Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC FLAT NO 8 205 SNO 296 2 DIVINE HOMES PORWAL ROAD KSHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹15.4 L+₹46,910 (3.14%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹23.9 L
EMD Value
₹47,860
Closing Date
24 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
PROVN OF LINK ROAD BETWEEN MAP QTRS AND ROAD LEADING TO GATE NO 16 AT CME UDNER GE (CME) KIRKEE
2022_MES_566597_2
CWE/KKE/TOKEN-24 OF 2022-23
Open Tender
Civil Works - Roads
Item Rate
180 days
KIRKEE
AS PER TENDER
5 documents required · 5 mandatory
₹500
Yes
GE CME KIRKEE
₹47,860
Yes
16 Feb 2023
3 Jan 2023
27 Jan 2023
3 Jan 2023
24 Jan 2023
11 Jan 2023
Amount
B/R PORTION Excavation over areas n exc 1.50 m deep and getting out in soft soil/loose soil complete all as specified and directed by Engr-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes pole, etc. n exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes pole, etc. n exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed by Engr-in-charge.
Excavating in trenches, exc 1.5 m wide and n exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point (Soils) complete all as specified and directed by Engr-in-charge.
Rolling and consolidating formation surfaces in cutting with power roller complete all as specified and directed by Engineer-In-Charge. ( exc 8 ton & n exc 12 ton)
M&L for Moorum/red bajri filling in floor pavings laid in layers not exc 15 cm ( 150mm) thick, spread, levelled and rammed including rolled and consolidated to required gradient and camber incl watering with power roller complete all as specified and directed by Engineer-In-Charge.
M & L for 200mm thick (compacted thickness ) Granular Sub Base (GSB) of grade I as per table 400-I of MORT&H ,IRC specification laid with mechanical paver ,rolled and compacted to required gradient and camber with 8 to 10 tonnes power roller and vibratory roller complete all as specified and directed by Engineer-In-Charge.
M&L for 150 mm thick (compacted thickness) Wet Mix Mecadam (WMM) in two layers as per MORT&H specification, using crusher broken graded stone aggregate laid with mechanical paver ,rolled and compacted to required gradient and camber with 8 to 10 tonnes power roller and vibratory roller complete all as specified and as directed by Engineer-In-Charge.
M & L preparing WMM surface by brushing with wire brushes for removing caked mud etc sweeping with broom and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc by cleaning the WBM/WMM surface with power compressor and applying evenly priming/tack coat with bituminous primer of VG-10 grade paving bitumen @ 10 kg/X Sqm complete all as specified and as directed by Engineer-In-Charge.
M&L for 50 mm or less compacted thickness premixed bituminous macadam laid, spread using mechanical paver with 4% binder content by weight of total mix, using paving bitumen binder of grade VG - 30 grade by weight of total mix, rolled and compacted to required gradient and camber using power roller of capacity exceeding 8 tonne but not exceeding 12 tonne complete all as specified and as directed by Engineer-In-Charge.
M&L for preparing new bituminous macadam black top surfaces by brushing with wire brushes for removing cake muds etc sweeping with broom & finally fanning the cleaned surface with gunny bags to remove all loosed dirt etc and applying a priming/tack coat of paving bitumen VG-10 grade paving bitumen @ 2.5 kg /Xsqm complete all as specified and as directed by Engineer-In-Charge.
M&L 40 mm compacted thickness semidence bituminious concrete with bitumen grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) and waste plastic additive @ 8% (percentage by weight of bitumen) by using mechanical paver and vibratory roller, spread, rolled and compacted to required camber and gradient and complete all as specified and as directed by Engineer-In-Charge. NOTE : waste plastic additive @ 8% (percentage by weight of bitumen)
M & L for precast cement concrete type B1 1:2:4 (20mm) aggregate in C:M 1;6 in kerb stone block one side chamfered of approved make and design complete all as specified and directed by Engr-in-charge.
S & F solar cat eye aluminium alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono crystalline solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with10,000 to 18,000 mcd completed as per manufactures instructions etc complete all as specified and directed by Engr-in-charge.
M & L 150mm thick Cement concrete type D2 1:4:8 (40mm Graded agg) in foundations, filling and mass-concrete complete all as specified and directed by Engr-in-charge.
M & L fly ash brick masonry old size built in cement mortar 1:4 complete all as specified and directed by Engr-in-charge.
M & L for cement concrete in type C1 1:3:6 using 20 mm graded Agg built in copings including necessary form work complete all as specified and directed by Engr-in-charge.
M & L Cement concrete in surface channels and drains avg 50 mm thick type B0 1:2:4 using 12.5 mm agg complete all as specified and directed by Engr-in-charge.
M & L for Rendering 10mm thick on fair faces of brick work or concrete surfaces (internal ) with CM 1:6 finished even & smooth without using extra cement in cement plaster complete all as specified and directed by Engr-in-charge.
E/M PORTION S & L and testing cable XLPE insulated screened pvc bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade cross sectional area 4 core 16 Sqmm complete all as specified and directed by Engr-in-charge.
S & L for Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smooth internal and profiled external surface for non pressue under ground cable incl couplers & bends complete all as specified and directed by Engr-in-charge.
S & F LED street light fittings of 90 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy > 120 Im/W and system efficacy 90 Im/W, 240 volts AC, 50 Hz, CRI>70% operating voltage range 160v-270v, power factor>0.95, working temperature range -20oC to 60oC, built in surge protection more than 10KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection including cutting, welding, drilling holes, nut bolts, washer etc complete all as sepecified and directed by Engr-in-charge.
S & F passing through pipe, 1100 volts grade heavy duty, PVC insulated round 3 core 2.5 Sqmm copper cable including electrical connection complete all as specified and directed by Engr-in-charge.
S & F street light bracket made out of GI pipe medium grade 32 mm bore approx length not less than 120 cm bent to shape including new clamps made of MS flat of size 40x5 mm thick including cutting, welding, drilling holes, nut,bolts,washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and directed by Engr-in-charge.
S&F kiosk box made out of fibre material complete with TPN , aluminium bus bar and suitable for one number MCB (SP) including one No MCB (SP)6 Amps 240 voltswith glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-charge.
S & F of automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) three phase load of 8 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF> 10 Lux. The sensor should also have part night operation facility of min. 4 hrs tomax. 12 hrs. VMS should have adjustable over & under voltage trip level and protection against phase loss & Phase reverse incl power contactors (3 nos of capacity 25 amps per phase each) and incoming (3 nos of capacity 32 amps each)- outgoing MCB( 3 nos of capacity 32 amps each) & main load circuit wiring (Copper) of minimum 10 Sqmm.The sensor, VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/ wall mountable enclosure madeof rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option)complete all as specified and directed by Engr-in-charge.
M & L for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/ earth pit not less than 2.25 meter deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth wire of size 4 mm by means of nut, bolts, washers etc to eqpt/ machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @ 10cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engr-in-charge. Note : Earth wire/strip to be secured on bus bar insulators and insulators shall be fixed on pole not more than one metre apart with MS clamps made out of 25x4mm MS flat with nuts, bolts and washers and GI wire/strip shall be fixed in such a way that wire/ strip should not be touch on pole in any case)
M & L for GI pipe light grade with all connected fittings of sizes 40 mm complete as directed by Engr-in-charge.
M & L for steel swaged poles complete with cast iron base plate, finial taperplug, bolts, nuts and screws as specified type 410 SP-31 of 9.00 meter long and including painting with two coats of aluminum paint over a coat of primer including preparation of new surfaces complete all as specified and directed by Engr-in-charge.
M& L for providing plain cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) in foundation filling and mass concrete complete all as specified and directed by Engr-in-charge.
M&L plain cement concrete type C-2, 1:3:6 (using 40mm grade aggregate) as in coping, finished even and fair, including necessary form work complete all as specified and directed by Engr-in-charge.
Galaxy Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .