| 1 | L1₹40.0 LAccepted-AOC MAHALSA ROAD BINAGA KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L1 | Accepted-AOC RATES QUOTED ARE REASONABLE | |
| 2 | L2₹4.2 L−₹35.8 L (89.4%)Rejected-Finance | L2 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 3 | L3₹43.9 L+₹3.9 L (9.66%)Rejected-Finance | L3 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 4 | L4₹45.3 L+₹5.3 L (13.3%)Rejected-Finance | L4 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 |
Tender Value
₹49.5 L
EMD Value
₹98,900
Closing Date
12 Dec 2022, 6:00 pmClosed
GARRISON ENGINEER SEA BIRD KARWAR
GARRISON ENGINEER SEA BIRD KARWAR
ADDITION /ALTERATION AND SPECIAL REPAIRS TO RICE STORE BUILDING NO. P-29 AT BVY (KAR) AND PROVISION OF SEVEN IN NUMBER AIR CONDITIONERS OF 1.5 TON EACH WITH ASSOCIATED WORKS IN VARIOUS CLINICAL LOCATIONS,FALSE CEILING IN CONFERENCE ROOM AND MS IRON
2022_MES_528537_6
8876/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
KARWAR
AS PER NIT
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER SEA BIRD KARWAR
₹98,900
Yes
20 Jan 2023
26 Nov 2022
14 Dec 2022
26 Nov 2022
12 Dec 2022
30 Nov 2022
26 Nov 2022 - 28 Nov 2022
Amount
Removing existing water proofing treatment of any description from roof slabs, cleaning the surface using wire brushes etc, roughening the concrete surfaces picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.00 kg of cement per Sqm (Where PCC padding is to be provided) complete all as specified.
M & L PCC (1:2:4) type B-0, 25 mm thick (using 12.5 mm graded crushed stone aggregate) as in roof paddding, complete all as specified and as directed.
M & L for renderenring 15mm thick using WPC on block masomary surfaces or concrete surfaces on roof top in CM 1:4 finished fair and smooth(without using extra cement) complete all as speified and directed.
Supply only water proofing compound complete all as specified and directed
M & L for water proofing treatment by applying oil bound bitumen primer, having a density of 0.87 - 0.89 Kg/lit, at the rate of 0.40 ltr/Sqm, providing and laying 4 mm thick APP modified water proofing membrane weighting not less than 4 Kg/Sqm of approved make including minimum 10 cm side lap and 15cm end lap, laid and pasted with blue flame torching applications and finally finishing with solar reflective bituminous aluminium paint at the rate of 0.1Kg/Sqm complete all as specified and directed.
M & L repair of cracks by Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M &L for applying two coats of water proofing coating system by applying shalicryl-215 of STP Ltd/Rain coat 601 of DR fixit /Barrier coat of Araldite over a coat of respective primer including preparation of plaster surface by complete removal of existing treatment including filling of crack with respective crack filler all as per manufacturers instructions complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M & L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified.
M & L for preparing newly plastered surfaces of wall and applying two coats of Acrylic washable distemper over a coat of alkaline resistance primer complete all as specified and directed
M&L preparing of old painted plastered surface of walls of any description including cornices and applying one coats of acrylic emulsion exterior grade, weather proof antifungal paint complete all as specified and directed.
M&L for preparation of old decorated wall surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and appling one coat of Acrylic washable distemper complete all as specified and as directed by Engr-in-Charge.
M & L preparing of old decorated plastered or un plastered surface of ceiling and applying one coats of white wash complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
S & F for powder coated aluminium frame for door, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire & average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings,heads,shoes,bends,swan-necks etc.
M & L 110 mm dia. PVC rain water pipes with Socket all as specified and directed.
M & L 110 mm dia. PVC rain water pipes bends all as specified and directed.
S & F in repairs Stack clamps out of 50mm by 5mm including bolts and nuts and securing ends of stay to wall or roof for 110mm pipe.
Demolition of stone slabs and tiles of any description and thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed
M&L for 40mm thick waterproof topping (by incorporating an approved mettalic floor hardener) laid on concrete floors and pavings.Metallic floor hardener and cement shall be throughly mixed to an even colour in dry state in the proportion recommended by the manufacturer.This mixture shall be mixed with crushed granite/basalt/trap as indicated (6mm and down) in the proportion 1:2 by volume.Requisite amount of water shall then be added to form a workable mixture and finished even and smooth complete all as specified and directed. Note ( Mettalic hardner shall be paid seperately )
Mettalic floor hardener of approved quality consisting of uniformally graded metal particles, free from non-ferrous metal particles,oil grease sand,soluble alkaline compounds for increasing abrasion resistance and shall be ironite,hardonate,ferronite or other equal and approved mettalic floor harderner complete all as specified and directed.
Supply and fix glass dividing strips of size 40mm X 3mm inserted in position and confirm to design complete all as specified and directed.
S & F for 10mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium of Size 600 x 600 mm complete all as specified and directed
S&F for andoised aluminium snap grid frame work for false ceiling Tee of size 24 x 28.5 mm made out of PGI sheet 0.3 mm thick double at web and single at flange, flange coverd with powder coated sheet 0.25 mm thick and wall angle 24 x 24 x 0.45 mm powder coated for ceiling all as specified and directed.
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long suitable for size of snap grid 605 x 605 mm complete all as specified and directed
S & F for powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium snap beading screws etc. complete all as specified and directed.
S&F prelaminated particle board 12 mm thick interior grade, prelaminated both side with decorative choice lamination as in kitchen cabinets/shutters fixed with screws in aluminium frame work complete all as specified & directed.
S&F Aluminium body, door closer, hydraulically regulated designation No.3,universal type,suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg complete all as specified and directed.
S&F in Mortice locks Brass vertical type size 100mm 4 levers brass chromium plated with keys in duplicate all as specified and directed.
S&F extruded aluminum alloy handles, fabricated type 150mm size all as directed.
S&F Aluminium anodised barrel tower bolts of extruded section 200mm long all as specifed and directed.
S&F butt hinges 125mm size, extruded aluminium alloy with galvanised mild steel hinge pin anodised, type B-21 complete all as specified and directed.
M & L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 Gde E165 complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, n.exc 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for and removing all the rubbish complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard/ dense soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundations & filling in mass concrete complete all as specified and directed.
M & L for 50 mm thick sand cushioning for laying interlocking paver blocks of any size and shape complete all as specified and directed.
M & L for machine pressed precast concrete coloured interlocking paver blocks of any shape and size joints filled with fine sand conforming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as as specified and directed by Engr-in-Charge.
M & L for Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in kerbs stones including necessary formwork, weathering, slightly rounded or chamfered angles and throating all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and directed.
Returning filling in soil including spreading leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
M&L for point wiring with single core 4 Sq.mm size multistranded copper conductor PVC insulated cables and one single core 4 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including rigid PVC CASING & CAPING with accessories,confirming to IS specifications,on wall/ ceiling /trusses with suitable clamps, screws etc., including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting SOCKETS OUTLET 15 Amps multi purpose on independent board ches, sockets, fan regulators etc.,including connecting up and testing, all as specified and as directed.
M&L for point wiring with two single core 4 Sq.mm size multistranded copper conductor PVC insulated cables and one single core 4 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including rigid PVC CONDUIT and conduit accessories,confirming to IS specifications,on concealed in wall/ ceiling /trusses with suitable clamps, screws etc., including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting SOCKETS OUTLET 15 Amps multi purpose on independent board ches, sockets, fan regulators etc.,including connecting up and testing, all as specified and as directed.
M&L for point wiring with single core 4 Sq.mm size multistranded copper conductor PVC insulated cables and one single core 4 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including rigid PVC CASING & CAPING with accessories,confirming to IS specifications,on wall/ ceiling /trusses with suitable clamps, screws etc., including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting SOCKETS OUTLET 5 Amps multi purpose on independent board ches, sockets, fan regulators etc.,including connecting up and testing, all as specified and as directed.
Supply and fix switch socket combination 2 in 1, 3 pin, 6 Amps flush type, matching with existing make ISI marked, all as specified and directed.
Supply and fix switch socket combination 6 Amps/16 Amp, 5 in 1 flush type, multi purpose, matching with existing make ISI marked, all as specified and directed.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 V complete with one all as specified .
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified & directed.
Supply & Fix Voltage stablizer for automatic operation, single phase naturally air cooled indoor type and deisigned for input variation between 170 volts to 250 volts with out put voltage at stablized at 230 volts with accuracy of +/- 2.50% and of capacity 5 KVA.
S&F wiring for circuit/submain wiring alongwith earth wire with 4 run of 6.00 sqmm and 2run of 4.00 sqmm earthwire of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing caping complete all as directed.
Supply & Fix MCB DB SPN 8 way with 200 amps bus bar , double door and factory made complete with bus bar and din channel complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP of 20 Amps current rating complete with connection testing and commissioning.
Supply and fixing amp rating 415V, 10KA 'C' curve miniature circuit breaker (MCB) TPN of 63 Amps current rating complete with connection testing and commissioning.
Supply and fixing including brazing of copper tube with insulation, electrical cable abd drain pipe from indoor unit to outdoor unit suitable for split / floor mounted AC's complete all as specified and directed.
Supply and fixing outdoor stand for mounting outdoor unit of split AC complete all as specified and directed.
Supply & Laying including jointing, testing and commissioning of 3.5 core 120 Sqmm XLPE insulated, armoured, heavy duty, LT UG electric cable with aluminum conductor 1100 volt grade including provision of lugs, glands etc laid in trenches or fixed on wall/pole or drawn through GI pipe complete all as specified and directed by Engineer-in-charge.
Supply and laying double wall corrugated DWC pipe (profiled) of size 100 mm 6 mtr long SN4 with all fittings as in cable protection, laid in trenches all as specified and directed by Engineer-in-charge. Make Astral D-Rex code : A0214100NEC012D or equivalent in Supreme/ Dutron
Supply and lay GI tubing, 'light grade' of size 100 mm ,with all fittings as in cable protection, laid in trenches all as specified and directed by Engineer-in-charge.
S&F in MCB DB TPN 8 way , having degree of protection as IP 43-IK09 with metal door (double door) 415 Volt vertical type complete with 200 Amps rated copper bus bar with neutral link suitable for Four Pole MCCB as incomer and SP MCBs as outgoing and total number of module equals to module for MCCB+24 complete all as directed.Make Indoasian Cat No. 811895( Note : MCCB & MCBs will be measured and paid separately)
Supply & fix MCCB 4 pole , 160 Amps, 415 Volts, 3 phase, with ultimate breaking capacity of 25 KA with thermal magnetic release conforming to IEC600947-II part-I/s IS-13947- Part- I with breaking capacity Ics= Icu at 415 Volts of 25 KA, thermal overload setting 80% to 100%, short circuit setting 5 to 10 times, order voltage and shunt release complete all as specified and directed.Make Indoasian Cat No. 830295 or equivalent in Havells/ABB/L&T
Supply & fix MCCB 4 pole , 160 Amps, 415 Volts, 3 phase, with ultimate breaking capacity of 25 KA with thermal magnetic release conforming to IEC600947-II part-I/s IS-13947- Part- I with breaking capacity Ics= Icu at 415 Volts of 25 KA, thermal overload setting 80% to 100%, short circuit setting 5 to 10 times, order voltage and shunt release including inclosure for 4 pole MCCB complete all as specified and directed. Make Indoasian Cat No 830295 for MCCB and Cat No 811987 for Enclosure equivalent in Havells/ABB/L&T
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP of 5 to 32 Amps current rating complete with connection testing and commissioning.
M&L for making necessary connection for existing LT Feeder Panel copper busbar and making suitable connection to MCCB panel by using copper bus bar having minimum current rating of 200 Amps includind making necessary alternate arrangement in feeder pillar all as specified.
M&L for earthing complete in replacement of old unsv earthing with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground leve, connecting to the galvanised iron earth lead 4 mm dia size, by means of bolts, nuts, check buts and washres of galvanised iron earth lead 4 mm dia size earth lead protection by provision of GI medium grade pipe 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40mm x 40mm x 6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoalfilling, 15cm alternate layer of charcoal and salt around all sides of earth plate with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
M&L for point wiring with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit and making good disturbed surfaces to match with the existing surface complete all as specified and directed by Engr-in-Charge.
Supply and fixing energy saving environment friendly 80 Watt capacity LED industrial medium/high bay luminaire conforming to IP65 complete all as specified and directed.
Supply and fixing heavy duty metallic body exhaust fan of sweep size 600mm alongwith louvers complete, fixing to the window/ceiling/rooftop or any other location at minimum 3 Mtrs height,made up of copper winding complete, and connecting the same from the nearest ceiling rose all as specified and directed by Engr-In-Charge Note: a) The fasterners required for the fixing of the exhaust fans are included in the above quoted rate b) The M&L required for making holes/any alteration for fixing of the fans and making good the old disturbed surface are also including in the above quoted rate
Supply and fix socket outlet 3/5 pin 6 Amps flush type, matching with existing make ISI marked, complete all as specified and directed.
M&L for Wiring circuit / submain wiring alongwith earth wire with 2 run of 4.0 sq.mm and one run of 4 sq.mm earth wire of FR is PVC insulated copper conductor,single core cable in surface/recessed as required In casing/caping complete all as specified and directed by Engr-in-Charge.
Supply & fix in repairs MCB SPN, 32 Amps, 'C Series ,230 Volts, Single phase, 10 KA Capacity all as specified and directed. MAKE: L&T/ABB/Schneider.
K.G.SHANKER
ABDUL RAHIM
KVL CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .