EE(E)
ED-III, Kellys, CHennai-10
Shifting and rearrangement of Panels and cabling, providing bore well pump, submeter arrangement etc at TE bldg Chrompet in connection with renting out to SBI
2023_BSNL_172121_1
65/EEE/ED-III/BSNL/CH/23-24
Open Tender
Electrical Works
Item Rate
30 days
TE Chrompet
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL
₹10,122
Yes
9 Nov 2023
26 Oct 2023
8 Nov 2023
26 Oct 2023
7 Nov 2023
26 Oct 2023
26 Oct 2023 - 7 Nov 2023
Dismantling and removing of Main LT panel of Face Area(7.00*2.00M) including disconnecting and removing the cables with glands,earth connection at G/F area i/c shifting same to Car carrage at Qtrs Bdlg etc as reqd
Dismantling and removing of Capacitor Panel of Face Area(2.40x1.7m) including disconnecting and removing the cables with glands,earth connection at G/F area i/c shifting same to Car carrage at Qtrs Bdlg etc as reqd
Dismantling and removing of Dry Transformer of 315KVA Capacity including disconnecting and removing the cables with glands,earth connection at G/F area i/c shifting same to Car carrage at Qtrs Bdlg etc as reqd
Dismantling and removing of Old LT panel of Face Area(1.7*2.10M) in the G/F varanda including disconnecting and removing the cables with glands,earth connection at G/F area i/c shifting same to Car carrage at Qtrs Bdlg etc as reqd
Dismantling and removing of bus bar duct from Transformer to Main LT panel of size (0.75x0.35x14mM) in the ss area including disconnecting bus bar,earth connection i/c shifting same to Car carrage at Qtrs Bdlg etc as reqd
Removing of Solar Panel from SS area and reinstalling the same in the EB room i/c removing the cable with termination and relaying the same at new location etc as reqd
Removing of ATM meter from SS area and reinstalling the same in the EB room i/c removing the cable with termination and relaying the same at new location etc as reqd
Removing of standby HT cable termination box of 1.00x0.4m face area from SS area etc as reqd
Removing the cable duct manual cover in the ss area of size 0.6x25m and shifting the same to Qtrs carrage etc as reqd
Removing of Power cable on the existing wall / tray/duct/pipe from 3 1/2x25Sqmm to 3 1/2 x 185 sqmm and rolling the same and shifting to Qtrs carrage….etc as required
Supply &Laying of following size of PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade on surface/ in panel etc as reqd
a)4x25Sqmm cable
b)4x50Sqmm cable
Dismantling and removing of 3nos Old LT panel of Face Area(1.2x2.00M) in the G/F power room including disconnecting and removing the cables with glands,earth connection etc as reqd
Dismantling and removing of 1nos Old AC panel of Face Area(1.5*1.2M) in the F/F varanda including disconnecting and removing the cables with glands,earth connection etc as reqd
Dismantling and removing of TPN DBs(Vertical type) in the G/F varanda and DGM room including disconnecting and removing the wires/cables with glands,earth connection etc as reqd
Dismantling and removing of 100/125ASwitch in the G/F battery room including disconnecting and removing the wires/cables with glands,earth connection etc as reqd
ITC of TPN DBs(Vertical type) on surface of wall with necessary tools and plants and manpower etc as reqd
Laying of old existing one number PVC insulated and PVC sheathed Aluminium Conductor armoured cable of following sizes on surface of wall with all accessories etc. as required.
a)Upto 35 sqmm
b)Above 35 sq. mm and upto 95 sq. mm
c)Above 95 sq. mm and upto 185 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
a)4 X 25 sq. mm
b)3½ X 70 sq. mm
c)3½ X 95 sq. mm
c)3½ X 185 sq. mm
Shifting and Transporting of existing old LT panel ( face area 2.20x1.30m) from east Tambaram Exchange i/c loading and unloading same at both the places with necessary tools and plants (crine/tripod) with specilised manpower and installing in EB meter board room at TE Chrompet and testing commissioning etc as reqd
Dismantling and Shifting of existing old AC plant LT panel from AC package room to F/F varanda i/c disconnecting and removing the cables with glands,earth connection and reinstalling same at new location with necessary tools and plants with all accessories and testing commissioning etc as reqd
Dismantling and Shifting of existing old LT panel from substation room to G/F EB meter board room and reinstalling same with necessary tools and plants with all accessories and testing commissioning etc as reqd
Supplying and fixing of following of items in the existing Fittings and fans including removing the faulty items etc as reqd
a) 40 W Flourescent lamp
b) Electronic Choke
c) Side holder
Dismantling of 1.5 TR STAC units including removing the indoor and outdoor units ,copper pipes , ecectrical cables etc as reqd
Shifting and Installation,Testing and commissioning of existing 1.5 TR STAC units etc as reqd
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Group C)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b)2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Installation, Testing and commissioning of 48" Ceiling fan along with suitable length down rod, anchor fastener, modular step type regulator i/c wiring the down rod etc. as required.
Providing and fixing 16" sweep wall mounting fan oscillating type with 3 speed regulator suitable length of cord wire and suitable for working on 230 Volts AC etc as reqd. (Make : Crompton Greaves or SS make)
S/F 20W LED patty type fitting on the surface of wall with all accessories etc as reqd
SITC of 3HP/2.2KW, 20 stage submersible pump suitable for operating in 3 phase, 280-440V, 50Hz supply with head range of 132-110 mtrs and flow range of 0-45 LPM in the existing borewell i/c providing nylon rope of required length for supporting the pump in the borewell etc. as reqd. (make: Kirloskar, KS4C-3020 / Similar Superior)
SITC of Three Phase Electronic control panel suitable for Submersible Pump having Digital voltmeter & Ammeter,Single phase preventor,thermal overload,Voltage high/low cut off and electronic dry run protection, RYB indication,3pole MCB, Dry run auto restart timer(10-720min) on surface of wall i/c making connections etc. as reqd (make: Raxa / similar superior)
Supplying and laying of 40mm HDPE pipe of 6kgf/sqcm (PN 6), PE 63 grade in the existing borewell etc. as reqd.
Supplying and fixing of 38mm S.S pipe nipple for pump etc. as reqd.
Supplying and laying of 3core 2.5sqmm FR PVC insulated copper conductor flat submersible cable in the existing borewell / PVC / metal pipe etc. as reqd.
Supplying and fixing of 38mm Gun Metal horizontal type Non-Return Valve (ISI marked) in the existing pipeline etc. as reqd.
S/F 1/2 "dia poly propelene rope for holding the submersible pump and pipe in the existing bore well i/c laying the rope along with the pipe complete as reqd
Supplying and fixing of bore clamp suitable for 6" dia bore with all accessories etc. as reqd.
Removing of cable /conduit/copper pipe covering MS truff of various size width on the surface of wall with all accessories i/c shifting the removed truff to Qtrs car carrage etc as reqd
Removing of AFD cable on surface of wall/ceiling/partion i/c shifting the removed truff to Qtrs car carrage etc as reqd
Relaying of existing old AFD cable on surface of wall with all accessories etc as reqd
Removing of AFD hooter /detector/MCP with all accessories etc as reqd
Dismantling & Removing the all the Electro mechanical items like,Switch boards with its connected wiring system (M.S metal /PVCconduit system),all types of fittings,all types of fans, etc with necessary tools and plant and man powers in the G/F except CSC,cable chamber room and battery and power i/c shifting and keeping the dismantled items in the place earmarked by incharge etc as reqd
1. all types of Ceiling/exhaust fan-20nos(aprox) 2. Air circulator 16/24”-3nos(aprox) 3. Single/Twin/industrial/ Mirror optic fitting-45nos(aprox) 4. DC fitting-5nos(aprox) 5. 20A AC unit metal box-4nos(aprox) 6.Switch boards/15/5A power plug boards=40nos(aprox) 7. 20/25 mm dia MS/PVC conduit with wiring=450M(aprox) 8. Power restoration alarm=1no 9. Fire Extinguisher =4nos 10. Fire Bucket=4nos All put together
Supplying and Fixing Projection Mounted (base mounting) with LCD display AC 3Phase and neutral Static Energy ( kWh ) meter of Accuracy Class 1.0, rating 10-100A, 3x240V, 50Hz i/c necessary accessories for SBI bank complete etc as required.(Make:L&T)
Supplying and Fixing Projection Mounted (base mounting) with LCD display AC 3Phase and neutral Static Energy ( kWh ) meter of Accuracy Class 1.0, rating 10-60A, 3x240V, 50Hz i/c necessary accessories for CGHS complete etc as required.(Make:L&T)
S/F of SMC type meter box of size notless than 520mmx420mmx190mm with 9 mm thick hylam sheet and 3x100A fuse cutt out with base and neutral link with all accessories on the surface of wall etc as reqd
PRASANTH ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .