Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC AT SCHOOL BAZAR PO MIDNAPORE PASCHIM MEDINIPUR 721101 | MIDNAPORE | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹6.9 L+₹19,797.75 (2.93%)Rejected-Finance VILL GOPINATHPUR P O NAKOLE P S SHYAMPUR DIST HOWRAH | HOWRAH | HOWRAH | WEST BENGAL | L2 | Rejected-Finance Bid is not L1 | |
| 3 | L4₹7.4 L+₹62,000.75 (9.19%)Rejected-Finance AT G 2 BIDHAN NAGAR PO MEDINIPUR PS KOTWALI PASCHIM MEDINIPUR 721101 | MEDINIPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L4 | Rejected-Finance Bid is not L1 | |
| 4 | L4₹7.6 L+₹86,640.67 (12.8%)Rejected-Finance 133 GARFA MAIN ROAD KASBA KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L4 | Rejected-Finance Bid is not L1 | |
| 5 | L5₹7.7 L+₹94,015.75 (13.9%)Rejected-Finance 35 DHARSA MAHITAL KHAN S BYE LANE JIGACHA MUKHERJEE PARA HOWRAH PIN 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | L5 | Rejected-Finance Bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹15,928
Closing Date
28 Dec 2020, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Jhargram Electrical Div.,PWDte
OFFICE OF THE EXECUTIVE ENGINEER JHARGRAM ELECTRICAL DIVISION, P.W.Dte. Jamboni More, Dist. Jhargram, Pin- 721507
EI and renovation work including the panel board shifting at ICV Polytechnic, Jhargram
2020_WBPWD_309373_1
WBPWD/EE/JED/eNIQ23/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
22 days
JHARGRAM
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,928
8 Jul 2021
17 Dec 2020
30 Dec 2020
21 Dec 2020
28 Dec 2020
21 Dec 2020
120 days
Amount
Shifting of existing LT Panel (two part type) of size approx 10ftx3ftx6.5ft from its existing temporary position to newly constructed meter room complete construction of Meter room 10 mtr approximate distance, by manual / hydra labour after necessary shut down & disconnection from electric Power & opening of existing every line from the terminal of LT Panel & by providing sufficient skilled man power and necessary dismantling in parts after removing nut bolts tools etc. & tackles as per necessary rope & GI/ MS pipe etc. & dismantling of brick wall (10ftx1.5ft10inch) & welding ring at collapsible gate for necessary removing the panel & opening of existing Collapsible gate (10ft*8ft) etc. with necessary care of existing cable & placement it to new panel room & Reinstalled the existing collapsible gate as per direction of EIC.
Making Brick wall of size 10ftx1.5ftx10inch by Brick & plaster with neatly cement finish including supply of bricks sand cement etc.
Supplying and laying of various Nos. of cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supplying and laying of cable upto 4 core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Withdrawing and relaying of various Nos. of cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Withdrawing and relaying of various Nos. cable upto 150 sqmm through existing opened masonry trench incl. taking out RC covers, setting them in order, including drilling on wall for cable entry and mending good the damages with cementing, plastering etc. filling the trench with fine dry sand incl. supplying sand
Supplying and fixing 20mm thick hylam sheet/bakelite sheet of size 500 x 400 mm with 3 nos. 400A capacity porcelain kit-kat fuse with neutral link, fixing on wall with necessary arrangement like fastner, nut bolt etc at sub-station room.
Supply & installtion of 50x50x5 mm ( 3.8 kg/ mtr) MS steel equal angle with both side necessary cutting chmfering at both side @ length 1.5 mtr each piece including gruting both end over trench including maending good damages.
Supply & fabricated and installation of steel Checker plate of 8 mm thickness ( 63 kg/ sqmtr) for necessary covering of Trench present at Meter room after necessary cutting grinding etc. as per requirement at site with both side of plate [providing of holding hook.
Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. Two coat of synthatic anamel paint one after another on one coat of RO primer.
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the round level and partly above ground level to an average depth of 3.65 Mts ( ISI- Medium)
Excavation of soil for installation of Earth Electrode and filling & ramming ( For Morrum Soil) [ including cabl;e repairing soil digging)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supply & delivered of 1.1 kv 4 core 400 sqmm AL/ A cable ( PWD approved make) [ Meter loop]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
for 2 core 10 sqmm
for 4 core 50 sqmm
for 4 core 70 sqmm
for 4 core 95 sqmm
for 4 core 120 sqmm
for 4 core 150 sqmm
For 4 core 400 sqmm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.
for 2 core 10 sqmm
for 4 core 50sqmm
for 4 core 70 sqmm
for 4 core 95 sqmm
for 4 core 120 sqmm
for 4 core 150 sqmm
For 4 core 400 sqmm
Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials(Brand approved by EIC) for 4 core 50 sqmm AL/A underground cable. ( western hostel)
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
40 mm dia
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. ( Make ; L&T)
63 Amp capacity ( for source at Electric lab DC rectifier unit)
125 Amp capacity ( for new cable at Ladies hostel)
320 Amp capacity ( Existing meter room)
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl.
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
25 mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the and by the prelaid GI fish wire and making necy. connection as required
4x126/0.4 ( 16 sqmm ) + 2x84/0.4 ( 10 Sqmm ) as ECC
2x 396/0.4 (50 sqmm) (For DC)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
Flexible PVC multi core cable 1.1 KV 4 core 2.5 sqmm anneled copper
Flexible PVC multi core cable 1.1 KV 4 core 4sqmm anneled copper
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] ( AV RUN =12 MTR)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] ( AV RUN =10 MTR)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing ttachment, painting and mending good damages to building works ( on board)
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & nsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supply & delivery of Split type Room Air Conditioner fitted with rotary compressorhaving following major specification , Refrigerent R-32/R410 A, Rated cooling capacity min( Watt) 6400 , Minimum room discharge air flow 636 CFM , Rated power input maximum 1850 w,ISEER star rating 2 star, minimum tonnage required 2.2 TR/ 2 TR with other modern features ( With installation kit) make, DAIKIN ( FTQ60 TV 16U2/ Hitachi ( RMH1222HBDW)
Supply & laying 1/2 " & 1/ 4 "copper refrigerent pipe with 9 mm thick nitrile rubber insulation , aerotape covering , aluminium foil wrapping , 4 core 2.5 sqmm pvc FR cupper cable incl. fixing arrangement &b wrapping insulation tape on wall by GI/ PVC shaddling complete with all respect for 1.8/2.0 TRAC Machine ( as per choice and direction of EIC)
Installation of split type Room Air conditioner outdoor unit by fixing out door unit on pre fabricated sheet steel ODU stand an ISO 9001-2015 company with fastner arrangement on wall & nut bolt with this structure with necessary installation of indoor unit as per it's process & acessories on inner wall . with water outlet pipe
Supply & installation of outdoor type light fittings on after dismantling of existing damaged one of HPSV Fittings. ( Crompton make: LFL-60- CDL / equivallent wattage of havells/ Bajaj make )
Supplying and Fixing GI water proof looping cable box size(200mm x 150mm x 100mm) having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting .
Supply & installation of indoor commercial lighting on existing vacant point after down rod with suitable fixing arrangement for fittings. : ( Crompton make LCCLB 24-CDL/ equivallent wattage of Havells/ bajaj make)
Supply & installation of outdoor type street light fittings on after dismantling of existing damaged one. ( Crompton make: LSTS-30- CDL / equivallent wattage of havells/ Bajaj make )
finishing of the PVC insulated wire ends by sckoting with pin/ring type copper schoket and insulated tape etc. including supplying schoket tapes 2.5sqmm
finishing of the PVC insulated wire ends by sckoting with pin/ring type copper schoket and insulated tape etc. including supplying schoket tapes 4sqmm
painting of steel tubuler pole of length upto 9 mtr 2 coat of alluminium paint over 1 coat of RO primar of approved made and brand including preparation of surface by sand paper or emry paper, cleaning etc. for receving fresh coat of paint.
Netaji Engineers CO-Operative Society Ltd.
M/S JOGMAYA ENTERPRISE
Prava Enterprise
CHAKRABORTY ELECTRIC
stage.html
html • 0.05 MB
technical_581253.pdf
PDF • 0.26 MB
techsummary_581253.pdf
PDF • 0.14 MB
finance_581253.pdf
PDF • 0.26 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_581253.pdf
PDF • 0.14 MB
WorkOrder.pdf
PDF • 0.50 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .