Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹51.3 LAccepted-AOC 20421 STREET NO 9 AJIT ROAD BATHINDA | BATHINDA | BATHINDA | PUNJAB | L-1 | Accepted-AOC Ok | |
| 2 | Not Admitted-Finance NOT SPECIFIED | - | Not Admitted-Finance Not qualified for AOC | |
| 3 | Not Admitted-Finance 302 VISHAL NAGAR PH 2 BATHINDA | BATHINDA | BATHINDA | PUNJAB | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
7 Jun 2021, 5:00 pmClosed
Executive Engineer
Water Supply and Sanitation Division No.2, Bathinda
Improvement of water supply coverage in Village Ghanda Bana Block Phul, Distt. Bathinda Under Programme 1a ii and JJM
2021_WB_65205_1
01/10/05/2021
Open Tender
Civil Works
Item Wise
180 days
Works
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹98,000
3 Dec 2021
12 May 2021
8 Jun 2021
12 May 2021
7 Jun 2021
12 May 2021
Loading of unloading of earth for footpath.
Carriage of earth filling
Carriage of Surkhi, sand, bajri, ballast, stone, boulders, kankar, building rubbish Carriage of material excluding initial lead of 5 Km a) Jalalabad Sand (Av. Lead 100 Km) Up to 100 km
Ghaggar Sand & Bajri (Av. Lead 300 Km) Upto 300 Km
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation.
Earth filling under floors with surplus soil or soil containing gravel or kanker up to 40% excavated from foundation.
Centring and Shuttering for flat surface such as suspended floors,Roofs, landing, Chhajjas, Shelves etc.
Cement concrete 1:8:16 with 40mm gauge stone aggregate using concrete mixer volumetric type.
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
First Class burnt bricks work laid in cement sand mortar 1:5 in first storey upto 4 meters above plinth level.
115mm thick brick wall in 1:4 cement sand mortar
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
Top Khura 0.6mte. X 0.6mtr. For rain watewr pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16
Bootam Khurra on ground 1.2mtr. 0.6mtr. Consisting of brick on edge laid in cement motrar 1:3 over 75mm cement concrete 1:8:16 including 12.5 mm thick cement plaster 1:3.
Cement Concrete 1:2:4 gola 10cm x 10cm quadrant along junction of roof with parapet wall finished smooth where specially specified
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Conglomerate floor 40mm cement concrete topping 1:2:4.
Conglomerete floor 40 mm thick CC 1:2:4 on 100 mm thick CC 1:8:16 & 100 mm sand of stone filling
Providing & fixing glass strips 4mm thick in floors 40 mm wide
12.5 mm thick cement plaster 1:4 inside.
Pluster on under side of silling 10 mm thick cement plaster in 1:3 .
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.
Finishing wall with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Providing and Fixing 14 gauge MS Sheet garage doors with 40mmx40mmx6mm angle iron frame with digonal braces 3.15mm gusset plates including locking arrangement with handles etc. Complete in all respect.
Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade as per IS 1786-2008 for R.C.C. works, where not including in the complete rate of R.C.C. including bending, binding, and placing in position complete.
Supply & fixing of pressed steel frames (chowkats) consisting of 18 gauge thick steel sheet of the specified section (standard design latest) including iron lugs iron hinges, confirming to PWD specifications including bolts for fixing stops, lock etc. complete. a) Doors and windows frame of size 118 mm x 60 mm wide single rebate weighing 3.43 kg per meter
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering, including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. i) All classes of soil except rocky a) 40x0.60x1.10
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS:8329-2000, Class-K9 and laying the same in trenches to correct alignment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage. b) 100mm i/d pipe lines laid complete
Providing & fixing C.I / D.I. Flanged end, stem of SS ( AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete ( with the approval of Engineer in-Charge). A) Class PN-1 as per ISI a) 80mm i/d =
Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete. C) C.I Single air valve screwed (Size 40mm)
P/F ISI marked non return valves flanged end class pn-1.0 as per IS:5312/2004 in pipe line including jointing and cost of nutt bolt etc. complete. b) 100mm i/d
Bailing out water from the trenches for making new connections in existing pipe lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. a) Connection with pipe line upto 300mm i/d
Construction of masonary Sluice Valve Chamber complete in all respects as per standard drawing. Size 0.90 m. x 0.90 m.
Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation , stringing and jointing of pipe upto 160mm complete
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. (d) 200 mm nominal diameter (weight 41.6 kg per meter) 8.0mm thickness
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FRLS cable (ISI marked), 1100volts grade to be laid in heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for having electronic fan regulators (socket size), bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20 Amp. Sockets and 6 Amp./16/20Amp. Swithces (flush piano type accessories) etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (For Fan Box and Electronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:- Wiring fan point (With fan box)
Wiring light point
Wiring 6Amp. wall socket point
Wiring 16/20Amp. power plug control point
GALVANIZED IRON PIPES AND G.I EARTHIG: (xiii) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I.earth pipe (Cutting threads and 36 Nos.holes, 1cm dia. to make a mesh aroundthe GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length a) Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) a) Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm
Providing, Stringing out P . V. C Pipes ISI Marked as per ISI- 4985 (Premium Make or Equivalent) casting along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including specials complete as per specifications and excavation of pipe line, minimum cover on pipe One meter(6kg/cm2 pressure) 63mm o/d
Providing & fixing of ceiling fan of reputed quality such as crompton/Usha/Plar or equivalent of 56 inch size with reqgulator.
Providing & fixing of electeric tube rod set of reputed quality such as philips/salvania laxman or equivalent Full size.
Providing and fixing LED with holder of reputed quality such as philips/Salvania Laxman or equivalent Full Size.
Panel Board consisting of electrical appliances such as automatic Star Delta Push Button Starter, Main Switch, Volt Meter, Ampere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps,Kit-Kat etc complete in all respects.
Providing , installing , testing & commissioning one No. Electronically actuated , Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6.0 Litres of Bleaching powder solution/ Sodium Hypo Solution per Hour under maximum delivery pressure up to 7 Kg /sqcm and suction lift not less than 1.5m , as per DWSS standard specifications.
Construction of One No. RCC circular type, O.H.S.R of 75000 ltrs. Capacity having height 19 mtr. upto FSL 16.00 mtr. upto sill level complete. with external RCC stair case with landing slabs at each staging RCC roof, ventilator single manhole cover, lightening conducter etc.complete as described in schedule No.3. Providing and fixing C.I D/F expansion joints or latest bell mouth and D/F puddle collars as per DWSS design on the basis of enclosed drawing. Duck foot bends, Conforming to ISI-13382 and D.I.K9 D/F sluice valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet,outlet, scour pipe and over flow D.I. K-9 double flanged pressure pipes cost in sand moulds horizontally as per IS 8329-2000 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr. as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium ladder inside the OHSR complete in all respect as per specifications.(The specifications & drawing are based on safe bearing capacity of soil is 8.75 tone per Sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per Sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including overflow haudi, supplying fixing and testing automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible/monoblock to be fixed on existing panel for OHSRs, including plinth ptotection etc. complete in all respects.
Providing & Installing 100mm column pipe 45 mtr.
Copper Wire 6.00mm2
Heavy duty Flow meter ISI marked 100mm i/d double flanged
Provision for electricity pole and wire from old pump chamber to new pump chambe
Dismantling brick or flagged stone flooring without concrete base.
Dismentling of interlock paving & Reconditioning with laying of Interlocking Paver Block
Providing proposed water connection to house hold up to wall with providing laying jointing, testing GI pipe lines 15mm i/d=2.5 mtr. B-class as per CSR 28.36(A), (Above GI) providing and fixing MDPE pipe 15mm i/d with specials 2.00 Mtr (Below GI) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading and testing in trenches in the ground and ISI marked 10mm i/d ferrule as per IS : 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b)
Provision for connection of old pipe to new pipe line
Repair of existing water connection to house hold
Provision of 1 No. Toilet for Water Works
Painting of old picktes, main gate & Barbad wire
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .