Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.1 LAdmitted-Finance | ₹59.1 L | L1 | Admitted-Finance |
| 2 | L2₹74.0 LAdmitted-Finance | ₹74.0 L | L2 | Admitted-Finance |
| 3 | L3₹78.7 LAdmitted-Finance | ₹78.7 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not qualifying for opening of financial bid due to unsatisfactory performance of the agency their ongoing/ recently completed works in DCSEM |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not qualifying for opening of financial bid due to unsatisfactory performance of the agency their ongoing/ recently completed works in DCSEM |
| Sl No | Description | Qty | Unit | M/S.S.V.CHANDAN L2 | M/S.SHREEJEE PAINTS L3 | PANJA CONSTRUCTION L1 |
|---|---|---|---|---|---|---|
| 1.00 | PART I : CIVIL WORKS | 1 | No | 73,96,200 ₹74.0 L | 78,73,500 ₹78.7 L | 59,05,500 ₹59.1 L |
Tender Value
₹1.1 Cr
EMD Value
₹2.3 L
Closing Date
29 Dec 2025, 3:00 pmClosed
Chairman GB
3rd floor VS Bhavan, Mumbai
Building Work/ Building Maintenance Work/ Building Renovation Work
2025_DCSEM_888659_1
DCSEM/CQD/QSB/25-26/NIT/63 dt.05.12.2025
Open Tender
Civil Works - Buildings
548 days
Anushaktinagar, Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹0
₹2.3 L
21 Apr 2026
5 Dec 2025
31 Dec 2025
5 Dec 2025
29 Dec 2025
12 Dec 2025
5 Dec 2025 - 12 Dec 2025
PART I : CIVIL WORKS
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
PART I : CIVIL WORKS
Providing & applying white / colour washing in two or more coats on old / new surfaces at all floors, levels & location using ready mix lime powder of approved quality by adding glue, blue/colour of approved shade including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge.
Providing and applying 1.5 mm thick white cement based wall care putty in two coats of approved make, at all floors, levels and locations, over plastered surfaces finished smooth to correct line, level, plane, plumb etc., including preparing the surfaces, scaffolding smoothen the putty surfaces with very fine water proof emery paper to get a glossy finish etc. complete as per specifications, as per manufacturers specifications, drawing & as directed by the Engineer-in-charge.
Providing & applying acrylic oil bound distemper in two or more coats on old / new surfaces at all floors, levels & location using ready mixed & ready made acrylic oil bound distemper of approved make and shade including one coat of approved cement primer (water thinnable) including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Acrylic distemper shall have VOC content less than 50 grams/ litre)
On Old Surfaces (Including thoroughly scrapping, removal of old paint, if any, sand papering & preparing the surfaces, applying approved putty for touch up to fill up crevices mild depression etc, necessary covering material (tarpaulin etc), cleaning, removal of splashing & droppings of floors, wall, ceiling, doors & windows etc & disposing of debris at directed place inside colony. )
Providing & applying acrylic emulsion (plastic) paint for internal plastered surfaces in two or more coats on old / new surfaces at all floors, levels & location using ready mixed & ready made acrylic emulsion paint of approved make and shade including one coat of approved cement / acrylic primer (water thinnable) including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Acrylic emulsion shall have VOC content less than 50 grams/ litre)
On Old Surfaces (Including thoroughly scrapping, removal of old paint, if any, sand papering & preparing the surfaces, applying approved putty for touch up to fill up crevices mild depression etc, necessary covering material (tarpaulin etc), cleaning, removal of splashing & droppings of floors, wall, ceiling, doors & windows etc & disposing of debris at directed place inside colony. )
Providing & applying premium acrylic emulsion (plastic) paint for internal plastered surfaces in two or more coats on old / new surfaces at all floors, levels & location using ready mixed & ready made acrylic emulsion paint of approved make and shade including one coat of approved cement / acrylic primer (water thinnable) including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Premium Acrylic emulsion shall have VOC content less than 50 grams/ litre)
On Old Surfaces (Including thoroughly scrapping, removal of old paint, if any, sand papering & preparing the surfaces, applying approved putty for touch up to fill up crevices mild depression etc, necessary covering material (tarpaulin etc), cleaning, removal of splashing & droppings of floors, wall, ceiling, doors & windows etc & disposing of debris at directed place inside colony. )
Providing & applying flat oil paint in two or more coats on old / new surfaces at all floors, levels & location using ready mixed & ready made flat oil paint of approved make and shade including one coat of approved cement primer (water thinnable) including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Flat Oil Paint shall have VOC content less than 50 grams/ litre)
On Old Surfaces. (Including thoroughly scrapping, removal of old paint, if any, sand papering & preparing the surfaces, applying approved putty for touch up to fill up crevices mild depression etc, necessary covering material (tarpaulin etc), cleaning, removal of splashing & droppings of floors, wall, ceiling, doors & windows etc & disposing of debris at directed place inside colony. )
Providing & applying synthetic enamel paint in two or more coats on old / new wooden / steel surface, at all floors, levels & location using ready mixed & ready made synthetic enamel paint of approved make, shade and pattern including one coat of approved wood / steel primer including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Synthetic enamel paint shall have VOC content less than 50 grams/ litre).
On wooden surfaces including one coat of wood primer
On Steel surfaces including one coat of steel primer (red oxide based)
Providing, applying and finishing with french spirit polish over old / new, wooden surface, at all floors, levels & location using two or more coats of french spirit polish over a coat of wood filler to form uniform neat finish, of approved make, shade and pattern including labour, material, scaffolding, surface preparation using sand paper & wood filler, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge.
Repairs to damaged RCC structural members at all locations/ floors using polymer modified cementatious mortar, for strengthening the existing RCC structural members using acrylic based polymer and comprising the following operations: 1. Breaking cracked / spalled concrete members along the cracks with plaster, including removing and stacking of all unserviceable material at site,simultaneous transportation and disposed at a location in Anushaktinagar as identified by EIC. complete all as per specifications and as directed by the Engineer-in Charge. 2. Exposing and cleaning the reinforcement thoroughly by light tapping / wire brushing of using strong emery paper and finally by acetone /rust remover of Dr. Fixit / Anuvi chemicals / Fosroc or other eqivalent. 3. Applying a coat of polymer and cement slurry in the ratio 1:1 by volume to the reinforcement bars. 4. Polymer required for the work shall be procured by the Agency from approved Manufacturers Like M/s Astra , M/s Anuvi, M/s Apcotex or other approved equivalent manufacturer confirming to technical requirements as below and the invoices/challans etc to be submitted to EIC for record. Appearance: Milky white Ph- value : 9-10 Specific gravity : 1.055+/-0.005 Solid contents(%w/w)-: 44+/-1 Viscocity at 25 degree C temperature (in sec): 15-20 Testing of the material as per relevant codes at NABL approved third party Lab. is to be done by the Agency for every batch/lot of supply. 5. Bond coat should be applied @ 0.37 ltr./layer/sq.m. 6. Minimum FM of silica sand should be 2.10
Building up with polymer modified cementatious mortar for RCC structural members etc. in layers not exceeding 20 mm in a day (proportion – cement 50 Kg. : Silica sand 125 Kg. : polymer liquid 10 ltrs.) with necessary bond coat (polymer : Cement = 1:1 by volume) for tack coat and also for subsequent layers using polymer including curing, covering the flooring /window with tarpaulins or equivalent covering material to avoid deposition of polymer mortar and cleaning of floor / windows thoroughly on completion of repair work etc. complete all as per specifications and as directed by the Engineer-in-charge. Polymer used for this work in KG shall be measured for payment.
Cement plastering work using cement sand mortar and finished thickness as specified below without neat cement punning, at all floors, levels & locations, in single/ double coat (as specified) over concrete/ masonry surface including surfaces preparation, even & smooth surface in correct line, level, plane, plumb and including scaffolding, curing etc complete all as per specifications and as directed by EIC. a) Using ready mix cement mortar having Cement : Sand (1:4)
15 mm thick
Providing & applying exterior grade 100% acrylic emulsion paint for external surfaces (plastered / concrete) in two or more coats on old / new surfaces at all floors, levels & location using ready mixed & ready made acrylic emulsion paint of approved make, shade and pattern including one coat of approved acrylic based water repellent primer including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Acrylic emulsion shall have VOC content less than 50 grams/ litre. UV resistance as per IS:15489, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.
Over Sand faced plaster and RCC Jalli .
Providing, applying and finishing with silicon & acrylic emulsion based water thinable sealer (Damp block) over old / new, concrete/plastered surface, at all floors, levels & location using two or more coats to form uniform neat finish, of approved make material suitable for wet/damp surface, shade and pattern including labour, material, scaffolding, surface preparation using sand paper, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge.
stage.html
html • 0.03 MB
techsummary_934042.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tender_Acceptence.pdf
Tender Documents • 0.17 MB
Annexure_II.pdf
Tender Documents • 0.54 MB
Undertaking.pdf
Tender Documents • 0.30 MB
BOQ_934042.xls
BOQ • 0.35 MB
Technical_Bid_NIT_63.pdf
Tender Documents • 1.76 MB
Technical_data_sheet.xls
Tender Documents • 0.09 MB
Download all tender documents and submit your bid