Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹16.9 L+₹93,685.70 (5.86%)Rejected-AOC | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 3 | L3₹17.7 L+₹1.7 L (10.4%)Rejected-AOC | L3 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 4 | L4₹23.5 L+₹7.5 L (47.0%)Rejected-AOC VARAD PLOT NO 11 DURGA NAGAR KAMATHWADE NASIK 422010 | NASHIK | MAHARASHTRA | 422010 | L4 | Rejected-AOC REJECTED DUE TO NOT LOWEST |
Tender Value
₹16.3 L
EMD Value
₹32,700
Closing Date
8 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
ADDN AND ALTERATION TO MCC BLDG TO ACCOMMODATE FRL PODS AND CERTAIN MINOR WORKS AT AF STN PUNE
2021_MES_421349_1
8426/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹32,700
Yes
24 Mar 2021
11 Feb 2021
10 Mar 2021
11 Feb 2021
8 Mar 2021
24 Feb 2021
60 days
Amount
Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and directed.
Demolition of concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (40mm graded stone aggregate ) for sub base 75mm thick complete all as specified and directed.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall and two corrugated side overlap fixed with ‘L’ type ‘j’ type or cranked hook bolt or with self taping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for machine cut Kota stone slabs flooring 20 to 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:4 complete all as specified and directed.
M&L for 20 to 25 mm thick kota stone slab in risers of steps, skirting, dado and pillar, laid over 10 mm thick cement screed in cement mortar 1:4 including rubbing and mirror polishing complete mixed with pigments complete all as specified and directed.
M & L for powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified
S&F Powder coated aluminium door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing, clips, rubber neoprene packing, handles 2 Nos in each door, hinges powder coated aluminium snap beading screws etc complete all as specified and directed.
S&F Powder coated aluminium windows and ventilators shutters fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading screws etc complete all as specified and directed.
Cutting holes into or through cement concret slabs, chajjas, etc reinforced or otherwise exc 250 Sq cm but not exc 500 sq cm all complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation / mass concrete complete all as specified and directed.
M&L 12mm size of mesh in wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples complete all as specified and directed.
S&F framed work such as grills guard bars and similar work conforming to Fe-290 grade complete all as specified and directed.
Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls exc half brick but not exc one brick complete all as specified and directed.
M&L for preparation of steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for prelaminated 12mm thick particle board , interior grade , prelaminated both sides with decorative choice laminations complete all as specified and directed.
S&F 5.5 mm thick sheet glass ordinary quality and glazing with oil putty in square exc.0.5 sq m each pane complete all as specified and directed.
S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putty in square exc.0.5 sq m each pane complete all as specified and directed.
M&L for aluminium mortice lock , vertical type size 75mm 4 levers complete all as specified and directed.
complete removal of existing treatment from walls and apply two coats of oil bound distemper over a coat of clearcolle on plastered or other surfaces preparatory to distempering complete all as specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and directed.
One light point controlled by one switch .
One Fan point controlled by one regulator/switch.
One 3 pin socket 5 A on independent board.
One 3 pin socket 5 A on the same switch board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) for housing one 15 A Switch / sockets complete all as specified and directed.
Supply and fix ceiling rose surface type bakelite / PVC three terminal 65 x 50mm complete all as specified and directed.
Supply and fix switch piano flush type 5 Amp one way complete all as specified and directed.
Supply and fix switch piano flush type 15 A one way complete all as specified and directed.
Supply and fix Socket out let 2in 1, 5 pin 5 Amp complete all as specified and directed.
Supply & fix Socket outlet 2 in 3 pin 5 and 15 Amp flush type complete all as specified and directed.
M & L for sub main wiring with two runs of single core 10.0Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping complete all as specified and directed. ( Note:-Two runs of 10 Sqmm copper cable & one run of 6 sqmm copper cable including PVC casing & caping shall be measured & paid as one length )
Supply and fix high quality indoor Surface and wall mounted LED batten 20 Watt, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal complete all as specified and directed. Make : Havells, Model: Lumiline Plus LED Cat part No: LUMILINEPLUSBS20WLED865SPCSS or equivalent in CG/Philips/Bajaj
Supply and fix Energy efficient recess mounted LED panel fitting 34 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 3300/4000K colour temperature with current electronic connections complete all as specified and directed. Make Havells, Model: Venus Neo HE PRI Cat part No: VENUSNEOHE2X2R34WLED840PIRSENSOR or equivalent in CG/Philips/Bajaj
S&F wall mounted fan 400 mm sweep with complete wiring and other fixing accessories as per requirement on site complete all as specified and directed.
S&F 450 mm sweep Heavy duty Metal Exhaust fan with louvers, 1400 RPM with complete wiring and other fixing acessories as per requirement on site complete all as specified and directed.
M&L for cutting wall for exhaust fan opening , the cutting mist be of suitable dimension to accommodate the exhaust fan and make good surface finish with cement plaster work complete all as specified and directed.
S&F TPN DB 8 way with 200 amps bus bar double door type made out of sheet metal enclosure dust and vermin proof 4 way IP 54 complete all as specified and directed. Make Havells/Legrand/ABB/LT
M&L for MCB Four Pole 100 amps C curve and electric connections with copper thimbles complete all as specified and directed.
M&L for MCB Four Pole 40 amps C curve and electric connetions with copper thimble complete all as specified and directed.
M&L for MCB SP 6-32 Amps C curve and electric connections with copper thimbles complete all as specified and directed.
M&L for fixing of copper strip of size 20mmx3.15 mm with saddles crews etc on laminar table and connected it to the earth test point complete all as specified and directed.
M&L for supply, installation, testing and commissioning of pure copper pipe electrode earthing maintenance free earthing sabes on 3 mtr long copper pipe 80 mm dia (ID) copper strip 32x6 mm (Strip in pipe tpe electrode) and copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the copper pipe electrode rate included for testing, commisioning including checking of earth continuity and earth result complete all as specified and directed, copper strip required for interconnection copper electrode to test point must be laid 2 ft below the ground level and the same must be treated with chemical (BFC). Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore The resistance value of earthing must be less than 1 ohm, to get the desired result grid of 2 or 3 earthing shall be done . Continuity of good earth resitance shall maintained upto 1 year and testing will be carried out monthly by MES authority. Copper strip must be connected with copper pipe electrode through brazing & brass nut Bolts. Note. (i) Earth strip from top connector of electrode to test point and further connection to LT Panel/AF equipment/for grid of earthing shall be measured and paid separately. (ii) The resistance value of earthing must be less than 1 ohm, the cost of any etra work required to achieve the result ust be included in the quoted rate.
M & L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 1991 & testing complete including 15mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GI watering pipe etc. complete all as specified and directed.
S&F Copper earth continuity conductor or main earthing lead of size 25x3 mm fixed to wll on batten or recess or cheses or buried in bround or drawn in conduit/pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed.
S&F epoxy insulators suitable of aluinium strip of 25x3 mm size with nut bolt/screws for fixing of copper /aluminum/GI Strips on stone/PCC block wall etc.complete all as specified and directed.
M&L for earthing chamber of size 450x450x300 mm depth outside & 250x250x300 mm depth inside of PCC (1:3:6) type C1 complete all as specified and directed.
S&F of PVC trunk of size 150 mmx100 mm along the wall including all necessary fixing accessories complete all as specified and directed.
Supply laying testing in replacement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty with stranded aluminium conductor 1100 volts grade of 50 sqmm 3.5 core complete all as specified and directed.
S&F of bus bar panel indoor type single door type made out of sheet metal enclosure dust and vermin proof IP 54 of size 18 inchesx18 inches, consist of aluminium bus bar of 200 amps capacity of RYB & N with multiple holes in the bus bar for incoming and outgoing cables, the panel to be fixed on wall using necessary fastners nuts bolts etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 mtr in depth for foundation, laying pipe line etc. and getting out in complete all as specified and directed. :-
Soft/Loose soil
Hard/dense soil
Soft / disintegrated rock
Returning , filling in trenches including spreading levelling watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M & L for dry screened river bed sand cushioning 8cm before laying the cable and 15cm after laying the cable and further hand punned to form a uniform a uniform layer of 18cm complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and directed.
Supply, install, testing commissioning of 5 Star rated inverter AC having 2.0 TR Capacity, precision cooling technology, dual rotor invertor compressor , BLDC motor, filters, cold plasma technology, 100 % copper coils of inddor, outddor including installation kit for inddor & outdoor unit, extra length of refrigrent copper piping, coard cable, drain pipe as red at site, including necessary core cutting as reqd at site. Refrigrent shall be echo friendly (R-410a, R-32)
Supply only of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150V to 285V with accuracy of 2+2.5 and of capacity 5 KVA 15 Amps
M&L for Sheet metal enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts all as specified and directed.
M & L for sub main wiring with two runs of single core 4.0 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping complete all as specified and directed.
S & F flame proof fluroscent tube light fitting. 1 x 36 watt of type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.
S&F flame proof rotary type switch with termination box in LM6, 16A, single pole 230 Volts complete all as specified and directed.
M & L for point wiring with two runs of 1.5 Sq mm single core PVC insulated sheathed multistranded copper conductor FRLS cable 1100 volts grade drawn throughh and incuding ERW steel conduit 25 mm dia (External) flame proof and FLP conduit accessories including 1.5 mm PVC insulated & PVC sheathed multistranded copper conductor FRLS cable 1100 volts grade as earth continuity for light/fan point complete all as specified and directed.
Supply & Fixing flame proof single phase exhaust fan 380mm 15" 230 volts, 1440RPM, Cat pt No EF/140, including louver, including making hole in existing wall for fixing the fan making good the disturbed surface complete all as specified and directed. Make Sudhir/Shyam
M & L for point wiring with two runs of 4 sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 4 sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC conduit with all fittings/fixtures etc. complete all as specified and directed.
M & L Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one double pole MCB 32 A complete all as specified and directed.
RANJANA CONSTRUCTIONS
Saiprabha Construction
Samruddhi Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .