Loading…
Loading…
Tender Value
₹2.5 L
EMD Value
₹4,979
Closing Date
29 Sept 2026, 2:00 pm2d left
Executive Engineer
Executive Engineer University Works Department
Special repair to be carried out for 200 kva damage distribution transformer installed in boys hostel at Reasi Campus of University of Jammu
2026_UDJK_324633_1
enit 235 dated 09-9-2026
Open Tender
Electrical Works
Percentage
30 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹708
Executive Engineer University Works Department
₹4,979
29 Sept 2026
14 Sept 2026
30 Sept 2026
14 Sept 2026
29 Sept 2026
14 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Rewinding of 200 KVA rating of Distribution transformers with suitable size HV/LV New leg coil made of Copper Super Enamel Coil/DPC as per the requirement of original existing winding including Reconditioning painting the transformer with weather proof paint of approved brand as per IS code.disconnection and reconnection at site. after repair. | 135 | kg | 2,000 | ₹2,70,000 |
| 2 | S/F of HV bushing of following rating Distribution Transformer.
a. 200 kVA | 3 | Each | 150 | ₹450 |
| 3 | S/F of LV bushing of following rating Distribution Transformer.
a. 200 KVA | 4 | Each | 150 | ₹600 |
| 4 | S/F of HV bush Rod of following rating Distribution Transformer.
a. 200 KVA | 3 | Each | 200 | ₹600 |
| 5 | S/F of LV bush Rod of following rating Distribution Transformer.
a. 200 KVA | 4 | Each | 200 | ₹800 |
| 6 | S/Filling of Filtered Dehydrated Transformer oil. | 100 | Ltr. | 210 | ₹21,000 |
| 7 | Supply and installation of Copper Maintenance free Chemical Earthing System. Electrode size length 3000x dia 50mm with CU pipe Thickness 2.10mm. CU inner and terminal strip size 32x6mm with GSI backfill compound 2 No’s Bag (40-45kg) per Earthing. The Chemical Earthing system tested and certify/ recommended resistance value in normal soil 00.95 ohms max. decaying -0.02 per year, Conductivity as per IS 3043 Code including cost of 5 Rmt copper Strip. | 1 | Set | 20,000 | ₹20,000 |
| 8 | Shifting of 200kVA rating Distribution Transformer from Reasi Campus to Workshop in Jammu and Vice versa including transportation charges loading and unloading by crane in the campusand workshop | 1 | Set | 35,000 | ₹35,000 |
| 9 | Filtration and Dehydration of the existing Transformer Oil including filling in the repaired transformer | 170 | Ltr. | 50 | ₹8,500 |
| 10 | Deduct cost of material (copper scrap) Note:- The quoted percentage rates shal not be applicable on item No 10 of BOQ which shall be deducted in full from he bill of the contract. | 135 | kg | 800 | ₹1,08,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
BOQ_1095294.xls
BOQ • 0.30 MB
frst2355.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .