Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC KRISHNA SOCIETY OPP TODI XRAY AND DIAG CENTRE MAKUM ROAD TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | ₹17.1 L Quoted ₹17.6 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹18.0 L+₹42,819 (2.43%)Rejected-AOC | ₹18.0 L+₹42,819 (2.43%) | L2 | Rejected-AOC Other Than Lowest Bidder |
| 3 | L3₹18.8 L+₹1.2 L (6.85%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹18.8 L+₹1.2 L (6.85%) | L3 | Rejected-AOC Other Than Lowest Bidder |
| 4 | L4₹19.4 L+₹1.8 L (10.3%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | ₹19.4 L+₹1.8 L (10.3%) | L4 | Rejected-AOC Other Than Lowest Bidder |
| 5 | L5₹19.6 L+₹2.0 L (11.2%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹19.6 L+₹2.0 L (11.2%) | L5 | Rejected-AOC Other Than Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Jan 2020, 6:00 pmClosed
CWE(AF) Chandigarh
HQ CWE(AF) Chandigarh PIN 160003
SPECIAL REPAIR TO OVER HEAD CABLE TO UG CABLE AT OLD SMQ AREA AT AIR FORCE STATION AMRITSAR CANTT
2019_MES_301581_2
CWE/AF CHD/ASR/T-20/2019-20
Open Tender
Civil Works
Item Rate
180 days
Amritsar
As per NIT
8 documents required · 8 mandatory
₹500
AGE(I) AF Amritsar
₹60,000
Yes
22 Feb 2020
18 Dec 2019
15 Jan 2020
18 Dec 2019
10 Jan 2020
27 Dec 2019
Amount
E & M Works
Dismantling of street light fittings any capacity including bracket, complete all as specified and directed.
Dismantling of ACSR Conductor, any size and capacity, from service feeder span, complete all as specified and directed.
Dismantling of Insulator any type, any size and any capacity, complete all as specified and directed.
Demolition of concrete bed block and taking out of Stay assembly including stay strand, complete all as specified and directed.
Dismantling structural steel in cross arms of MS Channel or angle channel or angle section etc, and removal, to store for reuse or credit complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling (soil) in trenches including spreading, levelling and well ramming in layers not exceeding 25 cm thick each, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Material and labour, locally available, sub class `B’ bricks (old size), laid flat and dry perpendicular to the direction of cable adjacent to each other, in trenches over the cable for protection, complete all as specified and directed.
Supply and laying / fixing , GI pipe light grade 80mm bore for cable protection, laid in trenches or fixed to pole/wall or laid under floor/road/pavement including all fittings, complete all as specified and directed. Note(s): (i) Excavation and earth work shall be measured and paid separately. (ii) MS Clamps with fixing bolts, nuts & washers etc as required shall be measured and paid separately.
Supply and laying / fixing , GI pipe light grade 50mm bore for cable protection, laid in trenches or fixed to pole/wall or laid under floor/road/pavement including all fittings, complete all as specified and directed. Note(s): (i) Excavation and earth work shall be measured and paid separately. (ii) MS Clamps with fixing bolts, nuts & washers etc as required shall be measured and paid separately.
Supply and laying / fixing , GI pipe light grade 40mm bore for cable protection, laid in trenches or fixed to pole/wall or laid under floor/road/pavement including all fittings, complete all as specified and directed. Note(s): (i) Excavation and earth work shall be measured and paid separately. (ii) MS Clamps with fixing bolts, nuts & washers etc as required shall be measured and paid separately.
Supply and laying / fixing , GI pipe light grade 32mm bore for cable protection, laid in trenches or fixed to pole/wall or laid under floor/road/pavement including all fittings, complete all as specified and directed. Note (s): (i) Excavation and earth work shall be measured and paid separately. (ii) MS Clamps with fixing bolts, nuts & washers etc as required shall be measured and paid separately.
Supplying, laying, testing, connecting and commissioning under ground LT cable with aluminium stranded conductor, size 240Sqmm, 3.5core, 1100 Volts grade, heavy duty, XLPE insulated, armoured, complete laid in trenches/fixed to pole or laid under floor /drawn through pipe, with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Note : Excavation & earthwork for trenches, protection bricks/concrete blocks, MS Pipes/PVC Pipes with MS Clamps, bolts & nuts, washers etc, shall be measured and paid separately.
Supplying, laying, testing, connecting and commissioning under ground LT cable with aluminium stranded conductor, size 185Sqmm, 3.5core, 1100 Volts grade, heavy duty, XLPE insulated, armoured, complete laid in trenches/fixed to pole or laid under floor /drawn through pipe, with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Note : Excavation & earthwork for trenches, protection bricks/concrete blocks, MS Pipes/PVC Pipes with MS Clamps, bolts & nuts, washers etc, shall be measured and paid separately.
Supplying, laying, testing, connecting and commissioning under ground LT cable with aluminium stranded conductor, size 150Sqmm, 3.5core, 1100 Volts grade, heavy duty, XLPE insulated, armoured, complete laid in trenches/fixed to pole or laid under floor /drawn through pipe, with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Note : Excavation & earthwork for trenches, protection bricks/concrete blocks, MS Pipes/PVC Pipes with MS Clamps, bolts & nuts, washers etc, shall be measured and paid separately.
Supplying, laying, testing, connecting and commissioning under ground LT cable with aluminium stranded conductor size 120Sqmm, 3.5core, 1100 Volts grade, heavy duty ,XLPE insulated, armoured, complete laid in trenches/fixed to pole or laid under floor/drawn through pipe, with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Note : Excavation & earthwork for trenches, protection bricks/concrete blocks, MS Pipes/PVC Pipes with MS Clamps, bolts & nuts, washers etc, shall be measured and paid separately.
Supplying, laying, testing, connecting and commissioning under ground LT cable with aluminium stranded conductor, size 50Sqmm, 3.5core, 1100 Volts grade, heavy duty, XLPE insulated, armoured, complete laid in trenches/fixed to pole or laid under floor /drawn through pipe, with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Note : Excavation & earthwork for trenches, protection bricks/concrete blocks, MS Pipes/PVC Pipes with MS Clamps, bolts & nuts, washers etc shall be measured and paid separately.
Supplying, laying, testing, connecting and commissioning under ground LT cable with aluminium stranded conductor, size 16Sqmm, 4core, 1100 Volts grade, heavy duty, XLPE insulated, armoured, complete laid in trenches/fixed to pole or laid under floor /drawn through pipe, with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Note : Excavation & earthwork for trenches, protection bricks/concrete blocks, MS Pipes/PVC Pipes with MS Clamps, bolts & nuts, washers etc, shall be measured and paid separately.
Supplying, laying, testing, connecting and commissioning under ground LT cable with aluminium stranded conductor, size 16Sqmm, 2core, 1100 Volts grade, heavy duty, XLPE insulated, armoured, complete laid in trenches/fixed to pole or laid under floor /drawn through pipe, with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Note : Excavation & earthwork for trenches, protection bricks/concrete blocks, MS Pipes/PVC Pipes with MS Clamps, bolts & nuts, washers etc, shall be measured and paid separately.
Supply, installing, testing and commissioning, factory made & tested (CPRI approved), LT cubical panel board, minimum size 1.00mx0.75mx0.50m, outdoor type, suitable for 415Volts 3phase 4wire 50Hz AC supply, with a set of insulated aluminium bus bars 1000amp rating installed on porcelain /SMC insulators having bus bar chambers, dust and vermin proof with IP-65 protection, and made out of MS CRCA quality sheet 3.15mm thick, and 40mmx40mmx6mm angle iron base frame with 04Nos legs 75cm long made out of MS angle iron of size 40mmx40mmx6mm, legs embedded in PCC (1:2:4) having bottom of the panel at height of 45cm above ground level, duly powder coated finish over and including one coat of red oxide primer outside, and two coats of red oxide primer inside, front & rear openable with double door shutte fixed with hinges and locking arragements, with aprons for cable entry, internal wiring with PVC insulated solid copper conductor FRLS cable (IS-694 marked, 1100volts grade) of adequate size (min 4.0Sqmm) for power & 1.50 Sqmm multi strand copper conductor cable for internal connection of equipment. The scope of work comprising the following also:-
Supply, installing, testing and commissioning, factory made & tested (CPRI approved), LT cubical panel board, minimum size 1.00mx0.75mx0.50m, outdoor type, suitable for 415Volts 3phase 4wire 50Hz AC supply, with a set of insulated aluminium bus bars 600amp rating installed on porcelain /SMC insulators having bus bar chambers, dust and vermin proof with IP-65 protection, and made out of MS CRCA quality sheet 3.15mm thick, and 40mmx40mmx6mm angle iron base frame with 04Nos legs 75cm long made out of MS angle iron of size 40mmx40mmx6mm, legs embedded in PCC (1:2:4) having bottom of the panel at height of 45cm above ground level, duly powder coated finish over and including one coat of red oxide primer outside, and two coats of red oxide primer inside, front & rear openable with double door shutte fixed with hinges and locking arragements, with aprons for cable entry, internal wiring with PVC insulated solid copper conductor FRLS cable (IS-694 marked, 1100volts grade) of adequate size (min 4.0Sqmm) for power & 1.50 Sqmm multi strand copper conductor cable for internal connection of equipment. The scope of work comprising the following also:-
Supply, installing, testing and commissioning, factory made & tested (CPRI approved), LT cubical panel board, minimum size 0.75mx0.75mx0.40m, outdoor type, suitable for 415Volts 3phase 4wire 50Hz AC supply, with a set of insulated aluminium bus bars 400amp rating installed on porcelain /SMC insulators having bus bar chambers, dust and vermin proof with IP-65 protection, and made out of MS CRCA quality sheet 3.15mm thick, and 40mmx40mmx6mm angle iron base frame with 04Nos legs 75cm long made out of MS angle iron of size 40mmx40mmx6mm, legs embedded in PCC (1:2:4) having bottom of the panel at height of 45cm above ground level, duly powder coated finish over and including one coat of red oxide primer outside, and two coats of red oxide primer inside, front & rear openable with double door shutte fixed with hinges and locking arragements, with aprons for cable entry, internal wiring with PVC insulated solid copper conductor FRLS cable (IS-694 marked, 1100volts grade) of adequate size (min 4.0Sqmm) for power & 1.50 Sqmm multi strand copper conductor cable for internal connection of equipment. The scope of work comprising the following also:-
Supply and fixing, junction box / sheet metal enclosure, TPN, of size 210mmx310mmx116mm, out door type, made out of mild steel sheet 2mm thick, duly painted with two coats of synthetic enamel paint (internally & externally) over & including a coat of red oxide primer, and provision of hinged door with locking arrangements, and fixing to steel tubular pole etc., with 02 set(s) of clamps made out of flat iron 25mmx4mm, of adequate length, made to shape, fixed with suitable size MS bolts & nuts, washers etc., with provision of insulated aluminium bus bar 200Amp rating - 04 Nos mounted on porcelain insulators and MCB 10Amps, SPN, 240V, 50 Hz, 10 KA - 01 No, complete all as specified and directed.
Material and labour, earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically with top edge of earth plate not less than 1.5m below normal ground level (depth of pit not less than 2.25m below normal ground level), earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire 4mm dia (8SWG) by means of MS galvanised bolts & nuts, check nuts & GI washers, connected to main switch board or main control board or test point or equipment, protected by galvanized iron pipe light grade 15mm bore (ISI Marked), and watering pipe 20mm bore GI medium grade (ISI Marked of specified make) with funnel & wire mesh, including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover (in lieu of CI cover), all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and directed.
Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI wire earthlead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of eqpt and bldg, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the Mild steel identification board etc, shall be given by the Engineer-in-Charge. (vi) On completion of the entire work, the contractor shall submit a register/record showing location of earthing, earth value, date of testing, user`s signature etc to the Engineer-in-Charge. (vii) The work is to be carried out in replacement of existing earthing. The quoted rate shall be deemed to include for taking out, dismantling & disposal of metalic materials/components of old earthing and credit for retrieved metallic material shall be deducted as per 'Schedule of Credit'.
Material and labour, earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically with top edge of earth plate not less than 1.5m below normal ground level (depth of pit not less than 2.25m below normal ground level), earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mmx6mm thick by means of GI bolts, nuts, check nuts & GI washers or butt welding and other end of earth lead connected to main switch board or main control board or test point or equipment, earth lead protected by galvanized iron pipe light grade (ISI marked) 40mm bore, alongwith watering pipe 20mm bore GI medium grade (ISI marked of specified make), funnel with wire mesh, including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover (in lieu of CI cover), all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and directed.
Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed at least 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip earthlead and GI protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of eqpt and bldg, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the Mild steel identification board etc, shall be given by the Engineer-in-Charge. (vi) On completion of the entire work, the contractor shall submit a register/record showing location of earthing, earth value, date of testing, user`s signature etc to the Engineer-in-Charge. (vii) The work is to be carried out in replacement of existing earthing. The quoted rate shall be deemed to include for taking out, dismantling & disposal of metalic materials/components of old earthing and credit for retrieved metallic material shall be deducted as per 'Schedule of Credit'.
Material and labour, test point terminal block made of gun metal or phosphorus bronze or copper, size 75mmx75mmx25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws, complete all as specified and directed.
Supply and fixing, sheet metal enclosure distribution board, Vertical type, metallic, double door, company made, 3 phase 4 wire, 415 volts grade, 50Hz, 04 way, with 01 set of 200 Amps rating insulated copper bus bars of suitable size, mounted on Porcelain/SMC insulator, & PVC insulated copper jumpers from the MCCB to the outgoing circuits (one incoming MCCB & 12 out going MCBs circuits), including MCCB 160 Amp, 3 pole, 415 volts, 50Hz, 25KA, fixed Thermal & Magnetic setting - 01 No and MCBs 6-32 Amps, SP, 240 Volts, 10KA-12 Nos, complete all as specified and directed.
Supply, jointing & testing, straight through joint kit (Cold shrinkable) complete with jointing material and accessories suitable for 1.1KV (Earthed) grade, LT, 4 wire, underground XLPE insulated & armoured, aluminium conductor, 3.5 core, 25 to 50Sqmm size power cable, complete all as specified and directed.
Supply, jointing & testing, straight through joint kit (Cold shrinkable) complete with jointing material and accessories suitable for 1.1KV (Earthed) grade, LT, 4 wire, underground XLPE insulated & armoured, aluminium conductor, 3.5 core, 120 to 185 Sqmm size power cable, complete all as specified and directed.
Supply, jointing & testing, straight through joint kit (Cold shrinkable) complete with jointing material and accessories suitable for 1.1KV (Earthed) grade, LT, 4 wire, underground XLPE insulated & armoured, aluminium conductor, 3.5 core, 240Sqmm size power cable, complete all as specified and directed.
Supply and Fixing, Street Light fitting powder coated pressure die cast aluminium and compact, high power LED light 60 watt with heat resistant toughened glass with IP-66 protection and impact resistance of IK07 with 10KV built-in Surge Prorection device, complete all as specified and directed.
Supply and fixing, bracket 1.2m long made to shape (bend at 80/40cm) out of GI Pipe 40mm bore, medium grade, complete with two sets of fixing clamps made to shape out of MS flat 40mmx6mm of appropriate length, including MS bolts & nuts, washers etc, fixed to pole etc., complete all as specified and directed.
B & R Works
Excavation over area not exceeding 1.5 metre deep and getting out, in hard/dense soil, including dressing / trimming sides, levelling, grading bottom, and ramming of bottom of excavation, including watering, complete all as specified and directed.
Excavation in trenches, as in hard/dense soil, not exceeding 1.5m wide and not exceeding 1.5m in depth & not exceeding 10sqm on plan, for foundation etc., dressing/trimming sides and levelling/grading bottom surfaces, watering & well ramming to the required level/slope, complete all as specified and as directed.
Material and labour, plain cement concrete (1:4:8) type D-2, using 40mm graded crushed / broken stone aggregate as in foundation, filling & mass concrete, complete all as specified and directed.
Demolition of PCC (un-reinforced) in ground floors & paving n.exc 15cm thickness, below or above ground level, and removal of debris out side MoD land, complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including in quoins, pillars etc, and removal of serviceable bricks/ useful brick bats to store for reuse or credit, and the rubbish outside MoD land, complete all as specified and directed.
Material and labour, Brickwork with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius, built in Cement mortar (1:6), and external face of brick work pointed flush in the same mortar as the work proceeds, complete all as specified and directed.
Rough excavation, not exceeding 1.5m deep, and getting out, in hard/dense soil, complete all as specified and directed.
Material and Labour, hard core of broken stone of guage not exc 63mm, deposited, spread & levelled in layers not exceeding 15cm thick each, including watering and well ramming to a true surface, complete all as specified and directed. Note : Consolidated thickness shall be measured and paid accordingly.
Material and labour, sand filling under floors etc including watering and consolidation, complete all as specified and directed. Note :- Consolidated thickness shall be measured & paid accordingly.
Material and Labour, plain cement concrete (1:4:8) type D-2, using 40mm graded crushed stone aggregate, 75mm thick (consolidated thickness), as in sub-base of floors, finished fair and even, complete all as specified and directed.
Material and Labour, plain cement concrete (1:2:4) type B-1, using 20mm graded crushed stone aggregate, 100mm thick (consolidated thickness), as in floors, finished even and fair, complete all as specified and directed.
Material and Labour, machined pressed precast concrete interlocking paver blocks, any shape and size, confirming to IS-15658 of 2006, of 60mm thickness M-35 grade with grey cement and pigment, laid as in floors/ pavements over & including 25mm thick cushion (consolidated) layer of dry, clean and fine river sand including filling the joints with fine sand, complete all as specified and directed.
Note: The total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit (Rs. 46,190.00)
GULSHAN SINGH GHAI AND SON
kailu construction co
kapoor and co
R D Bansal
Santokh Singh and Associates
Raman Electric Trading Co
B S TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .