| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC | ₹36.5 L Quoted ₹37.6 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹37.8 L+₹18,110 (0.48%)Rejected-AOC 1ST FLOOR GURJEET MARKET DHANGU ROAD | ₹37.8 L+₹18,110 (0.48%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹37.8 L+₹18,136 (0.48%)Rejected-AOC C O ANU REFRIGERATION WORKS GANDHI CHOWK PATHANKOT GANDHI CHOWK PATHANAKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | ₹37.8 L+₹18,136 (0.48%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹38.1 L+₹42,300 (1.12%)Rejected-AOC | ₹38.1 L+₹42,300 (1.12%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹38.8 L+₹1.1 L (2.94%)Rejected-AOC | ₹38.8 L+₹1.1 L (2.94%) | L5 | Rejected-AOC Rejected |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
11 Nov 2021, 6:00 pmClosed
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun PIN-145001
REPAIR/MAINTENANCE OF MCBS, DB, METER BOX, MCCB, CONNECTED CABLES, EARTHING, AIR TERMINATION RODS, CONNECTED STRIPS, EARTHING FOR LIGHTENING PROTECTION AND OTHER E/M WORKS UNDER AGE E/M-I AT MAMUN
2021_MES_476728_2
GE(N)/M-39/2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹86,000
13 Jan 2022
28 Oct 2021
13 Nov 2021
28 Oct 2021
11 Nov 2021
28 Oct 2021
Amount
Taking down carefully old burnt MCB DBs SPN/VTPN including MCCBs/MCBs by disconnecting from copper/aluminium wiring and saggregating serviceable and unserviceable MCBs complete and removing materials to store for keeping in safe custody for reusing serviceable items or taking credit of unserviceable items and making good disturbed surfaces of walls, floors as per existing complete all as specified and directed.
S&F in replacement sheet metal enclosures single door SPN MCB DB 2 way, 240 V AC, 50 Hz AC complete all as specified and directed.
S&F in replacement sheet metal enclosure double door SPN MCB DB 4 way, 240 V, AC, 50 Hz, AC having copper bus bar of rating 200Amps, fixing of serviceable MCBs retrieved under Srl item No 1 complete all as specified and directed.
All as per Srl item No 3 but 8way DB
All as per Srl item No 3 but 12way DB
S&F sheet metal enclosures double door VTPN MCB DB 4 way 415 V AC, 50 Hz with 250Amps rated copper bus bar complete with IP 43, IK-09 protection suitable for flush mounting into the wall including MCCB 63Amps, 4Pole, 16kA with fixed magnetic and thermal setting of same make as of DB, making connection with cable by menas of suitable size of Al thimbles including making good the disturbed surface to match with the existing surface complete all as specified and directed.
S&F MCB SP 240V, 50Hz, 10 KA, of rating 6 to 32 Amp complete all as specified and directed.
All as per item 7 but MCB SPN 240V, 50Hz, 10 KA, 32Amps
S&F in replacement MCB SP 240V, 50Hz, 10 KA, 40-63Amp complete all as specified and directed.
All as per item 9 but MCB SPN 240V, 50Hz, 10 KA, 40-63Amps
Taking down carefully serviceable single phase energy meters from meter box after carefully disconnecting the electrical connections and refixing the same, making connection complete all as specified and directed.
Taking down or dismantling existing meter box and S&F sheet moulded compound (SMC) meter box fire retardant type of size not less than 600x600x200mm to enclose 04 Nos single phase electric meters with hinged type front operated door having transparent acrylic sheet and proper locking arrangement, flush mounting in wall, making electrical connections including cleaning of disturbed area and making good the disturbed surface to match with existing surface complete all as specified and directed. Make: Sintex, Ship, HPL
S&FS&F sheet metal enclosure with plug & socket, MCB 20A SP, making connection with sub main wire with suitable size of copper thimbles including cutting chases on existing wall, mounting flush the sheet metal enclosure and making good to disturb surface of wall/floor with cement mortar and finishes to match with existing surface complete all as specified and directed. Make: Legrand, L&T, HPL, Anchor
Taking down carefully unserviceable copper/aluminium sub main wiring of any size including old broken steel/PVC conduit complete all as specified and directed.
S&F in replacement sub Main Wiring three single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable 4 sqmm (phase, neutral and earth), earth wire(green color) connected to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete, making good to disturbed surface of wall/floor with cement mortar and finishes to match with existing surface complete all as specified and directed.
All as per Srl item No 15 but cable size 6Sqmm.
All as per Srl item No 15 but cable size 4Sqmm drawn through existing concealed conduit.
All as per Srl item No 15 but for size 6Sqmm drawn through existing concealed conduit
S&F 200 Amps 4 way busbar chamber of size not less than 300x200x100mm made out of CRCA sheet of thickness not less than 2.0mm including 4Nos Aluminium bus bar of suitable size duly mounted on epoxy based post insulators with glands for cable entry and exit, flush mounted in wall/surface including making good the disturbed surface complete all as specified and directed.
Supply and fixing wall mounted industrial socket and plug (2P+E) of rating 32Amps with IP 67 protection duly mounted on wall with suitable size of bolts, nuts etc complete all as specified and directed.
Taking out from trenches or wall/ pole or pipe cable LT 1100 volts grade heavy duty, armoured or unarmoured, any type, any size/ core, seggregating serviceable and unserviceable cable, removing unserviceable cable from site and keeping aside serviceable cable for reuse at same location or any other location as rquired at site complete all as specified and directed. Note: Exacavation and earth work shall be measured and paid separately under respective item of this schedule.
Laying only in trenches or fixed to wall/pole or passing through pipe serviceable cables retrieved under srl item 21 and making connection to MCCB, Bus Bar of LT Panel with suitable size of Aluminium Thimbles complete all as specified and directed.
Supply, laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty, XLPE insulated, armoured heavy duty electric cable with aluminium conductor of size 10Sqmm 2Core including commissioning and testing complete all as specified and directed.
All as per item No 23 but of size 16 Sq mm, 2 core.
All as per item No 23 but of size 16 Sq mm, 4 core.
All as per item No 23 but of size 25 Sq mm, 4 core.
All as per item No 23 but of size 35 Sq mm, 3.5 core.
All as per item No 23 but of size 50 Sq mm, 3.5 core.
All as per item No 23 but of size 70 Sq mm, 3.5 core.
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 16 sqmm 4 core with working voltage 1100 volts. Make: Denson/ M Seal/Raychem
All as per Srl item No 30 but for size 25 Sqmm to 50 sqmm 3½ core.
All as per Srl item No 30 but for size 70Sqmm to 95Sqmm 3½ core.
M&L for tubes, light grade, galvanised with all fittings, laid in trenches/through wall/ under road or floor of 40mm bore including 2Nos FI Clamp with suitable nuts and bolts complete all as specified and directed.
All as per Srl Item No 33 but size 80mm bore.
Excavation in trenches in any type soil not exceeding 1.5m wide and not exceeding 1.5m in depth for cable and getting out complete all as specified and directed.
Returning filling in with earth obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50mtr and depositing at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed.
M&L for well burned bricks, laid flat (old size) sub class B designation 75 for cable protection with width equal to the width of brick complete all as specifed and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate for filling of road or floor or foundation bed etc. including necessary form work complete all as specified and directed.
Dismantling carefully old LT panel any size by breaking the PCC and disconnecting all the connected cables, keeping aside for taking credit of unserviceable items complete all as specified and directed.
S&F MCCB 100Amps 3Pole 415Volts, 16kA with adjustible thermal and adjustible magnetic setting, fixed in exisiting DB, making connection with cable by means of suitable size of thimbles complete all as apecified and directed.
All as per item No 45 but of 63Amps.
Taking down carefully of old unserviceable earthing strips with porcelain insulators from roof top/wall by unscrewing screws complete all as directed.
S&F aluminium strip for lightening conductor of size 25x3.15 mm with saddles and fixing screws on roof/wall with porcelain insulators complete all as specified and as directed.
M&L for galvanised iron strip 32x 6mm buried in ground including connecting with nut, bolt and inter linking with earth point with protection pipe complete all as specified and as directed.
S&F termination rod single pointed made of aluminium rod 12 mm dia and 300 mm long fixing on roof with aluminium strip including taking down old unserviceable termination rod complete all as specified and as directed.
M&L for test point terminal block made of gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia long hex screws including taking down old unserviceable test point, any type complete all as specified and as directed.
S&F 32mm bore light grade galvanised steel tubing, grouted on floor with PCC block at junction point of aluminium strip to mount the air termination rod complete all as specified and directed. Note: PCC work shall be measured and paid for separately under respective item of this schedule(BOQ).
M&L for earthing complete with galvanised steel earth plate electrode, 600x600x6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.50m below ground level connected to galvanized iron strip of 32x6mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI light grade pipe 40mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as specified and directed. Notes: 1. Earth strip & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
All as per Srl item No 53 here in before but with 4.0mm dia galvanised earth lead wire with protection pipe of size 20mm bore.
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 115330.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
Vijay Kumar Contractor and Engineers
ANU REFRIGERATION WORKS
KULBHUSHAN AGGARWAL
DASHMESH BUILDERS
M/S HIMANSHU BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .