Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.0 LAccepted-AOC 4 243A LAKSHMI NAGAR ACHIPATTI PANCHAYAT POLLACHI COIMBATORE TAMILNADU 642002 | COIMBATORE | TAMIL NADU | 642002 | ₹66.0 L Quoted ₹69.9 L | L1 | Accepted-AOC ACCEPTED AS L1 CONTRACTOR |
| 2 | L2₹71.9 LRejected-AOC | ₹71.9 L | L2 | Rejected-AOC REJECTED SINCE RATE QUOTED ARE HIGHER THAN L1 |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-DOCUMENT NOT FULFILLED |
| Sl No | Description | Qty | Unit | rvk construction L2 | SABARI BUILDERS L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for Pressed tiles & weathering course directed by the Departmental officers Complying with standard specification. | 88.9 | Sq.m | 58 ₹5,156.20 | 57 ₹5,067.30 |
| 2.00 | Dismantling, clearing away and carefully Clean removal of cement plaster from walls. | 78.4 | Sq.m | 10 ₹784 | 12 ₹940.80 |
| 3.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Plain cement Concrete as directed by the Departmental officers Complying with standard specification. | 30.1 | Cu.m | 623 ₹18,752.30 | 606 ₹18,240.60 |
| 4.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Damaged floor finishing wall in Cement Mortar with Mosiac/Glazed Tiles/Clay Tiles/Cuddapah Slabs as directed by the Departmental officers Complying with standard specification. | 922 | Sq.m | 78 ₹71,916 | 76 ₹70,072 |
| 5.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Doors & windows including removal of frames, hinges and fastenings as directed by the Departmental officers Complying with standard specification. | 75 | Sq.m | 197 ₹14,775 | 191 ₹14,325 |
| 6.00Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. | |||||
| 6.01 | For Superstructure in First Floor | 8 | Cu.m | 5,236 ₹41,888 | 5,092 ₹40,736 |
| 7.00 | Finishing the top of roof with one course of Machine Pressed tiles of size 230mmx230mmx20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers | 89 | Sq.m | 1,575 ₹1.4 L | 1,531 ₹1.4 L |
| 8.00 | Repointing the damaged joints at the top of roof with one course of avaliable Machine Pressed tiles of size 230mmx230mmx20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers | 129 | Sq.m | 446 ₹57,534 | 434 ₹55,986 |
| 9.00 | Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. | 73 | Cu.m | 307 ₹22,411 | 298 ₹21,754 |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
10 Sept 2025, 3:00 pmClosed
SUPERINTENDING ENGINEER
O/o THE SUPERINTENDING ENGINEER PWD BUILDINGS CONSTRUCTION AND MAINTENANCE CIRCLE COIMBATORE
Special Repairs to old boys hostel building 1 and 2 in Government Coimbatore Medical College at Coimbatore District.
2025_PWD_598390_1
32BCMCBE19082025
Open Tender
Civil Works - Buildings
CMCH HOSPITAL
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹45,000
27 Jan 2026
30 Aug 2025
10 Sept 2025
30 Aug 2025
10 Sept 2025
30 Aug 2025
Amount
Dismantling, clearing away and carefully stacking materials useful for re-use for Pressed tiles & weathering course directed by the Departmental officers Complying with standard specification.
Dismantling, clearing away and carefully Clean removal of cement plaster from walls.
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Plain cement Concrete as directed by the Departmental officers Complying with standard specification.
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Damaged floor finishing wall in Cement Mortar with Mosiac/Glazed Tiles/Clay Tiles/Cuddapah Slabs as directed by the Departmental officers Complying with standard specification.
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Doors & windows including removal of frames, hinges and fastenings as directed by the Departmental officers Complying with standard specification.
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
For Superstructure in First Floor
Finishing the top of roof with one course of Machine Pressed tiles of size 230mmx230mmx20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
Repointing the damaged joints at the top of roof with one course of avaliable Machine Pressed tiles of size 230mmx230mmx20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for Foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers - Mixing by mechanical means.
Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) - Mixing by manual means
Providing Granolithic Floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)-Machine Mix
40mm Thick
Brick work in Cement Mortar 1:5 (One Cement and Five Crushed stone sand) using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for the following including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge.
For Foundation & Basement
Brick work in Cement Mortar 1:3 (One Cement and Three Crushed stone sand) using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for the following including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge.
For Foundation & Basement
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.6m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2.00m x 2.00m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick), etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers (Payment for centering shallbe given after the concrete is laid
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation & Basement
Supplying, fabricating and placing in position Mild Steel/ Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given for the following including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
For Foundation & Basement
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Paving the floor with best quality Double charged Vertified tiles 600 x 600 x 8mm size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Flooring with Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Renewing the damaged window shutter with new COUNTRY WOOD GLAZED WINDOW SHUTTER including fixing in position with hinges but excluding cost of furniture fittings etc., complete complying as directed by the departmental officers as per standard specification.
Renewing the damaged door shutter with new COUNTRY WOOD fully panelled DOOR SHUTTER including fixing in position with hinges but excluding cost of furniture fittings etc., complete complying as directed by the departmental officers as per standard specification.
Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided 1no. Aldrop is provided at lock rail section in the door 2 Nos of 200mm handle are to be provided. One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place.
Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 1.00m x 2.10m.
Supply & fixing of WPC (Wood Polymer Composite) Frame extruded with size 75mm x 50mm. The single core door made of rigid WPC compound with minimum Bulk Density of 900 KG/ Cub.Mt. & shore hardness of 55. Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/ Cub.Mt. & shore hardness of 55. For the aesthetic appearance, the door shall be a printed digitally on one side of the shutter and the design is as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the WPC frame with 3 Nos of 5” SS Hinges and the door shall have 2 towerbolt on one side and 1 towerbolt or aldrop on other side for locking system and 2 numbers of handle on the either side of the door shutter, all made of aluminium etc., complete complying with standard specifications and as directed by the departmental officers.
Supplying and fixing solid core flush shutter of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos SS 304 Grade Butt Hinges of size (125mm x 30mm) , 2 Nos .300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf.
Supplying Fabricating and fixing of M S GRILL for open court yard grill, grill work to doors, windows and ventilators with required size and angles including with necessary M.S. Channels, ' L ' angles, M.S. Plate as per the approved special designed including cost of materials and labour charges for cutting angle, welding charges including cost of welding rod conveyance charges at site of work including cost of one coat of red oxide primer etc., complete and as directed by the departmental officers.
Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm ( without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply- Above ground level.
40mm dia
32mm dia
25mm dia
20mm dia
Supplying and fixing in position the following UPVC Specials of following dia and approved quality and good variety excluding fixing charges but including necessary cutting and threading of UPVC pipes, jointing the UPVC specials and jointing the specials with pipe line using UPVC adhesives etc., complete complying with standard specification. (The UPVC specials should be got approved by the Executive Engineer concerned before use on works.)
40mm dia UNION
32mm dia UNION
25mm dia UNION
20mm dia UNION
40mm dia ELBOW
32mm dia ELBOW
25mm dia ELBOW
20mm dia ELBOW
40mm dia TEE
32mm dia TEE
25mm dia TEE
20mm dia TEE
40mmx32mm dia REDUCER
32mmx25mm dia REDUCER
25mmx20mm dia REDUCER
20mmx15mm dia REDUCER
25mm dia HEX NIPPLE
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
40mm dia
32mm dia
25mm dia
Supplying and fixing in position best quality PVC soil / waste pipes of following dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
110mm dia
75mm dia
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
110mm dia ELBOW
110mm dia TEE
110mm dia Y
75mm dia ELBOW
75mm dia TEE
75mm dia Y
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
CI Nahani Trap of size 100 x 75mm with stainless steel gratings
Supplying and fixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Painting Old wood work with Two coat of synthetic enamel ready mixed paint of approved quality and colour in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting New Wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting New Iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting Old Plastered Wall Surface with Two finishing coats of weather proof Exterior Emulsion paint of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying and fixing in position SFRC manhole covers with SFRC frames of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications.
Supplying and fixing of PVC ready made WATER TANK of 1000 Litre capacity of best and approved quality with ISI specification and having inlet,outlet, overflow and clearing pipe arrangements and labour charges for fixing in position with all necessary accessories and transporting at site of work including necessary brick work conveyance loading, unloading labour for fixing etc., complete complying as directed by the departmental officers.
Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of Fly ash Brick of 23x23x7cm size with Class designation of 7.5 and Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
Clear Size 0.60mx0.60m
rvk construction (BID ID -1454123)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid