Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L3₹35.8 L+₹20,938.02 (0.59%)Rejected-Finance | L3 | Rejected-Finance Not Reasonable | |
| 3 | L3₹38.0 L+₹2.4 L (6.83%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹38.5 L+₹2.9 L (8.26%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L4 | Rejected-Finance Not Reasonable | |
| 5 | L5₹39.7 L+₹4.1 L (11.6%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance Not Reasonable |
Tender Value
₹48.5 L
EMD Value
₹96,900
Closing Date
1 Sept 2023, 6:00 pmClosed
Sh Saurabh Gupta, EE
GE(W) Colaba, Mumbai
SPECIAL REPAIRS TO BUILDING NO P-02 (OTM ACCN) UNDER GE (W) COLABA, MUMBAI
2023_MES_612279_1
8793/E8
Open Tender
Civil Works
Item Rate
180 days
GE(W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(W) Colaba, Mumbai
₹96,900
Yes
6 Oct 2023
5 Aug 2023
4 Sept 2023
5 Aug 2023
1 Sept 2023
18 Aug 2023
Amount
S&F in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any height all as specified and directed.
Fixing only in repairs in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any height all as specified and directed.
M&L in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints second class hardwood wheather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps in any situation including scafoldings of any height all as specified and directed.
Fixing only in repairs in patches including cutting out old, piecing, heading joints second class hardwood wheather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps in any situation including scafoldings of any height all as specified and directed.
Dismantling Mangalore patteren or similar tiles in roofing including portions bedded in cement mortar all as specified and directed.
Dismantling roof battens of any description in any position all as specified and directed.
Dismantling timber scantlings in fillets, rails, posts, rafters purlins, etc. under 40 sq.cm in any position all as specified & directed
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. Make -JSW
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, eaves etc fixed with self tapping screws all as specified and directed.
S&F joist, channel, angle or tee section fixed indpendently, without connecting plates confirming to Fe 410 -W (Gde- E- 250) quality- A including welding, nuts and bolts all as specified and directed.
S&F in repairs of framed work such as grills, gratings with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, windows, balcony in ground floor, framed balusters, walk ways, railings, framework of watertanks and similar work conforming to FE 290 Gde -E-165 all as specified and directed.
M&L in repairs to replace old decayed timber ( including piecing, scarifying, etc of old and new timber if required) second class hard wood clean sawn in scantlings timber framed and fixed in any position and description including scafoldings of any height all as specified and directed.
Demolition of cement concrete in ground floor n.exc 15cm thickness (below or above ground level) and removing the demolished material and debris out side MD land all as specified and directed.
M&L 75 mm PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection, flooring/subbase including necessary shuttering all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, & brushing neat cement slurry with 3.0 kg of cement per sq mtr all as specified and directed.
M&L non skid ceramic digital coloured glossy finish ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm in floors etc. set and jointed in neat cement slurry laid over 15 mm thick screed bed in cement mortar 1:6 and pointed in white or coloured cement to match all as specified and directed.
M&L Non Skid digital coloured glossy finish ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over rendering 10 mm thick on fair faces of brick work in CM (1:4) all as specified and directed.
M&L machine cut kota stone slab flooring 20-25 mm thick laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish inluding Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes all as specified and directed.
All as per above Item No 18 above but in riser of steps, skirting, dado and pillar laid over cement screed and jointed over rendering 10 mm thick on fair faces of brick work in CM (1:4) all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed.
M&L Glazed ceramic tiles 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces (including designed borders ) such as skirting and dados set and jointed in neat cement slurry & pointed in coloured cement to match laid over rendering 10 mm thick on fair faces of brick work in CM (1:4) all as specified and directed. Note:- Rate of Designer border in vertical surface shall be deemed to be included into quoted rate.
M&L Anti skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site all as specified & directed.
M&L Granite (of any type and colour) 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid in floors/Jambs/WHB conters and all other similar works in approved design laid over 20 mm thick screed bed in cement mortar 1:4 all as specified and directed.
M&L in repair for GI powder coated frame work for seamless ceiling 600x600mm grid size comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre all as specified and directed.
M&L 7-8 mm thick designer exposed metal frame ceiling with calcium silicate board of siliceous and calcareous materials reinforced with cellulose fibre for fixing in 605 X 605 mm grids all as specified and directed. Note:- Frame work for ceiling shall be measured and paid separately.
Providing and applying average 12-15 mm thick plaster in two coats in cement mortar 1:6 for with readymix prepacked proportioned dry mix mortar, blended with PP fibers, waterproofing additives, on internal surfaces including taking down, transporting of material, mixing, curing all as specified and directed. Name of Manufacturer: M/s ACC accopalst/M/s Premier Floor to Roof Materials pvt. ltd/ M/s Ultratech Cement Ltd/M/s Sound buildcare pvt. Ltd/ or other approved equivalent make.
Providing and applying average 25mm thick plaster in two coats in cement mortar 1:4 for with ready mix prepacked proportioned dry mix mortar, blended with PP fibers, mixed with liquid water proofing compound on other than fair faces of brick wall or concrete surfaces additives, on external surfaces including taking down, transporting of material, mixing, curing as per direction of Engr-in-charge. Note :- Liquid water proofing compound will be measured and paid seperately as supply only Name of Manufacturer: M/s ACC accopalst/M/s Premier Floor to Roof Materials pvt. ltd / M/s Ultratech Cement Ltd/M/s Sound buildcare pvt. Ltd/ or other approved equivalent make.
Rebuilding the section of damaged RCC elements to its original size or as per consultants recommandations in thicknesses of 40-100 mm by providing and casting with micro concrete of grade M-40 and above including providing and fixing of water tight foam faced finish shuttering of minimun 18 mm thick with supporting framework,all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint differences if any to satisfaction of engg. incharge, curing etc. complete.(Rate including- cube test to be conducted for every 5 M.T. workdone.6 No's of sample required per test). Ensure the quality of water by testing water as per IS 456 and document the same. Ensure temperature at time of mixing should be between 25 to 40 degree celcius by electronic temperature gauge Name of Manufacturer: BASF/Fosroc/Sika or other approved all as specified and directed.
Providing and erecting at site self supported two legged B class tubular steel scaffolding to reach any place of work on external face as well as internal areas so as to reach elements of building, including proper leveling using base jacks, minimum 1 mtr wide working platform at every 2 mtr level, approaches, extension, stepped MS ladders, so as to reach all levels upto height of 45 mtr or as per site requirement, lifting tackle for men and materials, supporting stubs for scaffolding including anchoring on walls and restoring the same after removal, anchoring, etc. all complete including dismantling and taking away all materials including periodically cleaning of the fallen debris from net during progress of work and maintaining the same during the entire period of work.after completion of proposed work etc. all complete. (Measurement : Elevational area of scaffolding erected for every two legs).
M&L for old loose spalled concrete should be chiseled from roof ceiling with the help of scrapers chisele & hammer after that cleaning of rust from mild steel rod applying cement slurry spray 3.00 kg per sqm by paint brush over cleaned surface for 8-10mm thick ready mix plaster in for ceiling on brick wall or concrete surfaces including making groove of appropriate size and finished even & smooth without using extra cement including two coat of OBD over one coat interior primer coat all as specified and as directed.
M&L for filling cracks by cutting 'V' groove cracks of internal or external plaster of walls, ceilings/Chajjas all along the crack upto 10 mm and remove the loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat and for external application must be coated with paint including necessary scafolding of any height all as specifed and direcetd. Make : Use of Dr Fixit Crack 'X' shrinkfree paste compound/ Smartcare Texture Crack Filler / Build Core Compound / Fosroc Compound, as approved by GE
M&L for cleaning all loose laitance on the wall and concrete substrate and applying one coat of epoxy bonding agent of SBR latex on exposed concrete surface to ensure bond between old concrete & new concrete by brush application including scafolding at any height all as specified and directed. Make: Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd or Nerolac perma SBR latex
M&L plastering 20 mm thick avg Polymer modified mortar (ready mix pack) in two coat 15 mm base coat and 5 mm finishing coat with and including curing as per manufacturer's instruction complete all as specified and as directed. Make : Dr. Fixit RepairPro Polymer Mortar, Fosroc RENDEROC S2 structural grade polymer mortar, ShaliFix FRM Polymer Modified Fiber Reinforced Mortar of STP or equivalent as approved by GE
Cleaning existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and providing, applying two coats of alkaline rust converting primer confirming to ASTMB- 117, on the existing rebars and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, with time interval of 1hour between the coats all as specified and directed. Name of Manufacturer: BASF/Fosroc/Sika/ Dr Fixit
Providing and application full and unbroken coating of anticorrosive protective zinc rich epoxy coating on expose reinforcement in two coats with time interval of minimum 1 hours between each coat including mixing of both componants by weight as per mfg specifications, brush application, curing to form a anticorrosive protective coating with high mechanical strength to cementitious repair works, all as specified and directed. Name of Manufacturer: BASF/Fosroc/Sika/ Dr Fixit
Supply only integral waterproofing compound
M&L for treatment on new plaster Internal wall surfaces of any desciption, preperation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology all as specified and M&L for the following : :- (a) Applying not less than 1.5mm thick wall care putty in two coats (Total thickness in two coats shall not be less than 1.5mm) on wall surface and smoothening the surface with Mechanised sanding etc prepatory to paint as directed complete all as specified (b) applying two coat of acrylic emulsion distemper of approved tint over a coat of acrylic primer on prepared surface as (a) above by using Airless spray over complete all as specified Note: Contractor shall use mechanized sanding tools for complete removal and Surface preparation by Air spray machine Trucare-graco-ultramax-490-pc-pro or equivalent approved by GE.
Complete removal of existing treatment on Old Internal wall surfaces of any desciption , preperation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology , complete all as specified and M&L for the following : :- (a) Applying not less than 1.5mm thick wall care putty in two coats (Total thickness in two coats shall not be less than 1.5mm) on wall surface and smoothening the surface with Mechanised sanding etc prepatory to paint as directed complete all as specified (b) applying two coat of acrylic emulsion distemper of approved tint over a coat of acrylic primer on prepared surface as (a) above by using Airless spray over complete all as specified complete all as specified Note: Contractor shall use mechanized sanding tools for complete removal and Surface preparation by Air spray machine Trucare-graco-ultramax-490-pc-pro or equivalent approved by GE.
Providing & applying anti algal water-based Elastomeric exterior wall finish on newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area) & of paint by roller etc. complete. (Make- Dr Fixit Rain coat classic, Asian paints, Berger ) Note : Height of Bldg Up to fourth floor.
Providing & applying anti algal water-based Elastomeric exterior wall finish on old newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area) & of paint by roller etc. complete. (Make- Dr Fixit Rain coat classic, Asian paints, Berger ) Note : Height of Bldg Up to fourth floor.
M&L for preparation of new surface painted wood or wood based surfaces, of any description, not otherwise described laid over 10 cm width or girth and apply two coat of synthetic enamel paint over one coat of primer all as speciefied & directed. Make : Asian - Apcolite or Berger- Luxol
M&L for preparation of old painted wood or wood based surfaces, of any description, not otherwise described laid over 10 cm width or girth and apply one coat of synthetic enamel paint all as specified and directed. Make : Asian - Apcolite or Berger- Luxol) all as apecified and directed
M&L for two coats of synthetic enamel painting on new steel surfaces including preparation of surface and one coat of red oxide zinc chrome primer, on surfaces of any description, over 10cm in width or girth,not otherwise described all as specified and directed.
M&L two coats of synthetic enamel painting over a coat of red oxide primer including preperation of steel surface of any description nexc 10 cm width or girth all as specified and directed.
M&L for one coat of synthetic enamel painting on old steel surfaces including preparation of surface of any description, over 10cm in width or girth, not otherwise described all as specified and directed.
Taking down chowkhats or frames area exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame) all as specified and directed.
Taking down chowkhat with shutter area not exc 1.5 sqm each (without taking off shutters from the frames) all as specified and directed
Taking down shutters of any description exc. 1.00 Sqm n exc 2.00 Sqm all as spcified and directed.
Taking down shutters of any description area n exc. 1.00 Sqm all as spcified and directed.
Resecuring or easing & adjusting without taking down exc 1 sqm and n exc 2 sq. m each all as specified & directed
S&F 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 120 MM X 65 MM size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length all as specified and directed
S&F 35 mm thick 2nd class hard wood rail and style plain framed panelled shutters(any panel) with lock rail and panel of 9 mm thick B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated all as specified and directed.
S&F to shutter of 2nd class hard wood 35mm thick Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc(without sash bars) edges of framing plain, chamfered or rounded, fittted with cut and mitred beads for securing gauge,etc sizes of member of shutter as specified SSR part-I Section 8 clause 8.24 (a) all as specified and directed.
S&F factory made 35 mm thick flush shutter solid core construction with block board core & plywood face panels commercial type on both sides laminated incl 5mm thick teakwood leaping alround all as specified & directed.
S&F 2nd class HW Glazed and skeleton shutters for windows of 25 mm thickness, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) all as specified and directed.
S & F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat comprising of 62 mm x 32 mm size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum specification as per IS 15931: 2012 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast unserviceable fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed by Engr-in-Charge.Make:- M/s Navratan Specialty Chemical LLP (Gujrat)/ M/s Sintex Industries Ltd/ M/s Accucell/ M/s Dura Plast Extrusion
S & F factory made 28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size, modulus of elasticity 850 N/mm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof specification as per IS 15931: 2012 and fire retardant and ixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and as directed by Engr-in-Charge. Make: M/s Navratan Specialty Chemical LLP (Gujrat)/M/s Sintex Industries Ltd/M/s Accucell/M/s Dura Plast Extrusion.
S&F in repairs 4mm thick panel of any type, pattern and shape Aluminium Composite Panel (ACP), aluminium thickness of 0.5mm, Front side finish of aluminum roll coated with Plain / coloured / wooden texture PE / PVDF, Core material of Non-toxic polyethylene, Macromolecular lamination film, Rear side of Aluminum coated with primer and including frame work using of Fasteners, including concealed screws, nuts, bolts and other items required for connecting aluminium to aluminium / steel / wooden / ply board, Blind rivets all fixing anchors, brackets and similar attachments used in the erections, shall be of aluminium, non-magnetic stainless steel, zinc coated steel, for fixing in both internal / external wall cladding complete weather proofing sealant of a polyurethane elastic joint / structural silicone sealant / pre-formed gaskets to the Horizontal & Vertical Joints in the Aluminium cladding / facade as per manufacturer's instructions all as specified and directed. Note : 1. The unit rate quoted is deemed to be inclusive of all necessary fixing acceserries mentioned in the description of work and scaffolding works at any height for installation. 2. For payment purpose panels areas will be measured on one side only.
S&F sheet glass ordinary quality 3 mm thick area not exc 0.50 Sqm in each panes and glazing with oil putty all as specified and directed..
S&F in repairs sheet glass ordinary quality 3 mm thick area not exc 0.50 Sqm in each panes and glazing with oil putty, wooden beads all as specified and directed..
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed..
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed..
S&F in floor door stopper of aluminium alloy body and tongue, length of leg 140 mm, anodised, with hard drawn steel spring and fubber foot all as specified and directed..
S&F extruded aluminium alloy handles 150 mm, fabricated type, anodized all as specified and directed.
S&F extruded aluminium alloy barrel tower bolts with bright bolt and fixed of size 200 mm for doors all as specified and directed.
S&F aluminium anodised, barrel tower bolts of extruded section and fixed of 150 mm size all as specified and directed.
S&F butt hinges of size 100 mm, medium weight, stainless steel min 3 mm thick for doors of design all as directed by Engr-in-Charge
S&F in repairs Stainless Steel drapery road (1 mm thick stainless steel section outer dia 25 mm with bracket, ring & fancy side holders all as directed by Engr-in-Charge
Demolition of brick masonary built in cement mortar all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM (1:6) all as specified and directed.
Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal to store all as specified and directed.
S&F 15mm dia steel tubes, 'medium grade' galvanised, with all fitting and fixed complete including cutting chasing pinning and making good to walls and ceilings or laid in floors all as specified and directed.
Refixing old 15mm dia steel tubing and connections in new or old position (walls, ceiling, floors, all as specified and directed.
Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal to store all as specified and directed.
S&F 20mm dia steel tubes, 'medium grade' galvanised, with all fitting and fixed complete including cutting chasing pinning and making good to walls and ceilings or laid in floors all as specified and directed..
Refixing of old 20mm dia steel tubing and connections in new or old position (walls, ceiling, floors, etc.all as specified and directed.
Taking down rain water pipes (of any size or pattern), including all fittings, heads, shoes, bends, swan-necks, and removal to Store (measured overall as fixed along the centre line over fittings and accessories).
S & F in repairs 110 mm dia PVC (SWR) pipes, type B, single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls to pipe difference 100 mm including stack clamps out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays including all steel scaffloding arrangments complete all as specified and directed by Engr-in-charge.
S & F in repairs 75 mm dia PVC (SWR) pipes, type B, single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls to pipe difference 100 mm including stack clamps out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays including all steel scaffloding arrangments complete all as specified and directed by Engg-in-charge.
S&F 110mm dia PVC (SWR) bends any radius all as specified and directed.
S&F 75 mm dia PVC (SWR) bends any radius all as specified and directed.
S&F 110 mm PVC (SWR) junction single, (Single T) equal or unequal all as specified and directed.
S&F 75 mm PVC (SWR) junction single, (Single T) equal or unequal all as specified and directed.
S&F 110 mm PVC (SWR) junction single, (Single Y) equal or unequal all as specified and directed.
S&F 75 mm PVC (SWR) junction single, (Single T) equal or unequal all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and directed..
S&F PVC (SWR) floor trap 75 mm, plain with CP grating including joining and solvent cement all as specified and directed.
S&F in repairs tubular towel rail brass chromium plated , 20mm dia, 60cm long between flanges all as specified and directed. Make : Jaquar, Marc, Kohler, Cera
S&F in repairs 15 mm dia brass CP fancy wall mixer with L Bend (including provision of O/H shower & hand shower) for mixing hot & cold water screwed down for iron pipe and fixed as in repairs with hand shower HSH-1717 and tube all as specified and directed.
S&F in repairs 15 mm dia brass CP centre hole basin mixer for mixing hot & cold water screwed down for iron pipe and fixed as in repairs. Make Cat No QQT-7169B of Jaquar, Kohler,Marc
S&F in repairs 15 mm bore gun metal gate valve cast copper alloy, screwed down high pressure with wheel head, screwed both ends with crutch or butterfly handle for iron pipes all as specified and directed.
S&F in repair wash basins, vitreous china, white, flat back, of size 550mm x 400mm x 140mm or nearest size conforming to model 'CALBURT' Cat No. S2020137 of CERA or of equivalent model in other makes as listed in Appendix 'C, with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and table top basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete and sunken floor treatments including demoliton of cement concrete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:4) on fair faces of brickwork or concrete surfaces, with using liquid water proofing compound @ 200 ml per 50 kg bag of cement or as per manufracture's instructions, finished surfaces even and smooth without using extra cement all as specified and as directed. Note: WPC shall be measured and paid for seperately under relevant item.
M&L for under tile water proofing membrare in three layers and over screed bed floor and wall finishes all as specified and as directed by Engineer-in-charge. Make :Dr. Fixit Fastflex or equivalent as approved by Engineer-in-Charge.
S&F in repairs vitreous China squatting pan of Orissa pattern cat part No. CLOVIN S3010110 of CERA or of equivalent model in makes as specified with P or S trap of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe including lime concrete bedding and connection to antisyphonage pipe etc including making good to floor all as specified and directed.
S&F in repairs Vitreous China half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader, pointing around urinal back in cement; flush pipe, grating and Union for discharge pipe all as specified and directed. Make Jaquar, Kohler, Hindware.
S&F 50 mm dia low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm fixed complete to walls, ceiling or in floors including cutting, chasing, pinning and making floor good with existing one all as specified and directed.
S&F in repairs PVC valve less syphonic action type flushing cistern low level white, dual flush, ISI marked (IS: 7231) with PVC inlet ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC long bend for squatt pattern etc, set with concrete and making good to floor including taking down existing complete all as specified & directed.
S&F in repairs Soap dish complete all as specified & directed . Make Cat No AQN-7731 of Jaquar, Kohler/Marc.
S&F in repair 15mm bore, chromium plated bib taps cast copper alloy with crutch or butterfly handle screwed down for iron pipe all as specified & directed. Make Cat No QQT-7037 of Jaquar, Kohler/ Marc
S&F in repairs fancy type chromium plated 15 mm bore stop valve/angle cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed.
S&F in repairs Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union alongwith arm 225mm and flange all as specified and directed..
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling all as specified and directed.
Taking down carefully copper/aluminum submain wiring complete including all fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces all as specified and directed
M&L point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volts grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, casing caping with accessories and incuding provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches, socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light fan point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately . Make: Havells/ Polycab/ Finolex.
All all as per Srl item No.109 here in before but for socket outlet point 5 Amp on the same board.
All as per Srl item No.109 here in before but for socket outlet point 5 Amp on Independent board.
All as per serial item No 109 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) all as specified and directed. Note: Earthing wire should be of 4 Sqmm
S&F switch piano (ISI marked) Single pole 240 volts, 5 Amps all as specified and directed. Make- Havells/anchor/ Legrand.
S&F socket (ISI marked) 2/3 pin and 5 Amps, flush type, 240 volts all as specified and as directed. Make- Havells/anchor/ Legrand.
S&F switch socket combination (ISI marked) 2/3 pin and 5/15 Amps, flush type, 240 volts all as specified and directed. Make- Havells/anchor/ Legrand.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet all as specified and directed. Make- Havells/anchor/ Legrand.
S&F ceiling rose surface bakelite 65x50mm, 3 terminal all as specified and directed. Make : Cona , Plaza, Anchor .
S&F in repair Modular type AC Box, 4 Module with Socket and 20 Amp SP mini MCB in plastic box enclosure along with cover plate and top all as specified and directed. Make : Anchor Model No : 98498 or equivalent model in Havells/ Legrand.
S & F LED light fitting 1x9W/1X10W luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make Bajaj IVORA BULKHED or equivalent make of /Havell's/Wipro.
S&F in repairs 20 watt LED, 6500 K, 4 feet long fixed including on pvc square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing all as specified and directed Make:- Wipro, Model No : Wipro Garnet 20W LED Emergency Batten or in equivalent model in Havells / Philips/ Wipro.
S&F recesss mounted low glare luminaire 40 watt 2 X 2 with all accessories all as specified and directed. Make:- Wipro Backlid 6500K or equivalent make of Havells/ Philips/ Bajaj.
S&F Exhaust fan 230 volts, 225mm, metal body, heavy duty with wooden frame including making all electric connection all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall all as specified and directed. Make Bajaj Bajaj Freshee 225 mm Metallic Grey Exhaust Fan or equivalent make of Havells/ Crompton Greaves.
M&L refixing of ceiling fan (old fan) and connecting up including provision of cable from ceiling rose or connector and fan painting of ceiling fans in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust with taking down fan, sealing cable end, dismantling romoving and hanging fan with rod of required length and proper hook and blades and removing fan and blades to store all as specified and directed. Note: Connection should be made neatly using two core flexible cable.
S&F in repairs LED security Building light LED 35 Watt, pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light all as specified and directed. Make:- Bajaj Cat part No- 169821 LED/CG as perr vat No LSTO 25 CDL equivalent model as in Surya / havells .
S&F in repairs MCB Distribution board, 240 volts single pole and neutral, single door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down all as specified and directed. Make: Legrand/ Indo Asian
S&F in repairs MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series all as specified and directed.
S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's all as specified and directed.
S&F in repairs MCCB DB TPN 8 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, single door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and directed. Note : MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable .
S&F in repairs MCCB TPN, 240 Volts, 63 to 100 Amps, 10 kA rupturing capacity 415 Volts complete all as specified and directed
M&L in repairs for Sub main wiring with two run of 6 sq mm stranded copper conductor PVC unseathed FRLSH wire along with 6 sq mm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 32 mm dia) for housing the wires for from Pannel / Main DB to house SPN DB including taking down old Unsv submain with all associated fixtures all as specified & as directed by engr-in-charge Make : Finecab / Havells / Finolex as approved by GE Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 6 sqmm cable and one run of 6 sqmm cable with PVC conduit shall be measured as one length.
M&L in repairs Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia conduit ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
M&L earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing on completion all as shown in Electrical Plate No 3 of SSR part -I.
Bright Construction Co
ASHOK CONSTRUCTION
Unitech Enterprises
SHREE JAGDISH FURNITURE CO.
RAJU AND COMPANY
Bidder Name
Unitech Enterprises
ORIENT ELECTRIC CO
ASHOK CONSTRUCTION
Bright Construction Co
SHREE JAGDISH FURNITURE CO.
RAJU AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .