| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 3 294 SURESH CHANDRA SHUKLA NYAYA MARG PRIMARY SCHOOL BHARWARA 1 GOMTI NAGAR GOMTI NAGA LUCKNOW UTTAR PRADESH 226028 | LUCKNOW | UTTAR PRADESH | 226028 | Admitted-Finance |
| 2 | Admitted-Finance PINDRA PURA RAGHUNATHPUR VARANASI PURA RAGHUNATHPUR VARANASI LAL BAHADUR SHASTRI INTERNATIONAL AIRPORT VARANASI UTTAR PRADESH 221006 | VARANASI | UTTAR PRADESH | 221006 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹40.4 L
EMD Value
₹80,884
Closing Date
6 Dec 2024, 2:00 pmClosed
AGM EM
FCI RO Lucknow
Improvement of Security lighting with LED street light etc. at FSD Naini under DO Prayagraj.
2024_FCI_836767_3
EM/04/2024-25
Open Tender
Electrical Works
Item Rate
90 days
FSD Naini
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹80,884
30 Mar 2025
27 Nov 2024
9 Dec 2024
27 Nov 2024
6 Dec 2024
27 Nov 2024
Amount
Supply and Fixing of 7 mtrs single section Hot dip Galvanized(as per BS EN ISO 1461) octagonal Street light pole (specification not less than, top dia 70 mm, Bottom dia 130 mm & base plate 220mm*220mm, 12 mm thickness IS 2062, 4 Nos. of "J'" type 20mm dia.,600mm length, with projected length of 125mm, Foundation bolts) having 3 mm thickness, of grade S355 and a vandal resistance, water proof door opening of approximate 400-500mm length at an elevation of 450-500mm from base plate for cable connection and including of GI bracket (of minimum 1000 mm length each from pole) supporting to min 02 street lights, on RCC foundation grade- M20 with base of depth 1200 mm including 200-250 from Free Ground level and width of 400-450 mm including the cost of foundation bolts, excavation and back filling complete in all respects as required as per relevant BIS/IS standards as per the direction and approval of engineer-in-charge .
Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 40 mm dia (OD-40 mm & ID-35 mm nominal)
Supply of PVC insulated PVC sheathed cable of 1.1KV grade armoured Underground aluminum conductor cable as reqd confirming to IS –7098 part I with up to date amendments) of the following size as per the direction and approval of engineer-in-charge .
4X10 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. Above 35 sqmm & upto 95sqmm
Supply , Installation, of suitable size 3mm phenolic laminated sheet having 1 nos. terminal having 5 point for 3 phase, 1 netrual & 1 earth on and 1 no. SP MCB 5/6A , interconnection etc are required.
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (conforming to IS 12943 (1990) or equivalent with upto date amendments)
4 X 10 sq. mm (25mm)
Supply of 120W pressure Die cast aluminium housing streetlight with system lumen of minimum 16800lm & system efficacy of 140Im/W, IP66, IK10, Single piece die cast including spigot, dia 48-76mm,with integrated optical cover. Streetlight should have standalone lighting control system with AUTO on/off based on Dusk/Dawn timings, preset time setting with monthly variation(Jan to Dec.), inbuilt Real time clock for switching, includes dimming profile for energy savings, drift not exceeding max 2mins per year, clock retention upto minimum two years, auto switching off secondary power for module, dimmable driver based on PWM control, dim to off with High/Low Voltage cut off with 440V protection for 8 hrs for complete luminaire including driver and Astro module, EMI/EMC complaint as per EN55015,IEC61547.surge protection as per IEC 61000-4-5,driver meeting IEC61347,complete luminaire meeting IEC60598-2-3-2002, Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval and as per the direction and approval of engineer-in-charge .
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (conforming to relevant BIS/IS codes)
Supplying and drawing of Flexible PVC round insulated copper cable of following size a) 3 X 1.5 SQMM
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3X2.5sq mm
3X1.5sq mm
5X1.5sq mm
Supplying and fixing of 25mm dia size of medium class steel conduit along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing metal box of sizes 200 mm X 150 mm X 75 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm X 150 mm X 75 mm
Supplying and fixing 5/6 Amp Piano type Switch on the existing switch box/ cover including connections etc. as required.
Supplying of 18 to 22 watt LED polycarbonate batten with 100 lumens/watt. (Confoming to relevent BIS/IS standard or equivalent) as per the direction and approval of engineer-in-charge .
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required conforming to relevant BIS/IS codes.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supply , Installation, Testing & Commissioning of 120 Watt ,110 Lumen/Watt LED flood light luminaire with mandatory driver set having die cast aluminium body comprises of elegantly designed highly efficient lenses ,heat Resistant and toughened glass cover with IP-66 Protection fitting as per the direction and approval of engineer-in-charge .
V R ASSOCIATES (BID ID -3132709)
R S ELECTRICAL (BID ID -3131558)
Dubey Trading Company (BID ID -3131969)
Saurabh Enterprises (BID ID -3132489)
AVADH KAARYA SOLUTIONS LLP (BID ID -3132721)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .