Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹68.5 L
EMD Value
₹68,500
Closing Date
4 Mar 2023, 12:00 pmClosed
SE,EDC-IV,LESA-CISS GOMTI,MVVNL
4/82-83, INDERLOK HYDEL COLONY, KRISHNANAGAR, LUCKNOW
Construction of Line and Sub station and other related work at New Nagar Nikaye Area against Deposit Scheme under jurisdiction of EDD, CESS-II, Cis Gomti Lesa, Lucknow
2023_MVVNL_775653_2
91/EDC-IV/LESA/2022-23
Open Tender
Miscellaneous Works
Fixed-rate
90 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/C-1444100402,IFSC Code-CBIN0280139
₹68,500
Yes
23 Mar 2023
18 Feb 2023
4 Mar 2023
18 Feb 2023
4 Mar 2023
18 Feb 2023
Amount
ST Pole 11 Mtr. Long
PCC Pole 8.5 Mtr. Long
XLPE Cable 3x120 sq.mm
ABC 3x50/3x95/3x120
ID and OD Jointing Kit
11 KV Pin Insulator
GI Pin
11 KV VCB
ACSR weseal conductor
TF 400 Kva
TF 250 Kva
TF 100 KVA
TF 63 Kva
TF 25 KVA
PVC Cable LT 1x400/1x240/1x630 mm2
GI Wire 10 SWG
Line Material
Dragging of ST/PCC Pole digging of pit erection of sub-station type double pole structure on ST/PCC Pole with fixing of necessary item such as Top Channel, along with grouting (As per RESPO Norms) Dropper Channel, 11 pin insulator with Pin & 11 KV Disc Insulator with fitting, DO Fuse set its ramming, as per RESPO Specification. Only Pole and insulator will be Provided by the Department.
Fabrication, erection of double pole for end terminations/sectional double pole, 11 KV line on ST/PCC Pole with fixing of necessary clamps & other accessories like 1 nos top channel 100x50 mm 2.24 m. 1 No. Guarding Angle. Its grouting in ratio 1:4:8 plinthing 300 mm above ground level, earthing of support & one side cable expose.
Dragging of ST/PCC Pole to pit site, diging of pit erection and grouting (As per RESPO Norms) of 11 KV line with fixing of necessary item, such as V-type X-arm, F-bracket, 11 KV Pin insulator, Gaurding angle (1.8 mm 65x65x6) with Nut & bolts its ramming as per RESSPO Specification. Only Pole and insulator will be Provided by the Department.
Dragging of ST/PCC Pole from Dump Store to pit site, diging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification. Only Pole will be Provided by the Department.
Grouting & Nuzzling of 11 KV stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (Sand, Brick blast & cement). All material except stay wire shall be supplied by the contractor.
Ordinary earthing by 11 KV MS earth Rod 2500mm long as per RESPO Schedule. All material except earthing wire shall be supplied by the contractor.
Laying Stringing & sagging of 3 Phase 3 wire 11 KV New Line on ACSR Wesal/Racoon conductor as per RESPO Specification and direction on E/I. All material exept ACSR wesal/Racoon conductor shall be supplied by the contractor.
Guarding of HT line by GI wire. GI wire shall be supplied by the department.
Proper laying & commissioning of (3x50/3x95/3x120 sq.mm) XLPE Aerial Bunched Conductor. Only ABC Provided by deptt.
Fixing of Single/Three Phase distribution boxes/Kiosk on the LT poles including all clamps and material required for mounting connections & sealing. Only distribution box Shall be supplied by deptt.
Laying of 3X120 sq.mm 11 KV XLPE cable by drill method as per RESPO Norms. Only 11 KV XLPE cable supplied by Department.
Cable Hosting of 11 KV 3x120 sq. mm XLPE Cable at the following including jumpering etc complete with help of GI Pipe as Per RESPO Norms. GI pipe and other required material shall be supplied by contractor.
High pressure testing of 11 KV 3x120 XLPE cable along with arrangement of High Pressure equipment.
Well type earthing of with 60 Fit Deep borring and providing GI Pipe 1.5" dia ("B" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor.
Construction of T/F plinth of size 2x2x1.2 mtr with the help first class brick & masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely per norms with RCC to 1:2:2 cement & stone grit with MS bar and MS channel for resting transformer.
Wiremess fencing of 11/0.4 KV S/S shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I.
Construction of masonry/metalic type distribution pillar of size 1x1.5x2.5 mtr. with supply & fixing of fabricated 4 nos. doors (2ft.x4ft.) made of BP sheet of 18 SWG with locking arrangement, 2 Nos. Straight MS angle 50x50x6mm (1800 mm olng) 2 nos. 500 Amp, 3 Nos. 300 Amp henely Type Tailess Funse Unit, 3 Nos coper bus bar of size 1000x50x6 mm and one No. Alum busbar 1000x50x6 mm including all civil material required for work. All material shall be supplied by contractor.
Fabrication, errection & commissioning of 400 KVA T/F on Plinth with all accessories. All material except 400 KVA T/F shall be supplied by the Contractor.
Fabrication, errection & commissioning of 250 KVA T/F on Plinth with all accessories. All material except 250 KVA T/F shall be supplied by the Contractor.
Fabrication, errection & commissioning of 100 KVA T/F on Double Pole with all accessories. All material except 100 KVA T/F shall be supplied by the Contractor.
Fabrication, errection & commissioning of 63 KVA T/F on Double Pole with all accessories. All material except 63 KVA T/F shall be supplied by the Contractor.
Fabrication, errection & commissioning of 25 KVA T/F on Double/Singel Pole with all accessories. All material except 25 KVA T/F shall be supplied by the Contractor.
Dismantling of 250 KVA T/F opening jumbers, LT cable and Other accessories of T/F including Safe loading, unloading Carriage from site to JE dump Store/Center Store.
Dismantling of 100/160 KVA T/F opening jumbers, LT cable and Other accessories of T/F including Safe loading, unloading Carriage from site to JE dump Store/Center Store.
Dismantling of 63 KVA T/F opening jumbers, LT cable and Other accessories of T/F including Safe loading, unloading Carriage from site to JE dump Store/Center Store.
Dismantling of 25/16 KVA T/F opening jumbers, LT cable and Other accessories of T/F including Safe loading, unloading Carriage from site to JE dump Store/Center Store.
Commissioning of 11 KV O/G FDR VCB at 33/11 KV S/S including connection with, Busbar its Empire tap, PVC tap after grouting 2 No. Channel 75x40 mm 0.90 M lag its commissioning after taking proper S/D.
Earthing of 11 VCB with GI flate 50x6 mm with existing earth matt its welding etc.
Making of Heat & shrinkables joints of 3x120 sq.mm. ID and OD types in 11 KV XLPE cable (Jointing kit will be provided by deptt.)
Supply and fixing of L piece as per RESPO Nroms
Supply and fixing of Allu Lug 400 sq.mm. as per RESPO Nroms
Supply and fixing of Allu Lug 240 sq.mm. as per RESPO Nroms
Fixing and laying of LT PVC Cable 1x400/1x240//3.5x400/1x630 sq.mm as per RESPO Norms
Lopping & Chopping of tree branches for clearance of HT/LT line. After clearance of line through out pieces of tree branches of site.
ERRECTION & INSTALLATION OF 10 MVA Power TRANSFORMERS and removing of 8 MVA Power Transformer Work
Safe carriage of 10 MVA Transformer from Central Store Daliganj To JE Store/Site including loading & unloading as per RESPO Norms. All T & P arranged by contractor
Erection and installation of 33/11kV 10 MVA transformer in a levelledposition on the plinth. The work include shifting of transformer to the site of installation within the substation premises, assembling fixing and fitting of all accessories and filling of transformer oil to the desired level and insuring that there is no leakage. All the jumpering & connection are included in the scope of work.
Earthing by way of boring and lowering of "B" class GI pipe 50mm dia from ground upto the water level (minimum 60 meter deep) as per standard practice
Fabrication and grouting of M.S Angle 75X75X6 mm in L shape & in proper size and alignment to provide support for the two separate earthing strips for power transformer neutral including supply and fixing of two nos. Flexible copper bonds for neutral earthing.
Fabrication and erection of cable support made of two pieces of M.S channel 100x50mm,3.0 Mtr.long joined to each other by means of 5 Nos. M.S Flat 50x6mm pieces of size 150mm long each by welding at equal intervals as per drawing and grouting in a block of size300x300x700mm complete with one coat of ready mixed primer and two coats of aluminium paint. This includes providing of four nose M.S clamp made of M.S flat holding the cable including nuts and bolts and fixing of XLPE Cable.
Dismantling of Cable stand of 33/11 S/S FCI & removing connection of Old 8 MVA Transformer and removing of earth flate by broking welding.
Dragging, loading and safe placing of 8 MVA T/F from plinth to out side of Yard at FCI S/S with help of Crain and T&P.
Draining out of oil from the radiators and storage in empty drum and dismantling of radiators, conservator tank etc. and safe placing at 33/11 KV Sub Station FCI
Safe carriage of 8 MVA Transformer and other accessories from 33/11 KV Sub Station FCI to Central Store Daliganj OR as per officers insutruction. All T & P arranged by contractor.
GST Extra as per Rules
SVV Electro Engineering Pvt Lt
Saraswati Electricals & Contractors
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .