| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC FLAT NO 1 SAMATA CHS SECTOR NO 7 SHREENAGAR THANE W 400604 | THANE | MAHARASHTRA | 400604 | ₹1.6 Cr Quoted ₹1.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.4 Cr+₹7.0 L (5.28%)Rejected-Finance | ₹1.4 Cr+₹7.0 L (5.28%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹1.6 Cr+₹22.5 L (17.0%)Rejected-Finance SHOP NO 2 KAMOTHE ANIRRUDHA HEIGHT KAMOTHE PLOT NO 168 VILLAGE TOWN SECTOR 34 CITY NAVI MUMBAI RAIGAD MAHARASHTRA 410209 INDIA | RAIGAD | MAHARASHTRA | 410209 | ₹1.6 Cr+₹22.5 L (17.0%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹1.6 Cr+₹24.8 L (18.6%)Rejected-Finance 1ST FLOOR MALVIYA NAGAR CEG MALVIYA INDUSTRIAL AREA B 11 G VILLAGE TOWN JAIPUR CITY JAIPUR JAIPUR RAJASTHAN 302017 INDIA | JAIPUR | RAJASTHAN | 302017 | ₹1.6 Cr+₹24.8 L (18.6%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹1.7 Cr+₹34.8 L (26.2%)Rejected-Finance 11 13 39 RD NO 3 GREEN HILLS COLONY SAROORNAGAR HYDERABAD TELANGANA 500035 | RANGA REDDY | TELANGANA | 500035 | ₹1.7 Cr+₹34.8 L (26.2%) | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | Jay Gajanan Geotechnics L12 | BECQUEREL INDUSTRIES PVT. LTD. L7 | Genstru Consultants Pvt. Ltd. L5 | MYRTLE PROJECT AND CONSULTANCY PRIVATE LIMITED L12 | Geo Designs and Research Pvt Ltd L4 | MNEC CONSULTANTS PRIVATE LIMITED L10 | M/s. S and R Geotechniques Pvt.Ltd. L2 | C E Testing Company Pvt. Ltd. L9 | CEG Test House And Research Centre Pvt. Ltd. L3 | Fugro Geotech Pvt. Ltd. L6 | AECS ENGINEERING & GEOTECHNICAL SERVICES PVT. LTD. L13 | Manglam Consultancy Services Hyderabad L12 | S.M. Consultants Private Limited L11 | RENUKA CONSULTANTS (EXPLORERS AND DESIGNERS) PRIVATE LIMITED L1 | GEOSERVICES MARITIME PVT LTD L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | PART A-Section (I) Field Tests on Rock/ Soils.Clearing Jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings and removal of rubbish up to a distance of 50 m / outside the periphery of the area cleared as per specifications to facilitate geotechnical investigation and as directed by the Engineer-in-charge.
(Note : Area required for investigation alone to be cleared and will be measured for payment) | 6,700 | SqM | 6 ₹40,200 | 14 ₹93,800 | 19 ₹1,27,300 | 16 ₹1,07,200 | 15 ₹1,00,500 | 40 ₹2,68,000 | 15 ₹1,00,500 | 10 ₹67,000 | 100 ₹6,70,000 | 22 ₹1,47,400 | 40 ₹2,68,000 | 119 ₹7,97,300 | 5 ₹33,500 Lowest | 30 ₹2,01,000 | 65 ₹4,35,500 |
| 2.00 | Mobilisation and demobilisation of suitable boring plant and all other allied equipments like Minimum 2 boring rigs or as required number of boring rigs to complete the job in time, survey equipments and all other insitu tests equipments and manpower required to complete the scope of this work. | 1 | Job | 3,00,124 ₹3,00,124 | 1,75,000 ₹1,75,000 | 2,50,000 ₹2,50,000 | 2,51,903 ₹2,51,903 | 1,00,000 ₹1,00,000 Lowest | 3,00,000 ₹3,00,000 | 2,50,000 ₹2,50,000 | 7,50,000 ₹7,50,000 | 3,00,000 ₹3,00,000 | 4,50,000 ₹4,50,000 | 2,50,000 ₹2,50,000 | 20,70,018 ₹20,70,018 | 2,00,000 ₹2,00,000 | 5,00,000 ₹5,00,000 | 4,00,000 ₹4,00,000 |
| 3.00 | Setting up of boring rig at each location, only once for each borehole location including moves between borehole position greater than 5 M locating and marking the location on the ground by actual survey, setting up all field test equipments and bringing all personal to the location, making area good for setting up rig etc. complete. | 26 | Nos | 4,550 ₹1,18,300 | 5,000 ₹1,30,000 | 2,000 ₹52,000 Lowest | 3,079 ₹80,054 | 2,500 ₹65,000 | 5,000 ₹1,30,000 | 10,000 ₹2,60,000 | 7,500 ₹1,95,000 | 3,500 ₹91,000 | 7,500 ₹1,95,000 | 5,000 ₹1,30,000 | 2,384 ₹61,984 | 5,000 ₹1,30,000 | 22,500 ₹5,85,000 | 7,000 ₹1,82,000 |
| 4.00Boring vertically through all kinds of soils, weathered rock and soft rock, boulders, if any met during drilling with suitable and adequate equipment as required for the depth as measured below existing ground level.Note:(1) RQD of 10% and less will be considered as weathered/soft rock. (2) The soft or weathered rock underlying hard rock with thickness greater than 0.5 M will be considered as soft or weathered rock. (3) Core recovery of 20% and less also considered as soft rock at appropriate depth. 4) Bore holes , location, depth as specified in the drawing and as specified by Engineer in charge. | ||||||||||||||||||
| 4.10 | 0 m to 10 m. From G.L | 310 | RM | 3,000 ₹9,30,000 | 2,200 ₹6,82,000 | 2,500 ₹7,75,000 | 1,355 ₹4,20,050 | 2,000 ₹6,20,000 | 3,000 ₹9,30,000 | 2,000 ₹6,20,000 | 2,250 ₹6,97,500 | 2,000 ₹6,20,000 | 2,010 ₹6,23,100 | 2,500 ₹7,75,000 | 1,430 ₹4,43,300 | 3,000 ₹9,30,000 | 2,250 ₹6,97,500 | 1,000 ₹3,10,000 Lowest |
| 4.20 | 10 m to 20 m from G.L. | 310 | RM | 3,000 ₹9,30,000 | 2,200 ₹6,82,000 | 2,500 ₹7,75,000 | 1,517 ₹4,70,270 | 2,000 ₹6,20,000 | 3,200 ₹9,92,000 | 2,200 ₹6,82,000 | 2,450 ₹7,59,500 | 2,500 ₹7,75,000 | 2,010 ₹6,23,100 | 2,500 ₹7,75,000 | 1,550 ₹4,80,500 | 3,500 ₹10,85,000 | 500 ₹1,55,000 Lowest | 1,050 ₹3,25,500 |
| 4.30 | 20 m to 30 m from G.L. | 310 | RM | 3,000 ₹9,30,000 | 2,500 ₹7,75,000 | 2,800 ₹8,68,000 | 1,595 ₹4,94,450 | 2,000 ₹6,20,000 | 3,400 ₹10,54,000 | 2,300 ₹7,13,000 | 2,650 ₹8,21,500 | 2,500 ₹7,75,000 | 2,010 ₹6,23,100 | 2,500 ₹7,75,000 | 1,669 ₹5,17,390 | 4,000 ₹12,40,000 | 10 ₹3,100 Lowest | 1,100 ₹3,41,000 |
| 4.40 | 30 m to 40 m from G.L. | 135 | RM | 3,000 ₹4,05,000 | 3,000 ₹4,05,000 | 2,800 ₹3,78,000 | 1,663 ₹2,24,505 | 2,000 ₹2,70,000 | 3,600 ₹4,86,000 | 2,500 ₹3,37,500 | 2,850 ₹3,84,750 | 2,500 ₹3,37,500 | 2,010 ₹2,71,350 | 2,500 ₹3,37,500 | 1,788 ₹2,41,380 | 4,500 ₹6,07,500 | 10 ₹1,350 Lowest | 1,150 ₹1,55,250 |
| 4.50 | 40 m to 50 m from G.L. | 30 | RM | 3,000 ₹90,000 | 4,600 ₹1,38,000 | 2,800 ₹84,000 | 1,691 ₹50,730 | 2,000 ₹60,000 | 3,800 ₹1,14,000 | 2,500 ₹75,000 | 3,100 ₹93,000 | 2,500 ₹75,000 | 2,010 ₹60,300 | 2,500 ₹75,000 | 1,907 ₹57,210 | 5,000 ₹1,50,000 | 10 ₹300 Lowest | 1,200 ₹36,000 |
| 5.00Drilling vertically through bedrock strata (Hard rock), using Nx size diamond bit, using double tube core barrel with suitable core catcher, including collection and logging of cores, placing them in approved wooden core boxes made up of 25mm thick planks with partitions of 12mm thick as per relevant IS with a coat of Anti Termite chemical in a proper sequence, numbering each core, noting the lithology, colour photographs (100X150mm size) of rock cores, locking arrangements, labeling and transporting the boxes to core store/laboratory as directed by EIC etc., all as per specifications for the following depths measured from existing ground level :Note:(1) RQD of 10% and less will be considered as weathered/soft rock. (2) The soft or weathered rock underlying hard rock with thickness greater than 0.5 M will be considered as soft or weathered rock. (3) Core recovery of 20% and less also considered as soft rock at appropriate depth. 4) Bore holes , location, depth as specified in the drawing and as specified by Engineer in charge. | ||||||||||||||||||
Tender Value
₹2.0 Cr
EMD Value
₹4.7 L
Closing Date
6 Feb 2025, 3:00 pmClosed
Chief Engineer
CED, BARC, Mumbai.
Geotechnical investigation for Rain water harvesting, Proposed Administrative Complex, New CAP building, LINAC Facility near Field House Gamma Field and Geophysical Investigation near UED and other locations inside BARC, Trombay Mumbai.
2024_BARC_838143_1
BARC/CED/ET/40/2024-2025 Dated 04/12/2024
Open Tender
Civil Works
Item Rate
365 days
BARC, Trombay Mumbai.
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹4.7 L
CED, BARC, Mumbai.
10 Sept 2025
6 Dec 2024
11 Feb 2025
6 Dec 2024
6 Feb 2025
2 Jan 2025
6 Dec 2024 - 16 Dec 2024
17 Dec 2024
Amount
PART A-Section (I) Field Tests on Rock/ Soils.Clearing Jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings and removal of rubbish up to a distance of 50 m / outside the periphery of the area cleared as per specifications to facilitate geotechnical investigation and as directed by the Engineer-in-charge. (Note : Area required for investigation alone to be cleared and will be measured for payment)
Mobilisation and demobilisation of suitable boring plant and all other allied equipments like Minimum 2 boring rigs or as required number of boring rigs to complete the job in time, survey equipments and all other insitu tests equipments and manpower required to complete the scope of this work.
Setting up of boring rig at each location, only once for each borehole location including moves between borehole position greater than 5 M locating and marking the location on the ground by actual survey, setting up all field test equipments and bringing all personal to the location, making area good for setting up rig etc. complete.
Boring vertically through all kinds of soils, weathered rock and soft rock, boulders, if any met during drilling with suitable and adequate equipment as required for the depth as measured below existing ground level.Note:(1) RQD of 10% and less will be considered as weathered/soft rock. (2) The soft or weathered rock underlying hard rock with thickness greater than 0.5 M will be considered as soft or weathered rock. (3) Core recovery of 20% and less also considered as soft rock at appropriate depth. 4) Bore holes , location, depth as specified in the drawing and as specified by Engineer in charge.
0 m to 10 m. From G.L
10 m to 20 m from G.L.
20 m to 30 m from G.L.
30 m to 40 m from G.L.
40 m to 50 m from G.L.
Drilling vertically through bedrock strata (Hard rock), using Nx size diamond bit, using double tube core barrel with suitable core catcher, including collection and logging of cores, placing them in approved wooden core boxes made up of 25mm thick planks with partitions of 12mm thick as per relevant IS with a coat of Anti Termite chemical in a proper sequence, numbering each core, noting the lithology, colour photographs (100X150mm size) of rock cores, locking arrangements, labeling and transporting the boxes to core store/laboratory as directed by EIC etc., all as per specifications for the following depths measured from existing ground level :Note:(1) RQD of 10% and less will be considered as weathered/soft rock. (2) The soft or weathered rock underlying hard rock with thickness greater than 0.5 M will be considered as soft or weathered rock. (3) Core recovery of 20% and less also considered as soft rock at appropriate depth. 4) Bore holes , location, depth as specified in the drawing and as specified by Engineer in charge.
0 m to 20 m. From G.L
20 m to 40 m. From G.L
40 m to 50 m from GL
Obtaining 90 mm diameter, 450 mm long undisturbed soil samples (UDS ) from boreholes WITH JARRING LINK in soil, soft and weathered rock and collecting packaging and labeling.
Conducting Standard Penetration Tests (SPT) in soil, soft and weathered rock and collecting, packaging and labelling disturbed soil/rock samples there from all as per IS:2131-1981(reaffirmed in 2002).
Conducting Standard Penetration Tests (SPT) as in Item No. 7 above but with part of the distrubed soil samples of medium stiff to hard cohesive soils to be coated with paraffin wax and sealed immediately on collection to completely retain all moisture within the sample, and part of the sample to be collected, packaged and sealed as in item No. 7 above.
Conducting SPT in rock with RQD greater than 10% and less than 25% all as per specifications, including replacement of SPT shoe by a new SPT shoe for each SPT as per specifications.
Collection of ground water samples for evaluation of ground water level and their variation as per IS:1892-1979 (reaffirmed in 2002), IS:6935-1973 (reaffirmed in 2012) from each borehole at specified depths (minimum 1 litre) including all provisions of sampling, packing, sealing and labeling as specified and including handling charges etc. all as per specifications.
Conducting cross borehole test comprising of five boreholes, one source and four receiver bore holes (two in X-direction and two in Y-direction) for evaluation of Dynamic modulli ,dynamic Poisson's ratio,shear and compression wave velocity variation with depth . The test shall be conducted as per IS 13372(Part 2):1992 (reaffirmed in 2001),ASTM:D4428,ASTM:D7400 at specified location and depth as per direction of EIC excluding cost of drilling of appropriate size bore holes required for test upto 50 m depth, which will be paid under relevant Item No.4 and 5 of this bill of quantity, PVC/Aluminum pipe casing, grouting and backfilling complete as per specifications and as directed by Engineer-in-charge.
Backfilling of boreholes with 1:1 cement : bentonite/ mud grout as per specification. Operating of this item is must for satisfactory completion of work.
Conducting Plate Load Test ( asper IS: 1888-1982 reaffirmed 2007) at foundation level using 600mm x 600mm test plate including cost of excavation, dewtering, all arrangement for reaction loading, testing depth, all as per the specifications and as directed by Engineer in Charge.
Upto 5.00 Metre depth level.
Carrying Electrical resistivity test for evaluating ground water level and its variation along with subsurface stratification,ground profiling by Schlumberger four electrode method including submission of comprehensive report with interpreted results for layer thickness and resistivities in triplicate. The test is to be conducted as per IS:1892 -1979(Reaffirmed in 2002), IS:15736-2007(Reaffirmed in 2012) covering whole plan area of building upto depth of exploration as specified & recommended by Engineer in charge below existing ground level.
Carrying out Core cutter method (CCM) test (for fine grained cohesive soils) as per IS:2720(Part XXIX)-1975 (Reaffirmed 2005) to evaluate Bulkdensity,dry density.The test is to be conducted on one or more UDS(undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Carrying out Sand replacement method test (for medium&coarse grained soil) as per IS:2720(Part XXVIII)-1974 (Reaffirmed 2010) to evaluate Bulkdensity,dry density.The test is to be conducted on one or more DS(disturbed sample )collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Conducting Pressure meter test in NX size borehole in soft rock & hard rock with electronic probe for pressure up to 200 bar or failure which occures earlier and submitting the test data and computed parameters (like Em,PL,Creep etc.)as per IS12955(Part-2)1990 reaffirmed in 2001. at specified bore holes .( One set of test consistes of testing at 4 elevations in boreholes)
At depth corresponding to RQD-25%
At depth corresponding to RQD-50%
At depth corresponding to RQD-75%
Carrying out Sand bath method Alcohol Method test as per IS:2720 (Part II)-1973 (Reaffirmed 2010) to evaluate Water content .The test is to be conducted on one or more DS (disturbed sample )collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC.
Section II -Laboratory tests on Soil Determination of Grain size distribution,percent fines of soil sample by conducting Grain Sieve analysis & Hydrometer analysis as per IS:2720(PART 4) -1985(Reaffirmed in 2006) . The test is to be conducted on one or more DS(disturbed sample ) & UDS (undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Sieve analysis.
Hydrometer or Pipette analysis
Determination of soil classification,identification, evaluating percent fines as per IS:1498-1970(Reaffirmed in 2007). The test is to be conducted on one or more DS(disturbed sample) & UDS(undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC, submission of test result as directed by EIC.
Determination of Specific gravity, natural moisture content, voids ratio by conducting Density bottle method , Pycnometer method test as per IS2720(Part III/Sec1 or Sec2 )-1980 (reaffirmed in 2002)along with submission of test result as directed by EIC. The test is to be conducted on one or more DS(disturbed sample ) &UDS(undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Water content from UDS by oven drying method as per IS : 2720(Part II) - 1973.
Determination of Liquid limit, plastic limit atterberg limits and plasticity index of soil sample as per IS: 2720 (part5)-1985 Reaffirmed in 2006. The test is to be conducted on one or more DS(disturbed sample ) &UDS(undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Determination of Shrinkage limit and shrinkage ratio of soil sample as per IS: 2720 (part-VI)-1972 Reaffirmed in 2001. The test is to be conducted on one or more DS(disturbed sample ) &UDS(undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Carrying out Chemical analysis of sub soil samples to evaluate chemical characteristics of soil including pH,Sulphates(SO3&SO4),chloride and nitrate contents,organic matter, chemicals salinity and any other chemicals harmful to the foundation material as per IS: 2720 (Part 23,24,25,26 and 27) in an approved laboratory, complete as per specifications, including submission of test report .The test is to be conducted on one or more DS(disturbed sample) &UDS(undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Same as in Item No. 25 above, but on 2:1 water:soil extract of the soil samples, giving sulphates as SO3 only.
Chemical analysis of sub-soil, ground water&soil-water mixture as per relevant IScodes for determining chemical characteristics of water&soil such as colour,odour,turbidity ,pHvalueand specific conductivity at 25deg.Cand chemical contents such as carbonates,sulfates (both SO3and SO4), chlorides,nitrates,organic matter and any other chemical harmful to the foundation material . The test is to be conducted on one or more water samples collected from each borehole. water samples, including alkalinity sulphates as SO3 & SO4, chlorides, Nitrates, pH, turbidity, flouride, free and saline ammonia content, hardness etc., organic content ,soluble salt content and any other chemical & harmful chemicals . etc
Conducting In-situ Pump-in Permeability test by double packer cyclic method in weathered and hard rock of 3m test section upto maximum presssure of 10Kg/sq.cm,all as per IS: 5529 (Part 2)-2006 to evaluate permeability.Each unit of this item shall consist of a series of tests with pressure of three(3) equal increments to the maximum and three(3) equal decrements etc., as per specifications. The test is to be conducted in specified boreholes at specified depths as per direction of EIC.
Carrying out Direct Shear Test (UU,CU,CD) (for cohesionless soil) as per IS:2720 (Part 13)-1986 (Reaffirmed 2002) to evaluate Cohesion and Angle of internal friction (CD test), Shear Strength, Shear Modulus (Static), ELastic Modulus (Static) Coeficient of Consolidation (for CD test) .The test is to be conducted on one or more UDS (undisturbed sample ) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC.
Cohesion and Angle of internal friction
Shear Strength
Shear Modulus
Elastic Modulus
Coeficient of Consolidation
Triaxial compressive Strength Test on undisturbed soil samples or on soil samples compacted to specified density on cohesive as well as cohesionless soil. Tests to be conducted asper IS:2720 (Part11)-1993 (Reaffirmed in 2002).
Unconsolidated Undrained
Consolidated Undrained, including bore water pressure measurement
Unconfined compressive strength test as per IS: 2720 (Part10) 1991 (Reaffirmed in 2006) on undisturbed soil samples or soil samples compacted to specified density to determin safe bearing capacity, compressive & shear strength of soil.
Consolidation tests on undisturbed soil samples or on soil samples compacted to specified density, giving full test results including unit weights, specific gravity, e-log p curve, virgin curve, P0, eo, Cc, Cv and mv for all pressure increments etc. (Tests without presentation of these results will not be paid for.)
Carrying out Proctor Density Test as per IS:2720 (Part 7)-1980 to evaluate Bulk density, Dry Density, Optimum Moisture Content. The test is to be conducted on one or more DS (undisturbed sample ) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Evaluation of Liquefaction Potential based on the other tests conducted in laboratory on undisturbed or remoulded samples of soil. ' NOTE: The UDS shall correspond to each soil stratum. Hence can be decided only after receipt of borelog data. Test to be done in each or alternate boreholes and 2 samples assumed per borehole.and as decided by the design Engineer.
Section (III) Laboratory tests on Rock Carrying out petrographic examination of rock sample as per ASTM: C-295 for determination of core recovery, rock quality designation and rock mass rating in each borehole, for each rock stratum and submission of test result as directed by EIC.
Determination of water content, Porosity and density [saturated surface dry &wet condition], specific gravity by conducting Caliper,Buoyancy,Mercury Displacement techniques as per IS: 13030-1991(Reaffirmed 2001) . The test is to be conducted on one or more rock sample representative of each rocky stratum collected from each borehole.
Conducting Water absorption test as per IS: 1124-1974( Reaffirmed 2003) to evaluate water absorption . The test is to be conducted on one or more RS representative of each rocky stratum collected from each/alternate borehole.
Carrying out Unconfined compression strength (UCS) test on soaked & unsoaked samples for determination of Poisson's ratio,modulus of elasticity ,shear modulus as per IS:9221-1979(reaffirmed 2001)along with unconfined compressive strength,safe bearing pressure of rock sample as per IS: 9143-1979(reaffirmed2001)in each borehole and submission of test result as directed by EIC.
without saturation
with atleast 7 days saturation
Brazilian test on rock core as per IS:10082-1981 (Reaffirmed 2001)to evaluate tensile strength, in boreholeand submission of test result as directed by EIC.
Detremination of Safe bearing pressure by conducting Point load strength test of rock sample as per IS:8764 - 1998 (reaffirmed 2008) & IS:10082 - 1981 (reaffirmed 2001) in each borehole at 3.0m,6.0m,9.0m,12.0m,15.0m, 18.0m,21.0m,24.0m,27.0m,30.0m and submission of test result as directed by EIC.
Carrying out triaxial compression test for determination of triaxial compressive strength, cohesion and angle of internal friction as per IS:13047-1991(reaffirmed 2010) along with modulus of elasticity, stress-strain behavior as per ISRM- SM 1983 ,ASTM:D2664 and submission of test result as directed by EIC.
Construction of pillars at as directed in Brick work in CM 1:5 of size 345 mm X 345 mm with plain cement concrete of 1:5:10 base coarse of 100 mm thick. Brick work shall be 200 mm height below ground level and 400 mm height above ground level .Top surface of the pillar shall be plaster with CM 1:5 12 mm thick with floating coat of neat cement slurry and marking the co-orinates in paint. The rate includes required earth work etc complete .The work shall be as per specification and as per direction of Engineer in charge
Section (IV) Reports 'Preparation and submission of Three (3) hard & soft copies(on DVD) of Draft reports as specified followed by Five (5) hard copies of Final report of Geotechnical Investigations as detailed in specifications along with 6 soft copies of the same on the DVD. 'Note: 1. Final Report to be submitted shall include recommendations for the geotechnical investigation consisting of deliverables as per FORMAT - 2 which will be issued to the successful bidders. '2. Geotech Investigations for Soils and Rock will be carried out to evaluate the different type of test values as per FORMAT - 1 which will be issued to the successful bidders.
PART-B-Geophysical Investigation: Conducting streaming potential method consists of measuring the electrical potential by flowing water within a structure or subsurface till existing Aquifer. The tests at each locations shall be conducted as a series of tests with appropriate electrodes array. All as per the specification and as directed by Engineer. Setting up equipment at each location including moves between positions, locating and marking the location on the ground by actual survey (by using precision position instruments such as GPS and Total Station), setting up all field test equipment, making area good for setting up etc.
The report should provide a clear explanation of the data interpretation methodology, including how raw data was processed and any assumptions made. All raw and interpreted data, including measurements and test results, must be provided in a readable digital format, along with any supporting data files. It should summarize the key findings, such as the groundwater table depth, direction of groundwater flow, and aquifer characteristics, supported by relevant charts, tables, and visual aids. The report must also include an analysis of the groundwater table depth at the subject site, based on field measurements or other reliable data sources, and determine the direction of groundwater flow using appropriate hydrological methods. Additionally, the report should outline the experimental procedures used to assess the aquifers' hydrological parameters, including the instruments and techniques for data collection, as well as the steps taken to analyze groundwater movement, permeability, and storage properties.
M/s. S and R Geotechniques Pvt.Ltd. (BID ID -3162649)
CEG Test House And Research Centre Pvt. Ltd. (BID ID -3162936)
Geo Designs and Research Pvt Ltd (BID ID -3161175)
Genstru Consultants Pvt. Ltd. (BID ID -3156302)
Fugro Geotech Pvt. Ltd. (BID ID -3162982)
BECQUEREL INDUSTRIES PVT. LTD. (BID ID -3154310)
GEOSERVICES MARITIME PVT LTD (BID ID -3150485)
C E Testing Company Pvt. Ltd. (BID ID -3156400)
MNEC CONSULTANTS PRIVATE LIMITED (BID ID -3162463)
S.M. Consultants Private Limited (BID ID -3160785)
MYRTLE PROJECT AND CONSULTANCY PRIVATE LIMITED (BID ID -3158256)
Manglam Consultancy Services Hyderabad (BID ID -3152237)
Jay Gajanan Geotechnics (BID ID -3152719)
AECS ENGINEERING & GEOTECHNICAL SERVICES PVT. LTD. (BID ID -3161694)
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .