk Enterprises L6 | BRITE INDUSTRIES L5 | Shree Ayyappa Engineering L3 | cooltech engineering services L1 | ENJOY L7 | AIRCON SYSTEMS L8 | PAUL REFRIGERATION L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing copper/aluminium point wiring (socket/power) complete, including associated fixtures and fittings such as sockets etc.; removing materials to store for safe custody or for taking credit (credit for above items shall be made as per conditions separately); and making good disturbed surfaces of walls, floors etc., complete all as specified and as directed. | 29 | Point | 100 ₹2,900 | 50 ₹1,450 | 41 ₹1,189 | 32 ₹928 | 15 ₹435 | 34 ₹986 | 38 ₹1,102 | 50 ₹1,450 |
| 2.00 | M&L for point wiring for 3-pin socket outlet, 15 Amps with stranded copper conductor cable 4.0 sqmm, 1100 V grade PVC insulated FRLS cables, ISI marked, drawn through and including suitable size PVC casing-capping fixed on surface on walls/ceiling/roof, including suitable copper earth wire 4.0 sqmm PVC insulated FRLS cable connected to common earth point; wiring to be independent, complete all as specified and as directed. | 29 | Point | 850 ₹24,650 | 10,000 ₹2.9 L | 6,400 ₹1.9 L | 4,300 ₹1.2 L | 1,600 ₹46,400 | 8,700 ₹2.5 L | 4,370 ₹1.3 L | 4,600 ₹1.3 L |
| 3.00 | Supply and fix in repairs switch socket combination, 3-pin 16A, flush type industrial socket 16A with fuse and neon indicator, complete all as specified and as directed. | 29 | Each | 250 ₹7,250 | 2,600 ₹75,400 | 3,450 ₹1.0 L | 2,200 ₹63,800 | 1,500 ₹43,500 | 6,500 ₹1.9 L | 3,578 ₹1.0 L | 2,300 ₹66,700 |
| 4.00 | Supply and fix in repairs split air conditioner (inverter type) comprising indoor unit and outdoor unit, 1.5 TR capacity, minimum 5-Star BEE rating (as per latest guidelines) with ISEER not less than 5.05 (or better), suitable for operation up to 52°C ambient temperature, complete with cordless remote, and features such as 5-in-1 convertible cooling mode, 4-way swing, turbo/eco/dry/sleep modes, self-diagnosis, hidden display, and air filtration/ioniser as per OEM, complete with 100% copper evaporator and condenser coils with anti-corrosive blue fins (or equivalent protection), including indoor unit fixing arrangement, interconnecting refrigerant piping with insulation, drain piping, interconnecting power/control cabling, necessary clamps/saddles, vacuuming, pressure testing, charging (if required), testing and commissioning, including making good the disturbed surface in all respect complete all as specified and as directed.
Note:
(i) Old unserviceable AC units shall be dismantled and deposited at AGE E/M store yard as directed.
(ii) Minimum 5 years on product and 10 years on compressor (as per OEM T&C), warranty card/ user manual shall be handed over to Department. | 29 | Each | 64,500 ₹18.7 L | 55,000 ₹15.9 L | 65,480 ₹19.0 L | 63,000 ₹18.3 L | 51,700 ₹15.0 L | 57,000 ₹16.5 L | 68,970 ₹20.0 L | 65,500 ₹19.0 L |
| 5.00 | Supply and fix voltage stabilizer for automatic operation, single phase, naturally air-cooled indoor type, designed for input variation 170 V to 250 V, with output voltage stabilized at 230 V with accuracy ±2.5%, capacity 4 kVA complete all as specified and as directed. | 29 | Each | 4,250 ₹1.2 L | 7,000 ₹2.0 L | 2,450 ₹71,050 | 4,100 ₹1.2 L | 2,500 ₹72,500 | 6,500 ₹1.9 L | 4,750 ₹1.4 L | 4,200 ₹1.2 L |
| 6.00 | Supply and fix in repairs copper tubing 25 SWG wall thickness, conforming to ASTM B68, made from 99% pure copper, carbon-free inside, with bright finish of std size/ dia including cutting to length, bending, flaring/crimping as required, brazing/soldering where necessary, and making connections complete, from indoor unit to outdoor unit suitable for 1.5 ton split AC, complete all as specified and as directed. | 52 | RM | 1,600 ₹83,200 | 400 ₹20,800 | 2,300 ₹1.2 L | 1,689 ₹87,828 | 700 ₹36,400 | 1,500 ₹78,000 | 1,678 ₹87,256 | 1,900 ₹98,800 |
| 7.00 | Supply and fix in repairs heavy duty wall mounted outdoor unit stand fabricated out of MS steel of minimum 2.0 mm thickness, powder coated for corrosion resistance, suitable for mounting split AC outdoor unit (1.5 TR), having minimum safe load capacity 300 kg, complete with pre-drilled mounting holes, all necessary nuts, bolts, washers, clamps/fasteners, including fixing to wall/structure, alignment and making good, complete all as specified and as directed | 29 | Each Set | 1,500 ₹43,500 | 8,000 ₹2.3 L | 1,100 ₹31,900 | 2,650 ₹76,850 | 1,200 ₹34,800 | 3,500 ₹1.0 L | 3,546 ₹1.0 L | 2,750 ₹79,750 |
Tender Value
₹23.4 L
EMD Value
₹46,800
Closing Date
14 Mar 2026, 6:00 pmClosed
GE (SB) KARWAR
GARRISON ENGINEER (SEABIRD) KARWAR Naval Base, Sankrubagh (PO) Karwar - 581308
SPECIAL REPAIRS REPLACEMENT OF BER SPLIT ACs AT SITE E UNDER GE(SB) KARWAR
2026_MES_753590_1
8467/E8
Open Tender
Electrical and Maintenance Works
180 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (SB) KARWAR
₹46,800
Yes
24 Apr 2026
20 Feb 2026
16 Mar 2026
20 Feb 2026
14 Mar 2026
7 Mar 2026
20 Feb 2026 - 27 Feb 2026
Taking down existing copper/aluminium point wiring (socket/power) complete, including associated fixtures and fittings such as sockets etc.; removing materials to store for safe custody or for taking credit (credit for above items shall be made as per conditions separately); and making good disturbed surfaces of walls, floors etc., complete all as specified and as directed.
M&L for point wiring for 3-pin socket outlet, 15 Amps with stranded copper conductor cable 4.0 sqmm, 1100 V grade PVC insulated FRLS cables, ISI marked, drawn through and including suitable size PVC casing-capping fixed on surface on walls/ceiling/roof, including suitable copper earth wire 4.0 sqmm PVC insulated FRLS cable connected to common earth point; wiring to be independent, complete all as specified and as directed.
Supply and fix in repairs switch socket combination, 3-pin 16A, flush type industrial socket 16A with fuse and neon indicator, complete all as specified and as directed.
Supply and fix in repairs split air conditioner (inverter type) comprising indoor unit and outdoor unit, 1.5 TR capacity, minimum 5-Star BEE rating (as per latest guidelines) with ISEER not less than 5.05 (or better), suitable for operation up to 52°C ambient temperature, complete with cordless remote, and features such as 5-in-1 convertible cooling mode, 4-way swing, turbo/eco/dry/sleep modes, self-diagnosis, hidden display, and air filtration/ioniser as per OEM, complete with 100% copper evaporator and condenser coils with anti-corrosive blue fins (or equivalent protection), including indoor unit fixing arrangement, interconnecting refrigerant piping with insulation, drain piping, interconnecting power/control cabling, necessary clamps/saddles, vacuuming, pressure testing, charging (if required), testing and commissioning, including making good the disturbed surface in all respect complete all as specified and as directed. Note: (i) Old unserviceable AC units shall be dismantled and deposited at AGE E/M store yard as directed. (ii) Minimum 5 years on product and 10 years on compressor (as per OEM T&C), warranty card/ user manual shall be handed over to Department.
Supply and fix voltage stabilizer for automatic operation, single phase, naturally air-cooled indoor type, designed for input variation 170 V to 250 V, with output voltage stabilized at 230 V with accuracy ±2.5%, capacity 4 kVA complete all as specified and as directed.
Supply and fix in repairs copper tubing 25 SWG wall thickness, conforming to ASTM B68, made from 99% pure copper, carbon-free inside, with bright finish of std size/ dia including cutting to length, bending, flaring/crimping as required, brazing/soldering where necessary, and making connections complete, from indoor unit to outdoor unit suitable for 1.5 ton split AC, complete all as specified and as directed.
Supply and fix in repairs heavy duty wall mounted outdoor unit stand fabricated out of MS steel of minimum 2.0 mm thickness, powder coated for corrosion resistance, suitable for mounting split AC outdoor unit (1.5 TR), having minimum safe load capacity 300 kg, complete with pre-drilled mounting holes, all necessary nuts, bolts, washers, clamps/fasteners, including fixing to wall/structure, alignment and making good, complete all as specified and as directed
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender8467.pdf
Tender Documents • 0.41 MB
BOQ_844066.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid