Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 CrAccepted-AOC | ₹8.4 Cr | L1 | Accepted-AOC Being the Lowest and Reasonable Tender |
| 2 | L2₹8.6 Cr+₹25.7 L (3.08%)Rejected-Finance | ₹8.6 Cr+₹25.7 L (3.08%) | L2 | Rejected-Finance Not being the lowest |
| 3 | L3₹8.9 Cr+₹57.5 L (6.88%)Rejected-Finance NOT SPECIFIED | ₹8.9 Cr+₹57.5 L (6.88%) | L3 | Rejected-Finance Not being the lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to firm is two classes below eligible class. |
Tender Value
₹8.3 Cr
EMD Value
₹7.4 L
Closing Date
26 Jan 2022, 6:00 pmClosed
CE (Navy) Mumbai
Headquarters Chief Engineer (Navy) Mumbai, 26, Assaye Building, Colaba, Mumbai -400 005
PROVISION OF DEFICIENT CIVILIAN MARRIED ACCOMMODATION (TYPE V, IV AND III) FOR CE (NAVY) MUMBAI AT COLABA, MUMBAI
2021_MES_481825_2
87906/E8
Open Tender
Civil Works
Lump-sum
540 days
Colaba
As per tender documents
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (P) No 01 NW Mumbai
₹7.4 L
Yes
12 Apr 2023
29 Dec 2021
28 Jan 2022
29 Dec 2021
26 Jan 2022
12 Jan 2022
Amount
SCHEDULE "A" Part - I (BUILDINGS & STRUCTURES WORKS) Total of Sch-'A' Part-I B/F
SCHEDULE "A" PART-II (SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK) Total of Sch-'A' Part-II B/F
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Total of Sch-'A' Part-III B/F
SCHEDULE "A" PART-IV (INTERNAL ELECTRICFICATION) Total of Sch-'A' Part-IV B/F
SCHEDULE "A" PART-V (HARDSTANDING) Total of Sch-'A' Part-V B/F
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Total of Sch-'A' Part-VI B/F
SCHEDULE "A" PART-VII (AREA DRAINAGE) Total of Sch-'A' Part-VII B/F
SCHEDULE "A" PART-VIII (EXTERNAL ELECTRIFICATION) Total of Sch-'A' Part-VIII B/F
SCHEDULE "A" PART-IX (EXTERNAL WATER SUPPLY) Total of Sch-'A' Part-IX B/F
SCHEDULE "A" PART-X (FIREFIGHTING) Total of Sch-'A' Part-X B/F
SCHEDULE "A" PART-XI ( LIFTS ) Total of Sch-'A' Part-XI B/F
SCHEDULE "A" PART-XII ( LIGHTNING PROTECTION ) Total of Sch-'A' Part-XII B/F
SCHEDULE "A" PART-XIII (CONDUITS) Total of Sch-'A' Part-XIII B/F
SCHEDULE "A" PART -XIV (MISCELLANEOUS ITEMS)
SITE CLEARANCE & EARTHWORK
Removing excavated material (any type) and depositing it outside Ministry of Defence Land. Notes: (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site. (iii) All excavation earthwork covered under Sch'A' part III to part XIV shall be measured and paid under this item.
INTERNAL WATER SUPPLY
S & F Chromium plated angular stop cock quarter turn (wall mount) with 15 mm diameter. Make-Jaguar Model no CQT-23059 or equivalent in Crab tree/Kohler
S & F Overhead shower rose 80 mm dia (ABS body chromium plated for fixing shower arm 15 mm size with bend of 15 degree with flange. Make -Jaguar Model No OHS-CHR-1989 or equivalent in Crab tree/Kohler
S & F Chromium plated wall mixture with provision for overhead shower connection with 115 mm long bend pipe on upper side, connecting legs & wall flanges. Make -Jaguar Model No 23281 UPR GD or equivalent in Crab tree/Kohler
S & F Chromium plated Health faucet (ABS body) with 01 mtr long PVC tube and wall hook. Make -Jaguar Model No ALD -CHR-583 or equivalent in Crab tree/Kohler
S & F 40 mm Brass forged pressure reducing valves complete all as specified. Make- Zoloto, Kirloskar, Leader, Upadhyaya or equivalent.
S & F 32 mm Brass forged pressure reducing valves complete all as specified. Make- Zoloto, Kirloskar, Leader, Upadhyaya or equivalent.
S & F Sink cock with swinging casted round shape spout (Wall mounted model) 20 mm dia, quarter turn Make - Jaquar Model No CQT-23347 or equivalent in Crab Tree/Kohler brand.
INTERNAL ELECTRIC SUPPLY
S & F modular Electronic regulator 5 steps FSC type 2M Make- Havells cat No AHFRFXW005 or equivalent in Legrand /ABB
S & F Modular Electronic 2M chime ding dong AC-230 Volt. Make : Legrand cat No 57333 or equivalent model of Havells, MK.
S & F Modular type 25A SP 'C' MINI MCB breaking capacity 10 KA of rating all as directed. Make : Havells model No :- DHFNCSPA025 or equivalent in L&T, ABB, Schneider ( For AC)
S & F Modular Socket 25 A shuttered Socket all as directed. Make : Havells model No :- AHFKCXW253 or equivalent in L&T, ABB, Schneider (For AC)
S & F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. Make : HAVELLS Cat No :- ES Neo or equivalent in Crompton Greaves, Bajaj, Orient
S & F Exhaust fan 200 mm sweep PVC body Range complete and shutters including required length and size of copper stranded conductor for connection from ceiling rose to connector of fan with provn of making hole in wall complete with grouting of nuts, bolts and washers and all other accessories required for fixing of fan including testing on completion. Make - Havells cat no :- Ventil Air -DX White or equivalent in Bajaj, Crompton
S & F Fresh air Exhaust fan of size 300 mm sweep Metallic body complete with and shutters including required length and size of copper stranded conductor for connection from ceiling rose to connector of fan with provn of nuts, bolts and washers and all other accessories required for fixing of fan including testing on completion Make :Havells cat no :- Ventil Air -DS or equivalent in Bajaj, Crompton
S & F of Exhaust fan aluminium louvers size 300x300mm with provn of making hole in wall complete with grouting of nuts, bolts and washers and all other accessories required for fixing of fan including testing on completion all as specified and directed. MAKE: Crompton Cat-Part No. EXHD300- 4-1 or equivalent model of Havells Cat-Part No. Ventil Air - DSP or BAJAJ Cat-Part No. Max Air
S & F LED tube light fittings decorative ultra slim linear fixture with extruded aluminium heat sink environmental friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block etc. with all accessories internally prewired & including connecting up with 2 core flexible copper conductor cable with suitable size & suitable for and mounting clamps PVC square box 75x75mm - 2 nos etc. Make-HAVELLS Cat no LHEXBXPNIN1W020 or equivalent in WIPRO, Crompton, PHILLIPS
S & F LED tube light fittings decorative ultra slim linear fixture with extruded aluminium heat sink environmental friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block etc. with all accessories internally prewired & including connecting up with 2 core flexible copper conductor cable with suitable size & suitable for and mounting clamps PVC square box 75x75mm - 2 nos etc. Make-HAVELLS Cat no LHEXBXPNIN1W010 or equivalent in WIPRO, Crompton, PHILLIPS
S & F LED tube light fittings decorative ultra slim linear fixture with extruded aluminium heat sink environmental friendly Energy efficient ready to use pack ,1x5 Watt ( for mirror light) ,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block etc. with all accessories internally prewired & including connecting up with 2 core flexible copper conductor cable with suitable size & suitable for and mounting clamps PVC square box 75x75mm - 2 nos etc all as specified and as directed. Make-HAVELLS CAT NO LHEXBXPNIN1W005 or equivalent in WIPRO, Crompton, PHILLIPS
S & F deep drawn Rugby bulk head fitting 9/10 watt cast aluminium housing& frosted glass. Body epoxy white powder coated heat resistant prismatic glass cover with specially designed gasket complete all as specified and as directed. Make : Crompton Cat No ; LBHE-10CDL or equivalent in Havells, SYSKA, Wipro
S & F LED Security/Street light fittings 25 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, etc. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size etc and fix GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm MS flat & fixed with anchor bolt suitable for 25W security light fitting all as specified and as directed. Make- HAVELLS Cat No ; ENDURA PEARLS L25WLED757SASYTOPC or equivalent in WIPRO , JAQUAR, PHILLIPS
S & F Geyser electric water heater,storage type steel body with copper inner tank and heating element upto 2KW,BEE 5 star rated ,25 Ltr capacity with all accessories such as safety valve, thermostate,NRV, connection piece incl with provn of making hole in wall complete with grouting of nuts, bolts and washers and all other accessories required for fixing of fan including testing on completion. Make:- Havells cat No (Quatro)GHWEQTTIB025 or equivalent in Bajaj, Venus, Racold
EXTERNAL ELECTRIFICATION
Supply Installation, testing and commissioning of LED type street light fitting suitable for 70 watt capacity LED lamp ,IP 66 pressure die cast housing with epoxy powder coated aluminium housing dark graphite gray colour finish Enclosure complete with control driver ,fixed on street light pole connecting with 1.5 sqmm 3 core copper cable from street light connector to junction box with suitable size lugs/thimble complete all as specified and directed by Engineer-in-Charge. Make:- Havells Cat Part No. ENDURA PEARL PLUS LHETBXU7OA7B070 or equivalent in Philips, Wipro, GE, Crompton.
Supply and fixing PVC junction box consisting of bus bar of suitable rating and one no MCB SP upto 10 amps complete all as directed.
Supply, installation, testing and commissioning Main LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ, indoor type,cubicle , floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting , CPRI approved,separate compartment for ACB/MCCB/metering equipments/cable gallery etc,Front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50mmx50mmx6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer-in-Charge comprising of following:- Incomer (a) 600 A rated copper bus bar with colour coded heat shrinkable sleeve (b) MCCB 4 Pole, 400 A, 415V, 35 KA with microprocessor based release - 01 No. (In coming)
(c) MCCB 3 Pole, 250 A, 415V, 35 KA - 01 No. (Out going) (for APFC Panel) (01 No) (d) MCCB 4 Pole, 100A, 415V, 25 KA - 03 Nos. (Out going) (02 Nos for Type - (V,IV) , (III) Qtrs & 01 No. for Spares) (e) MCB SP , 6A, 230 V, 10 KA - 02 Nos. (Out going) (for Sub stn lightening) (f) Ammeter, Digital type, with suitable CTs of suitable capacity - 01 set (g) Voltmeter, Digital type of suitable capacity- 01 No. (h) R-Y-B phase indicating lamp- 01 set (j) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.
Supply, installation, testing and commissioning of Main LT panel, indoor type cubical panel board, (UTILITY PANEL) made out of 2mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangements, weather and vermin proof with proper ventilation slots, IP 52 free standing floor mounted with copper busbar of suitable size for phase and neutral mounted on hygroscopic insulators including necessary PCC foundation and all as specified and directed by Engineer-in-Charge & provn of two Nos extra space for providing MCCB for future expansion including comprising of the following:- (a) 150 A rated copper bus bar with colour coded heat shrinkable sleeve (b) MCCB 4 Pole, 100A, 415V, 25 KA with microprocessor based release - 01 No. (In coming) (c) MCCB 4 Pole, 63 A, 415V, 25 KA - 01 Nos. (Outgoing for Lift 13 PS , 08 PS Lift ) (d) MCCB 4 Pole, 40 A, 415V, 25 KA - 02 Nos. (Outgoing for Goods Lift and Domestic water supply Pumps) (e) MCCB 4 Pole, 32 A, 415V, 25 KA - 02 Nos. (Outgoing for 01 Booster pump and 01 No Spare ) (f) DOL Starter 15 HP -01 Nos ( For Booster Pumps) (g) MCB 3 Pole, 16 A, 415V, 16 KA - 02 No. (Out going) (for common area lighting and street lights) (h) MCB SP 6 A, 230 V - 01 No. (01 No. for aviation light) (j) Ammeter, Digital type, with suitable CTs of suitable capacity - 01 set (k) Voltmeter, Digital type of suitable capacity- 01 No.
(l) R-Y-B phase indicating lamp- 01 set (m) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled. (n) Supply, installation, testing and commissioning of intelligent street light control Alpharex3 digital time switches - Astro suitable for 2 kW maximum load, wall/pole mounted, having built-in networking support, built-in astronomical timer, with combination function for creating switching programs in which the devices are switched according to astronomical time and/or fixed pre-set times, Daily astronomical calculation of the sunrise/sunset times based on the entered location with suitable contactor of 25A rating, 25 A SPN MCB all complete as specified and directed - 01 No (For street light control)
Supply, installation, testing and commissioning of Main LT panel, indoor type cubical panel board, (BUILDING PANEL) made out of 2mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangements, weather and vermin proof with proper ventilation slots, IP 52 free standing floor mounted with copper busbar of suitable size for phase and neutral mounted on hygroscopic insulators including necessary PCC foundation and all as specified and directed by Engineer-in-Charge & provn of two Nos extra space for providing MCCB for future expansion including comprising of the following:- (a) 150 A rated copper bus bar with colour coded heat shrinkable sleeve (b) MCCB 4 Pole, 125A, 415V, 25 KA with microprocessor based release - 01 No. (In coming) (c) MCCB 4 Pole, 63A, 415V, 25 KA - 03 Nos. (Type - V,IV & III Qtrs) (c) MCCB 4 Pole, 40A, 415V, 25 KA - 02 Nos. (Type - Servant Qtrs) (d) MCB TPN, 32 A, 415V - 10 Nos. (For Type - V & IV Qtrs (08 Nos) & 02 Nos Spare) for three phase energy meter (e) MCB SPN, 32 A, 230V, - 18 No. (Out going) (for Type - III Qtrs (08 Nos) Servant Qtrs. (08Nos) for Single phase energy meter (e) MCB SPN, 16 A, 230V - 01 No. (Out going) (for meter room light and fan) (h) Smart Single Phase meter AC Single Phase Two Wire, tamper Proof, Static Meter of Class 1.0, 240V, 50 Hz, 10A-60A conforming to IS-16444 with optical communication port for Type III Qtrs- 08 Nos. Make: Secure/Schneider/L&T
(j) Smart Three Phase Meter AC Three Phase 4 Wire, tamper Proof, Static Meter of Class 1.0, 240V, 50Hz, 10A-60A conforming to IS-16444 with optical communication for Type V & IV Qtrs- 08 Nos. Make- Secure/ Schneider/ L&T (g) Ammeter, Digital type, with suitable CTs of suitable capacity - 01 set (h) Voltmeter, Digital type of suitable capacity- 01 No. (j) R-Y-B phase indicating lamp- 01 set (k) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.
M & L for earthing with galvanised steel earth plate electrode 60 x 60cm x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25metres deep below ground level )with top edge of the plate not less than 1.5 metres below ground level ,connected to galvanised earth strip 32 x 6mm by means of bolts, nuts ,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point including earth test point including excavation, earthwork, PCC pit, RCC cover 50mm thick, funnel with 20mmmdia medium grade GI watering pipe, wire mesh and testing on completion. (Ext Elec: 12 & Ext W/S: 10)
EXTERNAL WATER SUPPLY
Supply and Fix, 65mm dia Ball Foot Valve of cast iron body consisting of nitrile rubber coated ball, CI strainer, seat ring, fastener complete all as specified and directed by engineer-in-charge for iron pipe for unions and fixed. MAKE: Zoloto, Kirloskar, Leader
Supply, installation, testing and commissioning of Monoblock type centrifugal pump suitable for 5.8 LPS water flow and 36 MWC head (5 HP), self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed. Make :- Kirloskar/ Crompton/ CRI/ KSB Necessary civil work viz. foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work.
Supply, installation, testing and commissioning of Main LT panel, indoor type cubical panel board, (PUMP HOUSE PANEL) made out of 2mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangements, weather and vermin proof with proper ventilation slots, IP 52 free standing floor mounted with copper busbar of suitable size for phase and neutral mounted on hygroscopic insulators including necessary PCC foundation and all as specified and directed by Engineer-in-Charge & provn of two Nos extra space for providing MCCB for future expansion including comprising of the following:- (a) 100 A rated copper bus bar with colour coded heat shrinkable sleeve (b) MCCB 4 Pole, 40 A, 415V, 15 KA - 01 No. (c) DOL Starter 5 HP -02 Nos ( For Domestic Pumps) (d) MCB SPN 32 A, 415V, - 02No. (e) MCB SPN 6 A, 415V, - 02 No. (f) Ammeter, Digital type, with suitable CTs - 01 set (g) Voltmeter, Digital type of suitable capacity- 01 No. (h) R-Y-B phase indicating lamp- 01 set (i) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.
Cutting in position existing GI main pipe line of size 50 mm dia, insertion of GI tee 50 x 50 x 50 mm bore for tapping out for filling over tank including connected fittings and necessary excavation, refilling and disposal of surplus material complete as directed.
FIREFIGHTING
Supply, installation, testing & commissioning of 2c x 1.5 sq.mm Fire Survival Circuit Integrity unarmoured cable of 300/500V rated with Class-2 annealed copper conductor having crosslinkable ceramified Silicon insulation as per BS EN 50363 along with drain wire, aluminium tape screening and LSZH outer sheath. Should comply to BS 7629-1. Should meet fire performance circuit integrity test as per BS EN 50200 & BS 6387 CWZ (950 Deg. C for 3 hrs), outer sheath should be in red colour, cable shall be laid in concealed PVC conduits of 25mm dia medium grade with specials complete all as specified and directed.
BLANK
BLANK
BLANK
BLANK
TELEPHONE & TV WIRING
S & F RJ11 Telephone jack, modular type, single, with shutter, with pressed steel sunken box with top cover & base frame complete. Make : Anchor Roma Cat No. 20857 or equivalent model of Precision, CG, Legrand
S & F TV Socket outlet, modular type, single, with pressed steel sunken box with top cover & base frame complete. Make : Anchor Roma Cat No. 21157 or equivalent model of Precision, CG, Legrand
M & L for telephone cable with 2 pair un earmarked high conducting solid annealed copper conductor of size 0.5mm with polythene insulation paired polyester taped and re-trident PVC compound gray outer sheathed conforming to 11D/S/SW 113C all as specified & directed.
M & L for Co-axial cable with injected physical polythene foam insulated, laminated with aluminium tape and aluminium braid jelly fleaded and PVC black jacket type RG6 complete all as specified & directed.
S&F RJ45 Data Outlet cat 6 1M, modular type, single, with shutter, with pressed steel sunken box with top cover & base frame complete. Make: Havells SAP CODE :ACMKRWW451/Legrand/L&T or equivalent
S & F Cat 6 solid bare copper conductor 4 pair unshielded twisted pair(UTP) industrial cable for computer LAN network with grey colour & FR PVC jacket drawn through concealed conduit including termination with necessary required no of splitters complete all as specified and directed. Make: RR Kable HSN CODE: 8544/ Polycab CO-X/ Havells/ Legrand or equivalent
M&L for Double layer wall mounted shelf for wi-fi router suitable for living room/bed room of material painted/ laminated engineered wood/ sturdy plastic/ reinforced fiber as approved by Engr-in-charge duly fixed on wall with suitable fixing arrangement complete all as specified & directed
BLANK
LIFTS
Design supply, installation, testing & commissioning of 13 passenger lift, having 1.5 m/s car speed, single speed motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G + 8 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near ground floor landing door) complete all as specified and directed. Make: Otis, Schindler, Mitsubishi, Thyssenkrupp, Toshiba Johnson The lift shall conform to the following technical specifications. [i] Type of Lift: Passenger lift [ii] Load Capacity: 13 passenger (884kg) [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3-Ph, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 2.20 m² [viii] Car & Landing Door at all floors: COPD with VVVF door drive, opening size not less than 800 mm X 2000 mm, sliding type, fabricated by stainless steel not less than 16 gauge having hairline finish (N-304)
[ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection [x] Provision of standard thickness 40 mm diameter stainless steel hand-rail all around inside the car cabin incl standard size mirror [xi] Terminal Buffers: Metal special spring / PU / Oil buffers as per manufacturer's recommendation. The buffing stroke shall not be less than 200 mm. [xii] Door Opening (inside): Protected by COPD stainless steel door having hairline finish with opening not less than 800 mm X 2000 mm [xiii] Car & Counter Weight Guide: As per OEM recommendations [xiv] Flooring: 5 mm thick Alu. chequered plate / as per OEM design [xv] Signals: (a) Combined luminous hall buttons with LED / LCD / TFT hall position indicators at all floors (b) LED / LCD / TFT car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing
(e) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One fireman's switch to be installed at ground floor near landing door. (h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (i) Infrared door sensor safety edge of door for entire height (j) Built in announcing system without handset 03 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room (k) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance / exit door is open or closed [xvi] Stops & Opening: 09-09 with all openings being on the same side [xvii] Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open.
[xviii] Operation: Simplex, full collective automatic operation with and without attendant. [xix] Machine Room: Located above the hoist way, details as per building drawings [xx] Hoist way: Construction details as per building drawings [xxi] Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. [xxii] One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. [xxiii] Mirror of suitable size to be provided on complete wall opposite to main door above SS railing. [xxiv] Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor
Design supply, installation, testing & commissioning of Fire lift (13 passenger), having 1.5 m/s car speed, single speed motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G + 8 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near ground floor landing door) complete all as specified and directed. Make: Otis, Schindler, Mitsubishi, Thyssenkrupp, Toshiba Johnson The lift shall conform to the following technical specifications. [i] Type of Lift: Fire lift [ii] Load Capacity: 13 passenger [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3-Ph, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 2.20 m² [viii] Car & Landing Door at all floors: COPD with VVVF door drive, opening size not less than 800 mm X 2000 mm, sliding type, fabricated by stainless steel not less than 16 gauge having hairline finish (N-304)
[ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection [x] Provision of standard thickness 40 mm diameter stainless steel hand-rail all around inside the car cabin incl standard size mirror [xi] Terminal Buffers: Metal special spring / PU / Oil buffers as per manufacturer's recommendation. The buffing stroke shall not be less than 200 mm. [xii] Door Opening (inside): Protected by COPD stainless steel door having hairline finish with opening not less than 800 mm X 2000 mm [xiii] Car & Counter Weight Guide: As per OEM recommendations [xiv] Flooring: 5 mm thick Alu. chequered plate / as per OEM design [xv] Signals: (a) Combined luminous hall buttons with LED / LCD / TFT hall position indicators at all floors (b) LED / LCD / TFT car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing
(e) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One fireman's switch to be installed at ground floor near landing door. (h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (i) Infrared door sensor safety edge of door for entire height (j) Built in announcing system without handset 03 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room (k) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance / exit door is open or closed [xvi] Stops & Opening: 09-09 with all openings being on the same side [xvii] Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open.
[xviii] Operation: Simplex, full collective automatic operation with and without attendant. [xix] Machine Room: Located above the hoist way, details as per building drawings [xx] Hoist way: Construction details as per building drawings [xxi] Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. [xxii] One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. [xxiii] Mirror of suitable size to be provided on complete wall opposite to main door above SS railing. [xxiv] Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor.
Design supply, installation, testing & commissioning of 8 passenger lift, having 1.5 m/s car speed, single speed motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G + 8 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near ground floor landing door) complete all as specified and directed. Make: Otis, Schindler, Mitsubishi, Thyssenkrupp, Toshiba Johnson The lift shall conform to the following technical specifications. [i] Type of Lift: Passenger lift [ii] Load Capacity: 08 passenger (544kg) [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3-Ph, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 1.43 m² [viii] Car & Landing Door at all floors: COPD with VVVF door drive, opening size not less than 800 mm X 2000 mm, sliding type, fabricated by stainless steel not less than 16 gauge having hairline finish (N-304)
[ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection [x] Provision of standard thickness 40 mm diameter stainless steel hand-rail all around inside the car cabin incl standard size mirror [xi] Terminal Buffers: Metal special spring / PU / Oil buffers as per manufacturer's recommendation. The buffing stroke shall not be less than 200 mm. [xii] Door Opening (inside): Protected by COPD stainless steel door having hairline finish with opening not less than 800 mm X 2000 mm [xiii] Car & Counter Weight Guide: As per OEM recommendations [xiv] Flooring: 5 mm thick Alu. chequered plate / as per OEM design [xv] Signals: (a) Combined luminous hall buttons with LED / LCD / TFT hall position indicators at all floors (b) LED / LCD / TFT car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing.
(e) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One fireman's switch to be installed at ground floor near landing door. (h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (i) Infrared door sensor safety edge of door for entire height (j) Built in announcing system without handset 03 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room (k) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance / exit door is open or closed [xvi] Stops & Opening: 09-09 with all openings being on the same side [xvii] Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open.
[xviii] Operation: Simplex, full collective automatic operation with and without attendant. [xix] Machine Room: Located above the hoist way, details as per building drawings [xx] Hoist way: Construction details as per building drawings [xxi] Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. [xxii] One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. [xxiii] Mirror of suitable size to be provided on complete wall opposite to main door above SS railing. [xxiv] Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor.
M & L for earthing complete with copper earth plate 60cm×60cm×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to copper strip of size 20 mm x 3 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed. Notes: (i) The cost of copper earth continuity conductor with GI pipe 40mm light grade upto 7.5m is deemed to be included in r/o above item. (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item. (Lift - 06 No, Lightening Protection - 03 No)
COMPREHENSIVE MAINTENANCE OF LIFTS
Comprehensive maintenance and repairs of fully automatic electrically operated passenger lift (BOQ Item : 24.001 to 24.004 ) of any Make and installed capacity with a carrying capacity of 13 Passenger to serve (G+8 Floors) with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 36 months for all days including holidays etc after expiry of defects liability period as shown below and all as specified and directed to Engr-in-Charge for 01 no of lift Note : Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) through OEM as per MOU and maintain all the lifts in serviceable condition 24 hrs x 365 days with out any extra cost.
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of defects liability period
(c) 3rd year after expiry of defects liability period
Comprehensive maintenance and repairs of fully automatic electrically operate fire lift (BOQ Item : 24.005 to 24.008) of any Make and installed capacity with a carrying capacity of 13 Passenger to serve (G+ 8 Floors) with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 36 months for all days including holidays etc after expiry of defects liability period as shown below and all as specified and directed to Engr-in-Charge for 01 no of lift Note : Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) through OEM as per MOU and maintain all the lifts in serviceable condition 24 hrs x 365 days with out any extra cost.
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of defects liability period
(c) 3rd year after expiry of defects liability period
Comprehensive maintenance and repairs of fully automatic electrically operate Passenger lift (BOQ Item : 24.009 to 24.012) of any Make and installed capacity with a carrying capacity of 08 Passenger to serve (G+ 8 Floors) with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 36 months for all days including holidays etc after expiry of defects liability period as shown below and all as specified and directed to Engr-in-Charge for 01 no of lift Note : Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) through OEM as per MOU and maintain all the lifts in serviceable condition 24 hrs x 365 days with out any extra cost.
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of defects liability period
(c) 3rd year after expiry of defects liability period
NOTE:- (a) The contractor shall be responsible for periodical/routine maintenance, as per maintenance schedule recommended by manufacture / OEM, including renewal / replacement of parts, fittings / fixtures filling of refrigerant gas etc required for smooth functioning of the plant as per manufacturers instructions. The cost of all parts/component/Gas required for replacement are considered inclusive in quoted rate (b) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly. (c ) In case of non function of Lift penal recovery @ 3000 per day shall be effected 24 hrs after the defect is noticed or notified either in writing or through a social media message by GE or his rep. (d) Any defect in to a Motor ,ARD ,OLD,door drive , senser , limit switch ,Rope/belt ,Control Panel ,car panel with indicators, air circulating fan, Led lights & Misc Item shall be considered as outstanding defect & Panel charge will be applicable as above in Note (c ) (e) The maintenance of lifts will be carried out through OEM only. Contractor other than OEM if become lowest and awarded contract shall enter into an agreement with OEM for carrying out maintenance of lifts though OEM and copy of the contract between OEM and contractor shall be submitted to concerned GE for ref and record. (f) Payment against AMC shall be released only after submission of service report carried out on monthly basis by OEM of lift to Dept by Contractor
SANKALP INFRACON
United Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .