Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC CHOLADHARA JORAHAT 785001 ASSAM | JORHAT | ASSAM | 785001 | ₹30.7 L Quoted ₹31.3 L | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER |
| 2 | L2₹33.5 L+₹2.2 L (7.05%)Rejected-Finance 2ND 6 KEDIA HOUSE MA ROAD BYELANE 1 REHABARI GUWAHATI ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | ₹33.5 L+₹2.2 L (7.05%) | L2 | Rejected-Finance BEING L2 BIDDER |
Tender Value
₹31.2 L
EMD Value
₹62,400
Closing Date
3 May 2022, 6:00 pmClosed
GE RANGIA
GE Rangia C/O 99 APO Rangia
CONVERSION OF ACSR OVER HEAD CONDUCTOR TO LT UNDERGROUND CABLE AND ALLIED INFRASTRUCTURE AT HATTIGOR AND OTHER SANCTION WORKS AT HATTIGOR AND CHANGSARI MILITARY STATION UNDER GE RANGIA
2022_MES_511376_2
8542/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
HATTIGOR AND CHANGSARI
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE RANGIA
₹62,400
Yes
21 May 2022
4 Apr 2022
5 May 2022
4 Apr 2022
3 May 2022
21 Apr 2022
Amount
Dismantling of cross arms/clamp/nuts/bolts fixed on Steel tubular poles carefully and removing unserviceable cross arms from site complete all as specified and as directed by Engr-in charge.
Dismantling of LT insulators of any type and size removing the insulator form site complete all as specified and as directed by Engr-in charge.
Dismantling of stay assembly complete all as specified and as directed by Engineer-in-charge.
Dismantling of existing LT over head ACSR conductor of any size removing conductor for site complete all as specified and as directed by Engr-in charge.
Dismantling the existing service connections of any size complete all as specified and as directed by Engr-in charge.
Supply, laying & testing of 185 Sqmm, 3.5 Core XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100Volt grade laying in trenches with fixing acessories complete all as specified and as directed by Engineer-in-charge. Note - Earthwork, sand cushioning, bricks, GI pipe, etc. shall be measured and paid separately.
All as per serial item No. 6 above but size of 120 Sqmm, 3.5 Core.
All as per serial item No. 6 above but size of 95 Sqmm, 3.5 Core.
All as per serial item No. 6 above but size of 70 Sqmm, 3.5 Core.
All as per serial item No. 6 above but size of 50 Sqmm, 3.5 Core.
All as per serial item No. 6 above but size of 35 Sqmm, 3.5 Core.
All as per serial item No. 6 above but size of 25 Sqmm, 3.5 Core.
All as per serial item No. 6 above but size of 16 Sqmm, 4 Core.
All as per serial item No. 6 above but size of 10 Sqmm, 2 Core.
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated materials (soils) not exc. 50.00 m and deposited where directed at a level not exc. 1.50 M above the starting point in soil, complete all as specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft/loose soil, complete all as specified and as directed by Engineer-in-charge.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge. Note - Only punned thickness shall be measured and paid.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
M&L for GI pipe light grade 50 mm dia fixed to pole with MS clamps of size 40x5 mm nut & bolts or laid in trenches, complete all as specified and as directed by Engineer-in-charge.
S&F GI pipe 100 mm bore light grade for protection of UG cable complete all as specified and as directed by Engineer-in-charge.
S&F PVC insulated FR round sheathed, electric cable with copper conductor, 1100 volts grade having cross-sectional area 1.5 Sqmm 3 Core complete all as specified and as directed by Engineer-in-charge.
M&L of SMC juction box of size 250x200x100 mm fir street light fitting suitable for 4 core cable, 3P+n incoming/outgoing including 01 nos MCB SP 10Amp, suitable size cable glands, MS clamps and all other fixing accessories etc, complete all as specified and as directed by Engineer-in-charge.
Supply, install, testing & commissioning of CPRI approved LT panel, outdoor type, plateform mounted, totally enclosed, weather dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA Sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6 mm angle iron frame work having front and rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, suitable size/capacity CT's on outgoing MCCB, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts, springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection should be provided with copper cable of suitable size and necessary grouting/foundation all as requried at site and comprising following items: (a) BUS BAR- Aluminium bus bar system of capacity 400 Amp four pole duly colour coded. (b) MCCB, 4 pole of capacity 200 Amps with breaking capacity of 25KA - 02 No. (c) MCCB, 4 pole of capacity 160 Amps with breaking capacity of 25KA - 02 No. (d) MCCB, 4 pole of capacity 125 Amps with breaking capacity of 16KA - 02 No. (e) MCB, TPN of capacity 63 Amps with breaking capacity of 10KA - 01 No. (f) VAF meter- 01 No (g) Phase indicator lamp RYB with LED type - 01 set of three, (h) MCCB 4 pole of capacity 320 Amp with breaking capacity 36 KA-01 NO (incoming) complete all as specified and as directed by Engineer-in-charge.
Supply, install, testing & commissioning of CPRI approved LT panel, outdoor type, plateform mounted, totally enclosed, weather dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA Sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6 mm angle iron frame work having front and rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, suitable size/capacity CT's on outgoing MCCB, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts, springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection should be provided with copper cable of suitable size and necessary grouting/foundation all as requried at site and comprising following items: (a) BUS BAR- Aluminium bus bar system of capacity 400 Amp four pole duly colour coded. (b) MCCB, 4 pole of capacity 250 Amps with breaking capacity of 25KA - 01 No (incoming). (c) MCCB, 4 pole of capacity 160 Amps with breaking capacity of 25KA - 01 No (outgoing). (d) MCCB, 4 pole of capacity 125 Amps with breaking capacity of 16KA - 02 No (one spare). (e) MCB, TPN of capacity 63 Amps with breaking capacity of 10KA - 01 No. (f) VAF meter- 01 No. (g) Phase indicator lamp RYB with LED type - 01 set of three, complete all as specified and as directed by Engineer-in-charge.
Supply, install, testing & commissioning of CPRI approved LT panel, outdoor type, plateform mounted, totally enclosed, weather dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA Sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6 mm angle iron frame work having front and rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, suitable size/capacity CT's on outgoing MCCB, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts, springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection should be provided with copper cable of suitable size and necessary grouting/foundation all as requried at site and comprising following items: (a) BUS BAR- Aluminium bus bar system of capacity 200 Amp four pole duly colour coded. (b) MCCB, 4 pole of capacity 32 Amps with breaking capacity of 16KA - 01 No (incoming) (c) MCB, TPN of capacity 32 Amps with breaking capacity of 10KA - 01 No (outgoing) (d) MCB, SPN of capacity 40 Amps with breaking capacity of 10KA - 03 No. (e) MCB, SPN of capacity 32 Amps with breaking capacity of 10KA - 03 No. (f) MCB, SP of capacity 25 Amps with breaking capacity of 10KA - 03 No (g) VAF meter- 01 No. (h) Phase indicator lamp RYB with LED type - 01 set of three, complete all as specified and as directed by Engineer-in-charge.
Supply, install, testing & commissioning of CPRI approved LT panel, outdoor type, plateform mounted, totally enclosed, weather dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA Sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6 mm angle iron frame work having front and rear hinged doors, lifting lugs (2 Nos), provision for earth strip connection, suitable size/capacity CT's on outgoing MCCB, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts, springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer. The internal connection should be provided with copper cable of suitable size and necessary grouting/foundation all as requried at site and comprising following items: (a) BUS BAR- Aluminium bus bar system of capacity 400 Amp four pole duly colour coded. (b) MCCB, 4 pole of capacity 160 Amps with breaking capacity of 25KA - 01 No (incoming). (c) MCCB, 4 pole of capacity 125 Amps with breaking capacity of 16KA - 01 No (outgoing) (one spare). (d) MCCB, 4 pole of capacity 63 Amps with breaking capacity of 16KA - 04 No (one spare). (e) MCB, TPN of capacity 63 Amps with breaking capacity of 10KA - 01 No. (f) VAF meter- 01 No. (g) Phase indicator lamp RYB with LED type - 01 set of three, complete all as specified and as directed by Engineer-in-charge.
Supply and installation, testing & commissioning of hi wall split units (split type AC) indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality of capacity 1.5 TON, 3 star rated and EER 3.2 of capacity as shown, complete all as specified and as directed by Engr-in charge.
Supply and fix wall mounted voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA , complete all as specified and as directed by Engineer-in-charge.
Supply and fix 16 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-charge.
Supply and fix 10 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 4 way DB Double door with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 2 way DB with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral in the MCB DB complete with connection testing and commissioning. complete all as specified and as directed by Engr-in charge.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP to 63 AMP, in the MCB DB Complete with connection testing and commissioning. complete all as specified and as directed by Engr-in charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses etc with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for for one 3 pin socket outlet 5 AMPs on independent board, complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item no. 36 above but with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour for 15 A socket outlet on independent boards.
Supply and fix Switch socket combination 2 in 1, 6A flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 6A/16A, 5 in 1 flush type with fuse & neon incator, complete all as specified and as directed by Engineer-in-charge.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed by Engr-in charge.
Supply and installation, testing & commissioning of window type AC 5 star rating electric driven (single phase) with cooling capacity 4500 k cal (1.5 Ton), 5 star rated, having cooper condenser, complete all as specified and as directed by Engr-in charge.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 130 V to 300 V having 4-6 second initial delay with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA , complete all as specified and as directed by Engineer-in-charge.
S&F Wiring for circuit/submain wiring alongwith earth wire with the sizes 2x6.0 sq. mm +1x6.0 sq. mm earth wire of FR is PVC insulated copper conductor in PVC casing caping, single core cable in surface/recessed as required complete all as specified and as directed by Engr-in charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, hermostate, NRV, connection piece etc., complete all as specified and as directed by Engineer-in-charge.
Supply and fix stop valves 15 mm, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, swrewed both ends for iron or for unions and fixed complete all as specified and as directed by Engineer-in-charge.
S&F 15 mm bore bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
S&F GI tube 15 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge.
S&F for fastner/fittings including driling of hole in wall and make good disturbed surfaces match with existing wall and fixing of geyser in suitable position, complete all as specified and as directed by Engr-in charge.
Supply and fix MCB SPN 240 Volts 6-32 Amp 'C' series breaking capacity 10 KA rating, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SP 240 Volts 6-32 Amp 'C' series breaking capacity 10 KA rating, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
Supply only Submersible pump set, electic driven 415 V, three phase, suitable for 200/250 mm dia bore well (casing pipe size 200/250 mm) of Cap 20 HP, 15 KW, 12 stage, outlet size 80 mm, head 66-108 Mtr, discharge 550-870 LPM, complete all as specified and as directed by Engineer-in-charge. NOTES :- 1. The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
ADITI CONSTRUCTION CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .