Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹45.4 L+₹8.4 L (22.8%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹46.8 L+₹9.8 L (26.6%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹49.9 L+₹13.0 L (35.0%)Rejected-AOC | L4 | Rejected-AOC Not being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Nov 2021, 6:00 pmClosed
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR / REPLACEMENT / MAINTENANCE OF GI PIPE LINE AND ALLIED WORKS UNDER AGE E/M NO II OF GE (U) SECUNDERABAD
2021_MES_485346_1
GE(U)/SEC/TOKEN/15 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER UTILITY SECUNDERABAD
₹90,000
Yes
1 Sept 2022
30 Oct 2021
2 Dec 2021
30 Oct 2021
25 Nov 2021
13 Nov 2021
Amount
M& L for repair/rectification of leakages to water supply distribution lines 15 mm bore to 25 mm bore GI/PPR tubing with provision of necessary excavation,cutting of hard standing , returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples as required at site complete all as specified and directed.
All as per item No 1 above but for GI tubing 40 mm bore to 50 mm bore
All as per item No 1 here-in-before but for GI tubing 80 mm bore to 100 mm bore.
Attending compaints of BLOCKAGE OF WATER PIPE LINES / NO WATER SUPPLY AT ANY kind of ACCOMODATION ( MARRIED / OTM/ single / multi story building ) , IDENTIFY THE FAULTS including rectification by taking down of existing GI/PPR tubing up to 80 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site TO RESTORE WATER SUPPLY complete all as specified and directed.
Note:- ( For item 1 to 4 ) (i) all materials as required like pipes, fittings etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation , returning filling , removing of soil , taking down pipe, refixing of pipe after cleaning , cuttinng of hard standing , and PCC will be measured and paid separately under relivent items. (iii) rates of any kind of any kind of thread cutting in old pipes , T&P required deemed to be included in the quoted rate.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth and getting out in hard/dense soil for removing/laying of pipe line complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Taking up/down steel tubing laid in trenches, on wall/in floor/in plinth protection of Bldg including segregation of serviceable pipes and keep in safe custody for reuse, complete with all fittings and connections of the following sizes:-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Refixing of old steel tubing after cleaning and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Notes for item No 9.01 to 9.06 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old steel tubing after cleaning and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:- NOTE : rate quoted by the contractor incluisive of all kind of fittings, bends, flenge , thread cutting, scaffolding, , roof / wall drilling as required for crossing / passing of pipes etc as required for proper fixing of pipe
20 mm dia
25 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- NOTE : rate quoted by the contractor incluisive of all kind of fittings, bends, flenge , thread cutting etc as required for proper fixing of pipe
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Notes for item No 11.01 to 11.06 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:- NOTE : rate quoted by the contractor incluisive of all kind of fittings, bends, flenge , thread cutting, scaffolding , roof / wall drilling as required for crossing / passing of pipes etc as required for proper fixing of pipe
20 mm dia
25 mm dia
Notes for item No 12.01 to 12.02 :- (a) Excavation and Earth work shall be measured and paid separately.
Cutting existing CI / di / gi pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, GI fittings ,Joints and Earth work shall be measured and paid sperately under relevant items of this schedule.
50 mm Dia
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
Note for Sl item No 14.01 to 14.04 , Make : Zoloto / RAMCO
S&F in repairs cast iron / DUCTILE IRON MECHANICAL COUPLING / MECHANICAL JOINT / D JOINT heavy duty INCLUDING ALL JOINTING MATERIAL , ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/CI/DI/GI /PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETE all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) Quoted rate inclusive of cutting of any kind of pipes and all ITEMS as required for fixing and proper functioning of Joints. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Construction of valve chamber of size 1200 x 1200 mm (Internal size) 900 mm deep with 200mm thick PCC block masonary walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys(Godrej/Shell), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as indicated for valve chamber top cover, 4 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with locking arrangement, mild steel handle, and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock,for passing of GI Pipe of diia up to 80mm and other required materials in co-ordination with the concerned authorites complete all as specified and as directed. Note : GI Pipe will be measured and paid separately under relivent items.
M&L Cement Concrete 1:3:6 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Use and Waste of Formwork (if required), complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) as in Side Wall of Cable Duct, etc., complete all as specified and as directed.
Cutting the existing road straight by manual, depth not less than 0.75 meter and width as required for pipes up to 100 mm dia and refill the same with excavated soil up to 80 % road portion and 20 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
Cutting the existing building plinth protection by manual, depth and width as required for replacement of GI /any kind of pipes pipes up to 50 mm dia and refill the same with excavated soil up to 80 % plinth portion and 20 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) and making good of all disturbed surface complete all as specified and directed.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 450 x 450 mm complete all as specified and directed including takingdown old one make ASHLOK / INDELEC/JMV /TERCEL/ jmv/ AS APPROVED BY GE.
Material and labour for Rubber mat of size 1mX2mX20mm ISI marked
Material and labour for Rubber mat of size 1mX2mX10mm ISI marked
Supply and installation CPRI approved pump starter electric control panel board, for out door use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS GODREJ 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 32 Amps -01 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-01 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -01 No
Supply and replace MCB SPN 20 Amps in starter panel board c Curve 10 KA complete all as directed
Supply and replace MCB TPN 32 Amps in starter panel board c Curve 10 KA complete all as directed
Supply and replace MCB TP 32 Amps in starter panel board c Curve 10 KA complete all as directed
M&L for heavy duty PVC Insulated multistranded (round or flat type) copper conductor cable of size 150 sqmm single core 1100 volt grade drawn through cable duct/ laid on floor etc including connection by using copper lugs , nut bolts etc complete all as specified and as directed.
M&L for heavy duty PVC Insulated multistranded (round or flat type) copper conductor cable of size 120 sqmm single core 1100 volt grade drawn through cable duct/ laid on floor etc including connection by using copper lugs , nut bolts etc complete all as specified and as directed.
Supply and installation CPRI approved pump starter electric control panel board, wall mounted ,dust & vermin proof made out of CRCA steel sheet of 2 mm thick , having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary fixing arrangements including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following and size of the panel should not be less than 70CmX80CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 25 Amps -02 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-02 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -02 No (d) Connector 4 way 32 amps - 2 Nos
supply and fix submerceable pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 6 HP motor relay range 9-14 Amps complete all including necessary connections complete all as directed. Make L&T model number ss97756/equivalent from siemens /abb/schneider
supply and fix submerceable pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 10 HP motor relay range 13-21 Amps complete all including necessary connections complete all as directed. Make L&T model number ss95983/equivalent from siemens /abb/schneider
supply and fix DOL starter AC 3 duty 415 volt suitable for 10 HP motor relay range 09-15 Amps with single phase protection complete all including necessary connections complete all as directed. Make L&T model number ss94351/equivalent from siemens /abb/schneider
supply and fix submerceable pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 7.5 HP motor relay range 9-14 Amps complete all including necessary connections complete all as directed. Make L&T model number SS96210/equivalent from siemens /abb/schneider
Supply and replace thermal over load relay in existing DOL starter of capacity 5hp/7.5 HP as per existing relay range complete all as directed.
Supply and replace thermal over load relay in existing DOL starter of capacity 10 HP as per existing relay range complete all as directed.
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
S&F CI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed.
All as per item No 40 above but for 200 mm bore to 300 mm bore.
Burning out lead joint in position for following sizes of CI/DI pipe, removing old lead complete all as specified and directed :-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm Dia
M&L for run lead joint for CI pipe/DI pipe including spun yarn etc for spigot and socket pipes and fittiings complete all as specified and directed for the following bore of pipes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm Dia
Taking up unserviceable/ defective CI/DI/MS water mains (including all fitting ) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position including segregation of serviceable pipes and keep in safe custody for reuse complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm Dia
Refixing of old CI/DI/MS Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
80 mm dia
100 mm dia
150 mm dia
200 mm dia
300 mm dia Notes for item No 45.01 to 45.05 :- (a) Excavation and Earth work shall be measured and paid separately.
S&F ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Lead Joints / D-Joints will not be measured and paid separately. (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm dia Notes for item No 46.01 to 46.05 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply only GI fittings of any kind ( medium grade suitable for medium grade GI pipe of of size up to 25 mm
Supply only Gi fittings of any kind/type of size above 40 but up to 50 mm
Supply only Gi fittings of any kind/type of size above 65 but up to 100 mm
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, rising type K504, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed including taking down old one .
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
300 mm Dia
Rectification of lekages in pumping /delivery lines(GI/CI/DI/PPR) of size 50 mm to 100 mm at main/civil roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft&hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement , De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail peaces,any type of gasket , welding work etc as required to arrest the leakages completely and making joints, filling the trenches , site clearences and PCC at the top portion as required complete all as specified and as directed. Note:- (i) CI specials, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relivent items. (iii) Rate of any kind of gasket and Lead joint , necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate.
Rectification of lekages in pumping /delivery lines(GI/CI/DI/PPR) of size 150 mm to 400 mm at main/civil roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft&hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement , De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail peaces,any type of gasket , welding work etc as required to arrest the leakages completely and making joints,filling the trenches , site clearences and PCC at the top portion as required complete all as specified and as directed. Note:- (i) CI specials, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation exceeding 2 CUM and PCC will be measured and paid separately under relivent items. (iii) Rate of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate.
M&L for attending break down of water supply pipe line and repair to CI/DI/PPR water mains of size 80 mm to 300 mm bore at a given notice including necessary excavation in mud, in any type of soil , PCC,RCC, hard rock etc by manual or using special T&P such as JCB etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/tail peaces etc and making joints complete all as specified and as directed. Note:- (i) CI specials, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relivent items. (iii) RateS of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate.
sree venkateswara enterprises
sandhya enterprises
Srinivasa Consructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .