Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.9 L+₹48,683.77 (1.27%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹39.9 L+₹1.5 L (3.89%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹43.9 L+₹5.5 L (14.3%)Rejected-Finance | L4 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | SHRI SIDHI VINAYAK ENTERPRISES L3 | SHREE SHIV SHANKER ENTERPRISE L2 | vishalconstruction L1 | BIHARI AND BROTHERS ASSOCIATES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings. | 490 | Sqm | 30 ₹14,700 | 25 ₹12,250 Lowest | 35 ₹17,150 | 29 ₹14,210 |
| 2.00 | Dismantling of timber scantling in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section unframed work | 200 | Rm | 12 ₹2,400 | 10 ₹2,000 Lowest | 35 ₹7,000 | 15 ₹3,000 |
| 3.00 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. | 440 | Sqm | 890 ₹3,91,600 | 850 ₹3,74,000 Lowest | 950 ₹4,18,000 | 888.5 ₹3,90,940 |
| 4.00 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified | 50 | Sqm | 875 ₹43,750 | 850 ₹42,500 Lowest | 900 ₹45,000 | 865.51 ₹43,275.5 |
| 5.00 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleat or other connecting plates ( Fe-410-W(Gde-E-250) quality-B | 375 | Kg | 145 ₹54,375 | 135 ₹50,625 Lowest | 150 ₹56,250 | 142.5 ₹53,437.5 |
| 6.00 | M & L for Preparation of New steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. | 70 | Sqm | 52 ₹3,640 | 50 ₹3,500 Lowest | 100 ₹7,000 | 54 ₹3,780 |
| 7.00 | Disconnecting existing water tanks (exc 250Ltrs not exc 500 Ltrs), setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) | 25 | Each | 255 ₹6,375 | 250 ₹6,250 Lowest | 300 ₹7,500 | 260 ₹6,500 |
| 8.00 | Disconnecting existing tanks (exc 500 ltrs not exc 1000 Ltrs) setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) | 15 | Each | 510 ₹7,650 | 500 ₹7,500 Lowest | 500 ₹7,500 Lowest | 516 ₹7,740 |
| 9.00 | Cleaning and removing all scale and dirt, etc, (exc 500 ltrs not exc 1000 Ltrs)from tanks (250 and from mouths of circulating pipes, etc.(date of cleaning shall be written with white paint on each tank after cleaning) | 150 | Each | 700 ₹1,05,000 | 500 ₹75,000 | 300 ₹45,000 Lowest | 715 ₹1,07,250 |
| 10.00 | Cleaning and removing all scale and dirt, etc, (exc 250Ltrs not exc 500 Ltrs)from tanks and from mouths of circulating pipes, etc.(date of cleaning shall be written with white paint on each tank after cleaning) | 50 | Each | 510 ₹25,500 | 500 ₹25,000 | 250 ₹12,500 Lowest | 505 ₹25,250 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Aug 2025, 6:00 pmClosed
GE Panaji
OPPOSITE KALA ACADEMY ST INEZ ROAD PANAJI GOA 403001
REPAIR AND MAINTENANCE TO ROOF INCLUDING RECTIFICATION OF LEAKAGE SEEPAGE AT MADGAON AND PONDA MIL CAMP IN AOR OF AGE BR MADGAON UNDER GE PANAJI
2025_MES_717419_2
8226/E8
Open Tender
Civil Works
Item Rate
180 days
GE Panaji
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER PANAJI
₹80,000
Yes
28 Nov 2025
4 Aug 2025
1 Sept 2025
4 Aug 2025
25 Aug 2025
11 Aug 2025
5 Aug 2025 - 9 Aug 2025
Amount
Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings.
Dismantling of timber scantling in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section unframed work
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleat or other connecting plates ( Fe-410-W(Gde-E-250) quality-B
M & L for Preparation of New steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified.
Disconnecting existing water tanks (exc 250Ltrs not exc 500 Ltrs), setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
Disconnecting existing tanks (exc 500 ltrs not exc 1000 Ltrs) setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
Cleaning and removing all scale and dirt, etc, (exc 500 ltrs not exc 1000 Ltrs)from tanks (250 and from mouths of circulating pipes, etc.(date of cleaning shall be written with white paint on each tank after cleaning)
Cleaning and removing all scale and dirt, etc, (exc 250Ltrs not exc 500 Ltrs)from tanks and from mouths of circulating pipes, etc.(date of cleaning shall be written with white paint on each tank after cleaning)
Dismantling water tanks and removing to store capacity exc 250 Ltr n.exc 500 Ltr
Dismantling water tanks and removing to store capacity exc 500 Ltr n.exc 1000 Ltr
S&F rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top ) hoisted & fixed in position all as specified in SSR PT I capacity of tank 1000 ltr including Gun-metal, globe or gate valves 25mm bore, with iron wheel head, screwed both ends & ball brass valves 20mm dia, high pressure, with polythene float and fly nut complete.
S&F rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top ) hoisted & fixed in position all as specified in SSR PT I capacity of tank 500 ltr including Gun-metal, globe or gate valves 25mm bore, with iron wheel head, screwed both ends & ball brass valves 20mm dia, high pressure, with polythene float and fly nut complete.
Taking down or up steel tubing and connections inculding cleaning for refixing or removal to store 15mm bore .
Taking down or up steel tubing and connections inculding cleaning for refixing or removal to store 20mm bore .
Taking down or up steel tubing and connections inculding cleaning for refixing or removal to store 25mm bore .
Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
-do-- all as above but for 25mm bore.
Supply and fixing in repair CPVC 20mm Brass Elbow (3/4 x 1/2)
Supply and fixing in repair CPVC 20mm Brass Tee
Supply and fixing in repair CPVC 20mm Male Brass Threaded Adaptor (MTA/ MBTA)
Supply and fixing in repair CPVC 20mm Female Brass Threaded Adaptor (FTA/ FBTA)
Supply and fixing in repair CPVC 25mm Tank Adaptor
Supply and fixing in repair CPVC 25mm Ball valve
Taking down cast iron water mains 80 mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead.
Taking down cast iron water mains 100 mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls.
Supply and fix 75 mm PVC(SWR) Bend
Supply and fix 110mm PVC (SWR) Bend
S & F 75 mm PVC (SWR) branch piece, single (single Y) equal or unequal provided with access door.
S & F 75 mm PVC (SWR) branch piece, double (double Y) equal or unequal provided with access door.
S & F 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal provided with access door.
S & F 110 mm PVC (SWR) branch piece, double (double Y) equal or unequal provided with access door.
Supply and fix PVC (SWR) vent cowl 75mm Dia.
Supply and fix PVC (SWR) vent cowl 110mm Dia.
S & F 75 mm PVC (SWR) bends any radius provided with access door.
S & F 110 mm PVC (SWR) bends any radius provided with access door.
Taking down cement plaster on brick or concrete surface including raking out joints, hacking for key, scrubbing out with water, etc. complete.
M & L rendering 15 mm thick on Brick or stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing in CM 1:4 without using extra cement with using water proofing compound. Note :-External plaster area n exc 2 sqm and Water proofing compound will be measered seperatly.
M & L rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing in CM 1:6 without using extra cement.
M & L plastering 5 mm thick on brick or concrete surface in CM (1:3) on ceiling to be finished even & smooth without using extra cement.
M&L for Preparation of new surface of wall and applying two coat of oil emulsion distemper over a coat of primer over 3mm thick wall care putty on internal walls surfaces complete all as specified and directed.
M&L for preperation of old decorated surface of wall washing rubbing down and stopping of distempered and painted surfaces and applying one coat of oil bound distemper on wall specified and directed
M & L Preparation of new plastered surface and applying 3 coats of white wash on ceiling
M&L for preparation of new plaster surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489-2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over a coat of primer complete all as specified and directed.
M&L for preparation of old plaster surfaces of walls by complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489-2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
Removal/Taking out wild growth, plants grown on external surface of building along pipe lines/roof till 4 storey and chemically treating the area/plastering the distrubed/damaged area with cement plaster 15mm thick in CM 1:4 without using extra cement with using 3% water proofing compound (plastering and water proofing compound will be paid separeatly) Complete all as specified and directed by Engr-in-Charge.
Dismantling of ceiling boards any thickness including cover fillets.
Supply and fix false ceiling work of aluminium anodised snap grid frame work, size of grid 605 X 605mm , 6mm thick Everest designer boards or equivelent (surface finished with one coat of Apex) fixed in Aluminium frame work with screws, including hangers 6mm dia, G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 X 3mm size 60mm long as in ceilings complete all as specified.
Demolition of cement concrete in below or above ground floor and paving exc 15 cm thk (unreinforced).
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises as specified and directed by Engr -in- Charge
Material and Labour for bitumen blown any grade applied hot two coats, to concrete surfaces at the rate of 1.5 kg per sqm per coat complete all as specified and directed.
Material and Labour for polythene film black 50 micron laid in floors complete all as specified and directed.
M&L for cement concrete type E2 1:5:10 (40 mm graded aggregate) in sunken floor all as specifed and directed (including WPC whose rate will be considered seperately)
M & L Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) 75mm thick as in sub base((including WPC whose rate will be considered seperately))
M&L cement concrete type B1 1:2:4 using 20mm graded stone aggregate25mm thick as in flooring etc.(including WPC whose rate will be considered seperately)
M&L non-skid ceramic coloured tiles 400x400mmx 7 to 12mm thick in floors etc set jointed in neat cement slurry and pointed in white cement or coloured cement to match etc including 15mm thick screed bed in CM 1:6.
S&F for in repairs white vitreous china squatting pan orissa pattern of size 580mm x 440 mm, with integral foot rest and P or S trap connection to trap and to flushing pipe front or back inlet including, trap and taking out old WC & connections incl 110mm PVC (SWR) WC connector with lip ring etc complete
S & F in repair PVC valveless, syphonic action type flush tank in repair, white, 10 litre capacity with inlet ball valve, float & handle incl brackets complete high level, flush pipes of PVC 32 mm dia for low lewel cistern, rubber cones, PVC connection 15 mm size with PTMT nut of length 600 mm, 15mm CP angle stop valve fancy type etc complete all as directed
S & F PVC (SWR) Gully trap 125/110 mm setting & jointing with solvent cement
S & F PVC (SWR) floor trap 75 mm dia, plain with grating including jointing with solvent cement
Demolition of any existing roof treatment including layer of bitumen felt, concrete padding,tiling and benching including hacking for key, scrubbing down with water complete to receive new roof treatment including rubbish off the factory premises complete all as specified and directed. (any thickness) and removing to distance 0.5 km to 1.5 km
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3
M&L for rendering 15 mm thick in CM 1:3 on fair faces of brick or concrete surface finished even and smooth without using extra cement and using WPC @ 3% by weight of cement. Note:- Water proofing compound will be measure and paid separated.
Supply only integral waterproofing compound
Material and Labour for water proofing treatment using 4mm thick APP modified membrane consisting five layer membrane with features as spcified, weighing not less than 4kg per Sqm laid over a coat of cold applied bituminous primer @ 0.4 litres per sqm on surface to provide a layer of APP membrane by torching applications including sealing the over lap while torching with 150mm on ;length side and 100mm wide side as per manufacturer instructions incl joints and change in direction be curved with cement mortar 1:3 mixed with SBR latex @ 200 ml/ bag of cement cured well before laying of membrane and provide a finishing coat with solar reflective bituminous aluminium paint @ 0.1 kg per Sqm complete all as specified and directed.
M&L Providing, cement concrete type B 0, 1:2:4(12.5 mm graded aggregate) in roof kerbs or mud stops, chajja ,parapet wall rounded or chamfered on edges span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Dismantling of existing rain gutter water pipe etc
Supply and fix uPVC box type rain water gutter pipes of width 160mm, depth 100mm, having thickness of minimum 3mm (4kg/sqcm guage) with added rib for extra strength, fixed in position with uPVC clamps and mild steel bands, straps, supports or stays, including uPVC gutter fittings like couplings,running outlet,corner / elbows (of desired degree), end drops, end caps, corner drop/elbow drop, leaf guard, etc all complete as specified and directed by Engr-in-charge. Note:- Rates for uPVC fittings to be used like centre drop, end drop, elbow drop etc to be deemed included with the quoted rates of the contractor, however mild steel works for clamps with neccessory items etc are included in this item.
Supply and fix uPVC square/rectangular/circular type rain water pipes of 90mm or above, having thickness of minimum 3mm (4kg/sqcm guage) fixed in position with uPVC clamps and mild steel bands, straps, supports or stays, including all uPVC fittings necessary like couplings, elbows, end caps,etc all complete as specified and directed by Engr-in-charge. Note:- Rates for uPVC fittings to be used like centre drop, end drop, elbow drop etc to be deemed included with the quoted rates of the contractor and mild steel works for clamps with neccessory items etc are included in this item.
Exposing existing RCC members such as columns, beams, slabs, lintels etc. up to the main reinforcement carefully by means of chisel & hammer, hard wire brushes or any other mehcanical means, so as to remove all loose concrete and cleaning the surface to remove all rust particles etc. and make the surface ready for further chemical treatment in bone dry condition.
M & L for 50 mm thick guniting in patches on to the required area on RCC/ PCC columns, beams, stairs, lintels, retaining walls, sunshades, roofing slab etc. of all sizes and shapes at all heights from existing ground floor and all locations with cement and mortar 1:3 (1 cement : 3 sand) under 2 to 2.8 Kg/Cm2 pressure after removing the damaged loose spalt concrete portions by chipping, removal of dust and applying one coat of rust converter/kp- 100 equivalent grade over reinforcement wherever necessary providing and tying in position 75x75x10 g MS welded mesh or smaller size over treated surface ready to receive grouts, curing for 10 days etc, complete operation all as directed including labour charges hire for all tools and plant machineries cost of consumables, scaffolding all types of protective equipments, plant floors, pipelines, vessels, materials etc. so as to do guniting in plant, removing the debris etc. rebound materials etc. to low lying areas in the factory compound and leveling as directed, complete all as directed by GE. Note: (i) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with brushes, washed with water and alloy to dry. To this surface apply chemistic polycrete admixture at the rate not less than 2% by weight of cement or as per manufacturer's insturctions. (ii) When polymix coating is in tackey condition guniting is done with polycrete admixture at the rate not less than 2% by weight of cement or as per manufacturer's instruction. Polycrete admixture shall be procured form Chemical Adhesive Pvt Ltd Co or their authorized dealer. (iii) Cost of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
Demolition of Reinforced cement concrete in column,chajja ,Rcc slab ,shelfes ,Rcc tank and etc
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) →
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for RCC Type (B1 1:2:4) 12.5mm gradedaggregate as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves,chajja and the other misc like all as per directed by Engr in Charge
M&L for RCC 1:2:4 type B1 (12.5mm graded aggregate) as in benching for chajja and other similer work and etc complete.
SHREE SHIV SHANKER ENTERPRISE (BID ID -3397803)
SHRI SIDHI VINAYAK ENTERPRISES (BID ID -3393791)
BIHARI AND BROTHERS ASSOCIATES (BID ID -3390296)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .