Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹33.8 LAccepted-AOC | ₹33.8 L Quoted ₹35.9 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹43.2 LRejected-AOC 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹43.2 L | L-2 | Rejected-AOC L-2 |
| 3 | L-3₹46.8 LRejected-AOC | ₹46.8 L | L-3 | Rejected-AOC L-3 |
| Sl No | Description | Qty | Unit | GUPTA ENGINEERING WORKS L2 | Allied Agencies L3 | Bodyline Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Maintenance and overhauling of DG set of capacity 400/500 KVA on every month including checking, cleaning, adjusting/tightening, oiling, greasing ,Engine oil changing,changing of all type of filters ,coolent topup and reseting of existing part decarbonising of battery terminals of DG set at different location of installation and keep ready the DG sets for proper functioning incl checking ,adjusting of valve 'V' belts pulleys, fan hub, idler, water pump, fiters engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbons brushes vibration dampers, springs, AVRs exhaust pipes, etc of following capacity of DG sets :-
Note : i) Minor spare part shall be included in the rate quoated like gasket,oilseal,nut,bolt washer etc,ii) other Spare part will be measured and paid separetely under respective item from 3.00 to 8.00'. | 9 | Each Job | 3,500 ₹31,500 | 4,000 ₹36,000 | 2,000 ₹18,000 |
| 2.00 | Disconnecting connection of radiator and taking down for servicing and cleaning and refixing complete as specified and directed | 3 | Each Job | 5,000 ₹15,000 | 4,500 ₹13,500 | 500 ₹1,500 |
| 3.00 | Supply only Air Filter suitable for 400/500 KVA DG Set. | 4 | Each | 3,000 ₹12,000 | 2,500 ₹10,000 | 2,000 ₹8,000 |
| 4.00 | Supply only Oil Filter suitable for 400/500 KVA DG Set. | 4 | Each | 2,000 ₹8,000 | 2,790 ₹11,160 | 2,000 ₹8,000 |
| 5.00 | Supply only deisel filter suitable for 400/500 KVA DG Set | 3 | Each | 3,000 ₹9,000 | 3,000 ₹9,000 | 1,500 ₹4,500 |
| 6.00 | Supply only Water separator suitable for 400/500 KVA DG | 3 | Each | 2,500 ₹7,500 | 2,250 ₹6,750 | 200 ₹600 |
| 7.00 | Supply only Coolant complete all as specified and directed. | 120 | Ltr | 75 ₹9,000 | 65 ₹7,800 | 150 ₹18,000 |
| 8.00 | Supply only Engine oil as per OEM specifications complete all as specified and directed. | 435 | Ltr | 175 ₹76,125 | 220 ₹95,700 | 525 ₹2.3 L |
| 9.00 | S&F in repair of ON load change over switch including enclosure, 630 Amp, 4 pole with advance neutral as per existing type and model including making cable/alluminium bus bar connection to the change over switch, fixing on existing panel or wall with nut/bolts , mild steel fastener all as req incl taking out old change over complete all as specified and directed. | 1 | Each | 45,500 ₹45,500 | 45,000 ₹45,000 | 22,000 ₹22,000 |
| 10.00 | S&F in repair of ON load change over switch including enclosure, 1000 Amp, 4 pole with advance neutral as per existing type and model including making cable/alluminium bus bar connection to the change over switch, fixing on existing panel or wall with nut/bolts , mild steel fastener all as req incl taking out old change over complete all as specified and directed. | 1 | Each | 70,000 ₹70,000 | 65,000 ₹65,000 | 32,000 ₹32,000 |
Updated dates
Tender Value
₹49 L
Closing Date
3 Feb 2026, 6:00 pmClosed
GE I RND Delhi
MILITARY ENGINEER SERVICES GARRISON ENGINEER I RND LUCKNOW ROAD TIMARPUR DELHI 110054
REPAIR COMPREHENSIVE MAINTENANCE OF EM INSTALLATION DG INSTALLATIONS AT ADRDE AGRA UNDER GE I RnD DELHI
2026_MES_747262_1
GE/RND/T-74/AGR/2025-2026
Open Tender
Civil Works
240 days
Agra
Class-D, cat- b (i)
2 documents required · 2 mandatory
₹500
GE I RND Delhi
Exempted
27 Mar 2026
5 Jan 2026
5 Feb 2026
5 Jan 2026
3 Feb 2026
20 Jan 2026
Maintenance and overhauling of DG set of capacity 400/500 KVA on every month including checking, cleaning, adjusting/tightening, oiling, greasing ,Engine oil changing,changing of all type of filters ,coolent topup and reseting of existing part decarbonising of battery terminals of DG set at different location of installation and keep ready the DG sets for proper functioning incl checking ,adjusting of valve 'V' belts pulleys, fan hub, idler, water pump, fiters engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbons brushes vibration dampers, springs, AVRs exhaust pipes, etc of following capacity of DG sets :- Note : i) Minor spare part shall be included in the rate quoated like gasket,oilseal,nut,bolt washer etc,ii) other Spare part will be measured and paid separetely under respective item from 3.00 to 8.00'.
Disconnecting connection of radiator and taking down for servicing and cleaning and refixing complete as specified and directed
Supply only Air Filter suitable for 400/500 KVA DG Set.
Supply only Oil Filter suitable for 400/500 KVA DG Set.
Supply only deisel filter suitable for 400/500 KVA DG Set
Supply only Water separator suitable for 400/500 KVA DG
Supply only Coolant complete all as specified and directed.
Supply only Engine oil as per OEM specifications complete all as specified and directed.
S&F in repair of ON load change over switch including enclosure, 630 Amp, 4 pole with advance neutral as per existing type and model including making cable/alluminium bus bar connection to the change over switch, fixing on existing panel or wall with nut/bolts , mild steel fastener all as req incl taking out old change over complete all as specified and directed.
S&F in repair of ON load change over switch including enclosure, 1000 Amp, 4 pole with advance neutral as per existing type and model including making cable/alluminium bus bar connection to the change over switch, fixing on existing panel or wall with nut/bolts , mild steel fastener all as req incl taking out old change over complete all as specified and directed.
Material and labour for 40 to 63 mm grade stone aggregate of black trap/granite/basalts spread in layers not exceeding 25 cm thick& well rammed in electrical substation complete all as directed by Engr in Charge
M&L air break switch gang operated device HT 11 KV triple pole outdoor type with 12 insulator 200 Amps rating with drop out fuse assly with fuse carrier and the fuse element mounted on insulator and steel frame mechanically operated with operating mechanism consisting of operating rod of 25mm bore light grade GI pipe of suitable length operative from ground level and with locking arrangement with MS flat iron clamp 50 x 6 mm including MS channel of suitable size and length to fixing GOD including nuts, bolts and washers all as specified and as directed.
S&F in repairs lightning arrestor HT,11 KV, 10 KA expulsion type complete with all fittings,transmission class complete all as specified and as directed.
S&F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLSH PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm with standard accessories along with one run of FRLSH PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed including taking down old one. Note: Two run of single core FRLSH PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
S&F sub main wiring using approved colour coding (Phase-red,Yellow & blue Neutral-black, Earth-green) complete with four single core FRLSH PVC insulated and unshealthed stranded copper conductor cable 10 sqmm as current carrying conductor and two run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 32 mm with standard accessories,suitable flexible pipe all as specified and directed including taking down old one. Note: Four run of single core FRLSH PVC cable with two run of earth contunity conductor and one run of conduit shall be measured as one unit.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fixing LED light fitting 2 feet, 10W, 220 V AC decorative type with driver holder amp including connecting up with three core flexible copper conductor cable of suitable size complete.
S & F LED light fitting 10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Material & Labour for fixing Isolator 40 Amp Triple pole , 415 volts, 36KA, type including necessary connection all as specifed and directed.
S&F in reparis New generation energy saving and environmental friendly long life LED street/security light fitting 60 Watt,made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection incl removing old light fittings All as specified and directed by Engr-in-Charge.
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets , light fittings, etc taken on credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
Material & labour for point wiring complete with FRLSH, PVC insulated unsheathed cable, 1100 volts grade confirming to IS-694, ISI marked, 1.5 Sq mm (nominal area) single core with copper conductor for phase and neutral, multistranded drawn through and including non metalic rigid PVC conduit of 20 mm dia and conduit accessories concealed in walls, floors, roofs etc, complete terminal box flush in wall with cover plate of required for mounting switches, socket, fan regulator etc including provisioning of FRLSH, PVC insulated un-sheathed 1100 volts grade, ISI Marked, 1.5 sq mm solid / multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed for the following.
One light / fan / bell point controlled by one switch
One 3 pin 5 Amps socket out let on independent board.
One 3 pin 5 Amps socket outlet on same board with other switches.
M&L for point wring ,using approved colour coding (Phase-red, Neutral-black, Earth-green) complete for one 15 Amp socket outlet on independent board with FRLSH PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core conforming to IS 694 in existing conduit including FRLSH PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core in green colour as earth wire connected to earth dolly complete all as specified and directed .
S&F switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed.
S&F for socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI marked included taking down old one complete all as specified and directed.
S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked including taking down old one complete all as specified and directed.
S&F for socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked including taking down old one complete all as specified and directed.
Complete removal of the wild grass/ vegetation,bushes from surrounding area of OHTs, Tubewells/Booster and installations area and making the surface clear and plain and spraying roundup chemical on the same clean area as directed after removing and depositing the same outside the MOD land complete all as specified and directed. Note- All necessary T&P will be provided by the contractor and no extra amount shall be paid for that seperately.
M & L for laying, connecting & testing four core flexible copper conductor as per existing type/model, PVC insulated heavy duty unsheathed cable 1100 volts grade 1.0/1.5 Sqmm from control box(water level sensor at RCC OHT) to display meter in pump room through ducts/under ground / suitable protection pipes etc including taking out unserviceable flexible cable all as specified and as directed.
M&L for Cutting road / hard standing to a size not exceeding 30cm in width and not exceeding 90 cm in depth for removal/ laying of GI pipe upto 100mm bore including making good so as to match with the existing finishes using PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) of 100 mm thick complete all as directed by Engineer-in-Charge.
S & F in replacement uPVC pipe with 50 mm nominal dia ,heavy duty suitable for rating 10 kgf/cm2 fixed complete to walls, ceilings or laid in floors/trench etc.,incl earth work complete as required all as specified and directed.
M&L for repair in leakages of 100 mm bore sluice valves by replacing Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required after dismantling ,refixing in existing position including testing on completion complete all as specified and directed. Note: Quoted rates inclusive of the materials mentioned above like Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required to arrest the leakages .
Dismantelling existing 12.5 HP submersible pump by disconnecting/lifiting and S&F new submersible pump of 12.5HP,10 stage,415V with necessary connection and lowering complete all as specified and directed. Note:-Old unsv motor shall be deposited to MES store all as specified and as directed by Engineer-in-Charge
S&F MCCB 4P 630 Amps 50 KA with rotory handle microprocessor based suitable with to fit in panels with existing frame size without any alteration to panel and suitable to fit in existing schneider make CVS model or any other make MCCB including taking out the old MCCB complete all as specified and directed by Engr-in-Charge
S&F MCCB 4P 400Amps 50 KA with rotory handle microprocessor based suitable with to fit in panels with existing frame size without any alteration to panel and suitable to fit in existing schneider make CVS model or any other make MCCB including taking out the old MCCB complete all as specified and directed by Engr-in-Charge
S&F MCCB 4P 250 Amps 35 KA with rotory handle microprocessor based suitable with to fit in panels with existing frame size without any alteration to panel and suitable to fit in existing schneider make CVS model or any other make MCCB including taking out the old MCCB complete all as specified and directed by Engr-in-Charge
M & L for filtration/dehydration transformer oil of transformer capacity 50 KVA to 800 KVA indoor/outdoor type, pole mounted / plinth mounted in situ till achieve dielectric strength min 40 KV at 4mm gap incl all other accessories as required complete all as specified and as directed.Note :- Cotractor has to arrange his own power supply system for dehydration process quoted rate shall be including the same.
M&L in repairs of existing valve pit chamber of following sizes by demolishing the existing bricks work and foundation concrete and M&L for 230 mm thick brick walls of following size valve pit complte with mild steel sheet cover of 1.8 MM thick and angle iron of size 40x40x6MM duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and including locking arrangement and lifting handle and plastering in cement mortar 1:4 and 10 mm thick plaster to all internal and external exposed surfaces including two coats of white wash on wall complete all as directed by Engineer-in-Charge.
Valve pit size 1200x1200x900 mm
Valve pit size 900x900x900 mm
Taking down carefully unservicable sub main wiring (6 Sqmm to 10 Sqmm size) including removal of batten/ conduit/ gutties/ wooden board etc and removal of unservicable items out of site complete all as specified and directed. Note: 2 runs of cable and one run earth wire will be measured as one length
S&F ceiling rose, surface Bakelite, isolated body three terminals complete all as specified and directed.
S&F Electronic fan regulator steped type (flush type) 240 volt ,50Hz ,single phase on existing phenotic laminated sheet with neessary connections including taking down old complete all as specified and directed.
S&F in repairs LED Energy saving, environment friendly, long life, exclusive innovative die-cast aluminium flood light 180 Watt, with highly efficient LEDs as light source, suitable for highlighting architectural features complete all as specified and directed by Engr-in-Charge.
S&F in repairs cable jointing kit for 11 KV (earthed) grade cable, for straight through hot shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of 185 Sqmm.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm all as specified and as directed.
S&F MCB TPN 63 Amp,C curve, 415 Volts, 50 Hz suitable for existing type and connection with copper lugs including taking down old unserviceable complete all as specified and directed.
S&F MCB TPN 32 Amp,C curve, 415 Volts, 50 Hz suitable for existing type and connection with copper lugs including taking down old unserviceable complete all as specified and directed.
M&L for Isolate the water supply and empty the under ground water sump by using pumps of suitable capacity,after emptying the sump cutting/opening the existing rusted/damaged foot valve.S&F new Brass food valve of size 100mm bore,flanged/threaded type,IS:4038,PN 0.2 with strainer and joining with existing suction pipe line including all connection items like nuts,bolts,washers,flanges etc complete all as specified and directedd.
S&F in repairs of MCCB 125 Amps adjustable type 25 KA, 3 pole, 415 volt in existing LT panel complete connetions all as specified and directed.
S&F in repairs of MCCB 100 Amps adjustable type 16 KA, 3 pole, 415 volt in existing LT panel complete connetions all as specified and directed.
S&F in repairs of MCCB 63 Amps adjustable type 16 KA, 3 pole, 415 volt in pumphouse LT panel complete connetions all as specified and directed.
Removing old rusted pipe line of 100mm CI raising main pipe under the over head RCC tank of 23 Mtr height and M&L for fixing of 100 mm New CI flanged end ,centrifugally cast class A pipe with all fittings and connecting sluice valve ,supporting frame etc all as specified and as directed by Engineer-in-Charge . Note:- a. Neacessary scaffolding and manual/mechanical liftting arrangement to fixing the pipe shall be included in the quoted rate b. Removing exisiting sluice valve and refixing with new pipe also included in the quoted rate
Removing/Taking up CI/steel tubing of 100mm dia bore laid in trenches disconnecting all fittings including cleaning the pipe for removal rust and deposit to MES store all as specified and as directed by Engineer-in-Charge
All as per item Ser No 52.00 above here-in-before but 80mm dia bore.
Relaying of old CI/steel tubing of 100mm dia bore in new or old position in trenches including new GI/CI fittings after cleaning by suitable chemical, roding, cutting to required length, screwing ends etc. as per site requirement complete including connection with exsisting pipe line ,required size of Tee, incl earthwork complete all as specified and directed. Note: GI pipe retrieved from item No. 52.00 & 53.00 here-in-before shall be used after cleaning.(ii) The quoted rate shall also be including of clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and removing chequred tiles/interlocking tile during the excavation relaying the same after the completion.
All as per item Ser No 54.00 above here-in-before but 80mm dia bore.
Supply & fixing, testing & Commissioning of CI sluice valves of 80mm bore class PN 1.6 ISI mark flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with including nut and bolts washers and rubber gasket, taking down old unsv sluice valve complete all as specified and as directed.
Taking out or down defective sluice valve of 100 mm bore from main line in any position and opening carefully for servicing, over-hauling / greasing etc, and replacement of old unserviceable / worn out parts and reassembling the sluice valve after repair and refixing the same & testing after installation complete, all as specified and directed for following bores :- Note :- (i) The cost of Earth work, joints & jointing materials washers, gaskets and minor parts shall be deemed to be included in the quoted rates(iii) Replacement of the defective parts i.e. cast iron gate & stainless steel spindle of Sluice valve shall also be included in the quoted rate.
Supplying, fixing & laying of 25x6 mm size cooper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of nuts & bolts, screws, DMC insulators etc including riveting, soldering & making necessary connections as approved, specified and directed by the Engineer-in-Charge.
Supply and fix in repair of 100mm dia medium grade galvanised steel water tubes with screwed joints together with and including all GI fittings such as bends elbows tee, unions, sockets short piece connection, backnuts, caps plugs, union coupling, flanges, socket etc laid in trenches in new or old position and including earth work and removing old pipeline complete all as specified and as directed. Note:- (i) The rates quoted inclusive of earth work,cutting, jointing and leakage testing of the pipe.(ii) The quoted rate shall also be including of clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and removing chequred tiles/interlocking tile during the excavation relaying the same after the completion.
All as per item ser No 59.00 above but 80 mm bore.
All as per item ser No 59.00 above but 50 mm bore.
All as per item ser No 59.00 above but 40mm bore.
All as per item ser No 59.00 above but 25mm bore
All as per item ser No 59.00 above but 20mm bore
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel . supplying and laying charcoal stone aggregate) chamber and RCC cover of size 54x54x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in drawing Note - Cost of GI stripand GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items.
Maintenance and overhauling of DG set of capacity 20/40 KVA on every month including checking, cleaning, adjusting/tightening, oiling, greasing, Engine oil changing/Engine oil servicing,changing of all type of filters ,coolent topup and reseting of existing part decarbonising of battery terminals of DG set at different location of installation and keep ready the DG sets for proper functioning incl checking ,agdusting of valve 'V' belts pulleys, fan hub, idler, water pump, fiters engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbons brushes vibration dampers, springs, AVRs exhaust pipes, etc of following capacity of DG sets :- Note : Spares part will be measured and paid separetely under respective item of BOQ/ Sch 'A'.
Disconnecting connection of radiator and taking down for servicing and cleaning and refixing complete all as specified and directed.
Supply only Air Filter suitable for 20/40 KVA DG Set.
Supply only Oil Filter suitable for 20/40 KVA DG Set.
Supply only deisel filter suitable for 20/40 KVA DG Set
Supply only Water separator suitable for 20/40 KVA DG set
Supply only Coolant complete all as specified and directed.
Supply only Engine oil as per OEM specifications complete all as specified and directed.
Dismantelling existing 12.5 HP centrifugal pump by disconnecting all electrical connections and S&F new centrifugal pump of 12.5 HP,415V with necessary connection testing complete all as specified and directed. Note:-Old unserviceable pump shall be deposited to MES store all as specified and as directed by Engineer-in-Charge
M&L for cutting the existing GI pipe line 80mm dia and inserting Tee of size 80x80x80mm for making new branch conection of GI pipe of size 80mm dia including necessary Tee, fittings, excavation, returning and filling and depositing excavated material outside of the MOD land complete all as specified and as directad
M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 40 KV at 4mm gap complete all as specified and as directed. Note :- (a) New transformer oil to be bought in company sealed ISI marked container with original test certificate (b) Filtration /dehydration of transformer oil shall be carried out at the location where transformer is installed and necessary filter/dehydration plant having pressure gauge, hour meter, temperature gauge to be brought at site by contractor
Supply and fixing in replacement calcium hypo chlorite dosing system motor with agitator , Voltage input:230 volt, single phase, 50 Hz , 1/2 HP including suitable PVC shaft ,corrosion resistant materials including suitable PVC connection hose complete system all as specified and directed. Note :- Old dosing motor shall be deposited to MES store
Supply and fixing in replacement of calcium hypo chlorine dosing pump adjustable type 30 ltr/hr capacity & 10 kg/cm2 pressure duly fitted on service tank with accessories including Lead Tubing, foot valve, Y strainer,Injectare,Connecting Nuts, NRV,Injection Check Valve, Clay Weight, and Ferrules,frame complete system all as specified and directed. Note :- Old Pump shall be deposited to MES store.
Supply and fixing in replacement of 100 Ltr PE/FRP tank suitable for fixing calcium hypo chloite dosing Pump and motor including lid and level gauge complete all as specified and directed.
Supply & Fixing in replacement of weighted Suction Line Strainer 6/8 '' or suitable size for calcium hypochloride Dosing Pump complete all as specified and directed.
Supply & Fixing in replacement of Injection Check valve 6/8 '' or suitable size for calcium hypochloride Dosing Pump complete all as specified and directed.
Supply only calcium based granular calcium hypochlorite chlorination chemical having the percentage of chlorine content 65% to 70% complete all as specified and directed. Note : Payment of item shall be released after submission of purchase voucher & manufacturer's test certificate.
M & L for taking out old corroded unserviceable MS sheet cover, frame etc from top of the roof of the under ground sump or valve chamber with MS channel base square / circular type , of any size and shape including providing of new cover made out of 3.15 mm MS sheet cover with 50 cm x 50 cm x 6 mm angle iron base frame including painting with two coats black bituminous paint over a coat of red oxide primer complete with locking arrangements all as specified and directed.
Transporting of Submersible/ Centrifugal Pump Set any capacity from Pump House/ E&M store yard at ADRDE/Vigyan Vihar/Raksha Vihar to nearest workshop for repairing including carefully loading/ unloading and back to old location etc complete all as specified and directed
Taking out submersible pump set for repair/ developement of Bore wells including dismantling and taking out column pipes of any Bore & length alongwith submersible cable, wire rope etc; and re-lowering the pump set after carrying out necessary development or repairs / replacement of defective parts all as specified and directed. Note : a) The spares (supply only) required for repairing the pump sets and rewinding of motor will be measured and paid seperetely under respective item. b) Consumable stores like cotton waste/cleaning materials lubricants , gland packing metal filling , machining and transportation from site to work shop are deemed to be included in rate quoted.
M&L for complete rewinding of submersible motors of 7.5/10/12.5 HP, AC, 3 phase, 440 volt with superior quality PVC insulated copper submersible winding wire of identical gauge and specification of the existing unserviceable winding wires with all necessary insulating materials and other connected works including cleaning of stator and slots, complete servicing and applying one coat of water proof epoxy paint to the exteriors of motor after preparation of surface and testing complete all as specified on load of capacity :- Note : Spares part will be measured and paid separetely under respective items:-
Motor bush upper and lower
Rotor bearing sleeve upper and lower
Motor thrust bearing
Motor housing upper
Motor housing (lower)
External Fan for submersible pump
Fan Cover assembly complete
Shaft sleeve assembly complete
Gland assembly complete
Disconnecting the suction and delivery CI/GI pipe line upto 150mm dia of centrifugal pump set of capacity 7.5/10/12.5 HP and removing it from its position carefully and refixing the same in its original position after repairing/replacement of bearing,fan blade,terminals,mechanical seal ,gland packing, nut,bolts,gasket ,cleaning of foot valve etc.incl electrical connections complete all as specified and as directed. Note : (i) Consumable stores like cotton waste/cleaning materials lubricants ,bearing, bearing sleeve, gland packing metal filling etc are deemed to be included in rate quoted.
M&L for taking out old unserviceable burnt winding of centrifugal motor 7.5 to 12.5 HP capacity, 3 phase, 415 volts, 50 Hz, AC supply after disconnecting all electrical connections and rewinding by using super enamelled copper conductor of existing gauge and size by maintaining existing turn ratio, applying insulation varnish and drying up to specified period to achieve desired insulation value including reassembling of motor after rewinding and testing and connecting all electrical connection using suitable size of lugs complete all as specified and directed.
Supply, laying and testing of CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPES (SDR-11) Pipes of 50mm(Outer dia)ISI marked as per IS:15778 tough, rigid , pipe cutting fixing with CPVC solvent cement and testing laid in floors,wall,ceilings complete all as specified and directad. Note :(a) Quoted rate shall including of necessary special fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc), Unions, Flange and tank adaptor) (b) The rates include for cutting chases in wall, floors etc and their making good in case of concealed pipe work and earth work in case of pipes laid in trenches.
All as per item Ser No 89.00 above here-in-before but 40 mm dia bore.
All as per item Ser No 89.00 above here-in-before but 32 mm dia bore.
All as per item Ser No 89.00 above here-in-before but 25 mm dia bore.
All as per item Ser No 89.00 above here-in-before but 20 mm dia bore.
S&F in repair 50 mm bore Gun metal globe or gate valve with iron wheel head, ISI marked screwed both ends for iron pipes in position including removing old unserviceable valve complete all as specified and directed.
All as per item ser No 94.00 above but 40mm bore
All as per item ser No 94.00 above but 20mm bore
S&F in repair foot valve 100 mm bore, ISI Marked, Brass body, heavy duty having one end flanged or internal screwed suitable to fix in suction pipe and other side strainer with leather flape and counter weight including all fixing arrengements as new nuts, bolts, washers and gasket including testing complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surface of ceiling in cement mortar 1:3 finished even & smooth (without using extra cement) complete all as specified and directed
M&L for preperation of newly plastered concrete surface of ceiling & applying three coat of white wash on ceiling surface complete all as specified and directed.
M&L for Writing letters or figures (Block, Roman,Italic or Indian) n exc 30cm high complete all as specified and directed.
M&L for 10mm thick screed bed with cement mortar 1:4 in roof surface including WPC @2% by wt of cement including taking/hocking existing plastered Surface complete all a specified and directed. Note-Integral water proofing compound shall be measured and paid under this item.
Dismantling cast iron work of any description as specified and directed
S & F Framed work in repair such as grills for Staircase etc, gratings, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of over head water tanks and similar work con- forming to Fe.290.Gde-E-165 incl necessary scaffolding complete all as specified and directed.
M&L for two coat of synthetic enamel paint to old steel surface of any description, over 10cm in width or girth, not otherwise described including preparation of surfaces as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in any mortar etc
M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed bed in CM1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as specified and directed
M&L for kota stone slab 20-25 mm thick in riser of steps ,skirting,dado and pillar laid over 10mm thick cement screed in CM 1:3 and jointed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises complete all as specified and directed.
M&L for glazed coloured ceramic tiles of size 450x300x6-7mm thick in vertical surface of walls like skirting/ dado etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles over & including 10mm thick rendering in CM 1:3 on other then fair faces of brick work wall finished rough to fix tiles complete all as specified & directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames n. exc 1.5 sq.complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames exc 1.5 sq. m but n exc 4 sqm complete all as specified and directed.
S&F 35 mm thick flush shutters factory made solid core construction with block boards core and plywood face panels, commercial type on both sides (ISI marked) fixed to chowkhats as per drawing (SSR or TD) complete all as specified and directed.
S&F 35mm thk 2nd class Hard wood Kiln seasoned and chemically pressure treated glazed & skeleton shutters, open rebated at prepared to receive glass/gauze (without sash bars) edges of framing plain, chamfered, or rounded, fitted with and incl cut and mitred beads for securing glass, gauge etc, size of members of shutters as specified in SSR Pt-I, Sec-8, clause 8.24 (a) fixed to chowkhats complete all as specified and directed.
S & F steel windows/ventilators with side hung shutters glazed or gauged including projection type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welding complete all as specified and directed. Note: Wire cloth and glass shall be measured and paid separately under respective item
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening including MS hold fast and similar article conforming to Fe-290 Gde-E-165-0 or Fe-310-o complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 with using 20mm graded stone aggregated as in cill, step and for inserting hold fast of doors and windows all as specified and directed.
S&F aluminum handle cast type anodized 150mm size complete all as specified and directed.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
M & L for applying two coat of synthetic enamel paints over one coat of pink primer on wooden surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified and directed.
M&L two coats of synthetic enamel paint on New steel surfaces of any description,over 10cm in width or girth, not otherwise described over one coat of red oxide primer including preparation of surfaces complete all as specified and directed.
Supply and fixing for 3 mm thick ordinary Sheet glassof ordinary quality and glazing with with aluminium rubber brush strip/fillet or beads, nut bolts or with rivets/pins in square exc 0.5 sq. m in each pane completed all as specified.
Supply and fixing wire cloth 0.56mm nominal dia of wire and avg width of aperture 1.18mm complete all as specified and directed.
Supplying and laying of CPVC pipes 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all Brass fitting, cutting, chasing, pinning and taking down pipes complete all as specified
Supplying and laying of CPVC pipes 25mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all Brass fitting, cutting, chasing, pinning and taking down pipes complete all as specified
S&F in position rotational moulded polyethylene triple layered water storage tanks white in colour with 500 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position with and including ball valve 20 mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) and dismatling of exisitng tank complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves 25mm bore, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed.
S&F in repair PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed. Note excavation, RFR,removal shall deemed to be under this item.
S&F PVC(SWR) bends 110 mm bore dia complete all as specified and directed.
S&F in repair Chromium plated 20mm dia, D type,60cm long towel rail fixed with & including CP brass screws & wooden/plastic cleats (min. weight 190gms) complete all as specified and directed.
S&F steel tank cover with zinc coating, dia of cover 500 mm and height 150mm of cut spherical shape and gas welded of spikes 2mm dia and 50mm length at 50mm c/c both bay in zig zag motion with ms hinges, hasp and staple fixed to existing PVC water water storage tank of any capacity including dismantling of old pvc water tank cover complete all as specified and as directed.
Taking down of cement or cement lime plaster of any description on brick work or stone walls etc including racking out joints, hacking for key scrubbing down with water etc including removal of debris complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 mixed with WPC on fair faces of brick work finished the surface even and smooth without using extra cement complete as specified and directed. Note:- Rate of WPC included in quoted rate.
M&L for rendering 15 mm thick in cement mortar 1:6 on other than fair faces of brick wall or concrete surface including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for brick work with fly ash bricks, old size, class designation 75, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 including demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed.
M&L for Preparation of newly plastered wall surfaces and applying Two coat of Oil Bound Distemper over a coat of primer using roller complete all as specified and directed
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on newly prepared surface of brick (plastered or un-plastered) or concrete surface complete all as specified and directed. Note: Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces with airless spray machine (Mechanical means) as approved by Engr-in-Charge . Apply 2nd coat after 1st coat is dry approximately 6-8 hrs between two coats.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm on old prepared surfaces of brick (plastered or un-plastered) or concrete surface complete all as specified and directed. Note: a) Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces with airless spray machine (Mechanical means) as approved by Engr-in-Charge . Apply 2nd coat after 1st coat is dry approximately 6-8 hrs between two coats. b) Work to be carried out on any E/M Installations including RCC Over Head Tanks of height upto 25.0 mtr stagging located at Vigyan vihar/Raksha vihar/ADRDE complex & Colony, the necessary MS scaffolding for painting including all other safety precautions materials shall be deemed to include in the quoted rate.
Removal of plants/trees//Shrubs from roof tops/sides, external walls of bldg, chajjas, wall junctions of rains water/CI soil /waste pipe junctions including taking out the roots entered in wall/slab surfaces and making good the disturbed surface using (1:2:4) type B-O or cement mortar (1:2)including repairing the GI/CI/PVC pipe joints which were damged during cutting/taking out process to match with the existing and finishing the disturbed surface to match with existing including necessary scaffolding/staging upto a height of 15 .00 M from the ground level complete all as specified and directed.
Demolition of PCC in ground floors and pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed.
M&L for 75mm thick cement concrete type C2 1:3:6 (using 40 mm stone graded crushed stone aggregate) as in plinth protection surface finished even and fair including forming construction (dummy) joints 6 mm wide & 10 mm deep and filled with filler at an interval not exceeding 3 metre and at change of direction complete all as specified and directed.
M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar (1:4) and pointing in white cement (1:2) using marble dust with admisture of pigment to match with shade of granite complete all as specified and directed.
M&L for scraping out loose motar/concrete by chiseling/ wire brughing complete and applying rust removing solution (rebaklene soulution) to exposed corroded reinforcement and applying a coat of epoxy primer (Nitozink primer from M/S Fosroc or equivalent as approved by GE) as per manufacture instructions providing and fixing of wire mesh of weight 2.5 Kg per Sqm and apply 25mm average thickness in CM (1:4) mixed with liquid integral water proofing compound (complast 'X' recommended by the manufacture with gunitting machine at a pressure not less than 5Kg/Sqcm finally rendering 10mm thick plaster in CM (1:4) using liquid integral water proofing compound (complast 'X' 421 i.e. from M/S Fosroc and nitobound AR from M/S Fosroc or equivalent as approved by GE) in the proportion recommended by the manfacture complete all as specifed and directed.
Supplying, laying, jointing & testing, in replacement of 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed,3.5 Core, 185 Sqmm nominal cross section in service connections laid in loops /ducts, along wall /pole or under floor /road or laid in trenches in new or old position including taking out old unserviceable cable complete all as specified and as directed.
All as per ser item No. 144.00 here-in-before but 150 Sqmm 3.5 Core.
All as per ser item No. 144.00 here-in-before but 95 Sqmm 3.5 Core.
All as per ser item No. 144.00here-in-before but 50 Sqmm 3.5 Core.
All as per ser item No. 144.00here-in-before but 35 Sqmm 3.5 Core.
Supplying, laying, jointing & testing, in replacement of 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated copper conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed,3.5 Core, 16 Sqmm nominal cross section in service connections laid in loops /ducts, along wall /pole or under floor /road or laid in trenches including taking out old unserviceable cable complete all as specified and as directed.
All as per ser item No. 149.00 here-in-before but 10 Sqmm 4 Core.
All as per ser item No. 149.00 here-in-before but 6 Sqmm 4 Core.
All as per ser item No. 149.00 here-in-before but 4 Sqmm 4 Core.
Supplying, laying, jointing & testing, in replacement of 1100 volts grade, 4 Sqmm,2 core cable, PVC insulated multistrand alluminium conductor unarmed cable in service connections laid in loops /ducts, along wall /pole or under floor /road complete all as specified and as directed.
S&F ACP retro sign board of size 1.5x1.1 Mtr using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT/LT substation Details, and Single line Schematic diagram of substation & water suppy installation. Retro sign board shall be pasted on 3mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners, nuts, bolts, washer etc complete all as directed by Engineer-in-Charge at site.
Servicing of LT panels/ automatic starters including minor replacement of burnt internal wiring, thimbles/ lugs, replacement of burnt bolts, nuts and washers and major replacement of accessories like MCCBs, MCBs, Changeover switches, Power contactor etc complete all as specified and directed. NOTE : 1. Minor accessories shall be included in the quoated rate. 2. Major accessories shall be measured and paid separately under relevant item
Taking proper shutdown & Isolate the LT electric supply and taking out the ACB of capacity upto 1000 Amps of any make and type and servicing of all minor/major parts of the ACB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire component as directed , inserting the ACB, testing the complete LT electric supply and putting on supply on load including Calibration of relay of 1.1KV LT ACBs installed at various sub stn area complete all as specified and directed. Note:- All cleaning /testing equipment/ safety equipment material shall be provided by the contractor and rate for the same shall be demed to be included in quoted rates.
Taking shutdown from sub-station & Painting and Servicing of LT feeder panel boards complete with removal of the dust, tightening of electrical connections, replacement of burnt nut/bolts with washers, replacement of connections wires as per power load requirement, including insulation tapping complete all as specified and directed by Engineer-In-charge.
Supply and fiixing LED Aviation obstruction light Die-cast aluminum housing with Red polycarbonate dome having IP -65, 240 V for Overhead Water storage tank or reservoir over the height of 1.5 mtr above the top of Tank including with fixing arrangement complete all as specified and directed.
Supply & Fixing in replacement, retro reflective installation board made out of acrylic sheet, size 1.2 x 1.0 Mtr. Writing with computer graphic marking, size of letter not more than 50 mm in length with approved white letter writing on blue back and border of 10mm all around including necessary grouting the installation board with PCC 1:2:4 with 20mm graded stone aggregate upto the depth of not exc. 50mm from ground level and to the ground with angle iron of size 40x40x6mm complete with necessary frame work, welding, bending etc complete all as specified and directed.
S&F in repairs instrument Cooling fan , 3000 RPM, 230 Volts 50 Hz complete within the panel including cutting of a suitable sized hole on the panel body and wiring with 1.5 Sqmm copper conductor cable and MCB SPN 6 Amps all complete complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m in deep & not exceeding 1.5 m wide and getting out in soft / loose soil including leveling and ramming complete all as specified and as directed.Note:- (i) The quoted rate shall be including of clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and removing chequred tiles/interlocking tile during the excavation relaying the same after the completion.
Returning, refilling in trenches exvcavated soils, including spreading leveling & well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Supply and spread dry sand for cable cushioning in trenches all as specified in clause 19.75 of SSR Part-I complete all as specified and directed. Note :- Only Punned thickness shall be measured for payment.
M&L for brick, subclass 'B' well burnt, laid dry flat in trenches for protection of cable with a maximum gap of 10 mm between two consecutive brick over LT cable, complete all as specified and directed.
Removal of excavated surplus soil to a distance n.exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
BOQ_836802.xls
BOQ • 1.09 MB
TDR.pdf
Tender Documents • 1.62 MB
Download all tender documents and submit your bid