Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC | ₹2.2 Cr Quoted ₹2.7 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹2.8 Cr+₹6.8 L (2.47%)Rejected-Finance H NO 1900 SECTOR 3 THANESAR KURUKSHETRA HARYANA 136118 | KURUKSHETRA | HARYANA | 136118 | ₹2.8 Cr+₹6.8 L (2.47%) | L2 | Rejected-Finance Higher |
| 3 | L3₹2.8 Cr+₹8.1 L (2.97%)Rejected-Finance | ₹2.8 Cr+₹8.1 L (2.97%) | L3 | Rejected-Finance Higher |
| 4 | L4₹2.9 Cr+₹13.3 L (4.84%)Rejected-Finance 1550 3 KURUKSHETRA | KURUKSHETRA | HARYANA | 136030 | ₹2.9 Cr+₹13.3 L (4.84%) | L4 | Rejected-Finance Higher |
| 5 | L5₹3.0 Cr+₹24.3 L (8.89%)Rejected-Finance DISTT KARNAL | KARNAL | HARYANA | ₹3.0 Cr+₹24.3 L (8.89%) | L5 | Rejected-Finance Higher |
Tender Value
₹2.8 Cr
EMD Value
₹5.5 L
Closing Date
13 Feb 2020, 5:00 pmClosed
Amit Malik
Executive Engineer, Provincial Division No.2, PWD (B and R), Kurukshetra
Construction of Primary Health Centre and Housing of 550 sft (2 Nos.), 800 sft (4 Nos.) and 1300 sft (1 No.) at Village Barot, Ladwa District Kurukshetra.
2020_HRY_117610_1
PWD/AMB/KKR-2/16878
Open Tender
Construction Works
Works
450 days
Kurukshetra
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
E.E., Provincial Division No.2, PWD B and R Br.,
₹5.5 L
Yes
16 May 2020
7 Feb 2020
14 Feb 2020
7 Feb 2020
13 Feb 2020
7 Feb 2020
Amount
1 : - Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 Mtrs. (HSR 6.6)
2 : - Earth filling under floors with surplus soil excavated from foundation and taken only from outside the building plinth, in 15 cm layers including ramming watering and consolidating lead upto 30 meters. (HSR 6.13 a)
3 : - Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth (HSR 10.28)
4 : - Cement concrete 1:8:16 with stone aggregate 20 mm nominal size in foundation and plinth (HSR 10.29)
5 : - Cement concrete 1:4:8 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.38)
6 : - Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level (HSR 10.59)
7 : - Pre-cast cement concrete 1:11/2:3 with stone aggregate 20mm nominal size in Kerbs and the like items, finished smooth with 6mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete as per (HSR 10.77 + 10.95a)
8 : - Pre-cast factory manufactured cement concrete 1:11/2:3 with stone aggregate 20mm nominal size in tiles & channels and the like items, finished smooth with 6mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete as per (HSR 10.78 + 10.95a)
9 : - Cement concrete 1 :11/2 :3 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centering and shuttering, laid in position, complete in all respects. (HSR 10.81+ 10.95 (a) First Storey
: - Second Storey
10 : - Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respects. (HSR 10.82 + 10.95 (a) First Storey
: - Second Storey
: - Third storey/mumty
11 : - Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position complete in all respects. (HSR 10.86 + 10.95 (a)) First Storey
: - Second Storey
: - Third storey/mumty
12 : - Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work for circular or curved columns excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respect. (HSR 10.88+10.95a) First Storey
: - Second Storey
13 : - Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by item nos. 10.82, 10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects. (HSR 10.89+10.95(a)) First Storey
: - Second Storey
: - Third storey/mumty
14 : - Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc. excluding steel reinforcement and including centering and shuttering, laid in position, complete in all respects. (For works upto 1.5 meters below ground level (HSR 10.90 + 10.95 a)
15 : - Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate 20 mm nominal size with 2 coats of bitumen 20/30 preparation at 1.65 kg per sqm laid hot and sanded (HSR 10.114)
16 : - Providing and laying 80 mm thick ISI Marked interlocking paver blocks conforming to is 15658 : 2006/ IRC SP 63-2004 of all shapes and colours in design mix cement M-40 over a bed of 30 mm thick fine sand complete in all respect. (HSR 10.159)
17 : - First class brick work laid in cement sand mortar 1:6 in foundation and plinth. (HSR 11.2)
18 : - First class brick work laid in cement sand mortar 1:4 in foundation and plinth (HSR 11.4)
19 : - First class brick work laid in cement sand mortar 1:6 in first storey upto 4 meters above plinth level (HSR 11.7) First Storey
: - Second Storey
: - Third storey/mumty
20 : - First class brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level (HSR 11.9)
21 : - 11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure (HSR 11.48) (a) First Storey
: - Second Storey
22 : - Masonary work using flyash-lime based bricks (IS:12894-2002) laid in cement sand mortar 1:6 in super structure. (HSR 11.102). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. First Storey
: - Second Storey
: - Third storey/mumty
23 : - Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 Kg per sqm ontop of R.C.C. slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13) First Storey
: - Second Storey
: - Third storey/mumty
24 : - Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13.50) First Storey
: - Second Storey
: - Third storey/mumty
25 : - Supplying & fixing in position G.I pipe class 'B' spouts in chajjas and cantilevers. (HSR 13.55 (e) 50mm i/d G.I. pipe
26 : - Bottom Khurra on ground 1.2 m x 0.6 m consisting on brick-on-edge laid in cement mortar 1:3 over 75 mm cement concrete 1:8:16 including 12 mm thick cement plaster 1:3. (HSR 13.57)
27 : - Cement concrete 1:2:4 gola 10 cm x 10 cm quadrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64) First Storey
: - Second Storey
: - Third storey/mumty
28 : - Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (b) 150 mm dia PVC pipe 6 kg. pressure (Note:- Reputed make PVC Pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.89](b). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
29 : - Providing and fixing PVC Bend ISI Mark. (b) 150 mm dia PVC Bend (Note:- Reputed make PVC Bend such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.90](b). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
30 : - Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling. (HSR 14.1)
31 : - Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping (HSR 14.4) First Floor
: - Second floor/mumty
32 : - Conglomerate floor 50 mm thick cement concrete topping 1:2:4 (HSR 14.10)
33 : - Precast terrazzo tiles of 20 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry, between joints and over the base in floors, treads of steps and landings including rubbing and polishing (b) in 50% white and 50% grey cement (HSR 14.44 (b) Ground floor
: - First Floor
34 : - Precast chequered terrazzo tiles 22 mm thick in cement with marble chips of size and colour as required, laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry mixed with pigment to match the shade of tiles between joints and over the base in floors, treads of steps and landings, including rubbling and polishing (HSR 14.46)
35 : - Precast terrazzo tiles of 12.5 mm minimum thickness in cement as specified below with marble chips of size and colour as required laid on 10 mm thick cement coarse sand plaster 1:3 and jointed with neat cement slurry in skirting, dado and risers of steps, including rubbing and polishing complete (b) In 50% white and 50% grey cement (HSR 14.47) (b) Ground floor
: - First Floor
36 : - Extra for noising in marble stone for treads (HSR no 14.50) Ground floor
: - First floor
37 : - Kotah stone flooring minimum 25 mm thick in any pattern as specified over 12 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. Ground floor
: - First floor
38 : - Extra for noising in treads of steps of kotah stone slab (HSR. 14.65) Ground floor
39 : - Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. (HSR 14.66). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. Ground floor
: - First Floor/mumty
40 : - Providing and fixing aluminium strips 1.6 mm thick complete with nails in floors (HSR 14.77)
41 : - Providing & fixing vitrified tiles of size 600mm X 600mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO,KAJARIA, RAK,ORIENT BELL & SIMPOLO. Double charged tiles shall be used. (HSR 14.89) Ground floor
42 : - Laying and fixing rectified ceramic anti skid tiles of size 400x400mm of approved make in floors laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. (Tiles shall be supplied by the department) brands likeRAK, NITCO, KAJARIA, ORIENT BELL & SIMPOLO (as approved by the Engineer in charge) (HSR 14.91) Ground floor
43 : - Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete. a) size of ceramic glazed tiles 200x300mm (Make Nitco, Simpolo, Drientbell, RAK & Kajaria) (HSR 14.92 a) Ground floor
: - First floor
44 : - Providing & Fixing Ist quality Ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manu-facturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-In-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including ointing in white cement mixed with pigment of matching shades complete. (b) Size of ceramic Glazed tiles 300 x 450 mm of reputed manufacturer like:- RAK, NITCO, KAJARIA, ORIENT BELL & SIMPOLO shall be used as approved by Engineer-in-charge. [HSR 14.92(b)]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. Ground floor
45 : - Laying and fixing Granite stone in all shades 15mm to 18mm thick in skirting/dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite including labour for fixing cramps pins and dowels etc. (Excluding the cost of granite stone). (HSR 14.95) granite shall be supplied by the Deptt. Ground floor
46 : - Laying and fixing Granite stone in all shades 15 mm to 18 mm thick in flooring, laid in any pattern as specified over base of 20 mm thick cement coarsed sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite stone comp. in all respect. (Excluding the cost of granite stone). (HSR 14.96) granite shall be supplied by the Deptt. Ground floor
47 : - Providing and laying Baroda green marble stone 17 mm and above thick in risers of step, skirting, dado, pillars and wall linning included matching the grains of marble alab in any pattern as specified laid over 12 mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights/storey. The sample shall be got approved from Engineer in charge. (HSR 14.98) Ground floor
: - First floor
: - Second floor/mumty
48 : - Providing and laying Baroda green marble stone 17 mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12 mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights/storey. The sample shall be got approved from Engineer in charge. (HSR 14.99) Ground floor
: - First floor
49 : - Plastering on walls 10 mm thick cement plaster 1:3 (HSR 15.2) First storey
: - Second Storey
: - Third storey/mumty
50 : - Plastering on walls 12 mm thick cement plaster 1:4 (HSR 15.5) First storey
: - Second Storey
: - Third storey/mumty
51 : - Plastering on wall 12 mm thick cement plaster 1:6 (HSR 15.7) First storey
: - Second Storey
: - Third storey/mumty
52 : - Plastering on walls 15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12) Internal Plaster First storey
: - Second Storey
: - Third storey/mumty
53 : - 10 mm thick cement plaster 1:4 under side of ceiling (HSR. 15.52) Ground floor
: - First Floor
: - Second floor/mumty
54 : - Preparation of ply wood surface for painting inlcuding sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1)
55 : - Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.2).
56 : - Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3).
57 : - Applying priming coat with metal primer on new steel or iron work including preparation of surface. Painting on mettalic Surfaces etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.9).
58 : - Painting two coats excluding priming coat with ready mixed paint for matelic sufraces in all shades on new steel or iron work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.17).
59 : - Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces. (HSR 16.25)
60 : - Painting two coats with ready-mixed exterior paint in all shades on newly plastered or concrete exterior surface of walls . (HSR 16.26)
61 : - Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.58).
62 : - Finishing walls with exterior decorative cement based paints such as snowcem Robbiacem etc on new work, two coats to give an even shade (HSR 16.61)
63 : - Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). [HSR 16.79 (b)].
64 : - Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81)
65 : - Providing and fixing commercial type block board, plain lining, butt jointed, including wooden plugs (teak) placed at 45 cm to 60 cm centers, complete with necessary nails (frame work shall be payable extra) (b) 19 mm thick (HSR 17.49 (b)) First storey
: - Second storey
66 : - Providing and fixing 12 mm thick and 150 mm wide pelmet of commercial ply wood with 25 mm dia teak wood curtain rod and brackets including fixing with 25 mm x 3 mm MS flat, 10 cm long and plugs (Teak) etc. complete (HSR 17.63) + note (i) First storey
: - Second Storey
67 : - Providing & fixing 150 mm hasps and staples with necessary screws etc, complete. (HSR 17.78) (b) aluminium
68 : - Providing & fixing helical door spring 150 mm (Superior quality), including necessary screws, complete (HSR No. 17.79 (b) (Iron)
69 : - Providing & fixing 0.50 mm thick aluminium sheet including cost of necessary screws, etc. complete. (HSR 17.87) Fisrt storey
70 : - Factory manufactured panelled door or glazed window, shutters of commercial hard wood, such as hollock, champ, chikrassy & chaplash etc. (non-coniferous timber other than teak, conforming to I.S specification no. 1003, Kiln-seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panels of 15 mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges, screws, chocks/cleats, stops, nails etc. complete, fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) - (b) 35 mm thick. (HSR. 17.90(b)) - Note I under 17.18
71 : - Factory manufactured wire gauze door and window shutters of commercial hard wood such as hollock, champ, chikrassy annd chaplash, etc. (non coniferous timber other teak conforming to I.S specification no. 1003, kiln seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail 200 mm wide bottom rail, and wire gauze of 140 G or 120 G designation including cost of iron hinges, screws, chock/cleats, stops nails etc. complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) (i) 30 mm thick (HSR 17.92 (i) - Note I under 17.18
72 : - Factory manufactured solid flush door shutters, with block board core as der I.S. No. 1659-1669 bonded with water, proof type danol formaloehyde synthetic resin, hot-press as , conforming to I.S. 2202 part-I and II fixed in position including iron hinges screws chocks/cleats and stops, etc. (Excluding the cost of any fittings other than specified above, but including labour for fixing the same in position):- (Note) Commercial veneering with vertical grains or cross bands and face vaneer on both sides comercial facing with laminated core and lipped edges. Duro, Green make 25 mm. Thick (HSR 17.93(a) (i) - note I under 17.18)
73 : - Factory manufactured solid flush door shutters, with block board core as per I.S. No. 1659-1669 bonded with water proof type phenol formaldehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part-I and II fixed in position, including iron hinges, screws chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position):- (Note) :- Commercial veneering with vertical grains or cross bands and face veneer on both sides commercial facing with laminated core and lipped edges. 35 mm. Thick (HSR 17.93a iii- note I under 17.18))
74 : - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required neoprene felt etc. aluminium sections shall be smooth, rust free straight mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling C.P brass / stainless steel screws, all complete (HSR 17.95)+ note (i)
75 : - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS 733 and IS : 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. Aluminium sections shall be smooth, rust free straight mitred and jointed mechanically wherever required including cleat angle. Aluminium snap beading for glazing/paneling C.P brass/stainless steel screws, etc. complete. Shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required including aluminium fitting (HSR 17.96) + note (i) Add Rs. 15/- per kg. extra if powder coating of 50 micron is done instead of anodizing in above item no. 9 & 10.
76 : - Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 grade I type II in panelling fixed in aluminium doors. Windows shutters and partition frames with c.p brass / stainless steel screws etc. complete (HSR 17.97 b) Pre-laminated particle board with decorative lamination on both sides.
77 : - Providing and fixing glazing aluminium door, windows ventilator shutter and partitions etc. with PVC/neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basis items.) (HSR 17.98) (b) with float glass panes of 5.00 mm thickness
78 : - Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS 6315 marked for door including cost of cutting floors as required embedding in floors and cover plates with brass pivot and single piece M.S sheet outer box. (HSR 17.99 a) with stainless steel cover plate
79 : - Providing aluminium Jali of thickness 7mm thick with openings 75mm x 75mm of including anodizing and fixing frame with cost of screws etc complete (HSR 17.100)
80 : - Wrought iron and mild steel (using angles, flats, square bars, tees and channels), ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
81 : - Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights /depths/storeys/basements etc. (HSR 18.22) NOTE:- Reinforcement shall be measured in length including hocks, if any, separately for different diameters as actually used in work, excluding overlaps, Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
82 : - Supplying and fixing glass panes including special metal sash putty of approved make (b) Glass panes 4 mm thick, exceeding 40 sq.m areas. MODI, SAINTGOBAIN (HSR 18.30 B)
83 : - Pressed steel sheet frames (chowkhats) consisting of 2 mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D specifications, including bolts for fixing stops, lock notch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non-setting primer of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:3:6 for lungs complete. (a) Door and window frame of size 89 mm x 50 mm with 40 mm wide single rebate (Item no. 18.34 a) First, second & third storey/mumty
84 : - b) Door and window frame of size 76 mm 38 mm with 35 mm wide single rebate (Item no. 18.34 b)
85 : - d) Door and window frame of size 114 mm x 50 mm with 35 mm wide double rebate (HSR 18.34 d) First storey
86 : - Preparation of Sub Grade including trenching, rough dressing of soil, final dressing of earth to given levels and camber, watering rolling with road roller, and compacting the bed.(HSR 24.1)
87 : - N.S Items Earth filling under floors with tibba sand non plastic under floors with good earth taken from outside of campus area with all lead and lift including loading, unloading, laid in 15cm layer including ramming, watering, consolidating, compaction, and compensation of earth etc., complete in all respect as per the direction of engineer in charge. (For any lead lift). (NS items).
88 : - Providing and laying 200mm thick granular sub base consisting of drainage layer confirming to Table 400.1 Grading –VI of MORT&H 5th edition, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve desired density complete as per clause No.401 of MORT&H specifications for road & bridge (5th Revision) of 2013
89 : - Water Bound Macadam G-II (53 mm to 22.4 mm gauge): Providing, laying spreading and compacting 75 mm thick (av). Stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thicknes,, hand packing, rolling with 3 wheeled steel vibratory roller 8-10 tones in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density as per Clause of MORT &H Specificaiton No. 404. of MORT&H specifications for road & bridge (5th Revision) of 2013 as per drawing and design directed by the Engineer complete in all respects (NS)
90 : - Construction of Dry Lean cement concrete (M-10) Sub-Base over a prepared Sub grade with coarse and fine aggregate conforming to IS:3873, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum optimum moisture content to be determined during trial length construction, concrete strength not be less than as per ISI marked provision MPA at 7 days, mixed in the batching plant, transported to site laid with a paver, compacting with 5-10 tonnes vibratory roller, finishing and curing. Unit=cum, taking output=450 cum (990 tonne), taking batch mix plant of 15.20 cum as per MORT&H specification clause - 601 latest edition (N.S.)
1 : - PUBLIC HEALTH WORKS Excavation for pipe lines running under pressure in trenches and pits, in open areas, where disposal of surplus earth is done along with the alignment including trimming & dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, cutting trees and bushes, etc. refilling consolidation and watering of refill, in 15 cm layers and restoration of unmetalled or unpaved surface to its original condition, including the cost of dewatering of rain water, diversion of traffic, night signals, fixing caution boards, watching, fencing etc. and outside the town in ordinary soil:- (a) Without timbering and shoring upto 6.8
2 : - Excavation of trenches in streets, lanes or in open areas for storm sewer, sewers running by gravity and manholes to full depths as shown in drawings including shoring, timbering of poling boards, frame system type, dressing to correct sections and dimensions accordingly to templates and levels, dewatering, provision for diversion of traffic, cutting trees and bushed etc. night signals, profiles, pegs, sight rails, boning ends, crossing over trenches for access to the houses, watching fencing etc. fixing and maintence of caution board refilling of trenches, watering of refill, in 15 cm layers ramming and restoration of unmetalled or unpaved surface to original condition and removal of surplus soil, from site of work, upto a lead of 1 Km in ordinary soil: (a) For depths of excavation not exceeding 3 meters below ground level. 6.10 (a)
3 : - Boring for hand-pump in clay, fitting strainer and pipe (b) above 75 mm dia bore, but not exceeding 100 mm dia (i) from 0 to 15 meter HSR 26.10 (b) (i)
4 : - Drilling and tapping cast iron pipe line of all diameters and screwing in ferrule and connections. 40mm I/d 28.22
5 : - Cutting holes upto 23 cm square through brick work in mud walls for pipes and making good including repointing replastering and finishing according to existing finish where required. a) 11.43 cm thickness of walls 28.23
: - b) 22.86 cm thickness of walls
6 : - Bailing out water from the trenches for making new connections in fully charged pipe lines including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. (a) Upto 200mm I/d 28.47
7 : - Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below: (a) Top layer: - Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4 mm with uniformity coefficient 2.0 to 3.0) from Ghaggar or other approved source 28.50 (a)
: - (b) Second layer :- coursed sand screened, cleaned and washed and graded from 3 mm to 6 mm (from Ghaggar or approved equivalent quarry)
: - (c) Third layer: - Bajri screened washed and graded from 6 mm to 20 mm (from Ghaggar or approved equivalent quarry)
: - (d) Fourth layer: - Bajri (coarsed) screened and washed graded from 20 mm to 25 mm (from Ghaggar or approved equivalent quarry)
: - (e) Bottom layer:- Broken stone, screened, washed and graded from 50 mm to 75 mm (from Ghaggar or approved equivalent quarry)
8 : - Providing and fixing Steel bar embedded plastic steps of size 263 mm x 165 mm of orange colour, conforming to specifications, in pump chambers, manholes etc. having minimum 3 mm thick Polypropylene polymer confirming to IS : 10910 encapsulated on 12 mm dia ribbed steel bars per IS : 1786 29.28
9 : - Constructing brick masonry inspection chamber sizes as given below upto 0.60 meters average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement RCC 1:2:4 slab 100mm thick/C.C. topping 50mm thick with 455 mm x 455 mm / 455 mm x 610mm inside light duty C.I inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. a) Size 450mm x450mm inside (with 455mmx455mm cover and frame light duty single seal weighing 20 kg with C.C topping 29.84
: - b) Size 450mm x600mm inside (with 455mmx610 mm cover and frame single seal pattern 1 weighing 38 kg with C.C topping
: - C) Size 600mm x900mm inside (with 455mmx455mm cover and frame light duty single seal weighing 20 kg with C.C topping RCC slab
10 : - Providing, lowering, laying, cutting (cut surface to be uniformity finished) jointing with rubber rings marked with IS:5382 and testing of SPIGOT AND SOCKETTED RCC NP3 MARKED WITH IS:458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction to the Engineer -in-charge a) 200 mm i/dia RCC NP3 37 29.93
11 : - Providing and fixing SFRC manhole covers and frames markd with IS: 12592 including setting the same to correct lines and levels in 1:2 cement sand mortar over manhole including carriage loading, unloading stacking, handling, re-handling etc. complete in all respect to the satisfaction of engineer-in-charge. Type: Extra heavy duty set (MD-10) 560 mm clear opening. 29.94
12 : - Providing and laying SW pipe grade –A in standard length of 600 mm each pipe marked with IS :651 and their lowering, cutting , jointing & testing as described in HSR item No. 29.38 to 29.40 including the cost of jointing material as well as carriage, loading, unloading , stacking., handling, rehandling etc. complete in all respect to the satisfaction to the Engineer-in-Charge ii) 100 mm i/d 29.95
: - ii) 150 mm i/d
13 : - Providing and fixing in position best Indian make (to the approval of the Engineer-in-charge). Indian type orissa or orya water water closet suite for sinking into floor, with raised foot treads complete with 100 mm HCI 'P' trap with or without vent as required and all other necessary fitting as fully described in item no. 30.1. a) Size 580mm (i) White. 30.2
14 : - Providing and fixing in position best Indian make European type water closet suite with concealed 'P or 'S trap with or without vent (as approved by the Engineer-in-charge) and all other necessary fitting as fully described in item no. 30.3 above. (i) white 30.6
15 : - Providing and fixing 15 liters capacity low level vitreous china ware cistern complete with flush bend all other necessary fitting instead of C.I high level cistern complete with fitting. (i) white 30.12
16 : - Providing and fixing best indian make plastic hygenic seat with lid complete instead of hollow black or white plastic seat and lid (HSR 30.13) (i) white plastic seat (solid) 30.13
17 : - Extra for providing and fixing 32 mm dia. G.I/C.P flush pipe complete with accessories. Instead of 32 mm dia galvnised telescopic flush pipe with clips (as required by the Engineer-in-charge) (a) 32 mm G.I flush pipe 30.15
18 : - Providing and fixing in position best indian make a range of two squatting urinals in vitreous chinaware with one no. 5 litres capacity G.I. automatic flushing cistern with fittings and flush pipe 30.34
19 : - Providing and fixing in position best indian make (ordinary) lavatory suites consisting of :- Lavatory in vitreous chinaware size as given below (to the approval of the Engineer-in-charge) including china plug for tap hole where necessary. White R.S or C.I brackets for building into wall including painting 32 mm C.P brass waste with C.P brass chain and rubber plug 15 mm C.P brass screw down pillar tap with jamnuts or couplings best design (as approved by the Engineer-in-charge) All fittings best Indian make and; to the approval of the Engineer-in-charge All brass work chromium plated and complete in all respects including cutting and making good the walls floors and painting of fitting etc. 550mmx400mm with one no. tap 30.41
20 : - Providing & fixing in position best Indian make white lavatory suites (with full anti splash rim in vitreous chinaware and all other necessary fittings as fully described in item no. 30.41 above 30.42
21 : - Providing and fixing in position 32mm dia G.I waste pipe embedded in wall or lead waste pipe (weighing 3.47 kg. per metre and 2.8 mm thick) upto floor level including cost of wipped solder joint etc. complete (as required by the Engineer-in-charge) 30.48
22 : - Providing and fixing in position best quality stainless steel sinks with complete fittings as fully described in utem no 30.51 above a) 600 mm x 450 mm x 200 mm 30.53
23 : - Providing & fixing in position best indian make shower with 15 or 20 I/d in-let 125 mm diameter rose showers 30.66
24 : - Providing and fixing in position best indian make towel rails fixed in with rawlslugs embedded in walls with C.P Brass screws, complete in all respect including cutting and making goods the walls etc. a) 25mm dia C.P brass adjustable. ii) 600mm long. 30.68
25 : - Providing and fixing in position glass shelf fixed in with rawl plugs with C.P brass screws complete including cutting and making good the walls etc. c) Vitreous chinaware shelf 560mm long i) white. 30.69
26 : - Providing and fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on asbestos sheet ground fixed in position by means of 4 nos. chromium plated brass screws and washers over rubber washers and rawl plug embeded in the wall or chromium plated brass clamps with C.P. brass screws (as required by the Engineer -in -charge) complete including cutting and making good the walls etc. a) Indian make (I) 600mmx450mm 30.71
27 : - Providing and fixing in position 15 mm I/d C.P. brass bib cocks of best quality (as required by the engineer I charge) (a) Bib cock long body 30.75
: - (c) Bib cock
28 : - Providing and fixing in position C.P brass stop cocks (as approved by the Engineer-in-Charge) a) 15mm stop cock i) Stop cock male and female end. 30.76
: - ii) Concealed stop cock with flange
29 : - Providing and fixing in position best indian make flexible tube connection b) C.P brass i) 15mmx300mm. 30.82
30 : - Providing and fixing in position H.C.I soil waste vent or antisyphonage pipes to I.S.I specification of E.L.C manufacture or of any other reputed firm including cutting and wastage etc. and cutting holes in walls, roofs or floor etc. and making good to its original condition but excluding cost of lead jointing 100mm internal diameter 30.84
: - 75mm internal diameter
31 : - Providing lead caulked joints to H.C.I pipes and specials conforming to I.S.I specification of E.L.C manufacture or any other reputed firm including cost of lead yarn, fuel and tools etc. 100mm internal diameter (1.13kg) 30.87
: - 75mm internal diameter (0.91kg)
32 : - Providing and fixing in position M.S or heavy flat iron clamps made out of M.S flat not less than 5 mm of the approved deign for fixing C.I soil waste vent or anti pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. For 100 mm internal diameter pipes 30.88
: - For 75 mm internal diameter pipes
33 : - Providing and fixing HCI floor traps ISI marked of the self cleaning design with C.P brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors etc. minimum depth of water should be 150 mm with a minimum seal of 50mm b) With 75mm I/d outlet. 30.89
34 : - Providing and fixing in position HCI 50 mm internal diameter outlet plain nahani trap ISI marked of the self cleaning design with CP brass hinged granting with frame weighting 6.80 kg each fixed complete as fully described in item no. 30.89 (a) with 75 mm i/d outlet plain Nahani trap 30.9
35 : - Providing and fixing in position H.C.I. special for soil, waste, vent or anti-syphonage pipes to I.S.I marked including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead jointing (a) 100mm i/d pipes (i) Heal rest bend 30.91
: - (xiii) Bend with door
: - (xxii) Collars
: - (xxiv) c) WC connection 300mm long
: - (b) 75mm (xiii) Bend with door
: - (xiv) Bend Plain
: - (xviii) Collars
36 : - cutting chase in brrick walls in cement or in floor for embedding G.I or HCI opipe lines and making good the same to its original condition Size 75mmx75mm 30.95 a)
: - size 150mmx150mm b)
37 : - Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150mm x 150mm cast iron cover weighing approximately 7.26kg and frame clear opening 300mmx300mm and outside size 330mmx330mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:8:16 in foundation, and cement concrete 1:2:4 in coping around C.I cover and frame etc. with three coats of black bitumastic superior paint of approved manufacture on all C.I work as per standard design, minimim depth of water should be 150mm with a minimum seal 50mm a) 100mm internal diameter S.W gully trap. 30.114
38 : - Providing and fixing HDPE water storage tanks of sintex, Diplast, O.K. supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing Iin position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction to the Engineer. 1000 Ltr. Cap. 30.119
39 : - DSR ITEMS Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. (DSR 18.10) 15mm I/d
40 : - Providing and fixing GI Union in GI pipe including cutting and threading the pipe and making long screws etc. complete (new work) (DSR 18.46). 15mm I/d
41 : - Providing and fxing gun metal gate valve with C.I. wheel of approved quality (Screwed end) (DSR 18.17) 15mm I/d
42 : - Providing & fixing PVC pipe (4kg/cm2) duly slotted IS-4985:1988 including cost of adhesive, carriage, loading, unloading etc. complete in all respects to the satisfaction engineer incharge. (NS) size : 160 mm od NS
Note: In case of any difference in the unit & nomenclature of any of the HSR items of Civil and PH depicted in this DNIT and that given in HSR, the unit and nomenclature given in HSR shall be applicable.
Shri Ganesh Construction Co.
MM ENVRO ENGINEERS
GOYAL INFRASTRUCTURE
Rohit Kumar Contractor
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .