| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹23.1 LAccepted-AOC NO 422 CHURCH STREET NEW THIPPASANDRA BANGALORE 560075 | BANGALORE | BANGALORE | KARNATAKA | 560075 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹23.7 LRejected-Finance NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹26.3 LRejected-Finance 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | THIRD | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
18 Apr 2022, 6:00 pmClosed
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
PROVISION OF INDOOR SPORTS AND RECREATION FACILITY ALONGWITH THREE PHASE SUPPLY IN SNCO MESS AT GV CAMP AND IRON SHED FOR FIRE POINTS UNDER GEAF MARATHAHALLI
2022_MES_514794_1
8933/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE (AF) MARATHAHALLI
₹44,000
Yes
30 Apr 2022
22 Mar 2022
23 Apr 2022
22 Mar 2022
18 Apr 2022
5 Apr 2022
Amount
Surface dressing n. exc. 15 cm deep in Hard/dence soil and getting out.
Removing excavated material to a distance exc. 1.50 km but n. exc. 5 Km and depositing where directed complete all as directed.
M&L for broken stone or boulders hardcore of gauge n. exc. 63 mm, deposited spread and levelled in layers n. exc. 15 cm thick each, watered and rammed to a true surface.
M&L for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete.
M&L for 100 mm thick Cement concrete in sub floors, sub bases, floor and pavings etc.1:2:4, type B-2 using 20 mm graded crushed stone aggreagate complete all as specified and as directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface as in hard/dense soil.
M&L for PCC 1:3:6 Type C2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
S&F Steel work in tubular trusses, purlins, rails and fastening and heavy bracket framing including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240
S&F Pre-laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof coveringin any curvature, fixed with self tapping screws as specified.
S&F Fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixe with coach screw and washer in roof, wall etc. fixed with self tapping screws as specified.
M&L for steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying 2 coats of synthetic enamel paint over a coat of red oxide primer.
M & L for preparing new concrete/stone surfaces plain or moulded,exc 10cm width or girth when unconnected with other painting or when painted in a different tint of any description and applying two coats of synthetic enamel paint over a coat of priming paint on plaster coat all as specified
Demolition of cement concrete of any description and any position not otherwise specifically provided for.
S & F 1.0mm thick Plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) as in roof covering/cladding to wall, fixed with self tapping screws as specified
M & L for 50 mm thick cement concrete, 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in flooring all as specified and as directed.
M & L for 50 mm thick cement concrete , 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in flooring all as specified and as directed.
Material and Labour for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non metallic rigid medium grade PVC conduit with all accessories alongwith fixing arrangements in walls , roofs , floors etc., or fixed in walls and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor connected to common earth dolly providing suitable size mild steel terminal boxes concealed in wall with 3 mm thick hylum sheet top cover to accommodate switches, fan regulators, sockets, socket outlets, etc, all as specified and as directed for One light point controlled by one switch.
Supply and fix Switch piano flush type single pole one way 5 Amps, 230 V complete all as specified
Supply and fix ceiling rose surface PVC / polycarbonate isolated body with three terminals all as specified and as directed.Make: Anchor / Legrand /Havells/ standard
Supply & fix LED flood /focus light indoor type 120 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection system efficiency LFLN_120-CDL/60-M High bay / focus light indoor type, 110 W Make: crompton / Havells / Bajaj/ Phillips
Material and Labour for Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. NOTE : 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.
Supply and Fixing MCB DB SPN 8 way, Double door, 240 V, AC, 50 Hz, with 200Amp rated bus bar
Supply and Fixing MCB SPN 32 Amps rating, 10 KA 'C 'curve, 240V, 50 Hz AC Complete all as specified and as directed.
Supply and Fixing MCB SP 5 to 32 Amps rating, 10 KA Ç 'curve 240V, 50 Hz AC Complete all as specified and as directed.
Supply and Fixing in MCCB 3 pole, 25 to 100A rating, with breaking capacity 36 KA Ç 'curve 415 V, adjustable type 50 Hz AC Complete all as specified and as directed.
Earthing complete with galvanisedsteel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below groundlevel) with top edge of the plate notless'than 1.5 metres below normalground level, connected to galvanised earth lead 4 mm GI Wire by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point .The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 CTD bar reinforcement both ways at 140 mm bents to centre complete and provision 20mm GI pipe one for water pouring one for earth elctrode all as directed by Engr-in-Charge. all as specified or indicated including testing on completion
Supply and fixing LTUG cable of size 16 Sqmm , 4 core XLPE insulated screened PVC bedded, galvanised steel strip wounded ,electric power cable 1100 volts ,with stranded aluminium conductor and making connection with suitable lugs complete all as specified and directed.Note: (i) Earth work excavation , sand cushioning, bricks for protection, GI pipe etc shall be measured and paid for separately under relevant items of this schedule.
Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete all as specified and directed.
Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick complete all as specified and as directed
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified and as directed.
Material and labour for Sand cushioning to cables with a layer of sand before and after laying the cable complete all as specified and as directed. Note :- Sand shall be measured after punned down.
Material and labour for Brick protection cover on cable with sub class 'B' bricks, across in trenches laid dry and flat adjacent to each other complete all as specified and as directed
Material and labour for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts including taking down/up old unserviceable GI tubing complete all as specified and as directed.
Supply and fixing LTUG cable of size 25 Sqmm , 4 core XLPE insulated screened PVC bedded, galvanised steel strip wounded ,electric power cable 1100 volts ,with stranded aluminium conductor and making connection with suitable lugs complete all as specified and directed.Note: (i) Earth work excavation , sand cushioning, bricks for protection, GI pipe etc shall be measured and paid for separately under relevant items of this schedule.
Supply and fix 3 Pole MCCB 25 to 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA .
Supply and fix MCCB DB TP,metal box encloser 200 amps rated all as specified.
Material and labour for Cutting PCC / road 150mm thick for laying of LT UG cable and making good the disturbed surfaces with cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate complete all as specified and directed.
M & L for pre cast cement concrete block masonry with solid block exc 10 cm thk in width (with plain or interlocking joints as directed) complete, in walls and set in cement mortar 1:6 of PCC 1:3:6 (Type C1) all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on brick or concrete surfaces finished even and smooth without using extra cement all as specified and as directed.
M & L for Three coat of white wash on newly plastered surfaces of walls including necessary preparation of surfaces all as specified and as directed.
PRAGATHI BUILDERS
G K CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .