Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹3.9 Cr 27 BALLYGUNGE TERRACE KOLKATA 700029 E MAIL MEDIAL 7 REDIFFMAIL COM SUBHRABHATTACHARYA41 GMAIL COM | ₹3.9 Cr |
Tender Value
Refer Docs
Closing Date
18 Sept 2021, 11:00 amClosed
Construction of balance works of Regional Centre for Lalit Kala Akademi at 85 AJC Bose Road, Kolkata 700 014 to be executed at Risk and Cost of previous agency.
NBCC/SBGWB/KOL/LKA/etender/2021/306
NBCC/SBGWB/KOL/LKA/etender/2021/306
Open Tender-Domestic
Civil Works General
Kolkata, West Bengal
₹11,800
Exempted
31 Jul 2026
3 Sept 2021
18 Sept 2021
18 Sept 2021
24 Sept 2021
Bill Of Quantities
Name of Work:- " Construction of balance works of Regional Centre for Lalit Kala Akademi at 85 A.J.C Bose Road,
Kolkata – 700 014 to be executed at Risk and Cost of previous agency."
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
PART-I: SCHEDULE WORKS
SH: 2.0 EARTH WORK
1 2.8 Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or drains (not
exceeding 1.5 m in width or 10 sqm on plan), including dressing
of sides and ramming of bottoms, lift upto 1.5 m, including
getting out the excavated soil and disposal of surplus excavated
soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil Cum 157.50 - -
2 2.25 Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and
watering , lead up to 50 m and lift up to 1.5 m.
3 2.26 Extra for every additional lift of 1.5 m or part thereof in
excavation / banking excavated or stacked materials. - -
2.26.1 All kinds of soil - -
additional Lift of exceeding 1.5m & upto 3.0m Cum 46.25 43.83 2,027.36
additional Lift of exceeding 3.0 & upto 4.50m Cum 92.50 - -
additional Lift of exceeding 4.50m & upto 6.00m Cum 138.75 - -
4 2.27 Supplying and filling in plinth with Jamuna sand under floors,
including watering, ramming, consolidating and dressing
complete. Cum 910.25 - -
5 2.28 Surface dressing of the ground including removing vegetation
and inequalities not exceeding 15 cm deep and disposal of
rubbish, lead upto 50 m and lift upto 1.5 m. - -
2.28.1 All kinds of Soil
6 2.2 Supplying and stacking of good earth at site including and
Horticulture carriage upto 5 km (earth in stacks will be reduced by 8% for
SH: 4.0, CONCRETE WORK - -
7 4.1 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work
upto plinth level. - -
4.1.8 1:4:8 (1 Cement :4 Coarse sand : 8 graded stone aggregate 40
mm nominal size) Cum 4,301.15 - -
8 4.10 Providing and laying damp-proof course 40mm thick with
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 12.5mm nominal size). Sqm 257.80 5.00 1,289.00
9 4.12 Extra for providing and mixing water proofing material in cement Per 50
concrete work in doses by weight of cement as per Kg of
manufacturer‟s specification. cement 48.15 5.00 240.75
10 4.13 Applying a coat of residual petroleum bitumen of grade of VG-10
of approved quality using 1.7kg per square metre on damp proof
course after cleaning the surface with brushes and finally with a
piece of cloth lightly soaked in kerosene oil.
11 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1
cement :3 coarse sand : 6 graded stone aggregate 20mm
nominal size) over 75mm bed by dry brick ballast 40mm nominal
size well rammed and consolidated and grouted with fine sand
including finishing the top smooth
SH: 5.0, REINFORCED CEMENT CONCRETE - -
12 5.9 Centring and shuttering including strutting, propping etc. and
removal of form for:
5.9.1 Foundations, footings, bases of columns etc. for mass concrete.
5.9.2 Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc. Sqm 360.80 0.00 0.54
5.9.3 Suspended floors,roofs, landings, balconies and access
platform. Sqm 401.65 - -
5.9.5 Lintels, beams, plinth beams, girders, bressumers and
cantilevers. Sqm 332.15 - -
5.9.6 Columns, pillars, piers, abutments, posts and struts Sqm 453.35 - -
5.9.7 Stairs, (excluding landings) except spiral staircases Sqm 395.65 - -
ANIRBAN ANIRBAN ROY
ROY 17:10:08 IST
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
5.9.15 Small lintels not exceding 1.5m clear span, moulding as in
cornices, window sills, string courses, bands, copings, bed
plates, anchor blocks and the like. Sqm 196.45 5.00 982.25
5.9.16 Edges of slabs and breaks in floors and walls, - -
5.9.19 Weather shade, Chajjas, corbels etc. including edges Sqm 492.55 - -
13 5.11 Extra for additional height in centering, shuttering where ever
required with adequate bracing, propping etc., including cost of
de-shuttering and decentering at all levels, over a height of 3.5
m, for every additional height of 1 metre or part thereof (Plan
area to be measured). - -
5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan
area to be measured) Sqm 159.05 354.68 56,411.26
14 5.22 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level. - -
5.22.6 Thermo Mechanically Treated bars Kg 68.10 - -
15 5.22A Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
above plinth level. - -
5.22A.6 Thermo Mechanically Treated bars. Kg 68.10 2,060.28 140,304.83
16 5.30 Add or deduct plaster drip course/ groove in plastered surface or
mouldig to R.C.C. projections. metre 30.75 - -
17 5.33 Providing and laying in position machine batched and machine
mixed design mix M-25 grade cement concrete for reinforced
cement concrete work, using cement content as per approved
design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and
reinforcement, including admixtures in recommended
proportions as per IS: 9103 to accelerate, retard setting of
concrete, improve workability without impairing strength and
durability as per direction of Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330
kg/cum. Excess/less cement used as per design mix is
payable/recoverable separately). - -
5.33.1 All works upto plinth level Cum 6,296.15 - -
5.33.2 All works above plinth level upto floor V level Cum 7,014.55 102.12 716,324.28
18.00 5.35 Add for using extra cement in the items of design mix over and
above the specified cement content therein. Qntl 742.75 - -
SH: 6.0, BRICK WORK - -
19 6.1 Brick work with common burnt clay F.P.S.(non modular) bricks
of class designation 75 in foundation and plinth in: - -
6.1.2 Cement mortar 1:6 (1 cement: 6 coarse sand)
20 6.4 Brick work with common burnt clay F.P.S. (non-modular) bricks
of class designation 75 in superstructure above plinth level up to
floor V level in all shapes and sizes in: - -
6.4.2 Cement mortar 1:6 (1 cement: 6 coarse sand) Cum 5,426.15 50.00 271,307.50
21 6.34 Brick work with non modular fly ash bricks conforming to
IS:12894, class designation 10 average compressive strength in
super structure above plinth level up to floor V level in :
6.34.2 Cement mortar 1:6 (1 cement : 6 Coarse sand) Cum 6,006.20 - -
22 6.12 Half brick masonry with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in foundations and plinth in :
6.12.2Cement mortar 1:4 (1 cement : 4 coarse sand) Sqm 584.75 25.00 14,618.75
23 6.13 Half brick masonry with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in superstructure above
plinth level up to floor V level - -
6.13.2 Cement mortar 1:4 (1 cement : 4 coarse sand) Sqm 665.80 50.00 33,290.00
24 6.45 Half brick masonry with non modular fly ash bricks of class
designation 10, conforming to IS : 12894, in super structure
above plinth and upto floor V level. - -
6.45.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) Sqm 751.10 - -
25 6.15 Extra for providing and placing in position 2 Nos. 6mm dia. M.S.
bars at every third course of half brick masonry (with F.P.S.
SH: 8.0, MARBLE WORK - -
26 8.2 Providing and fixing 18mm thick gang saw cut mirror polished
premoulded and prepolished) machine cut for kitchen platforms,
vanity counters, windows sills, facias and similar locations of
required size of approved shade, colour and texture laid over
20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand)
with joints treated with white cement, mixed with matching
pigment, epoxy touch ups, including rubbing, curing, moulding
and polishing to edge to give high gloss finish etc. complete at
all levels. - -
8.2.2 Granite of any colour and shade - -
8.2.2.1 Area of slab upto 0.50 sqm Sqm 3,866.00 4.58 17,706.28
8.2.2.2 Area of slab over 0.50 sqm Sqm 3,907.40 - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
27 8.4 Extra for fixing marble /granite stone, over and above
corresponding basic item, in facia and drops of width upto 150
mm with epoxy resin based adhesive, including cleaning etc.
complete. metre 247.40 5.00 1,237.00
28 8.5 Extra for providing opening of required size & shape for wash
basin/ kitchen sink in kitchen platform, vanity counter and similar
location in marble/ Granite/stone work, including necessary
holes for pillar taps etc. including moulding, rubbing and
polishing of cut edges etc. complete. Each 386.60 35.00 13,531.00
29 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of
cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry
@ 3.3 kg/sqm including pointing in white cement complete.
8.9.1 8mm thick - -
8.9.1.2 Granite of any colour and shade Sqm 1,921.85 10.00 19,218.50
30 8.10 Providing and fixing stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in
urinal partitions by cutting a chase of appropriate width with
chase cutter and embedding the stone in the chase with epoxy
grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand :
4 graded stone aggregate 6 mm nominal size) as per direction of
Engineer-in-charge and finished smooth.
8.10.2 Granite Stone of approved shade Sqm 3,263.50 1.50 4,895.25
31 11.41 Providing and laying vitrified floor tiles in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS : 15622, of
approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), including
grouting the joints with white cement and matching igments etc.,
complete. - -
11.41.2 Size of Tile 600x600 mm Sqm 1,405.95 - -
SH: 9, WOOD WORK - -
32 9.1 Providing wood work in frames of doors, windows, clerestory
windows and other frames, wrought framed and fixed in position
with hold fast lugs or with dash fasteners of required dia & length
( hold fast lugs or dash fastener shall be paid for separately).
9.1.1 Second Class Teak Wood Cum 91,496.95 - -
9.1.1 Work already executed by the previous agency Cum 73,197.56 - -
9.1.1 Balance Work (Repair, Replacement or any other works
required for final hand over to NBCC / Client at their satisfaction)
33 9.12 Extra for providing frosted glass panes 4 mm thick instead of
ordinary float glass panes 4 mm thick in doors, windows and
clerestory window shutters. (Area of opening for glass panes
excluding portion inside rebate shall be measured). Sqm 5.80 2.28 13.22
34 9.20 Providing and fixing ISI marked flush door shutters conforming
to IS : 2202 (Part I) decorative type, core of block board
construction with frame of 1st class hard wood and well matched
teak 3 ply veneering with vertical grains or cross bands and face
veneers on both faces of shutters. - -
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws Sqm 2,606.45 165.09 430,298.83
35 9.26 Extra for cutting rebate in flush door shutters (Total area of the
shutter to be measured). Sqm 104.55 137.07 14,330.67
36 9.33 Providing and fixing expandable fasteners of specified size with
necessary plastic sleeves and galvanised M.S. screws including
drilling holes in masonry work /CC/ R.C.C. and making good etc.
complete. - -
37 9.36 Providing and fixing specified wood frame work consisting of
battens 50x25 mm fixed with rawl plug and drilling necessary
holes for rawl plug etc. including priming coat complete.
9.36.1 Kiln seasoned and chemically treated hollock wood Cum 96,783.70 0.28 26,966.36
38 9.37 Providing and fixing plywood 4 mm thick, one side decorative
veneer conforming to IS: 1328 (type-1), for plain lining / cladding
with necessary screws, including priming coat on unexposed
surface with : - -
9.37.1 Decorative veneer facings of approved manufacture Sqm 1,156.20 91.80 106,139.16
39 9.40 Providing and fixing wooden moulded beading to door and
window frames with iron screws, plugs and priming coat on
unexposed surface etc. complete : - -
9.40.1 2nd class teak wood - -
40 9.47 Providing and fixing nickel plated M.S. pipe curtain rods with
nickel plated brackets : - -
42 9.60 Providing and fixing oxidised M.S. double acting spring hinges
with necessary screws etc. complete. - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
43 9.70 Providing and fixing IS : 12817 marked stainless steel butt
hinges with stainless steel screws etc. complete : - -
44 9.87 Providing and fixing bright finished brass hasp and staple (safety
type) with necessary screws etc. complete : - -
45 9.90 Providing and fixing special quality chromium plated brass
cupboard locks with six levers of approved quality including
necessary screws etc. complete. - -
46 9.96 Providing and fixing aluminium sliding door bolts ISI marked
anodised (anodic coating not less than grade AC 10 as per IS:
1868) transparent or dyed to required colour or shade with nuts
and screws etc. complete:
47 9.97 Providing and fixing aluminium tower bolts ISI marked anodised
(anodic coating not less than grade AC 10 as per IS: 1868)
transparent or dyed to required colour or shade with necessary
screws etc. complete:
48 9.100 Providing and fixing aluminium handles ISI marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour or shade with necessary
screws etc.complete:
49 9.101 Providing and fixing aluminium hanging floor door stopper ISI
marked anodised (anodic coating not less than grade AC 10 as
per IS:1868) transparent or dyed to required colour and shade
with necessary screws etc. complete.
9.101.2 Twin rubber stopper Each 83.95 114.00 9,570.30
50 9.102 Providing and fixing aluminium casement stays, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour and shade, with
necessary screws etc. complete. Each 74.95 80.00 5,996.00
51 9.112 Providing and fixing 2nd class teak wood lipping/ moulded
beading or taj beading of size 18X5 mm fixed with wooden
adhesive of approved quality and screws/ nails on the edges of
the Pre-laminated particle board as per direction of Engineer-in-
52 9.114 Providing and fixing magnetic catcher of approved quality in
cupboard / ward robe shutters, including fixing with necessary
screws etc. complete. - -
9.114.2 Double strip (horizontal type) Each 22.80 30.00 684.00
53 9.115 Providing and fixing powder coated telescopic drawer channels
300 mm long with necessary screws etc. complete as per
directions of Engineerincharge. One set 198.95 15.00 2,984.25
54 9.119 Providing and fixing factory made P.V.C. door frame of size
50x47 mm with a wall thickness of 5 mm, made out of extruded
5mm rigid PVC foam sheet, mitred at corners and joined with 2
Nos of 150 mm long brackets of 15x15 mm M.S. square tube,
the vertical door frame profiles to be reinforced with 19x19 mm
M.S. square tube of 19 gauge, EPDM rubber gasket weather
seal to be provided through out the frame. The door frame to be
fixed to the wall using M.S. screws of 65/100 mm size, complete
as per manufacturer‟s specification and direction of Engineerin-
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
55 9.120 Providing and fixing factory made panel PVC door shutter
consisting of frame made out of M.S. tubes of 19 gauge
thickness and size of 19 mm x 19 mm for styles and 15x15 mm
for top & bottom rails. M.S. frame shall have a coat of steel
primers of approved make and manufacture. M.S. frame
covered with 5 mm thick heat moulded PVC „C‟ channel of size
30 mm thickness, 70 mm width out of which 50 mm shall be flat
and 20 mm shall be tapered in 45 degree angle on both side
forming styles and 5 mm thick, 95 mm wide PVC sheet out of
which 75 mm shall be flat and 20 mm shall be tapered in 45
degree on the inner side to form top and bottom rail and 115 mm
wide PVC sheet out of which 75 mm shall be flat and 20 mm
shall be tapered on both sides to form lock rail. Top, bottom and
lock rails shall be provided both side of the panel. 10 mm (5 mm
x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap
insert for top rail & bottom rail, paneling of 5 mm thick both side
PVC sheet to be fitted in the M.S. frame welded/ sealed to the
styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC
sheet beading on inner side, and joined together with solvent
cement adhesive. An additional 5 mm thick PVC strip of 20 mm
width is to be stuck on the interior side of the „C‟ Channel using
PVC solvent adhesive etc. complete as per direction of Engineer- - -
9.120.2 in-charge,
30 mm thick manufacturer‟s
pre laminatedspecification & drawing.
PVC door shutters Sqm 3,214.20 5.00 16,071.00
56 9.136 Providing and fixing fire resistant door frame of section 143 x 57
mm having built in rebate made out of 16 SWG G.I. sheet (zinc
coating not less than 120 gm/sqm) duly filled with vermuculite
based concrete mix, suitable for mounting 60 minutes fire rated
door shutters. The frame is fitted with intumuscent fire seal strip
of size 10x4 mm (minimum) alround the frame and fixing with
dash fastener of approved size and make, including applying a
coat of approved brand fire resistant primer etc. complete as per
direction of Engineer-in-charge (Dash fastener to be paid for
57 9.137 Providing and fixing 50 mm thick glazed fire resistant door
shutters of 60 minutes fire rating conforming to IS:3614 (Part-II),
tested and certified as per laboratory approved by Engineer-in-
charge, with suitable mounting on door frame, consisting of
vertical styles, lock rail, top rail 100 mm wide, bottom rail 200
mm wide, made out of 16 SWG G.I.sheet (zinc coating not less
than 120 gm/m2) duly filled FR insulation material and fixing with
necessary stainless steel ball bearing hinges of approved make,
including applying a coat of approved fire resistant primer etc. all
complete as per direction of Engineer-in-charge (panneling to be
paid for separately).
58 9.138 Providing and fixing glazing in fire resistant door shutters, fixed
panels, ventilators and partitions etc., with G.I. beading of
appropriate size, made out of 20 SWG G.I.sheet (zinc coating
not less than 120 gm/m2), fire resistant sealant, including
applying a coat of approved fire resistant primer on G.I. beading
etc., complete all as per direction of Engineer-in-charge.
9.138.1 With clear fire resistant glass panes 6mm thick of approved
brand, having minimum 60 minutes fire resistance Sqm 27,658.70 2.16 59,742.79
59 9.139 Providing and fixing panic bar / latch (Double point) fitted with a
single body, Trim Latch & Lock on back side of the Panic Latch
of reputed brand and manufacture to be approved by the
Engineer- in- charge, all complete. Each 6,133.20 12.00 73,598.40
60 9.157 Providing and fixing Pre-laminated medium density fibre board
IS: 14587:1998 marked, with one side decorative lamination
other side balancing lamination Grade-I(exterior grade) in
shelves with screws and fittings wherever required, edges to be
sealed with PVC edge bending tape 2.00 mm thick of approved
brand (fittings to be paid separately). - -
9.157.1 Pre-laminated with decorative lamination one side and other
side balancing lamination exterior Grade - I MDF Board 18 mm
thick confirming to IS:14587 Sqm 1,394.55 83.40 116,305.47
61 9.159 Providing and fixing 25mm thick pre-laminated medium density
fibre board exterior grade ( Grade-I) IS:14587:1998 marked one
side decorative and other side balancing lamination for cupboard
shutters edges to be sealed with PVC edge bending tape 2.00
mm thick of approved brand including ISI marked nickeled
plated bright finishing M.S. piano hinges IS:3818 marked with
necessary screwed complete. Sqm 1,883.00 36.00 67,788.00
SH: 10, STEEL WORKS - -
62 10.5 Providing and fixing 1mm thick M.S. sheet door with frame of
40x40x6 mm angle iron and 3 mm M.S. gusset plates at the
junctions and corners, all necessary fittings complete, including
applying a priming coat of approved steel primer. - -
10.5.2 Using flats 30x6mm for diagonal braces and central cross piece
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
63 10.13 Providing and fixing T-iron frames for doors, windows and
ventilators of mild steel Tee-sections, joints mitred and welded,
including fixing of necessary butt hinges and screws and
applying a priming coat of approved steel primer. - -
10.13.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement
concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse
sand : 6 graded stone aggregate 20 mm nominal size) Kg 83.70 10.00 837.00
64 10.25 Steel work welded in built up sections/ framed work, including
cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates
and similar works Kg 90.10 859.13 77,407.79
65 10.28 Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and
fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories &
stainless steel dash fasteners , stainless steel bolts etc., of
required size, on the top of the floor or the side of waist slab with
suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall
be considered excluding fixing accessories such as nuts, bolts,
fasteners etc.).
10.28 Work already executed by the previous agency
10.28 Balance Work (Cleaning, Polishing, Repairing , Replacement or
any other works required for final hand over to NBCC / Client at
their satisfaction) Kg 30.97 1,123.68 34,800.37
SH: 11 & 16, FLOORING & ROAD WORK - -
66 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate) finished with a floating coat of neat
cement, including cement slurry, but excluding the cost of nosing
of steps etc. complete. - -
11.3.1 40 mm thick with 20 mm nominal size stone aggregate Sqm 353.35 8.40 2,968.14
67 11.4 52 mm thick cement concrete flooring with concrete hardener
topping, under layer 40 mm thick cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and top layer 12 mm thick cement hardener
consisting of mix 1:2 (1 cement hardener mix : 2 graded stone
aggregate 6 mm nominal size) by volume, hardening compound
mixed @ 2 litre per 50 kg of cement or as per manufacturer‟s
specifications. This includes cost of cement slurry, but excluding
the cost of nosing of steps etc. complete. Sqm 535.25 - -
68 11.26 Kota stone slab flooring over 20 mm (average) thick base laid
over and jointed with grey cement slurry mixed with pigment to
match the shade of the slab including rubbing and polishing
complete with base of 1:4 (1 cement :4 coarse sand):
69 11.27 Kota stone slabs 25 mm thick in risers of steps, skirting, dado
and pillars laid on 12 mm (average) thick cement mortar 1:3 (1
cement : 3 coarse sand) and jointed with grey cement slurry
mixed with pigment to match te shade of the slabs, including
rubbing and polishing complete.
70 11.36 Providing and fixing 1st quality ceramic glazed wall tiles
conforming to IS: 15622 (thickness to be specified by the
manufacture of approved make in all colours, shades except
burgundy, bottle green, black of any size as approved by
Engineer-in-charge in skirting. risers of steps and dados over 12
mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand)
and jointing with grey cement slurry @ 3.3kg per sqm including
pointing in white cement mixed with pigment of matching shade
71 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size
300x300 mm or more (thickness to be specified by the
manufacturer), of 1st quality conforming to IS : 15622, of
approved make, in colours White, Ivory, Grey, Fume Red Brown,
laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse
sand), including grouting the joints with white cement and
matching pigments etc., complete.
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
72 11.41 Providing and laying vitrified floor tiles in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS : 15622, of
approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), including
grouting the joints with white cement and matching pigments
etc., complete. - -
11.41.2 Supply of Tiles Sqm 913.87 - -
11.41.2 Laying of Tiles Sqm 421.79 - -
11.41.2 Balance work (Final rectification, cleaning, handing over or any
other works required to NBCC/Client to their satisfaction)
73 11.46 Providing and laying Vitrified tiles in different sizes (thickness to
be specified by manufacturer), with water absorption less than
0.08 % and conforming to I.S. 15622, of approved make, in all
colours & shade, in skirting, riser of steps, over 12 mm thick bed
of cement mortar 1:3 (1 cement: 3 coarse sand), including
grouting the joint with white cement & matching pigments etc.
complete. - -
74 11.47 Providing and laying Vitrified tiles in different sizes (thickness to
be specified by the manufacturer), with water absorption less
than 0.08% and conforming to IS: 15622, of approved brand &
manufacturer, in all colours and shade, in skirting, riser of steps,
laid with cement based high polymer modified quick set tile
adhesive (water based) conforming to IS: 15477, in average 6
mm thickness, including grouting of joints (Payment for grouting
of joints to be made separately). - -
75 16.48 Painting road surface marking with adequate nos of coats to
give uniform finish with ready mixed road marking paint
conforming to IS : 164, on bituminous surface in white/yellow
shade, including cleaning the surface of all dirt, scales, oil,
grease and foreign material etc. complete. - -
16.48.1 New work (Two or more coats) Sqm 122.15 13.47 1,645.36
76 16.68 Providing and laying 60mm thick factory made cement concrete
interlocking paver block of M -30 grade made by block making
machine with strong vibratory compaction, of approved size,
design & shape, laid in required colour and pattern over and
including 50mm thick compacted bed of coarse sand, filling the
joints with fine sand etc. all complete as per the direction of
Engineer-in-charge. Sqm 602.20 27.00 16,259.40
77 16.69 Providing and laying at or near ground level factory made kerb
stone of M- 25 grade cement concrete in position to the required
line, level and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarse sand), including making joints with or without
grooves (thickness of joints except at sharp curve shall not to
more than 5mm), including making drainage opening wherever
required complete etc. as per direction of Engineer-in-charge
(length of finished kerb edging shall be measured for payment).
SH: 12, ROOFING - -
78 12.22 Making khurras 45x45 cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m
x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding
the edges and making and finishing the outlet complete.
79 12.45 Providing and fixing false ceiling at all height including providing
and fixing of frame work made of special sections, power
pressed from M.S. sheets and galvanized with zinc coating of
120 gms/sqm (both side inclusive) as per IS : 277 and consisting
of angle cleats of size 25 mm wide x 1.6 mm thick with flanges
of 27 mm and 37mm, at 1200 mm centre to centre, one flange
fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long
with 6mm dia bolts, other flange of cleat fixed to the angle - -
12.45.1 hangers
tapered edge required
plain boardwith nuts & bolts
12.45.1 Balance Work (Rectifiaction, Set right the grid channel and
fixing of false ceiling of gypsum board or any other works
required to NBCC / Client at their satisfaction) Sqm 453.55 180.81 82,008.08
12.45.1 Work already executed by the previous agency Sqm 453.55 882.45 400,235.20
SH: 13.0 & 19.0, FINISHING & DRAINAGE - -
80 13.1 12 mm cement plaster of mix : - -
81 13.2 15 mm cement plaster on the rough side of single or half brick
wall of mix: - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
82 13.4 12 mm cement plaster of mix: - -
13.4.1 1:4 (1 cement: 4 coarse sand) Sqm 172.30 - -
83 13.5 15 mm cement plaster on rough side of single or half brick wall
13.5.1 1:4 (1 cement: 4 coarse sand) Sqm 200.05 - -
84 13.16 6 mm cement plaster of mix: - -
13.16.1 1:3 (1 cement: 3 fine sand) Sqm 134.70 - -
85 13.22 Extra for plastering exterior walls of height more than 10 m from
ground level for every additional height of 3 m or part thereof.
i) HT more than 10.0m upto 13.0m Sqm 37.95 - -
ii) HT more than 13.0 m upto 16.0m Sqm 75.90 - -
iii) HT more than 16.0m upto 19.0m Sqm 113.85 - -
iv) HT more than 19.0m upto 22.0m Sqm 151.80 - -
v) HT more than 22.0m upto 25.0m Sqm 189.75 - -
86 13.41 Distempering with oil bound washable distemper of approved
brand and manufacture to give an even shade - -
13.41.1 New work (tow or more coats) over and including priming coat
with cement primer.
87 13.43 Applying one coat of water thinnable cement primer of approved
brand and manufacture on wall surface : - -
13.43.1 Water thinnable cement primer Sqm 35.85 25.00 896.25
88 13.45 Finishing walls with textured exterior paint of required shade :
13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over
and including priming coat of exterior primer applied @ 2.20kg/
89 13.46 Finishing walls with Acrylic Smooth exterior paint of required
13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and
including priming coat of exterior primer applied @ 2.20 kg/ 10
90 13.60 Wall painting with acrylic emulsion paint of approved brand and
manufacture to give an even shade : - -
13.60.1 Two or more coats on new work Sqm 80.50 10,984.42 884,245.89
91 13.61 Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade: - -
13.61.1 Two or more coats on new work Sqm 74.40 196.33 14,606.95
92 13.68 French spirit polishing : - -
13.68.1 Two or more coats on new works including a coat of wood filler
93 13.26 Providing and applying plaster of paris putty of 2 mm thickness
over plastered surface to prepare the surface even and smooth
complete Sqm 110.95 - -
13.26 1 coat putty already done. 2nd coat putty to be done. Sqm 83.21 - -
13.26 Balance work (Final rectification, cleaning, handing over or any
other works required to NBCC/Client to their satisfaction)
94 13.80 Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
complete. Sqm 89.65 10.00 896.50
95 19.16 Providing orange colour safety foot rest of minimum 6 mm thick
plastic encapsulated as per IS : 10910, on 12 mm dia steel bar
conforming to IS: 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as
165 mm with minimum 112 mm space between protruded legs
having 2 mm tread on top surface by ribbing or chequering
besides necessary and adequate anchoring projections on tail
length on 138 mm as per standard drawing and suitable to with
stand the bend test and chemical resistance test as per
specifications and having manufacture‟s permanent identification
mark to be visible even after fixing, including fixing in manholes
with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal size)
complete as per design. Each 311.60 24.00 7,478.40
96 19.18 Supplying and fixing C.I. cover without frame for manholes : - -
19.18.1 455 x 610 mm rectangular C.I. cover (light duty) the weight of the
cover to be not less than 23 kg Each 1,222.15 - -
SH: 20.0, PILE WORK - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
97 20.2 Boring, providing and installation bored cast-in-situ reinforced
cement concrete piles of grade M-25 of specified diameter and
length below the pile cap, to carry a safe working load not less
than specified, excluding the cost of steel reinforcement but
including the cost of boring with bentonite solution and
temporary casing of appropriate length for setting out and
removal of same and the length of the pile to be embedded in
the pile cap etc. by percussion drilling using Direct mud
circulation (DMC) or Bailer and chisel technique by tripod and
mechanical Winch Machine all complete, including removal of
excavated earth with all its lifts and leads (length of pile for
payment shall be measured up to bottom of pile cap). - -
Note: Truck Mounted rotary/TMR/Tubewell boring mchine
shall not be used . - -
20.2.5 600 mm dia. Piles metre 2,671.00 - -
98 20.6 Vertical load testing of piles in accordance with IS 2911 (Part IV)
including installation of loading platform by Kentledge method
and preparation of pile head or construction of test cap and
dismantling of test cap after test etc. complete as per
specification & the direction of Engineer in-charge.
Note: 1. Initial and Routine Load Test shall not be carried
out by Dynamic method of testing. - -
Note 2: Testing agency shall submit the design of loading
platform for the approval of Engineer-in-charge.
20.6.3 Group of two or more piles upto 50 tonne Safe capacity - -
20.6.3.1 Initial test (Test Load 2.5 times the Safe capacity) Per Test 56,332.80 - -
20.6.3.2 Routine test (Test Load 1.5 times the Safe capacity) Per Test 34,264.20 - -
SH: 21.0, ALUMINIUM WORK - -
99 21.1 Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard tubular
sections/ appropriate Z sections and other sections of approved
make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up
the gaps at junctions, i.e. at top, bottom and sides with required
EPDM rubber/ neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed mechanically
wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel
screws, all complete as per architectural drawings and the
directions of Engineer-in-charge. (Glazing, paneling and dash
fasteners to be paid for separately) : - -
21.1.1 For fixed portion - -
21.1.1.2 Powder coated aluminium (minimum thickness of powder
coating 50 micron) Kg 377.75 - -
21.1.1.2 Work already executed by the previous agency Kg 321.09 724.63 232,668.99
21.1.1.2 Balance work (Door frames, window frames available at site,
installation, fixing as per specs or any other works required to be
done for handing over to NBCC/Client to their satisfaction)
100 21.1.2 For shutters of doors, windows & ventilators including providing
and fixing hinges/ pivots and making provision for fixing of
fittings wherever required including the cost of EPDM rubber /
neoprene gasket required (Fittings shall be paid for separately)
21.1.2.2 Powder coated aluminium (minimum thickness of powder
coating 50 micron) Kg 435.75 - -
21.1.2.2 Work already executed by the previous agency Kg 370.39 - -
21.1.2.2 Balance work (Shutters are available at site, installation, fixing
as per specs to be done for handing over to NBCC/Client to
their satisfaction) Kg 65.36 317.53 20,754.55
101 21.3 Providing and fixing glazing in aluminium door, window,
ventilator shutters and partitions etc. with EPDM rubber /
neoprene gasket etc. complete as per the architectural drawings
and the directions of engineer-in-charge. - -
21.3.1 With float glass panes of 4.0 mm thickness Sqm 828.75 65.53 54,307.99
21.3.2 With float glass panes of 5.50 mm thickness Sqm 1,054.20 - -
21.3.2 Work already executed by the previous agency Sqm 896.07 - -
21.3.2 Balance work (Glass panes is available at site
Installation, fixing as per specs or any other works required to be
done for handing over to NBCC/Client to their satisfaction)
102 21.13 Providing and fixing 100mm brass locks (best make of approved
quality) for aluminium doors including necessary cutting and
making good etc. complete. Each 418.65 1.00 418.65
103 21.16 Providing and fixing aluminium round shape handle of outer dia
100 mm with SS screws etc. complete as per direction of
Engineer in-charge - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
21.16.2 Powder coated minimum thickness 50 micron aluminium Each 72.60 4.00 290.40
104 21.17 Providing and fixing anodised aluminium grill (anodised
transparent or dyed to required shade according to IS: 1868 with
minimum anodic coating of grade AC 15) of approved
design/pattern, with approved standard section and fixed to the
existing window frame with C.P. brass/ stainless steel screws @
200 mm centre to centre, including cutting the grill to proper
opening size for fixing and operation of handles and fixing
approved anodised aluminium standard section around the
opening, all complete as per requirement and direction of
Engineer-in-charge. (Only weight of grill to be measured for
105 21.18 Providing and fixing 12 mm thick frameless toughened glass
door shutter of approved brand and manufacture, including
providing and fixing top & bottom pivot & spring type fixing
arrangement and making necessary holes etc. for fixing required
door fittings, all complete as per direction of Engineer-in-charge
(Door handle, lock and stopper etc.to be paid separately).
SH: 22.0, WATER PROOFING WORKS - -
106 22.3 Providing and laying water proofing treatment to vertical and
horizontal surfaces of depressed portions of W.C., kitchen and
the like consisting of: - -
i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with
water prrofing compound conforming to IS 2645 in
recommended proportions including rounding of junction of
vertical and horizontal surface.
ii) 2nd course of 20mm cement plaster 1:3 (1 cement : 3 coarse
sand) mixed with water proofing compound in recommended
proportio nincluding rounding off junction of vertical and
horizontal surface.
iii) 3rd course of applying blown or residual bitumen applied hot
at 1.7 kg. per sqm area.
iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints
of PVC sheet should be 100 mm wide and pasted to each other Sqm 522.90 - -
already@ 1.7 kg/sqm.)
executed by the previous agency Sqm 496.76 0.00 0.25
22.3 Balance work (Repairing, rectifcation of already installed
waterproofing along with submission of water proofing bond ,or
any other works required for handing over to NBCC/Client to
their satisfaction) Sqm 26.15 443.54 11,596.38
107 22.20 Providing and laying APP (Atactic Polypropylene Polymer)
modified prefabricated five layer 3 mm thick water proofing
membrane, black finished reinforced with non-woven polyester
matt consisting of a coat of bitumen primer for bitumen
membrane @ 0.40 litre/sqm by the same membrane
manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity
70-160 cps. Over the primer coat the layer of membrane shall be
laid using Butane Torch and sealing all joints etc, and preparing
the surface complete. The vital physical and chemical
parameters of the membrane shall be as under : Joint strength
in longitudinal and transverse direction at 23°C as 650/
450N/5cm. Tear strength in longitudinal and transverse direction
as 300/250N. Softening point of membrane not less than 150°C.
Cold flexibility shall be upto -2°C when tested in accordance with
ASTM, D - 5147. The laying of membrane shall be got done
through the authorised applicator of the manufacturer of - -
22.20.1 membrane
3 mm thick : Sqm 425.35 - -
22.20.1 Work already executed by the previous agency Sqm 404.08 - -
22.20.1 Balance work (Repairing, rectifcation of already installed
waterproofing along with submission of water proofing bond ,or
any other works required for handing over to NBCC/Client to
their satisfaction) Sqm 21.27 633.27 13,468.07
108 22.21 Extra for covering top of membrane with Geotextile, 120 gsm
non woven, 100% polyester of thickness 1 to 1.25 mm bonded
to the membrane with intermittent touch by heating the
membrane by Butane Torch as per manufactures
recommendation. 74.85 - -
22.21 Work already executed by the previous agency Sqm 71.11 - -
22.21 Balance work (Repairing, rectifcation of already installed
waterproofing along with submission of water proofing bond ,or
any other works required for handing over to NBCC/Client to
their satisfaction) Sqm 3.74 633.27 2,370.01
109 26.7 Designing, fabricating, testing, installing and fixing in position
Curtain Wall with Aluminium Composite Panel Cladding, with
open grooves for linear as well as curvilinear portions of the
building, for all heights and all levels etc. including:
a) Structural analysis & design and preparation of shop drawings
for pressure equalisation or rain screen principle as required,
proper drainage of water to make it watertight including checking
of all the structural and functional design. - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
b) Providing, fabricating and supplying and fixing panels of
aluminium composite panel cladding in pan shape in metalic
colour of approved shades made out of 4mm thick aluminium
composite panel material consisting of 3mm thick FR grade
mineral core sandwiched between two Aluminium sheets (each
0.5mm thick). The aluminium composite panel cladding sheet
shall be coil coated, with Kynar 500 based PVDF / Lumiflon
based fluoropolymer resin coating of approved colour and shade
on face # 1 and polymer (Service) coating on face # 2 as
specified using stainless steel screws, nuts, bolts, washers,
cleats, weather silicone sealant, backer rods etc.
c) The fastening brackets of Aluminium alloy 6005 T5 / MS with
Hot Dip Galvanised with serrations and serrated washers to
arrest the wind load movement, fasteners, SS 316 Pins and
anchor bolts of approved make in SS 316, Nylon separators to
prevent bi-metallic contacts all complete required to perform as
per specification and drawing The item includes cost of all
material & labour component, the cost of all mock ups at site,
cost of all samples of the individual components for testing in an
approved laboratory, field tests on the assembled working
curtain wall with aluminium composite panel cladding, cleaning
and protection of the curtain wall with aluminium composite
panel cladding till the handing over of the building for
occupation. Base frame work for ACP cladding is payable under
the relevant aluminium item.s The Contractor shall provide
curtain wall with aluminium composite panel cladding, having all
the performance characteristics all complete , as per the
Architectural drawings, as per item description, as specified, as
per the approved shop drawings and as directed by the Engineer-
in-Charge. However, for the purpose of payment, only the actual
area on the external face of the curtain wall with Aluminum
Composite Panel Cladding (including width of groove) shall be
measured in sqm. up to two decimal places.
PART-II : NON SCHEDULE ITEMS - -
N: NON-SCHEDULE ITEMS - -
110 MR ANTI-TERMITE TREATMENT
Diluting and injecting chemical emulsion for PRE-
CONSTRUCTIONAL Anti-termite treatment and creating a
continous chemical barrier , wall trenches, top surface of plinth
filling, along the external perimeter of building, over the top
surface of consolidated earth of which apron is to be laid,
surroundings of pipes and conduits etc. complete as per
specification. (Plinth area of the building at ground floor only
shall be measured for payment). Chlorpyriphos Emulsifiable
concentrate of 20% with 1% Concentration. i.e. mateiral
chlorpyriphos/ lindane etc complete
111 MR GRC JALI
Providing and fixing Glass Reinforced Concrete (G.R.C)
Screens in approved size, pattern, design, thickness and color of
M/S UniStone make or equivalent. The Screens should be made
from „53 grade‟ White Portland Cement manufactured by „JK
Cement‟ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant
Glass Fiber manufactured by „Saint Gobain‟ or equivalent, Super
Plasticizers manufactured by „BASF‟ or equivalent, Polymers
manufactured by „BASF‟ or equivalent and U.V resistant
Synthetic inorganic pigments should be used for pigmentation
manufactured by „BAYFERROX (Germany)‟ or equivalent. The
material casting should take place in Synthetic Rubber / FRP
Mould manufactured by „Reckli‟ or equivalent. The fixing of
Screens should be „Dry fixing‟ i.e. to be done with Stainless
Steel (SS – 304) „L‟ shaped Clamps, dash fasteners and pins.
etc. complete as per directed by Engineer-in-Charge.
112 MR STRUCTURE GLAZING
Supply & fixing of structural glazing for fixed & Openable (upto
all floors) at Façade using glazing section of which mullion &
transom to be aluminum grade of 63400 WP and ISI 7733 and
ID 1258 section size 112x55x2 mm. (SP 3584) Electro colour
anodized 20 micron or pure polyester powder coated 40 micron
of approved shade and colour using AIS ( Asahi India)- 6mm
thick Toughened single glazed reflective high performance
offline coated AIS (Sunergy-Green) glass or equivalent.having
light transmission minimum 56% solar factor maximum 41%
External reflection 7% , Internal Reflection 10% and U value of
maximum 4.1 W/m2. Glass shall be fixed by sub frame method
on 19x19 x 2 mm Aluminum Square tube with help of 12mm x 6
mm both side rubber spacer & structural silicon of Dow Corning
995 grade. The Weather /water sealing of glass joints shall be
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
MR Work already executed by the previous agency
(Fixing, Repairing , or any other works required to handing over
to client with full completion) Sqm 1,506.15 450.66 678,769.26
MR Balance work
(Fixing, Repairing or any other work required for handing over to
client with full completion handing over to NBCC/Client to their
satisfaction) Sqm 3,916.00 488.16 1,911,650.06
MR Balance work
(Repairing and handing over or any other work required for
handing over to NBCC/Client to their satisfaction) Sqm 602.46 606.44 365,356.74
113 MR HPL Wall Cladding
Supply FunderMax 6mm thick Exterior grade F- Quality panels of
standard size with both side décor. The panels should be
duromer high pressure laminates (HPL) in accordance with
EN438-6 TYPE EDF with Norm Conformity as per EN 438/7.
Installation of FunderMax panels will be done by MBE
Rivets(with Fixed and Sliding Points) with minimum
recommended Aluminum Box section of 38x38x2mm thick and
38x74x2mm thick held by Wind load and Dead load MS
Galvanized brackets as per design, anchored by standard
Hilti/Fischer or equivalent make anchor fasteners along with
Thermal and Bi-Metallic Separator. Installation of FunderMax
Panels will be done using Rear Ventilated Principles only .which
is ensured by providing gaps of 20 mm at top and bottom(for
free flow of air behind the façade) for the façade and using the
framework with no horizontal section. Sqm 10,111.89 5.00 50,559.43
114 MR Providing and fixing Antiskid Heavy duty unglazed vitrified Floor
tiles 300x300mm and 10mm thick laid on 20mm thick cement
mortar 1:4 (1 cement : 4 coarse sand) with Tile Adhesive [3-
4mm thickness] and jointing with Tile Grout as per approved
colour & shade as approved by Engineer-in charge. Sqm 1,188.57 200.00 237,714.09
INTERNAL PLUMBING WORKS - -
SUBHEAD-I (A): SANITARY INSTALLATIONS ( SCHEDULED ITEMS) - -
115 17.20 Providing and fixing white vitreous china pedestal type water
closet (European type W.C. pan) with seat and lid, 10 litre low
level white P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever), conforming to IS :
7231, with all fittings and fixtures complete, including cutting and
making good the walls and floors wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic seat and lid Each 3,317.30 33.00 109,470.90
116 17.70 Providing and fixing wash basin with C.I.brackets, 15 mm C.P.
brass pillar taps, 32 mm C.P. brass waste of standard pattern,
including painting of fittings and brackets, cutting and making
good the walls wherever require : - -
17.7.1 White Vitreous China flat back wash basin size 630 x 450 mm
with a pair of 15 mm C.P. brass pillar taps. Each 2,331.15 41.00 95,577.15
117 8.10 Providing & fixing stone slab table rubbed, edges rounded and
polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal
patitions by cutting chase of appropriate width with chase cutter
and embedding the stone in chase with epoxy grout or with
cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded
stone aggregste 6mm nominal size) as per Engineer-in-charge
and finished smooth - -
8.10.1 White Agaria Marble Stone sqm 3,263.50 10.00 32,635.00
118 17.80 Providing and fixing white vitreous china battery based infrared
sensor operated urinal of approx. size 610 x 390 x 370 mm
having pre & post flushing with water ( 250 ml & 500 ml
consumption), having water inlet from back side, including fixing
to wall with suitable brackets all as per manufacturers
specification and direction of Engineer-in-charge..
119 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink
as per IS: 13983 with CI brackets and stainless steel plug 40mm
including painting of fittings and brackets, cutting and making
good the walls wherever required. - -
17.10.1 Kitchen sink with drain board - -
17.10.2 Kitchen Sink without drain board (For JC) - -
120 17.28 Providing & fixing PVC waste pipe for sink or wash basin
including PVC waste fitting Complete - -
17.28.2 Flexible Pipe - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
121 17.32 Providing and fixing mirror of superior glass (of approved quality)
and of required shape and size with plastic moulded frame of
approved make and shade with 6 mm thick hard board backing :
17.32.2 Rectangular shape 453x357 mm Each 727.90 41.00 29,843.90
122 17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
17.70.1 Bottle trap 31 mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the waste
coupling 77 mm breadth with 25 mm minimum water seal,
weighing not less than 260 gms. Each 494.90 39.00 19,301.10
17.70.2 Bottle trap 38 mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the waste
coupling 77 mm breadth with 25 mm minimum water seal,
weighing not less than 260 gms.(sink & urinal) Each 518.15 11.00 5,699.65
123 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,
125 mm high and 112 mm distance from wall of standard shape
with bracket of the same materials with snap fittings of approved
quality and colour weighing not less than 105 gms.
124 17.72 Providing & fixing PTMT towel ring trapezoidal shape 215 mm
long 200 mm wide with minimum distance of 37 mm from wall
face with concealed fittings arrangement of approved quality
and colour weighing not less than 88 gms Each 218.50 39.00 8,521.50
125 18.49 Providing and fixing C.P. brass bib cock of approved quality
confirming to IS:8931 - -
126 18.51 Providing and fixing C.P. brass long body bib cock of approved
quality conforming to IS standards and weighing not less than
18.51.1 15mm nominal bore Each 610.65 7.00 4,274.55
127 18.53 Providing and fixing C.P. brass angle valve for basin mixer and
geyser points of approved quality conforming to IS 8931 a) 15
mm nominal bore. - -
128 17.34 Providing and fixing toilet paper holder : - -
129 18.64 Providing & fixing PTMT swivelling shower, 15mm nominal
bore.weighing not less than 40 gms. Each 141.75 7.00 992.25
130 17.73 Providing and fixing PTMT towel rail complete with brackets
fixed wooden cleats with CP brass screws with concealed fittings
arrangement of approved quality and colour. - -
17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm
and effective height of 88 mm, weighing not less than 190 gms
SUBHEAD-I(B): SANITARY INSTALLATIONS (NON-SCHEDULED ITEMS) - -
131 MR Supplying, storing, handling, shifting, installation, testing and
commissioning of CP flxible hose, spray, wall flange etc.
complete.(Make: Jaquar Model No- 573 or equivalent)
132 MR Recieving, storing, handling, shifting, installation, testing and
commissioning of C.P. brass shower arm with wall flange.
(Make: Jaquar Model No- SHA 477 or equivalent)
133 MR Supplying, storing, handling, shifting, installation, testing and
commissioning of C.P. head shower set comprising head
shower with ball joint adjustable shower jet. (Make : Jaquar,
Model - OHS 1989 or equivalent) Each 1,428.69 7.00 10,000.86
134 MR Supplying, storing, handling, shifting, installation, testing and
commissioning of Wall Mixer 3-in-1 System with Provision for
both Hand Shower and Overhead Shower Complete with
115mm Long Bend Pipe, Connecting Legs & Wall
Flangeconnection to shower & bath with all accessories of
approved design. (Make: Jaquar Model No.- FUS-29281 or
equivalent) Each 3,997.76 7.00 27,984.34
135 MR Providing and fixing C.P brass central hole basin mixer
complete in respects.(Basin Mixer Jaquar, Model: Florentine,
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
136 MR Providing and fixing 15mm dia C.P. brass wall-mounted central
hole sink mixer with swinging spout of approved make and
quality with all fittings and accessories etc. complete.(Sink
mixer Jaquar mixer Model FLR-5163 Each 3,098.37 2.00 6,196.75
SUBHEAD-II(A): INTERNAL DRAINAGE INSTALLATIONS (SCHEDULED ITEMS) - -
137 17.60 Providing and fixing cast iron trap of self cleansing design with
cast iron screwed down or hinged grating with or without vent
arm complete, including cost of cutting and making good the
walls and floors. - -
17.60.1 100 mm inlet and 100 mm outlet centrifugally cast (spun) iron
17.60.1 Work already executed by the previous agency Each 835.17 - -
17.60.1 Balancework (Repairing, Testing or any other work required to
be done for final hand over to NBCC / Client at their
satisfaction) Each 147.38 49.00 7,221.74
138 12.22 Making khurras 45x45cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded
stone aggregate 20 mm nominal size) over PVC sheet 1m x 1m
x 400 micron, finished with 12mm cement plaster 1:3 (1
cement:3 coarse sand) and a coat of neat cement, rounding the
edges, making and finishing the outlet complete
139 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron
grating 15 cm diameter and weighing not less than 440 grams.
140 17.35 Providing and fixing soil, waste, vent and rain water pipes - -
17.35.1.2 Centrifugally cast (spun) iron socket & spigot (S&S ) pipe as per
17.35.1.2 Work already executed by the previous agency metre 780.09 - -
17.35.1.2 Balance work (Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) metre 137.66 657.10 90,458.03
141 17.37 Providing and fixing MS holder bat clamps of approved design to
cast iron (spun) pipe embedded in and Including cement
concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) including
cost of cutting holes and making good the walls etc.
17.37.1 For 100mm dia. Pipe Each 152.90 - -
17.37.1 Work already executed by the previous agency Each 129.97 - -
17.37.1 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) Each 22.94 328.55 7,535.29
142 17.38 Providing and fixing bend of required degree with access door,
insertion rubber washer 3mm thick, bolts and nuts complete.
17.38.1.2 Centrifugally cast (spun) iron pipe S&S as per IS-3989 Each 385.70 - -
17.38.1.2 Work already executed by the previous agency Each 327.85 - -
17.38.1.2 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) Each 57.86 41.00 2,372.06
143 17.39 Providing and fixing plain bend of required degree. - -
17.39.1.2 Sand cast iron S&S as per IS : 3989 Each 335.75 - -
17.39.1.2 Work already executed by the previous agency Each 285.39 - -
17.39.1.2 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) Each 50.36 86.00 4,331.18
144 17.40.1.2 Providing and fixing heel rest sanitary bend, in 100mm
Centrifugally cast (spun) iron pipe S&S as per IS-3989 Each 371.75 - -
17.40.1.2 Work already executed by the previous agency Each 315.99 - -
17.40.1.2 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) Each 55.76 49.00 2,732.36
145 17.42 Providing and fixing double equal plain junction of required
17.42.1.2 Sand cast iron S&S as per IS - 3989 Each 748.10 49.00 36,656.90
146 17.43 Providing and fixing single equal plain junction of reqd. degree
with access door, insertion rubber washer 3mm thick, bolts and
nuts complete. - -
17.43.1.2 Sand cast (spun) iron S&S as per IS-3989 Each 623.80 66.00 41,170.80
147 17.44 Providing and fixing single equal plain junction of required
17.44.1.2 Sand cast iron S&S as per IS - 3989 Each 576.20 - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
17.44.1.2 Work already executed by the previous agency Each 489.77 - -
17.44.1.2 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) Each 86.43 72.00 6,222.96
148 17.48 Providing and fixing single unequal plain junction of required
17.48.1.2 Sand cast iron S&S as per IS -3989 Each 690.00 20.00 13,800.00
149 17.55 Providing and fixing door piece, insertion rubber washer 3mm
thick, bolts & nuts complete : - -
17.55.1.2 Sand cast iron S&S as per IS: 3989 Each 513.45 15.00 7,701.75
150 17.56 Providing and fixing terminal guard: - -
17.56.1.2 Sand cast iron S&S as per IS - 3989 Each 434.50 7.00 3,041.50
151 17.57 Providing and fixing collar. - -
17.57.1.2 Sand (Centrifugally) cast (spun) iron pipe S&S as per IS-3989
152 17.65 Painting sand cast iron / centrifugally cast iron( spun) iron soil,
waste and vent pipes and fittings with two coats of synthetic
enamel paint of any colour such as chocolate, grey or buff etc.
over a coat of primer (of approval quality) for new work
17.65.1 100mm dia cast (spun) iron S&S pipe metre 38.65 - -
17.65.1 Work already executed by the previous agency metre 32.85 - -
17.65.1 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) metre 5.80 657.10 3,809.54
153 18.28 Providing lead caulked joints to spun iron or C.I. pipes and
specials, including testing of joints but excluding the cost of pig
18.28.1 100 & 150 mm diameter pipe Each 204.85 - -
18.28.1 Work already executed by the previous agency Each 174.12 - -
18.28.1 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) Each 30.73 650.00 19,972.88
154 18.58 Providing and fixing PTMT grating of approved quality and
18.58.1 Circular type - -
18.58.1.1 100 mm nominal dia Each 49.25 - -
18.58.1.1 Work already executed by the previous agency Each 41.86 2.00 83.72
18.58.1.1 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) Each 7.39 51.00 376.76
155 19.20 Providing and laying cement concrete 1:5:10 (1 cement: 5
coarse sand: 10 graded stone aggregate 40 mm nominal size)
all-round SW pipes including bed concrete as per standard
19.2.1 100mm diameter S.W. pipe metre 592.60 50.00 29,630.00
156 18.10 Providing and fixing G.I. Pipes complete with G.I. Fittings and
clamps. including cutting and making good the walls etc.
required for waste connection from W.B., A.S.P., Sump Rising
main etc. Complete.
Internal work -Exposed on wall - -
18.10.5 40 mm dia nominal bore metre 425.65 - -
18.10.5 Work already executed by the previous agency metre 361.80 - -
18.10.5 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) metre 63.85 151.07 9,645.44
18.10.6 50 mm dia nominal bore metre 527.20 5.00 2,636.00
157 18.40 Painting G.I. Pipes and fittings with two coats of anticorrosive
bitumastic paint of approved quality - -
18.40.5 40 mm diametre pipe metre 11.85 - -
18.40.6 50 mm diametre pipe metre 14.15 60.00 849.00
158 12.41 Providing & fixing on wall face unplasticised -Rigid PVC rain
water pipes conforming to IS:13592 Tyape A including jointing
with seal ring conforning to IS:5382 leaving 10 mm gap for
thermal expansion. (i) Single socketed pipes. - -
12.41.2 110 mm diameter metre 231.65 - -
12.41.2 Work already executed by the previous agency metre 196.90 - -
12.41.2 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) metre 34.75 482.56 16,767.75
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
12.42. Providing, fixing on wall face unplasticised - PVC moulded
fittings /accessories for unplasticised - Rigid PVC rain water
pipes conforming to IS ; 13592 Type A including jointing with
seal ring conforming to IS ; 5382 leaving 10 mm gap for thermal
expansion. - -
12.42.1.2 Coupler -110 mm diameter Each 138.30 - -
12.42.5.2 Bend -87.5 deg -110 mm diameter Each 161.55 - -
12.42.6.2 Shoe -110mm shoe Each 295.10 - -
159 12.43 Providing & fixing unplasticised - PVC pipe clips of approved
design to unplasticised - PVC rain water pipes by means of
50x50x50mm hard wood plugs, screwed with .M.S. screws of
required length including cutting brick work and fixing in cement
mortar 1:4(1cement : 4 coarse sand) and making good the wall
etc. complete. - -
12.43.2 Work already executed by the previous agency Each 160.69 - -
12.43.2 Balance work ( Repairing, Testing or any other work required to
be done for final handover to NBCC / Client at their
satisfaction) Each 28.36 241.28 6,842.10
SUBHEAD-II(B): INTERNAL DRAINAGE INSTALLATIONS (NON-SCHEDULED ITEMS) - -
160 M.R. Providing and fixing G.I. Inlet fitting of suitable size with 2 & 3
Nos. G.I. Socket 32 & 40 welded G.I. pipe and dipped in hot
bitumen complete in all respect. - -
100 mm diameter pipe (Hopper ) Each 993.20 - -
161 M.R Providing and fixing floor drain & balcony drain made of 100 x 50
dia elbow / tee as applicable connected with 50 dia GI pipe
painted with primer, two coats of black bituminastic
paint,wrapping 1 mm thick PVC tape and final coat of black
bituminastic paint B109 complete in all complete including
cutting and making good the walls and floor wherever required
162 M.R. Providing and fixing 100mm diameter C.P. Brass cleanout plug
with M.S. flanged tail pieces, 6mm dia nut & bolts, gasket and
washers fixed to C.I. Pipe with drip seal joint complete in all
complete including cutting and making good the walls and floor
wherever required. - -
with 100 mm dia. Pipe Each 1,210.95 3.00 3,632.84
SUBHEAD-III(A): WATER SUPPLY INSTALLATIONS (SCHEDULED ITEMS) - -
163 17.30 Providing and fixing in position 25 mm diameter mosquito proof
coupling of approved municipal design. Each 38.60 2.00 77.20
164 18.70 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes having thermal stability for hot and cold water supply
including all CPVC plain and brass threaded fittings including
fixing the pipe with clamps at 1.00 mt spacing. this includes
jointing of pipes and fittings with one step CPVC solvent cement
and testing of joints complete as per direction of engineer in
Internal work -Exposed on Wall - -
18.7.1 15 mm nominal outer dia pipes metre 163.50 5.00 817.50
18.7.2 20 mm nominal outer dia pipes metre 190.55 101.36 19,314.15
18.7.3 25 mm nominal outer dia pipes metre 231.30 43.40 10,038.42
18.7.4 32 mm nominal outer dia pipes metre 296.70 3.20 949.44
18.7.5 40 mm nominal outer dia pipes metre 407.90 - -
18.7.6 50 mm nominal outer dia pipes metre 581.55 10.00 5,815.50
165 18.80 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes having thermal stability for hot and cold water supply
including all CPVC plain and brass threaded fittings including
fixing the pipe with clamps at 1.00 mt spacing. this includes
jointing of pipes and fittings with one step CPVC solvent cement
and the cost of cutting chases and making good the wall same
including testing of joints complete as per the direction of
engineer incharge - -
Concealed work including cutting chases and making good the
wall etc. - -
18.8.1 15 mm nominal outer dia pipes metre 270.00 25.00 6,750.00
18.8.2 20 mm nominal outer dia pipes metre 296.40 - -
18.8.3 25 mm nominal outer dia pipes metre 351.30 37.00 12,998.10
18.8.4 32 mm nominal outer dia pipes metre 422.40 30.00 12,672.00
166 18.10 Providing and fixing G.I. pipes complete with GI fittings and
clamps including cutting and making good the walls etc. (internal
work) exposed on wall. - -
Internal work-Exposed on wall - -
18.10.1 15 mm dia, nominal bore metre 215.10 2.00 430.20
18.10.2 20 mm dia, nominal bore metre 249.30 2.00 498.60
18.10.3 25 mm dia, nominal bore metre 304.15 5.00 1,520.75
18.10.4 32 mm dia, nominal bore metre 343.20 5.00 1,716.00
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
18.10.5 40 mm dia, nominal bore metre 425.65 - -
18.10.6 50 mm dia, nominal bore metre 527.20 - -
167 Providing and fixing G.I. pipes complete with GI fittingsincluding
trenching and refilling etc. External Work:
18.12.7 65 mm dia, nominal bore metre 524.25 54.20 28,414.35
168 18.40 Painting GI pipes and fittings with two coats of anti corrosive
bitumastic paint of approved quality - -
18.40.1 15 mm dia, nominal bore metre 5.80 2.00 11.60
18.40.2 20 mm dia, nominal bore metre 6.85 2.00 13.70
18.40.3 25 mm dia, nominal bore metre 8.75 5.00 43.75
18.40.4 32 mm dia, nominal bore metre 10.40 5.00 52.00
18.40.5 40 mm dia, nominal bore metre 11.85 - -
18.40.6 50 mm dia, nominal bore metre 14.15 - -
18.40.7 65 mm dia, nominal bore metre 17.45 14.20 247.79
169 18.17 Providing and fixing of gun metal gate valve with CI wheel of
approved quality (screwed ends) - -
18.17.1 25mm dia, nominal bore Each 428.85 - -
18.17.2 32 mm dia, nominal bore Each 501.50 - -
18.17.3 40 mm dia, nominal bore Each 585.50 - -
18.17.4 50 mm dia, nominal bore Each 750.75 - -
170 18.19 Providing and fixing gun metal non- return valve of approved
quality (Screwed end) (PN 1.6) - -
18.19.5.2 65 nominal bore (Vertical) Each 2,025.15 - -
171 18.16.2 Providing and fixing brass stop cock of approved quality : 20mm
nominal bore Each 344.85 25.00 8,621.25
172 10.20 Structual steel work riveted, bolted or welded in built up
sections, trusses and framed work including cutting, hoisting,
fixing in position and applying a priming coat of approved steel
primer all complete.
173 18.46 Providing and fixing G.I. union in G.I. pipe including cutting and
threading the pipe and making long screws etc. complete (new
18.46.1 15mm nominal bore Each 165.25 2.00 330.50
18.46.2 20mm nominal bore Each 188.50 1.00 188.50
18.46.3 25mm nominal bore Each 200.10 2.00 400.20
18.46.4 32mm nominal bore Each 240.75 2.00 481.50
18.46.5 40mm nominal bore Each 316.25 1.00 316.25
18.46.6 50mm nominal bore Each 392.40 - -
174 18.48 Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, ISI : 12701 marked, with cover and suitable
locking arrangement and making necessary holes for inlet, outlet
and overflow pipes but without fittings and the base support for
175 18.33.1 Constructing masonry chamber 60x60x75 cm, inside with 75
class designation brick work in cement mortar 1:4 (1 cement:4
fine sand) for sluice valve, with C.I. surface box 100mm, to
diameter, 160mm bottom diameter and 180mm deep (inside)
with chained lid and RCC top slab 1:2:4 mix (1 cement : 2
corase sand: 4 graded stonr aggregate 20mm nominal size)
necessary excavation, foundation concret 1:5:10 (1 cement:5
fine sand : 10 graded stone aggregate 40 mm nominal size) and
inside plastering with cement mortor 1:3 (1 cement : 3 coarse
sand) 12 mm thick finished with a floating coat of neat cement
complete as per standard design. : With common burnt clay
F.P.S (non modular) bricks of class designation 7.5
176 16.23 Supplying and fixing of following thickness duly laminated
aluminum foil of mat finish closed cell Nitrile rubber (class “O”)
insulation on existing duct after applying two coats of cold setting
adhesive (CPRX compound). The joints shall sealed with 50 mm
wide and 3 mm thick self adhesive nitrile rubber tape insulation
complete as per specifications and as required.
ELECT. 19 mm thick
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
ELECT. 25 mm thick
177 ELECT. Providing, laying and fixing following dia GI pipes (medium
DSR 2014 class) conferming to IS 1239 with GI fittings including cutting
/ 14.13.3 hole chase painted with primer, two coats of enamel paints etc
178 16.7.1 BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile
Rubber Seal & O- Ring PN 16 pressure rating for chilled
water/hot eater circulation as specified - -
ELECT. 65 nominal bore
ELECT. 80 nominal bore
179 M.R. Providing and fixing brass ball valve with SS 304 Stem and ball,
teflon seat complete (PN-16). - -
M.R. 15 mm dia nominal bore Each 333.08 2.00 666.15
M.R. 20 mm dia nominal bore Each 464.76 11.00 5,112.32
M.R. 25 mm dia nominal bore Each 725.54 10.00 7,255.36
180 Providing, fixing, testing and commissioning of motorised
butterfly valve of following dia for filling of overhead water tank
complete with high and low level control switches to control
tanks. The level controllers shall be installed in iverhead tanks.
The level switch will close the valve when water level is high in
overhead tank and open the valve when overhead water tank
level is low. The system should be complete in all respects with
accessories 220 V AC / 2 V DC, IP67 electrical water level
control unit, copper control wiring in whether proof casing etc.
M.R. 50 mm dia NB Float Valve Set 37,234.72 1.00 37,234.72
181 M.R. Providing & fixing schedule puddle flanges made of heavy class
M.S. pipe minimum 700 mm long, both side threading upto 50
mm dia pipe and one side threaded and other side flanged for
63dia and above sizes with epoxy coating. M.S. Plate 230 x 230
x 6 mm shall be used for pipe size upto 50 mm dia, 300 x 300 x
6 mm M.S. plate shall be used upto 80 mm dia pipe, 400 x 400 x
6 mm M.S. plate shall be used upto 250 mm dia pipe, 450 x 450
x 6 mm M.S. plate shall be used upto 350 mm dia pipe. (Length
of pipe shall be increase in some cases).
25 mm dia nominal bore Each 427.75 8.00 3,421.98
50 mm dia nominal bore Each 578.47 2.00 1,156.95
65 mm dia nominal bore Each 667.23 2.00 1,334.47
80 mm dia nominal bore Each 746.23 2.00 1,492.45
100 mm dia nominal bore Each 959.55 6.00 5,757.29
150 mm dia nominal bore Each 1,269.52 2.00 2,539.05
ELEC M.R. Solar Water Heaters - -
182 Providing, fixing, testing and commissioning of solar water
heater panels with automatic thermostatic control, pressure
release valve, storage tank complete including cutting and
making good the floors / walls wherever required. - -
Capacity : 600 LPD with SS storage tank with re-circulating
pumps of 600 litres with proper insulation, electrical element and
control panel including all interconnecting SS 304 piping and
INTERNAL & EXTERNAL ELECTRICAL WORKS - -
SUBHEAD A : INTERNAL ELECTRICAL INSTALLATIONS
( SCHEDULE ITEMS) - -
Wiring in PVC Conduit - -
Point wiring in pvc conduit, with modular type switch. - -
183 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point
with 1.5 sq.mm FRLS PVC insulated copper conductor single
core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing
the point with 1.5 sq.mm. FRLS PVC insulated copper conductor
single core cable etc as required. - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
1.10.3 Balance work (Testing and commission or any other work
required of already installed item for final handover to NBCC /
Client at their satisfaction) Points 359.00 410.00 147,190.00
184 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, 2 way modular switch,
modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS PVC insulated copper conductor single core cable
etc as required.
TV & TELEPHONE - -
185 1.18 Supplying and drawing following pair 0.5 sq mm FRLS PVC
insulated annealed copper conductor, unarmored telephone
cable in the existing surface/ recessed steel/ PVC conduit as
required. - -
1.18.3 Balance work (Testing and commission or any other work
required of already installed item for final handover to NBCC /
Client at their satisfaction) Metre 8.10 1,465.00 810.00
186 1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm
solid copper conductor PE insulated, shielded with fine tinned
copper braid and protected with PVC sheath in the existing
surface/ recessed steel/ PVC conduit as required. Metre 28.00 - -
1.19 Balance work (Testing and commission or any other work
required of already installed item for final handover to NBCC /
Client at their satisfaction) Metre 8.40 297.00 2,494.80
187 1.24 Supplying and fixing following modular switch/ socket on the
existing modular plate & switch box including connections but
excluding modular plate etc. as required. quivalent) - -
1.24.6 Telephone socket outlet Each 95.00 66.00 6,270.00
1.24.7 TV antenna socket outlet Each 94.00 5.00 470.00
Power plug wiring in pvc conduit - -
188 1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
recessed medium class PVC conduit alongwith 1 No 4 sq. mm
FR PVC insulated copper conductor single core cable for loop
earthing as required (cable having Low Leakage Current -
0.01mA, ROHS Compliant).
1.12 Balance work (Testing commissiong and mending good to
damages or any other works required in proper satisfactory
working condition as per EIC. for final handover to NBCC /
Client at their satisfaction) Meter 16.20 2,919.40 47,294.28
189 1.13 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm
FRLS PVC insulated copper conductor single core cable for loop
earthing as required. (cable having Low Leakage Current -
0.01mA, ROHS Compliant) Meter 275.00 30.00 8,250.00
190 1.14.4 Wiring for 20 Amp power plug point with 2 x 6.0 sq.mm FRLS
PVC insulated stranded copper conductor wire in surface /
recessed PVC conduit, along with 1 No. 6.0 sq.mm FRLS PVC
insulated copper conductor single core cable for loop earthing as
required.(cable having Low Leakage Current - 0.01mA, ROHS
Compliant) Meter 221.00 60.00 13,260.00
Circuit/Submain wiring in pvc conduit - -
191 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FRLS PVC insulated copper conductor, single
core cable in surface/ recessed medium class PVC conduit as
required. (All wires have Low Leakage Current - 0.01mA, ROHS
Compliant, Anti Termite and Anti Rodent.)
1.14.1 Balance work (Proper testing ,commissioning and handingover
or any other works required in proper staisfatory working
condition of EIC for final handover to NBCC / Client at their
satisfaction) Metre 31.80 41.00 1,303.80
1.14.2 Balance work (Proper testing ,commissioning and handingover
or any other works required in proper staisfatory working
condition of EIC for final handover to NBCC / Client at their
satisfaction) Metre 39.30 4,135.00 162,505.50
1.14.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire Metre 389.00 30.00 11,670.00
1.14.10 Balance work (Proper testing ,commissioning and handingover
or any other works required in proper staisfatory working
condition of EIC for final handover to NBCC / Client at their
satisfaction) Metre 179.10 129.80 23,247.18
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
#REF! Balance work (Proper testing ,commissioning and handingover
or any other works required in proper staisfatory working
condition of EIC for final handover to NBCC / Client at their
satisfaction) Metre 264.90 119.30 31,602.57
192 1.20 Supplying and fixing of following sizes of steel conduit along with
accessories in surface/recess including painting in case of
surface conduit, or cutting the wall and making good the same in
case of recessed conduit as required. - -
193 1.21 Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required. - -
#REF! Balance work (Proper testing ,commissioning and handingover
or any other works required in proper staisfatory working
condition of EIC for final handover to NBCC / Client at their
satisfaction) Metre 15.90 714.40 11,358.96
1.21.2 Work already executed by the previous agency
1.21.2 Balance work (Proper testing ,commissioning and handingover
or any other works required in proper staisfatory working
condition of EIC for final handover to NBCC / Client at their
satisfaction) Metre 19.50 1,304.70 25,441.65
Switch & Socket - -
194 1.24.1 Supply and fixing 6 Amps single pole modular type switch one
way on the existing modular plate & sheet steel box including
connections etc. as required. Nos. 81.00 - -
195 1.24.8 Supply and fixing bell push modular type switch . Socket on the
existing modular plate & sheet steel box including connections
etc. as required. Nos. 111.00 - -
196 1.31 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and
fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required as per
havells/Schneider. (For light plugs to be used in non residential
buildings & Switch have 2 Lakh operations guaranteed).
197 1.32 Supplying and Fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and
fixing 6 pin 16 A & 16 A modular socket outlet and 16 A modular
switch, connection etc as required as per
havells/Schneider/crabtree. (Switch have 2 Lakh operations
198 2.18 Supplying and fixing 20 amps, 240 volts, SPN industrial type,
socket outlet, with 2 pole and earth, metal enclosed plug top
alongwith 20 amps “C” curve, SP, MCB, in sheet steel
enclosure, on surface or in recess, with chained metal cover for
the socket out let and complete with connections, testing and
commissioning etc. as required as per havells/ Schneider/
crabtree. Each 954.00 3.00 2,862.00
199 2.20 Supplying and fixing 30 amps, 415 volts, TPN industrial type,
socket outlet, with 4 pole and earth, metal enclosed plug top
alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure,
on surface or in recess, with chained metal cover for the socket
out let and complete with connections, testing and
commissioning etc. as required. as per
havells/Schneider/crabtree. 2,473.00 1.00 2,473.00
Light Fixtures & Fans - -
S/F modular type electronic fan regulator: - -
200 1.25 Supplying and fixing stepped type electronic fan regulator on the
existing modular plate switch box including connections but
excluding modular plate etc. as required. Nos. 284.00 175.00 49,700.00
ITC Ceiling fan with cover on fan box: - -
201 1.45 Installation, testing and commissioning of ceiling fan, including
wiring the down rods of standard length (upto 30 cm) with 1.5 sq.
mm FRLS PVC insulated, copper conductor, single core cable,
including providing and fixing phenolic laminated sheet cover on
the fan box etc. as required.
ITC exhaust fan upto 450 mm sweep: - -
202 1.50 Installation of exhaust fan upto 450 mm sweep in the existing
opening, including making the hole to suit the size of the above
fan, making good the damage, connection, testing,
commissioning etc. as required. Nos. 204.00 33.00 6,732.00
Fixing louvers / shutters for exhaust fan: - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
203 1.51 Extra for fixing the louvers/ shutters complete with frame for
exhaust fan of all sizes. Nos. 90.00 33.00 2,970.00
Extra down GI pipe 15mm dia: - -
204 1.47 Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15
mm dia, heavy gauge including painting etc. as required. (Note:
More than 5 cm length shall be rounded to the nearest 10 cm
and 5 cm or less shall be ignored). Nos. 23.00 30.00 690.00
Main & Sub-Distribution Boards - -
205 2.7 Supplying and fixing following way, single pole and neutral,
prewired, sheet steel, MCB distribution board, 240 volts, on
surface/ recess, complete with loose wire box, terminal blocks,
duly prewired with suitable size FRLS PVC insulatoed copper
conductor up to terminal blocks, tinned copper busbar, neutral
link, earth bar, din bar, detachable gland plate, interconnections,
phosphatized and powder painted including earthing etc. as
required (But without MCB/ RCCB/ isolator) (make-havells/
siemens/ crabtree) (DB have Removable Main busbar/ Pan
Assembly in SPN/TPN Distribution Board to aid installation,
Main earth stud allows earth to be terminated inside or outside
2.7.4 2 + 4 way / 6 way, Double door Each 2,508.00 - -
2.7.4 Balance work (Testing commissiong and mending good to
damages or any other works as required in proper satisfactory
working condition as per Standard . for final handover to NBCC
/ Client at their satisfaction.) Each 752.40 3.00 2,257.20
2.7.6 Balance work (Testing commissiong and mending good to
damages or any other works as required in proper satisfactory
working condition as per Standard . for final handover to NBCC
/ Client at their satisfaction.) Each 1,083.90 3.00 3,251.70
206 2.8 Supplying and fixing following way prewired TP&N MCB
distribution board of steel sheet for 415 volts on surface/ recess
complete with loose wire box, terminal connectors for all
incoming and outgoing circuits, duly prewired with suitable size
FR PVC insulated copper conductor up to terminal blocks,
tinned copper bus bar, neutral link, earth bar, din bar, detachable
gland plate, interconnections, powder painted including earthing
etc. as required.(But without MCB/ RCCB/ Isolator) (make-
havells/ siemens/ crabtree) (DB have Removable Main busbar/
Pan Assembly in SPN/TPN Distribution Board to aid installation,
Main earth stud allows earth to be terminated inside or outside
2.8.6 Balance work (Testing commissiong and mending good to
damages or any other works as required in proper satisfactory
working condition as per Standard . for final handover to NBCC
/ Client at their satisfaction.) No. 2,848.80 22.00 62,673.60
2.8.7 Balance work (Testing commissiong and mending good to
damages or any other works as required in proper satisfactory
working condition as per Standard . for final handover to NBCC
/ Client at their satisfaction.) No. 3,121.50 1.00 3,121.50
2.8.8 Balance work (Testing commissiong and mending good to
damages or any other works as required in proper satisfactory
working condition as per Standard . for final handover to NBCC
/ Client at their satisfaction.) No. 3,834.60 1.00 3,834.60
207 2.14 Supplying and fixing following rating, double pole, (single phase
and neutral), 240 volts, residual current circuit breaker (RCCB),
having a sensitivity current upto 300 milliamperes in the existing
MCB DB complete with connections, testing and commissioning
etc. as required. - -
208 2.15 Supplying and fixing following rating, four pole, (three phase and
neutral), 415 volts, residual current circuit breaker (RCCB),
having a sensitivity current upto 300 milliamperes in the existing
MCB DB complete with connections, testing and commissioning
etc. as required. - -
209 2.13 Supplying and fixing following rating, four pole, 415 volts, isolator
in the existing MCB DB complete with connections, testing and
commissioning etc. as required. - -
210 2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,
"C" curve, miniature circuit breaker suitable for inductive load of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
211 2.11 Supplying and fixing single pole blanking plate in the existing
MCB DB complete etc. as required. each 7.00 50.00 350.00
Cable, Cable Tray & Cable management - -
212 9.1 Supplying and making end termination with brass compression
gland and aluminum lugs for following size of PVC insulated and
PVC sheathed/ XLPE aluminum conductor cable of 1.1 KV
grade as required. - -
213 4.1 Supplying and installing Following size of perforated pre-painted
M.S. cable trays with all accessories perforation not more than
17.5%, in convenient sections, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts
& nuts, painting suspenders etc as required. - -
4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness #REF! 520.00 - -
4.1.8 300 mm width X 62.5 mm depth X 2.0 mm thickness Metre 878.00 90.00 79,020.00
4.1.14 600 mm width X 75 mm depth X 2.0 mm thickness Metre 1,493.00 45.00 67,185.00
214 1.1.13 900 mm width X 75 mm depth X 2.0 mm thickness Metre 2,038.00 - -
215 10.4 Supplying and making INDOOR cable end termination with heat
shrinkable jointing kit complete with all asccessories including
lugs suitable for following size of 3 core, XLPE aluminium
conductor cable of 11 KV grade as required: - -
Earthing & Lightning Conductor - -
216 5.10 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia
G.I. pipe from earth electrode including connection with brass
nut, bolt, spring, washer excavation and re-filling etc. as
217 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.
pipe FRLS from earth electrode including
connection/terminating with G.I. nut, bolt, spring, washer
excavation and re-filling etc. as required. RM 421.00 300.00 126,300.00
218 5.15 Providing and fixing 25 x 5 mm GI strip on surface or in recess
for connections etc. complete as required . RM 142.00 200.00 28,400.00
219 5.14 Providing and fixing 25 x 5 mm Copper strip on surface or in
recess for connections etc. complete.. RM 856.00 100.00 85,600.00
220 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below
ground level for conductor earth electrode, including connection/
termination with GI thimble etc. as required. RM 27.00 410.00 11,070.00
INTERNAL ELECTRICAL INSTALLATIONS (NON
SCHEDULED ITEMS) - -
Wiring in PVC Conduit - -
221 MR wiring for SP MCB controlled light points/ fan point with 2 x 1.5
sq.mm FR PVC insulated stranded copper conductor wire in
surface / recessed pvc conduit, along with 1 No. 1.5 sq.mm FR
PVC insulated copper conductor single core cable single core
cable having Low Leakage Current - 0.01mA, ROHS Compliant,
Anti Termite and Anti Rodent for loop earthing as required. (mcb
cost are not include in that item)
222 MR Wiring for secondary/loop light point controlled by switch wihich
having garanted 2 lakh operations with 2 x 1.5 sq.mm FR PVC
insulated stranded copper conductor wire in surface / recessed
pvc conduit, along with 1.5 sq.mm FR PVC insulated copper
conductor single core cable single core cable having Low
Leakage Current - 0.01mA, ROHS Compliant, Anti Termite and
Anti Rodent for loop earthing as required.
Points 482.74 - -
Work already executed by the previous agency Points 96.55 - -
Balance work (Testing commissiong and mending good to
damages or any other works as required in proper satisfactory
working condition as per Standard.) Points 193.10 - -
Balance work (Testing commissiong and mending good to
damages or any other works as required in proper satisfactory
working condition as per Standard. for final handover to NBCC
/ Client at their satisfaction) Points 193.10 514.00 99,252.12
Switch & Socket - -
223 MR Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and
fixing 2 nos 3 pin 6 A modular socket outlet with shutter & 1
nos 16 A modular switch, connection etc as required Switch
have 2 Lakh operations guaranteed as per
havells/Schneider/crabtree. Each 441.36 10.00 4,413.63
Light Fixtures & Fans - -
224 MR Supply, installation, testing and commissioning of 36W LED
600x600 mm fixture with complete as required and as per Bajaj
Cat No BZRSQL 36W GIII WH or equivalent. Each 5,732.85 180.00 1,031,913.25
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
225 MR Supply, installation, testing and commissioning of 20-28W
recessed LED Linear light fixture suitable for Techzone false
ceiling as per Bajaj Cat No BPTXn 20W LED 4F NW or
equivalent. Each 5,939.75 - -
226 MR Supply, installation, testing and commissioning of 12W LED
downlight fixture complete as required and as per Bajaj cat no
BGSLO Sleek 12W WH RD or equivalent. Each 1,594.80 195.00 310,986.32
227 MR Supply, installation, testing & commissioning of surface mounted
type 18-20 W LED light fixture 1200mm long with electronic
driver, pre-wired upto main connections complete as required as
per bajaj cat no BCLSB 18 NW or equivalent. Each 1,025.82 48.00 49,239.35
Balance work (Testing commissiong and mending good to
damages or any other works as required in proper satisfactory
working condition as per Standard. for final handover to NBCC
/ Client at their satisfaction) Each 153.87 3.00 461.62
228 MR Supply, installation, testing & commissioning of surface mounted
type light fixture suitable for 2 x 18 W LED lamp with electronic
driver and mounting arengment (in contractor scope), pre-wired
upto main connections complete as required as per Bajaj cat no
BLRB-DB 218+2xBLRB 18W CW or equivalent.
229 MR Supply, installation, testing & commissioning of above mirror
mounted type 5 W LED light fixture with electronic driver, pre-
wired upto main connections complete as required as per Bjaj
Cat No BCLSB 05 NW or equivalent. Each 612.01 10.00 6,120.15
230 MR Supply, installation, testing and commissioning of surface 12W
LED downlight fixture complete as required and as per Bajaj cat
no BGSLO Sleek Surface 12 WH RD or equivalent. Each 1,775.84 114.00 202,445.76
231 MR Supply, installation, testing and commissioning of Spot Light
28W LED fixture complete as required and as per Bajaj cat no
BRTL 28W LED or equivalent. Each 7,801.88 - -
232 MR Supply, installation, testing and commissioning of LED system
consisting of 18 LED. Luminaire luminous flux 3800 lm,
connected load 43 W, luminous efficiency of luminaire 88 lm/W.
Light colour neutral white, colour temperature 4000 K, colour
rendering index Ra > 80. service life: L80 (tq 35 °C) = 50,000 h,
Spotlight body of die-cast aluminium, Colour of luminaire body
anthracite, similar to DB 703 with metal effect, highly weather
resistant, powdercoated. Further colour variants possible from
RAL or DB colour codes. With pan-and-tilt, Swivel range 195°,
Rotation range 360°. With flat cover, extra clear, 5 mm, Optical
system consisting of one PMMA lens system for each LED. With
rotationally symmetrical medium-wide light distribution.
Maximum light intensity in beam angle 2 x 11°. complete as
required and as per Trilux Faciella 20 RM1L or equivalent. Each 64,119.12 12.00 769,429.38
233 MR Supply, installation, testing & commissioning of Decorative wall
light with min 18W LED lamp with made of Stainless steel and
Glass. Make : Bajaj/Philips Wall Light or equivalent
234 MR Supply, installation, testing & commissioning of LED Bulkhead
luminaire as per Bajaj Cat no BIBWP 10W LED or equivalent. 1,853.43 - -
Balance work (Testing commissiong and mending good to
damages in proper satisfactory working condition as per
Standard. for final handover to NBCC / Client at their
satisfaction) Each 278.01 21.00 5,838.30
235 MR Supply, installation, testing & commissioning of Aviation
obstructing light fixture complete as required with accessories
and as per as per bajaj cat no BGAV 302 LED or equivalent. Each 5,008.69 - -
236 MR Supply, installation, testing & commissioning of 45W LED post
top light fixture with suitable arm and all accessiories as per
Bajaj cat no BRIL 45W LED NW or equivalent. 16,388.33 - -
Work already executed by the previous agency Each 13,930.08 - -
Balance work (Proper testing ,commissioning or any other
works as required and handing over in proper staisfatory working
condition of EIC/ client) Each 2,458.25 - -
237 MR Supply, installation, testing & commissioning of up & Down LED
light fixture with all accessiories as per Bajaj cat no BLWUD 70
MH T WOB or equivalent. Each 14,960.70 9.00 134,646.32
238 MR Supply of following size special design energy saving ceiling
fans similar to Havells Energy Saver with low power
consumtion as specified below aluminum motor covers of larger
diameters complete with copper winding, double ball bearings,
Aluminium blades, down rod, shackle insulator, canopy but
without regulator etc complete as required . - -
MR 1400 mm sweep Nos. 2,387.99 - -
239 MR Supply Exhaust fan 300 mm dia 1400rpm complete with louvers,
copper winding and provision of cable from ceiling
rose/connector to fan all as specified as per Havells Power
240 MR Supply Exhaust fan 450 mm dia 1400rpm complete with louvers,
copper winding and provision of cable from ceiling
rose/connector to fan all as specified as per Havells Power
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
Cable, Cable Tray & Cable management - -
241 Supply & Laying of following sizes of Stranded
Aluminium/copper Conductor FRLS XLPE insulated PVC
sheathed heavy duty power armoured cable A2XFY confirming
to IS-7908- Part 1 1100 volt grade ISI marked etc & cable
manufecture shall have NABL Accredited Lab and complete as
required. - -
MR 4 x 16 Sq mm Aluminium Metre 254.84 200.00 50,968.24
MR 3.5 x 25 Sq mm Aluminium Metre 314.59 200.00 62,917.63
MR 3.5 x 35 Sq mm Aluminium Metre 377.96 100.00 37,795.85
MR 3.5 x 95 Sq mm Aluminium Metre 771.72 200.00 154,343.75
MR 3.5 x 150 Sq mm Aluminium Metre 1,122.03 50.00 56,101.64
MR 3.5 x 185 Sq mm Aluminium Metre 1,376.39 25.00 34,409.80
MR 3.5 x 240 Sq mm Aluminium Metre 1,728.51 - -
MR 3.5 x 300 Sq mm Aluminium Metre 2,069.77 260.00 538,141.15
N.S. 3.5 x 400 Sq mm Aluminium Metre 2,668.11 - -
242 MR Supplying & laying of the following size of HT cable of 11KV(E)
XLPE & cable manufecture shall have NABL Accredited Lab as
per IS- 7098, Part-II of following size in the existing DUCT/RCC/
HUME/ METAL PIPE/CABLE TRAY as required.
Earthing & Lightning Conductor - -
243 MR Supply and Installation of basic earthing material to construct
unit maintenance free chemical earthing. Earthing should be
Copper bonded Rod of 3 Mtr long, 17.2 mm dia with copper
bonding thickness of minium 250 microns. The rod should be
duly certified and tested by CPRI & UL. Earth Rod shall have
pass the test required of BS 7430/ANSI/UL 467 and confirm to
the adhesion of the copper coating to the steel core and Body
system of earthing shall be TNS. To ensure the moisture content
and electrical conductivity, min 50 Kgs of Reflow - resistance
lowering grounding minerals shall be used as a backfill
compound. The compound shall be of low resistance & high
conductivity in nature with carbon as a major content which
dramatically lowers ground resistance system in difficult soil
situations. Ground Enhancement material shall be as per IEEE -
80 Clause 14.5d with a resistivity of less than 0.12 Ohm-Meter.
Balance installation testing and commissioning
Testing commissiong and mending good to damages in proper
satisfactory working condition of already installed earthings as
per Standard. Set 1,883.64 28.00 52,741.92
244 MR Supply & Installation of FRP earth pit chamber (300mm x
300mm) shall be included in the scope of work. Installation
would be as per supplier. Set 861.95 30.00 25,858.51
245 MR The specification covers design & supply of Advance Lightning
Protection System ION Streamer, the system should be so
designed to be capable of protecting against direct lightning
point as well as conducting/diverting it to Earth completely after
tracing the lightning in advance. The air terminal should be of 8
inches length with 3 inches dia. and verified and tested from
CPRI at 40 kA current discharge. Supplier should be A Class
Contractor; the product should be tested from
International/National Laboratory. - -
System Components: The system should consist of the following
components for performing the desired task as above in the
i) Early Streamer Emission Air Terminal with following
features: Set 68,449.97 - -
a) Stainless Steel central capture head of 316 L - -
b) Other avoiding bolting and water infiltration that can cause
premature corrosion - -
c) Ion Generator Device non electronics type for early streamer
d) Control over release of ions positive or negative generation of
streamer through Corona Effect. - -
e) Follow the concept of NFC 17-102 - -
f) Area coverage in radius 32 mtrs. - -
g) System should not depend on electrical energy - -
h) ESE air terminal should be mounted on round insulator having
80 mm dia. and length of 145 mm for termination of down
conductor. This should be mounted between air terminal and
i) Dimension and weight to be furnished - -
ii) Mast and Insulator with following features: Set 5,422.50 - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
a) Supply of mast and insulator and it shall be mounted at least 2
Mtr clear to the highest point on roof top by support. The mast
should be 40 mm dia GI Pipe duly galvanized with minimum 85
micron zinc coating with stand of 100 X 100 X 7 mm. - -
b) Insulator – High Grade DMC based insulator for giving
appropriate path to fault current via down conductor. - -
iii) Lightning Strike Counter with following features: Set 7,801.88 - -
a) Number of counts- 6 digits - -
b) Current sensitivity- 1 kA to 200 kA - -
c) Inductance Shunt- 0.5 micro Henry - -
d) Enclosure- IP 67 - -
e) No external power source is required - -
iv) Down Conductor with following features: Mtr 536.21 - -
a) Supply of JMV Copper 70 sq mm Teflon insulated cable for high
lightning discharge current as a down conductor. Cable should
be composed of copper core covered by concentric silver plating
on it. The tensile strength should be between 220-270 (N/sq
mm), resistance (IACS) 100%, conductivity 58.5 (S*m/sq mm)
and able to withstand temperature of 350 ° C. The conductor
should have high conductivity, thermal resistance and bright and
shiny surface. - -
B : EXTERNAL ELECTRICAL INSTALLATIONS ( SCHEDULE
Misc. safety equipment - -
246 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150
mm, made of mild steel, at least 2 mm thick, and vitreous
enameled white on both sides, and with inscription in signal red
colour on front side as required. Each 141.00 10.00 1,410.00
247 2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200
mm, made of mild steel, at least 2 mm thick, and vitreous
enameled white on both sides, and with inscription in signal red
colour on front side as required. Each 155.00 8.00 1,240.00
248 MR PACKAGE SUBSTATION - -
Supply, installation, testing & commissioning of 11kV compact
secondary substation outdoor type designed for natural cooling
(K-10 class), having type tested equipments comprising of dry
type distribution transformer and SF-6 insulated compact
switchgear enclosed in robotically sealed stainless steel tank,
low-voltage switchboard, interconnection between HT
switchgear and transformer using 3Rx1Cx95sqmm XLPE cables
and transformer to LT-switchgear using aluminium busbars,
factory built ready for connection type, internal GI earthing
provided complete with other associated equipments etc.
complete as required conforming to IEC 62271-202 and relevant
IS specifications, as regards to design, manufacturing, type-
testing, routine-testing and general operator safety precautions.
The enclosure shall have modular construction using atleast
2mm thick GI. Sheet and shall be powder-coated from exterior.
Complete compact substation including RMU, Transformer & LV
side shall be made/supply of same OEM.The Transformer
compartment will have IP-23 ingress protection, naturally
ventillated, CFL illuminated and suitably interlocked to trip on
door-opening: - -
MR HT Switchgear - -
HT SWITCHGEAR shall comprise of 03-Way RMU having
02nos. Load Break Switch and 01no. Fixed-Type VCB feeding
respectively to X'mer, all enclosed in common tank, made from
Stainless Steel sheets, and filled with SF6 gas acting as an
excellent insulating medium. The tank design shall meet IP-67
criteria with SF6 gas leakage rate less than 0.1% per-annum,
and shall be Arc-Proof design with Internal Arc criteria of 20kA/1-
sec, which shall be proven via suitable type-test report for similar
design showing the RMU placed inside the CSS. Make :
Siemens, Schneider, Abb
The complete RMU shall be a front-panel design comprising of
following accessories:
The breakers shall have stored energy spring-charging
mechanism with manual spring charging and distinct
mechanical/electrical operated push-buttons for breaker
ON/OFF arrangement. It will be provided with integrated Self-
Powered 3OC+1EF relay with LCD display, capable of tripping
on Low and High set for Over current and Earth Fault. Relay
should have facility to display the maximum loaded phase
current and record minimum 5 fault records with time stamping.
Relay shall be operated via Resin cast RingCore Protection CTs
of suitable ratio and burden, pre-installed in the respective cable-
The Ring Switches and Tee-Off Circuit Breaker are provided
with Integrated Earthing Switches with Making Capacity. - -
Earth interlocked, arc proof Cable boxes having bushing
arrangement for cable-termination along with capacitive voltage
indicators - -
Removable/Replacable SF6 Gas pressure indicator with gas-
recharging facility. - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
Shunt trip coil rated for 230V AC. - -
HT CT/PT metering unit comprising of associated HT CT having
ratio 15/1, 3VA, Cl.1.0 and associated fuse-protected PT having
ratio 11kV/110V, 25VA, Cl.1.0 with suitable LEDs for R-Y-B
Phase indication, thermostat based space heater and
Multifunction meter for measuring various parameters such as
Amp, kV, kVA, kW, pF, Hz etc. - -
Transformer - -
TRANSFORMER shall comprise of 500KVA 11KV/433V DYn11
Copper Wounded Cast Resin Dry Type Transformer with Off
load tap links of +5% to -5% @2.5% with WTI scanner.
Transformer shall be double wound ,core type with low loss, non
ageing ,high permeability PRIME GRADE , CRGO with M4
Grade or Better, perfectly insulated and clamped to minimize
noise and vibrations. Standard : IEC 60076 ,Class of
Insulation:minimum F, Temperature rise 90 deg.C. Losses (IS
Tol.) as per data sheet encl. and Impedance of 5% (IS Tol.).
Transformer shall be of same make as OEM of CSS..
Oil Temperature Indicator – 1 No - -
MR LT Switchgear - -
LT PANEL shall comprise of IP4X protected, powder coated
panel installed inside IP54 protected enclosure requiring no
external cooling arrangement, using Aluminium busbars rated
for 1000Amp, TPN design, suitably labelled for phase
identification purpose, and having voltmeter+R-Y-B LED
indications to notify presence and quality of voltage available on
busbar. The LT Panel shall comprise of following configuration:
1 No. 4-pole 800A, 50kA, ACB with microprocessor based over
current, short circuit & earth fault release with all accessories &
IP-54 protection. Trip release with LCD display shall have
thermal memory, ZSI ,last ten trip history and capable of current
& voltage metering. Distinct fault indication on release of OL,SC
& EF. Schneider Electric , Siemens , ABB
PSS Complete as above and as required EACH 2,232,808.91 - -
ELECTRICAL LV PANELS & ACCESSORIES - -
249 MR Supply, installation, testing and commissioning of front operated,
front / back access, cubicle type, indoor duty, floor / wall / recess
/ surface mounted (as specified), totally enclosed dust and
vermin proof switchboards / panels with minimum Ingress
protection classification of IP 44, fabricated from 2 mm thick
CRCA sheets with dip coat priming and epoxy powder coated
finish. The panel must be suitable for 415 volts 3 phase, 4 wire,
50 Hz, system , must be able to withstand symmetrical fault level
of 50 KA for 1 sec at 415 V and must include all
interconnections, earthing and bonding requirements etc. The
panel must conform to standards, as required and as given
The Switchboard shall be provided with detachable gland plates
for entry of cables from the top / bottom as required. - -
All live accessible parts shall be shrouded and all equipment
shall be finger touch proof. The busbars shall be insulated with
heat shrinkable sleeves. SMC / DMC shrouds and busbar
supports suitably spaced shall be used. Hinged doors with
padlocking facility shall be provided on all outgoing feeders with
switch handles lockable in OFF position.
The panel shall have aluminium busbars with bar type feeder
connections, spacers etc. with full sized neutral.
Earthing all components, frame etc. to a common internal earth
bar of size 25 x 6 mm Cu.
Panel / Switchboard board design shall be compact and
components / accessories of compact sizes shall be used to
economise the room space available. Employer reserve the right
to seek compact items inplace of larger ones. - -
MAIN LT PANEL - -
PSS & DG Set Incomer (2 No.) and shall be equipped with: - -
2 nos 800 A 4 Pole EDO type electrically operated air circuit
breaker with 230V AC spring charging motor; micro processor
based O/C, S/C & E/F release with communication through
RS485/RS232 Port; 6 NO + 6 NC auxiliary contacts for fire alarm
(switch) and each contains following.
1 No. 24V DC shunt release. - -
1 No. 230V AC closing coil. - -
1 No. 415V AC under voltage release. - -
1 No. Analog Ammeter 0-1250 A with ASS. - -
1 No. Analog Voltmeter 0-500 V with VSS. - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
3 Nos. CTs 1250/5A Class 1.0 for metering. - -
1 No. CT 1250 / 5A for APFC relay. - -
1 No. MFM - -
1 No. TNC Switch - -
Trip Circuit Supervision & Master Trip Lockout Relay - -
1 nos Tvss 100KA (SPD) of each incomer. - -
Over voltage and under voltage relay with a tripping mechanism
for persisted voltage of 110 % or 90 % of rated voltage shall be
provided & No voltage relay shall be provided for giving signal
to DG incomer/PLC Panel. - -
Indications with 2 A SP MCB back up: - -
R,Y,B Phase - -
Breaker ON, OFF, TRIP & Trip Circuit Healthy - -
Spring Charged. - -
Bus Coupler - -
1 nos 800 A 4 Pole EDO type electrically operated air circuit
breaker with 230V AC spring charging motor; micro processor
based O/C, S/C & E/F release with communication through
RS485/RS232 Port; 6 NO + 6 NC auxiliary contacts (switch) and
all accessiores. - -
Interlocking - -
Electrical & Mechanical Interlocking with 1 nos transformer
incoming & 1 nos DG set incoming with 1 no bus coupler in such
a way that at any one time two supplies should not get mixed up.
Electrolytic high conductivity 3-phase 4 wire aluminium
conductor bus-bars rated 1000 Amps, suitable to withstand
symetrical fault level of 50 KA for 1 second at 415 volts and with
necessary heat shrinkable sleeving.
Outgoing: - -
3 Nos. 400/630 A 4P MCCB 50 KA having microprocessor
based Trip Unit with protection against Overload (with base
setting and fine adjustment), Short Circuit and Earth Fault (all
with adjustable time delays) and instantaneous protection,
NO/NC contacts for operation, LED Indication for Phase, CB
'ON', 'OFF', 'TRIP' complete as required. - -
7 Nos. 250/200 A 4P MCCB 50 KA having microprocessor
based Trip Unit with protection against Overload (with base
setting and fine adjustment), Short Circuit and Earth Fault (all
with adjustable time delays) and instantaneous protection,
NO/NC contacts for operation, LED Indication for Phase, CB
'ON', 'OFF', 'TRIP' complete as required. - -
3 Nos. 125 A 4P MCCB 25 KA having Thermal Magnetic Trip
Unit with protection against Overload and Short Circuit, LED
Indication for Phase, CB 'ON', 'OFF', 'TRIP' complete as
required. - -
4 Nos. 100 A 4P MCCB 25 KA having Thermal Magnetic Trip
Unit with protection against Overload and Short Circuit, LED
Indication for Phase, CB 'ON', 'OFF', 'TRIP' complete as
required. - -
3 No. 63 A 4P MCCB 25 KA having Thermal Magnetic Trip Unit
with protection against Overload and Short Circuit, LED
Indication for Phase, CB 'ON', 'OFF', 'TRIP' complete as
required. - -
Main LT Panel complete as above and required: Each 1,301,747.47 - -
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) Each 195,262.12 1.00 195,262.12
CAPACITOR PANEL - -
250 MR Design, manufacturing, testing at works and SITC of cubical
type CRCA sheet steel free standing indoor type 125 KVAR
Capacitor Bank Panel with shunt capacitor with harmonic filter
and discharge resistor suitable for 400/440 V, 3 phase 50 Hz
supply system and having aluminium bus bars and accessories
with their connections. The panel shall be well ventilated, dust
and vermin proof extensible on both sides etc. complete as
required. - -
1 No. 400 A TP MCCB 35 KA with microprocessor based
release for O/C & SC protection, 3 Nos. CT 630/5 A class 1.0, 0-
630 A Ammeter with built in ASS, TNC Switch, Indication for
Phase, CB 'ON', 'OFF', 'TRIP' complete as required.
400 Amps 3-phase 4 wire electrolytic aluminium conductor bus
bar 35 KA rms - -
5 nos. 80 A TP MCCB with thermal magnetic release 35 KA
breaking capacity - -
5 nos. contactor 70 A capacitor duty with 230 V AC coil - -
5-8 sets of Red-Green (ON-OFF) self illuminated push buttons
for manual operation of capacitors - -
5 nos. 25 KVAR MPP capacitor bank with 7 % D-tuned reactor
filter and discharge resistor - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
1 no. 12-step APFC Relay with binary operation having facility to
change the sequence of switching 'ON' the capacitor banks as
required so that the end unit is not kept idle for long. - -
ON/OFF indication lamp with 2 A SP MCB backup in each
capacitor unit - -
OFF delay timer for manual mode Aux. Contactor as required
1 no. selector switch for Auto/Manual/Off - -
Capacitor Panel complete as above and required: Each 250,004.38 - -
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) Each 37,500.66 1.00 37,500.66
GROUND, 1st, 2nd, 3rd, 4th & 5th FLOOR PANEL - -
251 MR 1 No. 200 A, 415V, 25 kA, 4P MCCB having (1) Microprocessor
based Trip Unit with protection against Overload (panel should
be fitted Wall/floor), Short Circuit and Earth Fault (all with
adjustable time delays) and instantaneous protection; (2) NO/NC
contacts for operation and neutral sensor for earth fault
protection. - -
Indication - -
LED Indication Lamp for ON, OFF & TRIP. - -
LED Phase Indication Lamp for R, Y and B - -
1 No digital Voltmeter with Inbuilt Selector Switch. - -
1 No digital Ammeter with Inbuilt Selector Switch. - -
3 Nos. CTs 200/5A, 10VA, CL-1 for metering. - -
Electrolytic high conductivity FP aluminium conductor bus-bars
rated 250 Amps, suitable to withstand symetrical fault level of 25
KA for 1 second at 415 volts and with necessary heat shrinkable
Outgoings - -
5 No. 63A 4P MCCB 25 KA having Thermal Magnetic Trip Unit
with protection against Overload and Short Circuit complete as
required. - -
4 No. 63/40 A DP MCB 10 KA complete as required. - -
Electrical Panel complete as above and as required. Each 182,761.04 - -
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) Each 27,414.16 6.00 164,484.94
EXTERNAL LIGHTING FEEDER PILLAR - -
252 MR Fabrication, supplying and installation of outdoor type cubical
feeder pillar of suitable size not less than 30 cm and upto 45 cm
deep made out of M.S. sheet 2mm thick (14 SWG) duly
compartmentalized having 4 strip busbar of 100 Amp capacity
double door with locking arrangement for protection from rain,
dust, duly fixed on MS angle iron frame work of size 50mm x
50mm x 6mm (NS) 90 cm long legs out of which 45 cm duly
grouted in cement concrete 1:2:4 (1 cement : 2 sand :4 stone
aggrete 20mm) and having following accessories mouted inside
the cubical panel i/c connection, inter connection with aluminium
thimbles, earthing with two nos. earth struds duly painted with
one coat of red oxide & two coats of superior quality enamel
paint complete etc. as reqd. - -
Supplying & fixing of following accessories in the existing cubical
panel board / feeder pillar including connection testing and
having provision for energy meter inside panel etc. as reqd.
INCOMING- - -
100 A,4-pole 25 KA MCCB --1 no 40KA surge arrester/SPD. - -
OUTGOING- - -
63/40 A,4-pole 15 KA MCB --2 no - -
Power Contactor 3 pole suitable for 63 amp. --3 nos. - -
Voltmeter 0-500 V ,96 sq. mm flush type with selector switch-1
Ammeter 0- 100 A ,96 sq. mm flush type with selector switch
and CT's of suitable ratio - 1 Set. - -
Indication lamps (RYB) LED type with protection MCB's - 1 set
Rex Timer (Legrand Make) - 8 Nos. - -
SPN MCB 25 Amp - 8 Nos. - -
Danger notice plate --1 no - -
External Lighting Feeder Pillar complete as above and
required: #REF! 99,139.37 - -
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) Each 14,870.90 1.00 14,870.90
UPS PANEL - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
253 MR 1 No. 100 A, 415V, 25 kA, 4P MCCB having (1) Microprocessor
based Trip Unit with protection against Overload (panel should
be fitted in rising main/floor), Short Circuit and Earth Fault (all
with adjustable time delays) and instantaneous protection; (2)
NO/NC contacts for operation and neutral sensor for earth fault
protection. - -
Electrolytic high conductivity FP aluminium conductor bus-bars
rated 125 Amps, suitable to withstand symetrical fault level of 25
KA for 1 second at 415 volts and with necessary heat shrinkable
7 Nos. 63/40 A 4P MCCB 15 KA having Thermal Magnetic Trip
Unit with protection against Overload and Short Circuit, LED
Indication for Phase, CB 'ON', 'OFF', 'TRIP' complete as
required. - -
6 Nos. 40 A SPN MCB 15/10 KA complete as required. - -
UPS Panel complete as above and as required. #REF! 136,207.97 - -
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) Each 20,431.20 1.00 20,431.20
LIFT PANEL - -
254 MR 4 Nos. 63 A 4P MCCB 15 KA having Thermal Magnetic Trip
Unit with protection against Overload and Short Circuit, LED
Indication for Phase, CB 'ON', 'OFF', 'TRIP' complete as
required. - -
3 Nos. 40 A SPN MCB 15/10 KA complete as required. - -
Lift Panel complete as above and as required. #REF! 146,553.09 - -
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) Each 21,982.96 2.00 43,965.93
VRV OUTDOOR PANEL - -
255 MR Incomer: - -
(Note: Feeder Pillar shall be IP-67 with Stainless Steel outer
enclosure) - -
1 no. 250/400A, 415V, Ics=35kA, TPN MCCB with variable
overcurrent and short circuit releases & each complete with - -
i. 3 nos. cast resin current transformers of 200/5 ratio with 15 VA
Burden & Class 1.0 for Ammete with Ammeter selector Switch .
ii 1 Set of (0-500 volts) digital voltmeter with selector switch with 2
amps MCB‟s. - -
iii 1- set Red/Green ON/OFF indicating lamps - -
iv 1- set of three phase (red, yellow, blue) indicating lamps - -
v Amber healthy trip indicating lamps - -
Electrolytic high conductivity Aluminium three phase and neutral
busbars rated at 400 A having a maximum current density of 1.0
A per sq mm suitable to with stand symmetrical fault level of
Outgoing : - -
Tweleve (10) Nos. 40-63A TP MPCB including 5-20 KW Star
Delta Starter with thermal range of 40A - 63A. - -
Tweleve (3) Nos. 25-40A TP MPCB including 1-5 KW Dol
Starter with thermal range of 25A - 40A. - -
Starters: - -
Starter complete with AC3 duty power contactor, single phasing
preventer, ON-OFF and Trip Indicating lamps, Start/ Stop push
buttons, Auto Manual Selector Switch, auxiliary contacts for
Building Automation System & remote control, interlocking etc.
suitable for the motor KW as specified below
The switchboard shall be complete with all inter connections,
risers, internal wiring, labels etc complete as required
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) Set 52,867.30 1.00 52,867.30
Starter/Isolator Switch For VRV Outdoor / Variours Work - -
256 a SITC of 100A 3 Phase by pass switch with all accessiories as
required. Set 26,293.15 - -
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) Set 5,258.63 1.00 5,258.63
257 b Upto 5HP, DOL starter comprising 3 Nos. TP contactor AC-3
duty Auto/Manual switch, Start Stop push button, bimetallic over
current relays single phasing preventer and timer & with
potential free contacts for remote monitoring and control.
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) No. 1,544.73 2.00 3,089.46
258 c 10/7.5 HP, Star Delta starter comprising 3 Nos. TP contactor
AC-3 duty Auto/Manual switch, Start Stop push button, bimetallic
over current relays single phasing preventer and timer & with
potential free contacts for remote monitoring and control.
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) No. 1,751.63 2.00 3,503.26
259 d SITC of 63 A 4 pole isolator/RCCB switch for Outdoor/Indoor
Unit with sheet metal enclosure, rain protection etc. as
required to suit the site condition. No. 1,224.03 - -
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) No. 244.81 2.00 489.61
260 e SITC of 40 A 4 pole isolator/RCCB switch for Outdoor/ Indoor
Unit with sheet metal enclosure, rain protection etc. as
required to suit the site condition. No. 1,224.03 - -
Balance work (Lifting,shifting,positioning,installation,testing and
commissioning or any other works as required to complete in all
respect as per specification and drawing. for final handover to
NBCC / Client at their satisfaction) No. 244.81 2.00 489.61
Misc. safety equipment - -
261 MR Providing and fixing carbon dioxide(CO2) type fire extinguishers
confirming to IS 15683- 2006 and cylinders fully charged of
foloowing capacity - -
Providing and fixing ABC type fire extinguishers confirming to IS
15683- 2006 and cylinders fully charged of following capacity
c Supply and fixing safety instruction chart in word duly framed
with 5mm thick glass as required ( Approx front area 1.20
d Providing of set of 4 Nos .9.5 Ltr capacity GI bucket painted in
post office red colour with prior coat of red oxide paint and
written with white paint (fire) and mounted on MS angel iron
frame with bracket of appropriate size and capacity including
filling sand etc. Each 1,646.53 1.00 1,646.53
e Providing first aid box as approved by St.John ambulance
brigade /Indian red cross confirming to IS 2217 - 1963 Each 379.29 1.00 379.29
Providing laying and fixing of insulating mat 1 mtr wide 3mm
thick to withstand 15 KV dielectric strength as per IS 15652 - Sq.
ELECTRICAL LOW VOLTAGE WORK - -
SUBHAED-I (LOW VOLTAGE WORK) (NON-SCHEDULED
Addressable Fire Aalrm system & P.A system - -
Supply, installation, testing and commissioning of following as
per specifications : - -
262 MR Microprocessor based Inteligent and electronically addressable,
modular, Expandable networkable. 1 loops Panel Panel with
each loop capacity of 250 Devices at any combinations, loop
lenght up to 3 KM. Fire alarm control panel WIth 5.7 inch touch
screen LCD display, multiple acces levels, 10,000 event history
logs in the non volatile memory (EEPROM). The panel should
be modular microprocessor Based In natureand should be
expandable from single loop up tc 32 loops. The panel shal!
have 240V AC power supply. Autornantic battery charger, 24V .
shield lead acid maintenance free battries sufficient for 24
houres normal working and then be capable of cperatlng the
system for 30mins during emergency condtion . provision for
integration to BMS Backnet software . The panel shall be EN-
54/VDS / UL certification.
263 MR Active Repeater panel with minimum 640 Character LCD display
complete system function keys for programming and control like
system reset, Alarm Acknowledge, Alarm Silence, Trouble
Acknowledge etc. as per specification .The panel shall be EN-
54/VDS / UL certification No 79,963.85 1.00 79,963.85
264 MR Addresable monitor module with 2 monitoring features .
Monitoring Of with EOL restore Potential free contact & voltage
monitoring shlla be EN54/VDs/UL Certifications . No 4,997.85 6.00 29,987.09
265 MR Addressable Control realy modules with flexible network with
maximum switching corrent of 1A @30V DC shall be EN54/VDs
certification/UL . No 4,997.85 6.00 29,987.09
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
266 MR Addressable Heat Detector withfixed and rate of raise including
mountions base with LED. Etc. complete with require 2 isolater (
one for incoming and one for outgoing line ) integared in detector
for maintaining operational availability of all elements inthe loop
even in the event of a shor circuit & Drift compenstion features &
automatic addessing . FAP-425-DOT-RHigh resitence to
electromagnetic effects in accordable with EFSG Agreement
EFSG/F/97/005 shall be EN54/VDs/UL Certification Make (
267 MR Addressable detector with two optical sensors,one thermal and
one chemical sensor, manually and automatically with dual ray
technology including mountions base with LED. Etc. FAP-425-
DOTC-R complete with require 2 isolater ( one for incoming and
one for outgoing line) integared in detector for maintaining
operational availability of all elements inthe loop even in the
event of a shor circuit & Drift compenstion features & automatic
addessing shall be EN54/VDs/UL Certification Make (Bosch)
268 MR Addressable multisensor Smoke+Thermal detector with dual ray
technology including mountions base with LED. Etc. complete
with require 2 isolater ( one for incoming and one for outgoing
line ) integared in detector for maintaining operational availability
of all elements inthe loop even in the event of a shor circuit &
Drift compenstion features & automatic addessing shall be
EN54/VDs/UL Certification Make ( Bosch)
269 MR Supply , installtion , testing and commssioning of addressable
invisible detector for smoke optical component for flush fitting
in steel reinforced concrete ceiling or suspended ceilings having
a detection principle of two independent scattering light sensor
with sensing volumes directly beneath the detector with feature
of drift compensation , contamination detection by means of
thired optcal system , protection againest insect by means of
dual evelution system , protection againest external light in
accordance with EN-54-7,FAP‑520 chamber integrity monitoring
, optical fault display, self monitoring of sensor, programmable
of timed automatic sensitivity selection with junction box and
other accessories as required .shall be EN54/VDs/UL
Certification Make ( Bosch) No 13,327.31 - -
270 MR Addressable Manual Break glass Unit ( Double Action) with
flexible network structures & necessary fixing arragements with
keys complete as requirwd shall be EN54/VDs/UL ertification
Make (Bosch / Gramewell/Siemens/Fire Finder) No 4,164.73 14.00 58,306.22
271 MR Stand alone loop powered detector base sounder with 32
different tone various selection options & adjustable sound
pressure by 5 levels the sound pressure 92.1 db(A) with flasher
having synchorized flash rate of 1Hz and light intensity > 2cd
should be programmed from the panel shall be EN54/VDs/UL
Certification Make ; ( Bosch , Gamewell ,siemens , Fire Finder )
272 MR Response indicator with matching screw complete with GI
junction box cable lugs at cable and ferulling Make( Bosch/
Gamewell/Siemens/Fire Finder/omnitech) No 1,415.78 68.00 96,273.35
273 MR FIRE EXIT Signage with LED and battery back up and charger
with hanging arrangement complete as required
Make(Omnitech/ Heinrich /Aties ) No 5,711.33 14.00 79,958.69
Public Address System - -
274 MR Supply installation testing and commissioning of Digital PA
Controller cabable of handling 8 zones, DVA8 expandable upto
256 Zones with required size of rack.Digital audio controller
comlying to IEC EN 60849 with built-in high and low pass filters
and parametric equalizer capable of handling 8 loudspeaker
lines. Supervision of power amplifiers and hot-standby provision
for amplifier redundancy. Permenant, non-audible supervision of
loudspeaker lines also during power save mode. 4 inputs for
Automatic Volume Control. including suitable size of rack for
complete system.
275 MR Power Amplifier HPA 1480/100V
-Meets standards IED BS EN 60286-3, 55013, 55020
-Inrush restraint and softstart
-Integrated electronic protection against thermal overload and
-Temperature controlled fans, airflow from front to rear.
-Method of control: Class AB
-Power output of amplifier: 2 x 500W sin. /100V
-Output range: 50 Hz – 22kHz; 0/-0,5 dB
-Signal to noise ratio (not valuated): > 105 dB
-Channel separation: > 75 dB
-THD (total harmonic distortion): < 0,08%
-Input level at max. output voltage: 0 dBu
-The amplifier has to be switched into Stand-by Mode in case of
loss by the control centre.(Make-Bose, JBL, Aties, Heinrich)
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
276 MR Digital Call Station DV-RM -In full compliance with .
-Fully digital call station with electret microphone (cardioid-
characteristics) on flexible 300mm swan neck complete with
wideband loudspeaker for monitoring, pre-listen and intercom
operation for the networked PA system.
-Permanent inaudible supervision of the microphone and its
capsule in accordance to EN 60849.
-8 free programmable and label able keys.
-The call station shall be connectable to an interface module of
the networked PA System in startopology by CAT5 – cable and
RJ45-plug (distance up to 300 m) or by E30 fire protected cable
(distance up to 200m). -Integrated audio input with 2 Cinch-
sockets for the connection of an external source (mono) to allow
signal insertion outside the central unit.
-Optional transparent key cover to prevent accidental use of
for alarms). (Make-Bose, JBL, Aties, Heinrich)
277 MR Music source complete as required. No 20,823.65 1.00 20,823.65
278 MR Volume Controller for all the closed areas. No 3,664.69 25.00 91,617.18
279 MR 6W multitap voice alarm speaker complying with BS2839 part 8 -
line voltage 100V Ceiling speaker) No 1,082.71 50.00 54,135.47
280 MR 12W multitap voice alarm speaker wall mountable BS2839 part
DSR 2014 SCHEDULE ITEMS - -
281 1.21 Supply and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required : - -
1.21.1 Balance work (Testing ,commissioning or any other work
required of installed above item as per boq for final handover to
NBCC / Client at their satisfaction) metre 15.90 259.60 4,127.64
282 1.17 Supplying and drawing following sizes of FRLS PVC insulated
copper conductor, single core cable in the existing surface /
recessed steel / PVC conduit as required. - -
1.17.2 Balance work (Testing ,commissioning or any other work
required of installed above item as per boq for final handover to
NBCC / Client at their satisfaction) metre 10.80 378.20 4,084.56
IP EPABX SSYTEM - -
283 Supply, installation, testing and commissioning of the following
components as required. - -
MR EPABX/ IP Based Communication System equipped for 50
VoIP user license, 08 CO trunk licenses & ISDN PRI (30
channels) licenses The basic technical specifications and
essential features for the proposed IP Enabled Communication
core and the remote units / gateways the remote units /
gateways are as below : The system shall be fully digital using
Pulse Code Modulation (PCM) and Time Division Multiplex
(TDM) technique conforming shall be 100% non-blocking Call
Forwarding (Fixed Call Forwarding, System Call Forwarding,
Forced Call Forwarding, Subscriber controlled Diversion,
Delayed Call Forwarding on Busy, Network-wide Call Forward
on No Reply after Transfer, Call Forwarding on No Answer)
Voice Mail system Consisting of Voice mail Boxes for all Users ,
Auto attendted system with greeting messages PC for Attending
voice mail system Maintenance and configuration of the system
must be via a industry standard browser. MAKE:AVAYA /
ALCATEL / SIEMENS Nos 297,484.29 1.00 297,484.29
284 MR IP PHONES MODEL: IP Telephone Instruments IP Telephone
should be 2 Line Display with 2 port Integrated Ethernet Switch
10/100 Mbps . Contacts button ,Call log button, Redial
button,Speaker button ,Mute button,Headset button,Hold button
Conference button,Transfer button, Drop button .Call by name
– Call by name service must be supported from the IP phones
equipped with Alphabetical keyboard. It must allow access to the
IP PBX directory Nos 27,368.96 2.00 54,737.93
285 MR IP PHONES MODEL, for Operator Console with: The offered
console should be a PC based attendant console and it should
work on IP network & shall be supplied with required headset
Phone Call Control including Conference Call Control &
Conference Rooms; Transfer, Hold, and
Park via drag & drop.Up to 16 Park Slots with customized labels,
Monitoring of up to 8 Queues & ability to answer calls
in queue, Configuration of Phone Preferences.Local Phone
Directory, Separate Call History logs – All, Incoming, Outgoing,
Missed Calls, Messages MAKE:AVAYA / ALCATEL / SIEMENS
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
286 MR Supply, installation, testing and commissioning of normal
telephone instrument. Nos 1,290.99 10.00 12,909.89
287 MR Closed rack supports 19" wide rack-mount equipment with
Complete Accessories, Material should be of MS and lockable
with glass door. Alongwith both side cable manger pre-fitted. - -
288 MR Supply , installation, testing and commissioning of L-2-48 port-
gigabyte-10/100/1000,POE switch with 2 SFP ports. 148,147.12 1.00 148,147.12
CONDUITS AND CABLES - -
DSR'14 (DSR 2014)
289 1.21 Supply and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required : - -
FIRE FIGHTING WORKS - -
M.R. FIRE PUMPS - ELECTRICAL - -
290 Supply, installation, testing and commissioning of horizontal
single stage centrifugal type factory assembled fire pumps
suitable for autometic operation at synchoronous speed of 2900
rpm, TEFC conforming to IP-55 & flexible coupling gaurd
mounted on a common structural base plate with 150mm dia
gun metal pressure gauges with isolation cock and piping,
suitable vibration elimination pads of approved design for pump
foundation, motor to be suitable for 415 volts, 3 phase 50 cycles
Capacity 2280 LPM at 5.6 Kg/cm2 delivery pressure for Fire
Hydrant Network. Set 420,217.66 - -
Capacity 180 LPM at 5.6 Kg/cm2 (Jockey Pump). Set 115,712.11 - -
Capacity 900 LPM at 3.5 Kg/cm2 (Roof Fire Pump). Set 140,072.55 - -
Work already executed by the previous agency Set 70,036.28 - -
Work already executed by the previous agency Set 42,021.77 - -
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Set 28,014.51 - -
ROOF PANELS: - -
Supply, installation, testing and commissioning of following
integrated, cubicle type,dead front, extensible, sheet steel
control panel. The panel shall be suitable for 440 volts, 50
cycles, 4 wire supply - -
The following components and accessories shall be mounted
with ineach control panel. - -
One no 60 amps TP incoming MCCB with the following: - -
0-500 volts 96 x96 square mm voltmeter with slector switch and
control fuses- 1 SET - -
0-100 amps 96 x96 square mm ammeter with CT's and slector
switch- 1 SET - -
Phase indicating lamp with toggle switches. - -
Indication lamps for ON/OFF/TRIP status - -
Outgoing Feeders / Starters as below: - -
60 ATP MCCB with star / delta as starter suitable for 15 HP
motor for Downcomer Pump - 1 Set - -
Provision in control panel to connect flow switch for autmatic
operation of roof fire pumps. - -
291 M.R. FIRE PUMPS - DIESEL - -
Supply, installation, testing and commissioning of horizontal
single stage centrifugal pumping set with CI volute and bronze
impeller with mechanical seals directly coupled to automatic
Diesel Engine complete with all accessories like self starting by
means of Battery powered electric starter motor, Paper Filter
type air cleaner, exhaust silencer etc. complete in all respects.
The engine & the pump will be mounted on common base plate
on anti-vibration mountings. - -
Capacity 2280 LPM at 5.6 Kg/cm2 delivery pressure for Fire
Hydrant & Sprinkler Network. Set 578,560.55 - -
Exhaust piping - -
292 M.R. Providing & fixing 150 mm diameter M.S. Class 'C' diesel pump
exhaust pipe includings all fittings, like bends, tees etc. clamps /
structural steel supports. The pipe shall be provided with 75mm
thick fiberglass insulation & covering the insulation with 500 g
polythene sheet giving proper overlaps & sealing the joints with
suitable adhesive compound. The pipe shall be provided with 24
gauge aluminium sheet cladding RM 1,803.65 20.00 36,072.95
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
293 M.R. Supplying, installation, testing and commissioning of
annunciation panel made out of not less 1.6 mm thick CRCA
sheet powder coated in approved colour with locking
arrangement, audio and visual indication of fault and operation
of automatic sprinkler, system monitoring including providing
and fixing the following, connections interconnections etc.
complete as required. The Panel shall be Micro processor
type/solid state type.* Set 25,958.77 - -
Monitoring 4 Nos. of flow switches. - -
Monitoring the open circuit, short circuit & earth fault in control
cable between panel and flow switches. - -
Work already executed by the previous agency Set 20,767.01 1.00 20,767.01
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Set 5,191.75 1.00 5,191.75
294 M.R. PRESSURE SWITCH - -
Supplying, installing, testing and commissioning 0 to 12 Kg/ cm2
ON/OFF pressure switch in delivery line of pump along with
control wiring for auto starting and auto stopping of hydrant and
jockey pumps. Each 5,312.49 7.00 37,187.44
295 M.R. Supply, fabrication (as per code), installation, testing and
commissioning of Pressure vessels 450mm diameter and
1000mm high fabricated from 8-10mm M.S. plate with
accessories inside painting with epoxy paint and outside with
296 M.R. Providing, fixing, testing & commissioning of resilient rubber
lined single arch vibration eliminators suitable for raw water up to
45 deg. C temperature, working pressure 8.8 Kg/cm2 and test
pressure 14 Kg/cm2 for :- - -
297 M.R. Supply, installation, testing, trial run and commissioning of
hydrants all complete as required and as approved - -
Fire Hose Cabinet - -
298 1.6mm thick MS door frame 900x2100 door capable of
accommodating fire hose reel, landing valve, hose pipes, fittings
& accessories. The door shall have a front glass with lock and
key arrangement & shall be painted with post office red colour
(approval shall be taken on the basis of submitted sample before
ordering) Cost of fire extinguishers not included in item rate.
(Liasioing with civil contractor for making 900x600x2100
Recessed type mansoary box (by civil contractor).
Work already executed by the previous agency Each 12,037.68 12.00 144,452.11
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Each 3,009.42 12.00 36,113.03
299 TAC approved 1.6mm thick M.S. fire hose cabinet
(750x600x250mm) made out of 16 gauge M.S. sheet capable of
accommodating landing valve, hose pipes, fittings &
accessories. The box shall have a front glass door with lock and
key arrangement & shall be painted with post office red colour
(approval shall be taken on the basis of submitted sample before
ordering) - for external and roof hydrant. Each 4,388.74 6.00 26,332.42
300 63mm dia single outlet GM landing valve IS marked with suitable
size bolts, nuts, washers and gaskets. Landing valve shall be
TAC Approved Make. Each 6,124.68 16.00 97,994.94
63mm dia twin outlet GM landing valve IS marked with suitable
size bolts, nuts, washers and gaskets. Landing valve shall be
TAC Approved Make. Each 13,124.32 - -
Work already executed by the previous agency Each 10,499.46 - -
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Each 2,624.86 - -
301 First aid hose reel with 25 mm dia, 30 m long rubber hose, ball
valve, piping and GM nozzle Each 5,374.72 - -
Work already executed by the previous agency Each 4,299.78 12.00 51,597.34
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Each 1,074.94 12.00 12,899.33
302 63mm reinforced rubber hoses (RRL) with male and female GM
coupling, IS marked- 15 m long Each 4,437.27 - -
Work already executed by the previous agency Each 3,549.82 32.00 113,594.13
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Each 887.45 32.00 28,398.53
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
303 standard short size GM branch pipe with nozzle of 20mm
nomnal bor outlet with instaneous type 63 mm dia coupling
complete IS marked & TAC approved. Each 1,937.40 - -
Work already executed by the previous agency Each 1,549.92 16.00 24,798.72
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Each 387.48 16.00 6,199.68
304 Fire Axe Each 687.46 - -
Work already executed by the previous agency Each 549.97 12.00 6,599.66
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Each 137.49 12.00 1,649.91
305 M.R. Supply, installation, testing and commissioning ss orifice plates
in pipelines to reduce pressure from 8 kg. to 3.5 kg/sq.cm.
306 M.R. Providing, installing, testing & commisioning of fire brigade inlet
connection (fire department connection) consisting of 4 Nos. 63
mm dia instantaneous inlet arranged on a 50 mm dia header, 1
No. 150 mm diameter Butterfly valve, 1 No. 150mm dia. Non-
return valve and wall mounted box of M.S. construction with
glass door to house the above mentioned components.
Work already executed by the previous agency Set 18,954.02 3.00 56,862.06
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Set 4,738.51 3.00 14,215.52
307 M.R. Providing, installing, testing & commisioning of fire brigade draw
out connection (fire department connection) with suction pipe
MS class 'C' 100 mm dia. & 100 mm dia. foot valve & steel chain
including wall mounted box M.S. construction with glass door to
house the above mentioned componenets. Set 14,227.39 - -
Work already executed by the previous agency Set 11,381.91 1.00 11,381.91
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Set 2,845.48 1.00 2,845.48
308 DSR' 14 Excavating trenches of required width for pipes, cables, etc
ITEM NO including excavation for sockets, and dressing of sides, ramming
2.10 of bottoms, depth upto 1.5 m including getting out the excavated
soil, and then returning the soil as required, in layers not
exceeding 20 cm in depth including consolidating each
deposited layer by ramming, watering, etc. and disposing of
surplus excavated soil as directed, within a lead of 50 m :
2.10.1 All kinds of soil - -
2.10.1.2Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300
mm dia. Cum 208.30 - -
309 DSR,14 Providing and fixing up to floor five level precast cement
ITEM NO concrete string or lacing courses, copings, bed plates, anchor
4.5 blocks, plain window sills, shelves, louvers, steps, stair cases,
etc. including hoisting and setting in position with cement mortar
1:3 (1 Cement : 3 coarse sand), cost of required centering,
shuttering and finishing smooth with 6mm thick cement plaster
1:3 (1 Cement : 3 fine sand) on exposed surfaces complete.
4.5.2 1:2:6 (1 cement : 32coarse sand : 6 graded stone aggregate
20mm nominal size). Cum 6,269.80 - -
310 DSR'14 Constructing masonary chamber 90 x 90 x100 cm. inside with
Item common burnt clay F.P.S. (non modular) brick of designation 75
18.34.1 mm in cement mortar 1:4 ( 1 cement : 4 fine sand) for sluice
valve with CI surface box 100 mm top dia. 160 mm bottom dia.
And 180 mm deep (inside) with chained lid and RCC top slab
1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size) necessary excavation foundation concrete
1 :5 :10 (1 cement : 5 fine sand : 10 graded stone aggregate 40
mm nominal size and inside plastering with 1:3 (1 cement : 3
coarse sand) 12 mm thick finished with a floating coat of neat
cement complete as per standard design with FPS bricks
311 18.59 Providing and fixing C.I. double acting air valves of approved
quality with bolts, nuts, rubber insertions etc. complete ( The tail
pieces, tapers etc. if reqd. will be paid separately) - -
312 18.31 Providing & Fixing C.I.sluice valve(with cap) complete with
bolts,nuts,rubber insertions etc.(the tail pieces if required will be
paid separately) - -
18.31.3 150 mm dia.pipe - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
SUBHEAD-II(B):PIPING FOR FIRE FIGHTING SYSTEM (NON SCHEDULED ITEMS) - -
313 Providing laying, testing & commissioning of “C” class heavy
duty MS pipe conforming to IS 1239/3589 (all pipes shall be ISI
marked and of makes specified in the specifications) i/c fittings
like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in
ground including excavation & providing cement concrete
blocks as supports and anti-corrosive treatment to burried pipes
by wrapping & coating with 4 mm thk. (OR 2 COATS of 2mm
thick tape) anticorrosion tape along with two coat of black japan
primer for under-ground pipe including digging and backfilling
upto 1.0 mtr. below from G.L.for external work as per IS-909
(Specification for Underground Fire Hydrant Make: Jindal Hissar/
Surya/ Tata/ SAIL. (Under ground)
M.R. 150 nominal bore (class C) M 1,963.55 150.00 294,532.57
M.R. 100 nominal bore (class C) M 1,409.20 50.00 70,459.79
314 Supply and installation of Butterfly Valves of rating PN 1.6 with
mating flanges generally as specified all complete. - -
M.R. 150 nominal bore Each 4,001.92 8.00 32,015.37
M.R. 100 nominal bore Each 2,843.47 8.00 22,747.76
M.R. 200 nominal bore Each 12,111.08 2.00 24,222.15
315 Providing and laying cast iron non-return valve of rating PN 1.6
dule ISI marked with flanges generally as specified complete
M.R. 150 nominal bore Each 11,508.45 6.00 69,050.69
M.R. 100 nominal bore Each 7,430.47 1.00 7,430.47
M.R. 200 nominal bore Each 20,073.96 - -
316 M.R. Supply, installation testing & commissioning double flanged 'Y'
strainers with M.S. body and SS 40-grade mesh strainer. - -
150 nominal bore Each 9,010.29 3.00 27,030.87
Threaded joint upto 50mm diameter pipe. - -
Welded joint above 50mm diameter pipe. - -
317 M.R. 150 mm nominal bore (class C) Rm 1,830.44 80.00 146,434.84
318 M.R. 100 mm nominal bore (class C) Rm 1,276.22 47.50 60,620.64
319 M.R. 80 mm nominal bore (class C) 893.63 - -
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Rm 89.36 310.00 27,702.66
320 M.R. 65 mm nominal bore (class C) Rm 752.65 - -
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Rm 75.26 246.00 18,515.08
321 M.R. 50 mm nominal bore (class C) Rm 594.46 - -
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Rm 59.45 190.00 11,294.71
322 M.R. 40 mm nominal bore (class C) Rm 444.80 - -
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Rm 44.48 343.00 15,256.62
323 M.R. 32 mm nominal bore (class C) Rm 394.29 - -
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Rm 39.43 545.00 21,488.96
324 M.R. 25 mm nominal bore (class C) Rm 325.11 - -
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Rm 32.51 1,055.00 34,299.62
SUBHEAD-III(B): SPRINKLER SYSTEM (NON SCHEDULED ITEMS) - -
325 M.R. Supply, installation, testing and commissioning of 150 mm dia
Installation Control Valve inclusive of 2 nos 150 mm dia Butterfly
Valve, strainer, Alarm Valve with Water Motor Gong, Pressure
Gauges, Test Lines with Ball Valves with necessary GI (H)
piping with threaded fittings of required sizes complete
Work already executed by the previous agency Set 50,227.19 1.00 50,227.19
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Set 12,556.80 1.00 12,556.80
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
326 M.R. Supply, installation, testing and commissioning of 150 mm dia
Zonal Control Valve inclusive of 1 nos 150 mm dia butterfly
valve, 150mm diam. non return valve, Flow Switch, water
pressure gauges & 25 mm dia. Auxillary Drain valve with sight
glass with necessary GI (H) piping with threaded fittings of
required sizes complete Set 48,174.64 - -
Work already executed by the previous agency Set 38,539.71 6.00 231,238.27
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Set 9,634.93 6.00 57,809.57
327 M.R. Providing, fixing, testing and commissioning of quick response
15 mm dia. gunmetal quartz bulb type sprinkler head to operate
at 68 degree centigrade - -
Pendent type Each 377.59 - -
Work already executed by the previous agency Each 302.07 130.00 39,269.04
Balance work (Installation,testing and commissioning or any
other work as required complete in all respect as per
specification and drawing for final handover to NBCC / Client at
their satisfaction) Each 75.52 274.00 20,691.76
SUBHEAD- IV (B): FIRE EXTINGUSHER (NON SCHEDULED ITEMS) - -
328 M.R. Providing & fixing of 2kg clean agent gas based residue free
stored pressure FE-36 Dupont- HFC-236fa
(HEXAFLUOROPROPANE – CF3-CH2-CF3) multipurpose type
having 0% ODP with magnetic pressure gauge having the
facility to check with the magnetic pressure kit on site
pressurised by dry nitrogen, can height 341MM, diamater is 108
MM Gross weight 3.6Kg, empty weight 1.6 Kg, discharge time is
minimum 6 sec, controllable discharge machanisim, embossed
fire rating as per the BS EN 3- 21B, BIS 15683 marked with
EPDM Hose with helium leak detection tested and certificate
enclosed, range 4 mtr with plastic yellow safety seal with pull
marked on it, Warranty 5 year.
Capacity 2.0 kg Nos. 6,249.68 - -
329 M.R. Providing & Fixing of stored pressure Fire Extinguisher ABC
powder type (Mono Ammonium Phosphate Powder) Magnetic
Pressure Gauge having the facility to check at site, Discharge
Time less than 9 Secs, Controllable discharge mechanism,
Range minimum 4 Meters, applicable on Class A,B,C and
electrically started Fire, A Rating- 21A, B Rating 55B as per BS
EN-3 BIS 15683 marked, Can Construction : Deep drawn & CO2
Mig welded, Valve Construction : Forging & Machining, Internal
Coating of Can : Epoxy Powder coating, External Coating ofCan
: Epoxy Polyster Powder coating, Sheet metal thickness :
1.60MM, Helium LeakDetection Tested, Warranty 5 Years.
Make CEASEFIRE / Minimax - -
330 MR Providing and fixing mechanical foam type Trolley Mounted
Fire Extinguisher of bearing to IS:10568/IS13385/IS13386 with
331 MR Providing and fixing Carbon Dioxide Type Trolley Mounted Fire
Extinguisher of as per IS: 2878 with discharge time of 10 to 20
sec/15 to 36sec/20 to 60sec respectively. - -
22.5 Kg. CO2 Fire Extinguisher Nos. 14,999.23 1.00 14,999.23
SUBHEAD-V (B): FIRE ELECTRICAL WORKS (NON SCHEDULED ITEMS) - -
332 MR Fabricating, supplying, testing and commissioning of electrical
control panel of cubicle construction, floor mounted type,
fabricated out of 2mm thick crca sheet, compartmentallised and
hinged lockable doors, dust and vermin proof, powder coated
approved shade after 7 tank treatment process, cable alley
interconnection, having switchgears and accessories mounting
and internal wiring, earth terminals, numbering etc., complete in
all respects, suitable for operation on 415V, 3 phase 50 Hz., AC
supplywith enclosure protection class IP-42as required.
COMMON PANEL IN FIRE PUMP HOUSE. - -
400 Amps. TP & N SFU with HRC fuses. - -
Voltmeter (0-500 Volts) with selector switch. - -
Ameter (0- 400 Amps.) with selector switch & CT's etc. - -
Set of 3 phase indicating lamp. - -
Set of Al. bus bar 200 Amps. - -
OUTGOING. - -
Main fire pump and Sprinkler pump - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
200 Amps. TP& N SFU with HRC fuses with suitable HP fully
automatic star/delta starter with over load protection, current
sensing type single phase preventor complete with all
acessories and internal wiring required for automatic operation,
selector switch for local / remote, auto/ manual OFF operation.
Jockey pump - -
40 Amps. TP& N SFU with HRC fuses with suitable HP fully
automatic star / delta starter with over load protection, current
sensing type single phase preventor complete with all
accessories and internal wiring required for automatic operation,
selector switch for local / remote, auto / manual / OFF operation.
Diesel Engine Control - -
Control for Diesel Engine comprising:- - -
Auto / Manual selector switch & 3 attempt starting device, timers
and relays as required, push buttons, start / stop in manual
Indication lamp for High / Low Lub. Oil pressure, High Water
Temp. and Engine ON indication. - -
Battery charger suitable for 12V / 24 V DC with boost and tickle
selector switch, 0-30 V DC volt meter, 0-20A DC Ammeter.
All standard relays and acessories for automatic operation of
diesel engine. - -
DIESEL ENGINE CONTROL - -
Control for Diesel Engine comprising:- - -
Auto / Manual selector switch & 3 attempt starting device, timers
and relays as required, push buttons, start / stop in manual
Indication lamp for High / Low Lub. Oil pressure, High Water
Temp. and Engine ON indication. - -
Battery charger suitable for 12 V / 24 V DC with boost and tickle
selector switch, 0-15 V / 0-30 V DC volt meter, 0-20A DC
MAIN FIRE PUMP CONTROL - -
200 Amps. TP&N SFU with HRC fuses - -
Voltmeter (0-500 Volts) with selector switch. - -
Ammeter (0-200 Amps.) with selector switch, CTs etc. - -
Set of 3 phase indication lamp. - -
Suitable HP fully automatic Star / Delta Starter with over load
protection, current sensing type single phase preventor complete
with all acessories and internal wiring required for automatic
operation. - -
Selector switch for local / remote, auto / manual / off operation.
SYSTEM CONTROLLER - -
Designing, Supply, Installation, Testing and Commissioning of
system controller to control operation of Main Electric Fire Pump,
Diesel Pump, Pressurisation Pump, Terrace Pump in sequence
as per specification consisting of relays, timets, sensors,
annunciation window for fault indication, complete as per
specification. - -
SUBHEAD- IV: FIRE ELECTRICAL WORKS (DSR 2014) - -
333 5.3 Supplying and Earthing with GI earth plate 600mm x 600 mm x
6mm thick including accessories and providing masonary
enclosure with cover plate having locking arrangement and
watering pipe etc, with charcoal/ coke and salt as required.
334 5.11 Supplying and laying 25 mm x 5 mm. G.I. strip in 40 mm dia.
G.I. Pipe from earth electrode, as required.
335 5.15 Providing & fixing 25mm x 5mm G.I. strip on surface or in recess
for connections etc. as required.
336 5.18 Providing and Fixing 6 SWG dia G.I. wire on surface or in recess
for loop earthing alongwith existing surface/ recessed conduit/
submain wiring/ cable as required.
337 4.1 Supplying, fabricating and installing following size of perforated
M.S. cable trays, including horizontal and vertical bends,
reducers, tees, cross members and other accessories as
required and duly suspended from the ceiling with M.S.
suspenders and including paint - -
4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness Rm 461.00 40.00 18,440.00
4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness Rm 789.00 30.00 23,670.00
338 7.7.1 Laying and fixing of One number PVC Insulated and PVC
Sheathed/XLPE power cable of 1.1 kV grade of size not
exceeding 25 sqmm on surface as required. RM 24.00 - -
339 7.7.3 Laying and fixing of One number PVC Insulated and PVC
Sheathed/XLPE power cable of 1.1 kV grade of size exceeding
25 sqmm but not exceeding 120 sqmm on surface as required.
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
340 9.1 Supplying of all materials and making terminations of 1.1 KV
grade aluminium multicore cables of the following sizes. The
work includes cable glanding using brass plated double
compression glands, sizing the core leads, removing insulation,
fixing suitable crimping type copper lugs/ thimbles by using
hydraulic crimping tools with correct size of the dies, shaping the
leads and neatly connecting the same to the equipment
terminals. - -
9.1.25 3.5 Core 120 sq. mm. Armoured Aluminium cable. Mtr 484.00 - -
9.1.21 3.5 Core 35 sq. mm. Armoured Aluminium cable. Mtr 270.00 - -
9.1.8 3.5 Core 16 sq. mm. Armoured Aluminium cable. Mtr 192.00 20.00 3,840.00
341 Control Cabling (PVC insulated and PVC sheathed, armoured,
Copper Conductor of 1.1 KV grade on existing cable trays).
EXTERNAL DEVELOPMENT & BULK SERVICES (CIVIL & ELECTRICAL) - -
EXTERNAL SEWERAGE SYSTEM - -
SEWERAGE NETWORK - -
(D.S.R. 2014 ITEMS) - -
342 Excavating trenches of required width for pipes, cables, etc
including excavation for sockets, and dressing of sides, ramming
of bottoms, depth upto 1.5 m, including getting out the
excavated soil, and then returning the soil as required, in layers
not exceeding 20 cm in depth, including consolidating each
deposited layer by ramming, watering, etc. and disposing of
surplus excavated soil as directed, within a lead of 50 m :
2.10.1 All kinds of soil - -
up to 1.50 m depth - -
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300
mm dia metre 208.30 - -
2.10.1.2 Work already executed by the previous agency metre 166.64 - -
2.10.1.2 Balance work (Repairing or any other work as required to handig
over in all respect to NBCC / Client at their satisfaction)
343 2.11 Extra for excavating trenches for pipes, cables etc. in all kinds of
soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate
is over corresponding basic item for depth upto 1.5 metre).
344 19.10 Providing laying and jointing glazed stoneware pipes grade „A‟
with stiff mixture of cement mortar in the proportion of 1:1 (1
cement : 1 fine sand) including testing of joints etc. complete. - -
19.1.2 150 mm diameter
345 Providing and laying cement concrete 1:5:10 (1 cement : 5
coarse sand : 10 graded stone aggregate 40 mm nominal size)
alround SW pipes including bed concrete as per standard
19.2.2 150 mm diameter metre 724.70 - -
19.2.2 Work already executed by the previous agency metre 579.76 - -
19.2.2 Balance work (Repairing or any other work as required to handig
over in all respect to NBCC / Client at their satisfaction)
346 19.60 Providing and laying Non pressure NP 2 class (light duty) RCC
pipe with collars jointed with stiff mixture of cement mortar in
the proportion of 1:2 (1cement : 2 fine sand ) including testing
of joints etc. complete.
19.6.3 250 mm. dia. RCC Pipes metre 468.60 - -
19.6.3 Work already executed by the previous agency metre 374.88 - -
19.6.3 Balance work (Repairing or any other work as required to handig
over in all respect to NBCC / Client at their satisfaction)
347 4.1.8 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering. (for RCC
pipe bedding) by 1:4:8 (1 cement : 4 coarse sand : 8 graded
stone agg. 40 mm nominal size)
348 19.70 Constructing brick masonry manhole with F.P.S. bricks in
cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab
with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone
aggregate 20mm nominal size); foundation concrete 1:4:8 mix
(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm
nominal size) inside plastering 12 mm thick with cement
mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat
of neat cement and making channels in cement concrete 1:2:4
(1cement : 2 coarse sand: 4 graded stone aggregate 20 mm
nominal size) finishd with a floating coat of neat cement
complete as per standard design
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
19.7.1.1 Inside size 90 x 80 cm & 45 cm deep including CI cover with
frame (light duty) 455 x 610mm internal dimension total wt. of
cover & frame to be not less than 38 kg (wt. of cover 23 kg and
wt. of frame 15 kg)
349 19.7.2.1 Inside size 120 X 90 cm. and 90 cm. deep including CI cover
with frame (medium duty) 500 mm internal diameter, total weight
of cover and frame to be not less than 116 kg (wt of cover 58 kg
and wt. of frame 58 kg.)
19.7.2.1 Work already executed by the previous agency each 5,491.34 - -
19.7.2.1 Balance work (Repairing or any other work as required to handig
over in all respect to NBCC / Client at their satisfaction)
350 Extra for depth for manhole with F.P.S. bricks - -
351 2.80 Earth work in excavation by mechanical means(Hydraulic
excavator)/manual means in foundation trenches or drains(not
exceeding 1.5 m in width or 10 sqm on plan), including dressing
of sides and ramming of bottoms, lift upto 1.5 m, including
getting out the excavated soil and disposal of surplus excavated
soil as directed, within a lead of 50 m - -
2.8.1 All kinds of soil Cum 157.50 20.00 3,150.00
352 13.40 12 mm cement plaster of mix - -
353 19.16 Providing orange colour safety foot rest of minimum 6 mm thick
plastic encapsulated as per IS : 10910, on 12 mm dia steel bar
conforming to IS : 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as
165 mm with minimum 112 mm space between protruded legs
having 2 mm tread on top surface by ribbing or chequering
besides necessary and adequate anchoring projections on tail
length on 138 mm as per standard drawing and suitable to with
stand the bend test and chemical resistance test as per
specifications and having manufacture's permanent identification
mark to be visible even after fixing, including fixing in manholes
with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal size)
complete as per design.
354 Providing and fixing square mouth SW gully trap grade „A‟
complete CI grating brick masonry chamber with bricks of class
designation 75 and water tight CI cover with frame of 300 x 300
mm size (inside) the weight of cover to be not less than 13.00 kg
and frame to be not less than 5 kg. as per standard design.
(COVER MIN. 4.5 KG & FRAME MIN.2.7 KG )
19.4.3.1 180x150 mm size P type With FPS bricks each 1,678.85 3.00 5,036.55
355 19.21.1 Making connection of drain or sewer line with existing manhole
including breaking into and making good the walls, floors with
cement cincrete 1:2:4 mix (1cement: 2 coarse sand : 4 graded
stone aggregate 20mm nominal size) cement plastered on both
sides with cement mortar 1:3 (1cement : 3 coarse sand) finished
with a floating coat of neat cement and making necessary
channels for the drain etc. complete for pipes 100 to 230mm dia.
EXTERNAL DRAINAGE SYSTEM - -
DRAINAGE NETWORK - -
356 19.60 Providing and laying non-pressure NP2 class (light duty) RCC
pipes with collars jointed with stiff mixture of cement mortar in
the proportion of 1:2 (1 cement : 2 fine sand) including testing of
joints etc. complete. (for storm drainage) - -
19.6.4 300 mm dia RCC pipe Meter 506.35 - -
19.6.4 Work already executed by the previous agency Meter 303.81 - -
19.6.4 Balance work (Repairing or any other work as required to handig
over in all respect to NBCC / Client at their satisfaction)
357 4.10 Providing and laying in position cement concrete of grade
excluding the cost of centering and shuttering - all work up to
plinth level - -
358 4.1.10 1:5:10 (1 cement : 5 coarse sand : 10 graded ston aggregate 40
mm nominal size) CUM 4,004.00 10.00 40,040.00
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
359 Constructing brick masonry road gully chamber 50x45x60 cm
with bricks of class designation 75 in cement mortar 1:5 (1
cement : 5 fine sand) including 500 x 450 mm (heavy duty)
precast RCC horizontal grating with frame complete as per
standard design: - -
19.27.1 with FPS bricks
RAIN WATER HARVESTING - -
DESILTING CHAMBER (1 No.) - -
360 2.60 Earth work In excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30cm in depth.
1.5m in width as per as 10 sq.m on plan) including disposal of
excavated earth, lead up to 50m and lift up to 1.5m, disposed
earth to be levelled and neatly dressed.
2.6.1 All kinds of soil Cu.M 155.60 8.40 1,307.30
361 2.25 Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating Each deposited layer by ramming and
watering , lead up to 50 m and lift up to 1.5m.
2.26 Extra for every additional lift of 1.5 m or part there of in: - -
2.26.1 All kinds of soil. Cu.M 46.25 3.65 168.81
362 4.10 Providing and laying in position cement cncrete of specified
grade excluding the cost of centring and shuttering - all work
upto plinth level.
4.1.8 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 40
mm nominal size) Cu.M 4,301.15 0.30 1,290.35
363 5.90 Centring and shuttering including strutting, proppintg etc. and
removal of form for: - -
5.9.3 Suspended floors,roofs, landings, balconies and access
364 5.9.16 Edges of slabs and breaks in floors and walls, - -
365 5.22 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level. - -
5.22.6 Thermo Mechanically Treated bars. Kg. 68.10 23.55 1,603.76
366 5.33 Providing and laying in position machine batched and machine
mixed design mix M-25 grade cement concrete for reinforced
cement concrete work, using cement content as per approved
design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and
reinforcement, including admixtures in recommended
proportions as per IS: 9103 to accelerate, retard setting of
concrete, improve workability without impairing strength and
durability as per direction of Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330
kg/cum. Excess/less cement used as per design mix is
payable/recoverable separately). - -
5.33.1 All works upto plinth level. Cu.M 6,296.15 1.50 9,444.23
367 6.10 Brick work with F.P.S. bricks of class designation 75 in
foundation and plinth in: - -
6.1.1 Cement mortar 1:4 (1 cement: 4 coarse sand) Cu.M 4,918.65 3.00 14,755.95
368 13.1.1 12 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand).
369 19.10 Providing, laying and jointing glazed stoneware pipes grade 'A'
with stiff mixture of cement mortar in the proportion of 1:1 (1
cement: 1 fine sand) including testing of joints etc. complete:
370 24.70 Supplying, filling, spreading & leveling coarse sand of size range
1.5 mm to 2 mm in recharge pit, in required thickness over
gravel layer, for all leads & lifts, all complete as per direction of
Engineer –in-charge. Cu.M 852.60 0.27 230.20
371 19.19 Providing and fixing in position pre-cast R.C.C. manhole cover
and frame of required shape and approved quality - -
19.19.1.1 Rectangular shape 600x450mm internal dimensions Each 1,131.70 2.00 2,263.40
RECHARGE PIT (1 No.) - -
DSR ITEMS - -
372 2.80 Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or drains (not
exceeding 1.5m in width or 10 Sq.M on plan) including dressing
of sides and ramming ob bottoms, lift upto 1.5m, including
getting out the excavated soil and disposal of surplus excavated
soil as directed, withen a lead of 50m.
2.8.1 All kinds of soil Cu.M 157.50 59.17 9,319.28
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
373 2.26 Extra for every additional lift of 1.5 m or part thereof in
excavation /banking excavated or stacked materials. - -
(a) Depth exe. 1.5m but not exceeding 3.0m. Cu.M 46.25 22.60 1,045.25
(b) Depth exe. 3.0m but not exceeding 4.5m. Cu.M 82.95 15.05 1,248.40
374 2.25 Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating Each deposited layer by ramming and
watering , lead up to 50 m and lift up to 1.5m.
375 4.10 Providing and laying in position cement cncrete of specified
grade excluding the cost of centring and shuttering - all work
upto plinth level. - -
4.1.8 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 40
mm nominal size) Cu.M 4,301.15 0.90 3,871.04
376 5.90 Centring and shuttering including strutting, proppintg etc. and
removal of form for: - -
5.9.3 Suspended floors,roofs, landings, balconies and access
377 5.9.16 Edges of slabs and breaks in floors and walls, - -
378 5.22 Reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete.
5.22.6 Thermo Mechanically Treated bars. Kg. 68.10 175.00 11,917.50
379 5.33 Providing and laying in position machine batched and machine
mixed design mix M-25 grade cement concrete for reinforced
cement concrete work, using cement content as per approved
design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and
reinforcement, including admixtures in recommended
proportions as per IS: 9103 to accelerate, retard setting of
concrete, improve workability without impairing strength and
durability as per direction of Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330
kg/cum. Excess/less cement used as per design mix is
payable/recoverable separately). - -
5.33.1 All works upto plinth level. Cu.M 6,296.15 1.48 9,318.30
380 6.10 Brick work with F.P.S. bricks of class designation 75 in
foundation and plinth in: - -
6.1.1 Cement mortar 1:4 (1 cement: 4 coarse sand) Cu.M 4,918.65 5.00 24,593.25
381 13.1.1 12 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand).
382 19.10 Providing, laying and jointing glazed stoneware pipes grade 'A'
with stiff mixture of cement mortar in the proportion of 1:1 (1
cement: 1 fine sand) including testing of joints etc. complete:
383 24.70 Supplying, filling, spreading & leveling coarse sand of size range
1.5 mm to 2 mm in recharge pit, in required thickness over
gravel layer, for all leads & lifts, all complete as per direction of
Engineer –in-charge. Cu.M 852.60 1.50 1,278.90
384 24.10 Boring/drilling bore well of required dia for Casing/ strainer pipe,
by suitable method prescribed in IS: 2800 (part I), including
collecting samples from different strata, preparing and
submitting strata chart/bore log, including hire & running charges
of all equipments, tools, plants & machineries required for the
job, all complete as per direction of Engineer –in-charge, upto 90
metre depth below ground level. - -
24.1.1 All types of soil - -
385 24.30 Supplying, assembling, lowering and fixing in vertical position in
bore well, unplasticized PVC medium well casing (CM) pipe of
required dia, conforming to IS: 12818, including required hire
and labour charges, fittings & accessories etc. all complete, for
all depths, as per direction of Engineer –in-charge.
386 24.60 Supplying, filling, spreading & leveling gravels of size range 4.6
mm to 4.8 mm, in the recharge pit, over the existing layer of
boulders, in required thickness, for all leads & lifts, all complete
as per direction of Engineer-in-charge. Cu.M 910.65 4.90 4,462.19
387 24.50 Supplying, filling, spreading & leveling stone boulders of size
range 5 cm to 20 cm, in recharge pit, in the required thickness,
for all leads & lifts, all complete as per direction of Engineer-in-
388 19.19 Providing and fixing in position pre-cast R.C.C. manhole cover
and frame of required shape and approved quality - -
19.19.1.1 Rectangular shape 600x450mm internal dimensions Each 1,131.70 2.00 2,263.40
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
389 9.50 Providing and fixing hard drawn steel wire fabric 75x25 mm
mesh of weight not less than 7.75 Kg per sqm to window frames
etc. including 62x19 mm beading of second class teak wood and
priming coat with approved steel primer all complete.
RAIN WATER 1 nos. HARVESTING (NON-SCHEDULED
390 MR Providing, fixing, testing and commissioning of uPVC waste pipe
conforming to IS : 4985-2000 class IV (6 Kg/Sq.cm) including all
moulding fittings conforming to IS : 7834 (Part I to Part-7) 1987
such as tees, bends, reducers, coupling, adaptor etc. solvent
welded joints as per manufacturer recommendation including
cutting and making good the walls, floors, R.C.C. work etc. (For
OVER FLOW). - -
210 mm OD UPVC Pipe metre 1,200.62 20.00 24,012.39
EXTERNAL WATER SUPPLY SYSTEM - -
DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY - -
(D.S.R. 2014 ITEMS) - -
391 18.12 Providing and fixing G.I. pipes complete with G.I. fittings
including ,trenching and refilling etc. - -
external works - -
18.12.1 15mm nominal bore metre 186.25 5.00 931.25
18.12.2 25mm nominal bore metre 209.95 5.00 1,049.75
18.12.6 50mm nominal bore metre 399.50 185.00 73,907.50
18.12.7 65mm nominal bore metre 524.25 10.00 5,242.50
18.12.8 80mm nominal bore metre 637.05 25.00 15,926.25
392 Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) : - -
external works - -
18.17.1 25mm nominal bore Each 428.85 4.00 1,715.40
18.17.4 50mm nominal bore Each 750.75 2.00 1,501.50
393 Providing and filling sand of grading zone V or coarser grade all-
round the G.I. pipes in external work. - -
18.41.1 15mm nominal bore metre 66.40 15.00 996.00
394 18.59 Providing and fixing C.I. double acting air valve of approved
quality with bolts, nuts, rubber insertions etc. complete (The tail
pieces, tapers etc if required will be paid separately) :
395 18.32.1 Constructing masonry chamber 30x30x50 cm,inside with 75
class designation brick work in cement mortar 1:4 (1 cement:4
coarce sand) for stop cock complete with C.I. surface box
100x100x75mm (inside) with locking arrangement and RCC top
slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr
aggregate 20mm nominal size) necessary excavation foundation
concret 1:5:10 (1 cement:5 fine sand : 10 graded stone
aggregate 40 mm nominal size) and inside plastering with
cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick
finished with a floating coat of neat cement complete as per
standard design.
396 DSR 18.33 Constructing masonry Chamber 60X60X75 cm, inside with 75
class designation brick work in cement mortar 1:4 (1 cement: 4
coarse sand) for sluice valve, with C.I. surface box 100 mm top
diameter, 160 mm bottom diameter and 180 mm deep (inside)
with channel lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse
sand: 4 graded stone sggregate 20 mm nominal size) necessary
excavation foundation concrete 1:5:10 (1 cement : 5 fine sand:
10 graded stone aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12
mm thick finished with a floating coat of neat cement complete
as per standard design: - -
397 2.10 Excavating trenches of required width for pipes, cables etc.
including excavation for sockets and dressing of sides, ramming
of bottom depth upto 1.5 M including getting out the excavated
soil (HARD OR SOFT) and then returning the soil as required in
layers not exceeding 20 cms in depth including consolidating
each deposited layer by ramming, watering etc. and disposing of
surplus excavated soil as directed within a lead of 50m.
[hard/Dense soil] - -
2.10.1 All kind of soil - -
2.10.1.2 Pipes,cables etc.exceeding 80mm dia.but not exceeding 300mm
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
398 DSR 2.11 Extra for excavating trenches for pipes, cables etc. in all kinds of
soil for depth exceeding 1.5m,but not exceeding 3 m.(Rate is
over corresponding basic item for depth up to 1.5 metre). Mtr. 236.63 8.00 1,893.03
399 10.20 Structual steel work welded in built up sections, trusses and
framed work including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer all complete.
400 18.13.2 Making connection of GI distribution branch with GI main of 50-
80mm nominal bore by providing and fixing tee, including cutting
and threading the pipe etc. complete. Item 761.10 2.00 1,522.20
401 ELECT. Providing and fixing GI pipes medium class conferming to IS
DSR 2014 1239 with GI fittings including cutting hole chase painted with
/ 14.13.3 primer, two coats of enamel paints etc - -
402 16.7.1 BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile
Rubber Seal & O- Ring PN 16 pressure rating for chilled
water/hot eater circulation as specified - -
ELECT. 65 nominal bore
ELECT. 80 nominal bore
ELECT. 100 nominal bore
403 16.7.3 NON - RETURN VALVE with duel plate of C I body SS plates
vulcanized NBR seal flanged end & PN 16 pressure rating for
chilled / hot water circulation including insulation as specified. - -
ELECT. 100 nominal bore
EXTERNAL WATER SUPPLY SYSTEM (NON-SCHEDULED ITEMS) - -
404 M.R. Providing & fixing schedule puddle flanges made of heavy class
M.S. pipe minimum 700 mm long, both side threading upto 50
mm dia pipe and one side threaded and other side flanged for
63dia and above sizes with epoxy coating. M.S. Plate 230 x 230
x 6 mm shall be used for pipe size upto 50 mm dia, 300 x 300 x
6 mm M.S. plate shall be used upto 80 mm dia pipe, 400 x 400 x
6 mm M.S. plate shall be used upto 250 mm dia pipe, 450 x 450
x 6 mm M.S. plate shall be used upto 350 mm dia pipe. (Length
of pipe shall be increase in some cases).
25 mm dia nominal bore Each 427.75 12.00 5,132.97
50 mm dia nominal bore Each 578.47 6.00 3,470.84
65 mm dia nominal bore Each 667.24 2.00 1,334.48
80 mm dia nominal bore Each 746.23 2.00 1,492.46
100 mm dia nominal bore Each 959.55 9.00 8,635.94
150 mm dia nominal bore Each 1,269.52 2.00 2,539.04
PUMPS ( NON SCHEDULED ITEMS) - -
405 M.R. Raw Water Treatment Feed Pump set Set 229,623.89 - -
Providing, fixing, commissioing and testing package vertical raw
water pumps, comprising of Electrical Driven inline pumping with
all accessories, Pumps shall be with C.I. Base, S.S 304,
impeller, shaft, mechanical seal, S.S. Shaft directly coupled to
motor suitable for operation on 400/440 volts, 3 phase 2900
RPM. TEFC electronic motor mounted on a common channel
baseplate 150mm dia pressure gauge, GM isolation cock and
cement concrete foundation with plaster with dunlop cushy foot
mountings with all accessories such as NRVs, valves, pressure
guage bourden type, common suction and delivery header,
bellows on sucton and delivery side complete in all repsects.
Pumps shall be suitable for 415 ± 10% volts 3 phase 50 Hz A.C
supply & shall be having the following requirement complete with
foundation and associated civil works. - -
Suction & Delivery Header - SS 304 - -
Control Valve On suction and Delivery - Ball Valve Only (No
Butterfly Valve Accepted). - -
Flow Prevention - Only Check Valve - -
Suction & delivery header including all pipes, suction & delivery
sides valves, NRV, Pressure gauges & accessories complete.
Flow Rate : 2.0 LPS (1 working + 1 stand by) - -
Min. Motor HP : 2.0 H.P. (Each) - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
406 M.R. Treated Water Transfer Pump set Set 284,733.63 1.00 284,733.63
Providing, fixing, commissioing and testing package vertical
transfer pumps, comprising of Electrical Driven inline pumping
with all accessories, Pumps shall be with C.I. Base, S.S 304,
impeller, shaft, mechanical seal, S.S. Shaft directly coupled to
motor suitable for operation on 400/440 volts, 3 phase 2900
RPM. TEFC electronic motor mounted on a common channel
baseplate 150mm dia pressure gauge, GM isolation cock and
cement concrete foundation with plaster with dunlop cushy foot
mountings with all accessories such as NRVs, valves, pressure
guage bourden type, common suction and delivery header,
bellows on sucton and delivery side complete in all repsects.
Pumps shall be suitable for 415 ± 10% volts 3 phase 50 Hz A.C
supply & shall be having the following requirement complete with
foundation and associated civil works. - -
Suction & Delivery Header - SS 304 - -
Control Valve On suction and Delivery - Ball Valve Only (No
Butterfly Valve Accepted). - -
Flow Prevention - Only Check Valve - -
Suction & delivery header including all pipes, suction & delivery
sides valves, NRV, Pressure gauges & accessories complete.
Flow Rate : 2.0 LPS (1 working + 1 stand by) - -
Min. Motor HP : 2.5 H.P. (Each) - -
407 M.R. Sump Pumps - -
Supply & Installation, testing and commissioning of centrifugal
non clogging submersible sump pumps for plant room drainage.
Pump capable capable of handling 25 mm dia soft solids. Motor
suitable for 415 + 10% volts, 3 phase, 50 Hz AC Power supply.
Pumps shall be suitable for automatic/manual operation (Overall
depth of sump – 1.5 M). Submersible sump pump shall be
provided with dry running protection. Inclusive of supporting
arrangement for stationary type. - -
Two nos. of pump installed in one sump pit 1 working & 1
standby with automatic/manual opration as requireds.
Waste Water Drainage Sump Pump (PLANT ROOM) Set 59,702.21 - -
Flow rate : 2 LPS - -
Head : 10 Mtrs. - -
Min. Motor HP : 1.0 (Each) - -
408 M.R. Supply & installation, testing & commissioning of sand filter
having FRP pressure vessel suitable for test pressure of 7 Kg. /
cm2 including valves for back-wash arrangement complete with
initial charge of media to remove the total suspended particles
from the water. - -
Capacity : 2.0 LPS - -
Working Pressure : (5 ± 2.5)MWC Set 169,921.68 - -
409 M.R. Supplying, storing, handling, installation, testing &
commissioning of Activated Carbon Filter having FRP pressure
vessel suitable for test pressure of 7 Kg./cm2 including valves
for back-wash arrangement complete with initial charge of media
to remove the total suspended particles from the water.
Capacity : 2.0 LPS - -
Working Pressure : (5 ± 2.5)MWC 179,106.64 - -
410 M.R. Supplying and fixing of PVC/HDPE/FRP tank including
electrical operated metering/dosing pump for dosing of
alum/sodium hypo-chlorite solutions in pipeline (all contacting
parts shall be of stainless steel). Capacity - 0-12 LPH
ELECTRICAL WORKS (NON SCHEDULED ITEMS) - -
411 MR CUBICAL PANEL BOARD - PLUMBING PH 217,272.95 - -
i) For 2.0 x 2.0 HP Raw water feed Pumps Set (1 Duty + 1 Stand
by) - (only isolator). - -
ii) For 2.0 x 2.5 HP Treated Water Transfer Pumps Set (H.S.) (2
Duty + 1 Stand by) - (only isolator). - -
iii) For 2 x 2.0 HP Waste Sump Pumps pump room (1 Duty + 1
Stand by) - (only isolator). - pump room - -
iv) For 1 x 3.7 HP Bore well Pump (only isolator). - -
Supply, installation, testing and commissioning of Cubical type
sectionalised floor standing switch board of 31 MVA fault
capacity at 415 V complete with 3.5 strip, 160 A capacity
Aluminium Bus - Bar Electrolytic grade, cable alley, switchgears
of following capacity & as per specifications.
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
100 A TP MCCB with heavy duty solid neutral link with (0-100A)
ammeter with 3 CT and selector switch, (0 - 500 V) voltmeter
with selector switch, phase indication light with protection fuse. -
OUTGOINGS - -
For 2 x 2.0 HP Raw Water Feed Pumps - only feeder to sub
12 A TP MCB with 10 A DOL starter, overload relay, 96 mm (0-
25A) ammeter with single CT, start / stop push buttons, on / off /
trip indication lights with protection fuse, single phase preventer. -
For 2 x 2.5 HP Treated Water Transfer Pumps (H.S) - -
12 A TP MCB with 10 A DOL starter, overload relay, 96 mm (0-
25A) ammeter with single CT, start / stop push buttons, on / off /
trip indication lights with protection fuse, single phase preventer. -
For 2 x 2.0 HP Waste Water Transfer Pumps - only feeder to
sub panels. - -
12 A TP MCB with 10 A DOL starter, overload relay, 96 mm (0-
25A) ammeter with single CT, start / stop push buttons, on / off /
trip indication lights with protection fuse, single phase preventer. -
For 2 x 3.7 HP Bore well Pumps - only feeder to sub panels.
With sub panel - -
32 A TP MCB with isolator - -
i) All the drainage pumps shall be work cyclic process i.e. in first
operation duty pump work on duty and stand by pump duty
pump work on stand by and stand by pump work as duty pump.
ii) The drainage Stand by pumps automatically work as drainage
assist pump for Duty pump when level of water rises in drainage
sump pumps i.e. Both pumps can work at a time & operation
shall be controlled with the help of level controllers and float
switches. - -
DSR'14 POWER & CONTROL CABLING (DSR 2014 SCHEDULED ITEMS) - -
412 5.30 Supplying and Earthing with GI earth plate 600mm x 600 mm x
6mm thick including accessories and providing masonary
enclosure with cover plate having locking arrangement and
watering pipe etc, with coke and salt ) as required.
413 5.11 Supplying and laying 25 mm x 5 mm. G.I. strip in 40 mm dia.
G.I. Pipe from earth electrode, as required.
414 5.15 Providing & fixing 25mm x 5mm G.I. strip on surface or in recess
for connections etc. as required.
415 5.18 Providing and Fixing 6 SWG dia G.I. wire on surface or in recess
for loop earthing alongwith existing surface/ recessed conduit/
submain wiring/ cable as required.
416 4.10 Supplying, fabricating and installing following size of perforated M.S. cable trays, including horizontal and vertical bends, reducers,- tees, cross members and other
4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness Rm 461.00 40.00 18,440.00
4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness Rm 789.00 30.00 23,670.00
417 7.7.1 Laying and fixing of One number PVC Insulated and PVC
Sheathed/XLPE power cable of 1.1 kV grade of size not
exceeding 25 sqmm on surface as required. RM 24.00 25.00 600.00
418 7.7.3 Laying and fixing of One number PVC Insulated and PVC
Sheathed/XLPE power cable of 1.1 kV grade of size exceeding
25 sqmm but not exceeding 120 sqmm on surface as required.
419 Supplying of all materials and making terminations of 1.1 KV
grade aluminium multicore cables of the following sizes. The
work includes cable glanding using brass plated double
compression glands, sizing the core leads, removing insulation,
fixing suitable crimping type copper lugs/ thimbles by using
hydraulic crimping tools with correct size of the dies, shaping the
leads and neatly connecting the same to the equipment
terminals. - -
9.1.25 3.5 Core 120 sq. mm. Armoured Aluminium cable. Nos 484.00 10.00 4,840.00
9.1.21 3.5 Core 35 sq. mm. Armoured Aluminium cable. Nos 270.00 80.00 21,600.00
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
420 Control Cabling ( PVC insulated and PVC sheathed, armoured,
Copper Conductor of 1.1 KV grade on existing cable trays).
16.0 ROAD WORK - -
421 16.1 Preparation and consolidation of sub grade with power road
roller of 8 to 12 tonne capacity after excavating earth to an
average of 22.5 cm depth, dressing to camber and consolidating
with road roller including making good the undulations etc. and
re-rolling the sub grade and disposal of surplus earth with lead
422 16.2 Extra for compaction of earth work in embankment under
optimum moisture conditions to give at least 95% of the
maximum dry density (proctor density). Cu.M 10.15 272.54 2,766.29
16.3 Supplying and stacking at site. - -
16.3.1 90 mm to 45 mm size stone aggregate. Cu.M 1,310.45 10.00 13,104.50
16.3.2 63 mm to 45 mm size stone aggregate. Cu.M 1,348.20 10.00 13,482.00
16.3.3 53 mm to 22.4 mm size stone aggregate. Cu.M 1,354.00 10.00 13,540.00
423 16.4 Laying, spreading and compacting stone aggregate of specified
sizes to WBM specifications in uniform thickness, hand picking,
rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity
in stages to proper grade and camber, applying and brooming
requisite type of screening / binding material to fill up interstices
of coarse aggregate, watering and compacting to the required
424 16.30 Providing and applying tack coat using hot straight run bitumen
of grade VG - 10 including heating the bitumen, spraying the
bitumen with mechanically operated spray unit fitted on bitumen
boiler, cleaning and preparing the existing road surface as per
specifications : - -
425 16.33 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of
stone chippings of 13.2 mm and 11.2 mm size respectively per
100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone
chippings of 13.2 mm and 11.2 mm size respectively, including a
tack coat with hot straight run bitumen, including consolidation
with road roller of 6 to 9 tonne capacity etc. complete (tack coat
to be paid for separately).
16.33.1 With paving Asphalt grade VG - 10 heated and then mixed with
solvent at the rate of 70 grams per kg of asphalt Sq.M 211.60 100.00 21,160.00
426 16.40 Providing and laying seal coat of premixed fine aggregate (
passing 2.36 mm and retained on 180 micron sieve) with
bitumen using 128 kg of bitumen of grade VG - 10 bitumen per
cum of fine aggregate and 0.60 cum of fine aggregate per 100
sqm of road surface, including rolling and finishing with road
roller all complete. Sq.M 77.10 100.00 7,710.00
427 16.47 Painting runway/taxi track/apron marking with adequate nos of
coats to give uniform finish with road marking paint of superior
make as approved by the Engineer-in-charge, i/c cleaning the
surface of all dirt, scales, oil, grease and other foreign material
etc. and lining out complete. - -
16.47.1 New work (Two or more coats) Sq.M 109.30 75.47 8,248.32
428 16.50 Providing and laying non-pressure NP2 class (light duty) R.C.C.
pipes with collars jointed with stiff mixture of cement mortar in
the proportion of 1:2 (1 cement : 2 fine sand) including testing of
joints etc. complete : Each 243.00 50.00 12,150.00
429 16.63Providing, laying and making kerb channel 30cm wide and
50mm thick with cement concrete 1:3:6 (1 cement: 3 coarse
sand:6 graded stone aggregate 20mm nominal size) over 75mm
bed of dry brick ballast 40 mm nominal size well rammed and
consolidated and grouted with fine sand including finishing the
top smooth etc. complete and as per direction of Engineer-in-
430 16.69 Providing and laying at or near ground level factory made kerb
stone of M-25 grade cement concrete in position to the required
line, level and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarse sand) including making joints with or without
grooves (thickness of joints except at sharp curve shall not to
more than 5mm), including making drainage opening wherever
required complete etc. as per direction of Engineer-in-charge
(length of finished kerb edging shall be measured for payment).
(Precast C.C. kerb stone shall be approved by Engineer-in-
HORTICULTURE & LANDSCAPING - -
431 2.2 Supplying and stacking of good earth at site including royalty
and carriage complete (by mechanical transport upto 5Km lead)
(earth measured in stacks will be reduced by 20% for payment).
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
432 2.4 Supplying and stacking at site dump manure from approved
source, including carriage complete (by mechanical transport
upto 5Km lead) (manure measured in stacks will be reduced by
8% for payment):
2.4.3 Screened through sieve of I.S. designation 4.75mm Cu.M 205.05 2.07 424.45
433 2.8 Spreading of sludge, dump manure or/and good earth in
required thickness as per direction of officer-in-charge (Cost of
sludge, dump manure or/and good earth to be paid separately).
2.9 Mixing earth and sludge or manure in the required proportion
specified or directed by the officer-in-charge. Cu.M 19.10 27.97 534.23
434.00 2.10 Grassing with selection No.1 grass including watering and
maintenance of the lawn for 30 days or more till the grass forms
a thick lawn free from weeds and filt for mowing including
supplying good earth if needed (the grass and good earth shall
be paid for separately).
435 2.12 Uprooting rank vegetation and weeds by digging the area to a
depth of 60cm, removing all weeds and other growth with roots
by forking repeatedly, breaking clods, rough dressing, flooding
with water, uprooting fresh growths after 10 to 15 days and then
fine dressing for planting new grass, including disposal of all
rubbish with all leads and lifts. 100Sq.M 3,197.25 1.73 5,531.24
436 2.14 Digging holes in ordinary soil and refilling the same with the
excavated earth mixed with manure or sludge in the ratio of 2:1
by volume (2 parts of stacked volume of earth after reduction by
20% : 1 part of stacked volume of manure after reduction by 8%)
flooding with water, dressing including removal of rubbish and
surplus earth, if any with all leads and lifts (cost of manure,
sludge or extra good earth if needed to be paid for separately):
Holes 1.2 m dia and 1.2 m deep. Each 224.95 100.00 22,495.00
Edging with bricks laid dry length wise including excavation ,
refilling, consolidating with hand packing and spreading neatly
surplus earth within a lead of 50 m: - -
2.19.1 Common burnt clay F.P.S (non modular) bricks of class
FOLIAGE AND SHADE LOVING PLANTS - -
438 3.4 Providing and display of Aglaonema Snow White hybird plant,
three in one ht. 1' & above, having 15-20 leaves bright colour,
fresh and healthy leaves, well developed in 10" P/pot.
(Specimen plant) & as per direction of the officer-in-charge. Each 220.40 25.00 5,510.00
439 3.11 Providing and display of Areca Palm plant of ht. 4'-5' having 4-5
suckers, well developed, having lush green foilage in 8" E/posts
& as per direction of the officer-in charge. Each 112.75 25.00 2,818.75
440 3.35 Providing and display of Philodendron Burgundy plant mounted
on 3' ht. moss stick, full of fresh & healthy leaves from bottom to
top, well developed in 10" E/posts & as per direction of the
officer-in charge. Each 240.90 25.00 6,022.50
441 3.52 Providing and display of syngonium golden plant mounted on 3'
ht. moss stick 3 to 4 plants in each pots, full of fresh & healthy
leaves from bottom to top in 10" E/pots & as per direction of the
officer-in charge. Each 143.50 25.00 3,587.50
HVAC SYSTEM - -
A - HI SIDE WORK - -
AIRCONDITONING SYSTEMS WITH VRV/VRF - -
Outdoor Unit & Indoor unit - -
442 MR Supply of Air Cooled Variable Refrigerant Volume/Variable
Refrigerant Flow System suitable for R410A and 415 ± 10% , 50
Hz, AC supply. The unit shall consist of indoor units and external
condensing units and other accessories as listed below
complete in all respects. The unit shall be fully charged with gas
Outdoor Unit - -
Supply of Modular type outdoor condensing units equipped with
highly efficient scroll/hermetic type DC twin rotary compressors
with invertor technology, special acryl precoated heat
exchanger,low noise condenser fan with motor, auto check
function for errors in display panel, auto address setting, as per
specifications and capacities as mentioned below.
The units shall be complete with necessary mounting frames
Capacity shall be as shown in indoor units - -
Indoor Units - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
Supply, installation, testing and commissioning of Ceiling
mounted/Ceiling concealed type, FCU Metallic of
Low/Medium/High static indoor units each complete with coil,
pre-filter, corded remote controller etc. The units casing shall be
of steel construction and 220 volt, 1 phase, 50 Hz, AC supply all
as per specifications. CFM shall be selcted as per approved
The capacities shall be as follows: - -
5 HP CASSETTE UNIT (With Panel) Each 184,198.30 - -
Balance work (Testing commissioning of above item as per boq
or any other work as required to complete the work in all respect
to handing over to NBCC / Client at their satisfaction)
4 HP CASSETTE UNIT (With Panel) Each 177,459.33 - -
Balance work (Testing commissioning of above item as per boq
or any other work as required to complete the work in all respect
to handing over to NBCC / Client at their satisfaction)
2.5 HP HIWALL UNIT Each 77,498.06 - -
2.0 HP HIWALL UNIT Each 62,896.98 1.00 62,896.98
1.25 HP HIWALL UNIT Each 48,295.89 - -
443 MR Supply of Corded Remote controller individual for operation of
each indoor units. Each 8,985.28 - -
Balance work (Testing commissioning of above item as per boq
or any other work as required to complete the work in all respect
to handing over to NBCC / Client at their satisfaction)
444 MR Supply of Imported fittings Y-joints, distributor and headers for all
Indoor units as per layout drawings. Each 15,134.59 13.00 196,749.61
Balance work (Testing commissioning of above item as per boq
or any other work as required to complete the work in all respect
to handing over to NBCC / Client at their satisfaction) Each 3,026.92 36.00 108,969.02
B - LOW SIDE WORK - -
445 MR Variable Refrigerant Volume System - -
Lifting,shifting,positioning,installation,testing of indoor
units,outdoor units, fittings (Imported Y-joints & header etc.)
remote controls of indoor units.complete as per specification and
Outdoor Unit Nos 13,477.92 - -
Indoor Units - -
Cassette Type Units Nos 5,615.80 36.00 202,168.86
HIWALL Type Units Nos 2,807.90 14.00 39,310.61
446 MR Refrigerant Piping - -
Supply,installation,testing and commissioning of Interconnecting
refrigerant pipe work with (19mm/13mm thick) closed cell
elastomeric nitrile rubber tubular insulation between each set of
indoor & outdoor units as per specifications, all piping should
be laid on Galvanised/Powder Coated tray supported by
Galvanised M S Hangers & Clamps.
9.5 mm O.D. (Outer dia) (insulation : 13 mm) 1,123.16 15.58 17,498.84
Testing and commissioning of Refigerant pipes as per boq in
proper condition of insulation. Rmt 393.11 284.42 111,807.24
6.4 mm O.D. (Outer dia) (insulation : 13 mm) Rmt 1,010.84 - -
Work already executed by the previous agency Rmt 657.05 - -
Testing and commissioning of Refigerant pipes as per boq in
proper condition of insulation. Rmt 353.80 41.15 14,558.69
447 MR Supply,installation,testing and commissioning of control cum
transmission wiring of 2 core x 1.5 sqmm copper in conduits
between indoor and outdoor units. Rmt 280.36 1,200.00 336,435.94
MR Condensate Drain Piping: - -
448 Providing, fixing and testing PVC drain piping for condensate
from unit to nearest suitable drain system as per site conditions
as per instructed at site engineer complete with all required
fittings complete with 6mm thick elastomeric nitrile rubber
insulation over pipe: - -
Balance work (Testing commissioning of above item as per boq
or any other work as required to complete the work in all respect
to handing over to NBCC / Client at their satisfaction)
449 MR MS frame work for the installation of Outdoor units Nos 2,807.90 10.00 28,079.01
LIFT & ELEVATOR - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
450 MR Providing & Installation of Lift: Passenger Lift / 13 Person /
Capacity: 1350 Kgs / Speed: 1.00 MPS / Rise:G+5 About 24.30
Meters / Stops: 6 Stops with (all opening on the same side) /
Controller Type: ACD3-MR2 / Drive: VF Regenerative (Closed
Loop) / Power Supply: 400/415 Volts (3 Phase AC) / FULL
Collective Operation / Car Group: Simplex / Machine : PM
Gearless (located Above Shaft) / Ropes Type: Flat Coated Steel
Belt / Car Finish: Stainless Steel #4(Hairline) / Ventilation: Cross
Flow Fan / False Ceiling Type: CD-41 Stainless Steel
#4(Hairline) / Car Dimensions: 1350mm W X 1600mm D X
2300mm H / Hoistway Dimensions: 1900mm W X 2500mm D /
Entrance Height: 2100mm / Car Height:2100mm / Hand Rails:
Rear as Standard Stainless Steel # 4(Hairline) Mirror Finish /
Flooring: Vinyl as standard / Door Operator: DC Door Operator,
center opening 900mm. / Cop Type: Box Type-SS Finish / Cop
Buttons: Gien Buttons in Stainless steel / Car Position Indicator:
Dot matrix (LED) scrolling Display/ Auto Fan Cut Off: Included in
Base / Hall Fixtures: 02000 Flat Type fixture / Hall Fixture Face
Place: Pan Type in Stainless Steel # 4(Hairline) / PIT Depth:
1350mm / Over Head: 4500mm / Options Required: Automatic
Rescue operation, Intercom included. - -
Group 1GeN2-Nova, MRL-1300 1mps Nos 1,764,351.49 - -
Balance work (Testing and Commissioning of above item as per
boq in proper satisfactory working condition or any other work
as required. Supplied lift make is Thyssenkrip. and handing over
to NBCC / Client at their satisfaction) Nos 352,870.30 2.00 705,740.60
451 Providing & Installation of Lift: Passenger Service Lift / 20
Person / Capacity: 1360 Kgs / Speed: 1.00 MPS / Rise:B+5
About 24.30 Meters / Stops: 6 Stops with (all opening on the
same side) / Controller Type:AC variable voltage variable
frequency ACD3-MR2 / Drive: VF Regenerative (Closed Loop) /
Power Supply: 415 Volts (3 Phase 50 Hertz AC) / FULL
Collective Operation / Car Group: Simplex / Machine : PM
Gearless (located Above Shaft) / Ropes Type: Flat Coated Steel
Belt / Car Finish: Stainless Steel #4(Hairline) / Ventilation: Cross
Flow Fan / False Ceiling Type: CD-34 Stainless Steel
#4(Hairline) / Car Dimensions: 1300mm W X 2400mm D X
2300mm H / Hoistway Dimensions: 2100mm W X 3500mm D /
Entrance Height: 2300mm / Car Height:2100mm / Hand Rails:
Rear as Standard Stainless Steel # 4(Hairline) Mirror Finish /
Flooring: Vinyl as standard / Door Operator: Automatic and
Multiray Electronic door dectator system, center opening
(1200mmW x 2100mm H). / Cop Type: Box Type-SS Finish /
Cop Buttons: Round illuminated Button / Car Position Indicator:
Dot matrix (LED) scrolling Display/ Auto Fan Cut Off: Included in
Base / Hall Fixtures: 02000 Flat Type fixture / Hall Fixture Face
Place: Pan Type in Stainless Steel # 4(Hairline) / PIT Depth:
1350mm / Over Head: 4800mm / Options Required: Automatic
Rescue operation, Intercom included. - -
Group 2GeN2-Nova MRL1mps Nos 2,840,175.57 - -
Balance work (Testing and Commissioning of above item as per
boq in proper satisfactory working condition or any other work
as required. Supplied lift make is Thyssenkrip. and handing over
to NBCC / Client at their satisfaction) Nos 710,043.89 1.00 710,043.89
Civil works - -
DSR-14 (Scheduled Item)-DSR 2014 - -
452 5.38 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for
each four floors or part thereof. Cu.M 174.20 - -
453 6.5 Extra for brick work / AAC block masonry / Tile brick masonry in
superstructure above floor V level, for each four floors or part
thereof by mechanical means. Cu.M 289.05 - -
454 6.14 Extra for half brick masonry in superstructure, above floor V level
for every four floors or part thereof by mechanical means.
455 15.2 Demolishing cement concrete manually / by mechanical means
including disposal of material within 50 metres lead as per
direction of Engineer-in - charge. - -
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
456 1.1.2 (8) Carriage of earth by Mechanical Transport including loading
,unloading and stacking within a lead of 5 km. (The rates are will
be applicable to net quantities after deduction of prescribed per-
Centage for voids mentioned in the specification under subhead
“Carriage of materials” Cum. 153.07 - -
457 1.1.2 (9) Carriage of earth by Mechanical Transport including loading
,unloading and stacking within a lead beyond 5 km. upto 10 km
(The rates are will be applicable to net quantities after deduction
of prescribed per- Centage for voids mentioned in the Cum./km
specification under subhead “Carriage of materials” . 11.54 - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
458 1.1.2 (10) Carriage of earth by Mechanical Transport including loading
,unloading and stacking within a lead beyond 10 km. upto 20 km
(The rates are will be applicable to net quantities after deduction
of prescribed per- Centage for voids mentioned in the Cum./km
specification under subhead “Carriage of materials” . 9.60 - -
459 15.7 Demolishing brick work manually/ by mechanical means
including stacking of serviceable material and disposal of
unserviceable material within 50 metres lead as per direction of
Engineer-in-charge. - -
15.7.4 In cement mortar Cum 754.10 - -
460 15.3 Demolishing R.C.C. work manually/ by mechanical means
including stacking of steel bars and disposal of unserviceable
material within 50 metres lead as per direction of Engineer - in-
charge. Cum 1,302.30 - -
461 6.47 DSR Providing and laying autoclaved aerated cement blocks masonry
2016 with 150mm/ 230mm/300 mm thick AAC blocks in super
structure above plinth level up to floor V level with RCC band at
sill level and lintel level with approved block laying polymer
modified adhesive mortar all complete as per direction of
Engineer-in-Charge. (The payment of RCC band and
reinforcement shall be made for seperately). cum 5,687.10 - -
462 22.23 DSR Providing and applying integral crystalline slurry of hydrophilic in
2016 nature for waterproofing treatment to the RCC structures like
retaining walls of the basement, water tanks, roof slabs,
podiums, reservior, sewage & water treatment plant, tunnels/
subway and bridge deck etc., prepared by mixing in the ratio of 5
: 2 (5 parts integral crystalline slurry : 2 parts water) for vertical
surfaces and 3 : 1 (3 parts integral crystalline slurry : 1
part water) for horizontal surfaces and applying the same from
negative (internal) side with the help of synthetic fiber brush.The
material shall meet the requirements as specified in ACI- 212-3R-
2010 i.e by reducing permeability of concrete by more than 90%
compared with control concrete as per DIN 1048 and resistant to
16 bar hydrostatic pressure on negative side. The crystalline
slurry shall be capable of self-healing of cracksup to a width of
0.50mm. The work shall be carried out all complete as per
specification and the direction of the engineer-in-charge. The
product performance shall carry guaranteed for 10 years against
any leakage. - -
22.23.1 For vertical surface two coats @0.70 kg per sqm per coat sqm. 468.10 - -
22.23.2 For horizontal surface one coat @1.10 kg per sqm. sqm. 362.35 - -
Electrical - -
463 DSR No.- Supply and drawing of UTP 4 pair Cat 6 LAN Cable in the
(1.53) existing surface/ Recessed steel/ PVC conduit as required. - -
1.53.1 4 Pair UTP Cat 6-1 run of cable mtr 33.00 832.00 27,456.00
1.53.1 Balance work (testing and commissioning of above item as per
boq or any other work as required and handing over to NBCC /
Client at their satisfaction) mtr 9.90 1,168.00 11,563.20
464 DSR NO - Supply & fixing Modular Blanking Plate on the exixting Modular
(1.26) Plate & switch box excluding modular plate as required. each 23.00 70.00 1,610.00
465 DSR NO - Supply & fixing following size/ Modules, GI box along with
(1.27) Modular Base & Cover Plate for Modular Switches in recess etc
as required. - -
466 9.1(DSR) Supplying and making end termination with brass compression
gland and aluminum lugs for following size of PVC insulated and
PVC sheathed/ XLPE aluminum conductor cable of 1.1 KV
grade as required. - -
SHEET METAL DUCTING - -
467 DSR Supply,Fabrication , Installation and testing of sheet metal ducts
2014/item (rectangular/round ducting complete with neoprene rubber
no.16 gaskets, elbows, splitter,vanes, hangers, supportsetc.) in
accordance with the approved shop drawings and specifications
, and shall also confirm to the BIS specifications.The duct shall
be fabricated at site for to suit pieces.
Al. Powder coated grilles - -
468 DSR Supplying, Installing, Testing and Commissioning of Al. powder
2014/item coated grilles which will make the entire system as complete and
no. 16.15 functional and prove the practical results as per the design
guidelines with all lead and lifts, all levels - Powder Coated
Extruded Aluminium Grills with End Flanges Sqm 7,107.00 7.00 49,749.00
Diffusers - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
469 DSR Supplying, Installing, Testing and Commissioning of Diffuser
2014/item which will make the entire system as complete and functional
no. 16.18 and prove the practical results as per the design guidelines with
all lead and lifts, all levels -Powder coated, extruded aluminium,
diffusers. The diffuser shall be mounted in the spill air box with
inlet connector suitable for flexible duct
Volume Control Dampers - -
470 DSR Supplying, Installing, Testing and Commissioning of Volume
2014/item Control Dampers which will make the entire system as complete
no. 16.13 and functional and prove the practical results as per the design
guidelines with all lead and lifts, all levels -Volume Control
Dampers made out of 100 x 40 x 1.55 mm thick galavanised
steel frame and blades of 1.55 mm galavanised sheet steel.
Acoustic Insulation - -
471 DSR Acoustic lining for ducting with as per the tender specification -
2014/item Internal Acoustic lining for ducting is proposed (discharge duct)
no. 16.21 with 19 mm thick Arma sound - nitrile rubber material Sqm 543.00 20.00 10,860.00
Thermal Insulation - -
472 DSR Thermal insulation of SA ducting with 25 mm thick fiberglass
2014/item (glasswool) having 24 kg/cumt. density, coat with shalikote
no. 16.23.2 primer entire outer surface of the duct, covered / coated with
factory - laminated glass - yarm reinforced Aluminium polyster
film as per approved drawing and specifications.
FIRE FIGHTING WORKS - -
473 1.2 Supply & Installation of Electrical motor hydrant pump motor &
Sprinkler pump motor. As per drawing required 2850 LPM with
474 3.2 Supply & Installation of Electrical motor hydrant pump motor &
Sprinkler pump motor. As per drawing required 180 LPM with 70
475 2.2 Supply & Installation of Diesel Engine hydrant pump motor &
Sprinkler pump motor. As per drawing required 2850 LPM with
476 5.4 Supply & Installation of MCCB Panel specification change,
require panel as per pump quantity and motor capacity. Set 372,106.00 1.00 372,106.00
477 21.3 Supply, installation testing & commissioning of Sprinkler Side
478 15.1 Supply, installation testing & commissioning double flanged 'Y'
strainers with M.S. body and SS 40-grade mesh strainer. 80 mm
479 Providing & Fixing C.I.sluice valve(with cap) complete with
bolts,nuts,rubber insertions etc.(the tail pieces if required will be
paid separately) - -
480 Providing and laying cast iron non-return valve of rating PN 1.6
dule ISI marked with flanges generally as specified complete
481 27 Supply, installation testing & commissioningof the following
GI Droping 15 mm dia
482 29 Supply, installation testing & commissioning of Rosette Plate
483 25 Supplying, installation, testing & commissioning of
sprinkler flexible pipe (UL Listed) of stainless steel
complete with 15 NPT on reducer thread with
maximum working pressure of 175 PSI test pressure of
875 PSI (Burst) with branch line (Inlet) 25mm NPT
male thread to sprinkler head (Outlet) 15mm NPT
female thread with reducer, nipple, 2 side brackets,
center bracket, stockbar of following sizes complete as
required. - -
HVAC Works - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
484 DSR Supply,Installation,Testing & Commissioning of modular type
2019/item Variable Refrigerant Flow/Variable Refrigerant Volume air
no.1 cooled Outdoor units suitable for cooling and heating, having all
hermetically sealed inverter type Scroll Compressor(s), minimum
two compressors for above 14HP modules, microprocessor
based Controller,top discharge type condensing unit(s), with
R410A Refrigerant, vibration isolators, with suitable foundation
etc.complete as required. The unit shall deliver the rated
capacity at AHRI Conditions and work even at 50°C ambient
temperature without tripping. The unit shall be suitable to work
on 400V+/-10%, 3 Phase, 50 Hz AC power supply. The unit shall
be filled with first charge of the refrigerant and ready for use as
equired. The COP at AHRI conditions shall not be less than 3.1
and IEER not less than 6.5 . - -
DSR Balance work (Installation testing and commisssioning of ODU
2019/item units supplied at site or any other work as required for handing
no.1 over to NBCC / Client at their satisfaction)
Note : Already supplied item make is LG Per HP 3,283.00 1.00 39,396.00
DSR Balance work (Installation testing and commisssioning of ODU
2019/item units supplied at site or any other work as required for handing
no.1 over to NBCC / Client at their satisfaction)
Note : Already supplied item make is LG Per HP 3,283.00 1.00 65,660.00
DSR Balance work (Installation testing and commisssioning of ODU
2019/item units supplied at site or any other work as required for handing
no.1 over to NBCC / Client at their satisfaction)
Note : Already supplied item make is LG Per HP 3,283.00 1.00 78,792.00
DSR Balance work (Installation testing and commisssioning of ODU
2019/item units supplied at site or any other work as required for handing
no.1 over to NBCC / Client at their satisfaction)
Note : Already supplied item make is LG Per HP 3,283.00 1.00 98,490.00
DSR Balance work (Installation testing and commisssioning of ODU
2019/item units supplied at site or any other work as required for handing
no.1 over to NBCC / Client at their satisfaction)
Note : Already supplied item make is LG Per HP 3,283.00 1.00 137,886.00
DSR Balance work (Installation testing and commisssioning of ODU
2019/item units supplied at site or any other work as required for handing
no.1 over to NBCC / Client at their satisfaction)
Note : Already supplied item make is LG Per HP 3,283.00 1.00 151,018.00
485 DSR Supply, installation, testing and commissioning of following
2019/item minimum capacity and external static pressure VRF/ VRV ceiling
no.4 mounted ductable type Indoor unit equipped with washable
synthetic media pre-filter, fan section withlow noise fan/
dynamically balanced blower, multispeed motor, coil section with
DX copper coil, electronic expansion valve, corded remote
control, outer cabinet, vibration isolators, drainpan, other
necessary supports etc., suitable for operationon single phase
AC supply 230V±10%, 50Hz complete as required.The unit shall
have automatic force shutdown provision in caseof fire on
receiveing signal from BMS System. The cooling capacity of
indoor unit will be at air inlet conditions of 27 Degree C DB and
19 Degree C WB temperature. - -
Low static ductable units (minium 25 pascal external static presure) - -
Balance work (Installation testing and commisssioning of IDU
units supplied at site or any other work as required for handing
over to NBCC / Client at their satisfaction)
Note : Already supplied item make is LG Nos 17,456.20 1.00 17,456.20
Balance work (Installation testing and commisssioning of IDU
units supplied at site or any other work as required for handing
over to NBCC / Client at their satisfaction)
Note : Already supplied item make is LG Nos 9,746.20 1.00 9,746.20
Refrigerant Piping - -
486 DSR Supply,installation,testing and commissioning of Interconnecting
2019/item refrigerant pipe work with (19mm/13mm thick) closed cell
no.5 elastomeric nitrile rubber tubular insulation between each set of
indoor & outdoor units as per specifications, all piping should
be laid on Galvanised/Powder Coated tray supported by
Galvanised M S Hangers & Clamps.
5.3 12.7 MM COPPER PIPE WITH 13 MM INSULATION Rmt 466.00 10.45 4,869.70
Balance work (Testing and commissioning of Refigerant pipes
as per boq in proper condition of insulation or any other work as
required for handing over to NBCC / Client at their satisfaction)
5.4 15.9 MM COPPER PIPE WITH 13 MM INSULATION Rmt 588.00 60.65 35,662.20
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
Balance work (Testing and commissioning of Refigerant pipes
as per boq in proper condition of insulation or any other work as
required for handing over to NBCC / Client at their satisfaction)
5.5 19.05 MM COPPER PIPE WITH 13 MM INSULATION Rmt 707.00 18.50 13,079.50
Balance work (Testing and commissioning of Refigerant pipes
as per boq in proper condition of insulation or any other work as
required for handing over to NBCC / Client at their satisfaction)
5.6 22.2 MM COPPER PIPE WITH 19 MM INSULATION Rmt 865.00 6.80 5,882.00
Balance work (Testing and commissioning of Refigerant pipes
as per boq in proper condition of insulation or any other work as
required for handing over to NBCC / Client at their satisfaction)
5.7 25.4 MM COPPER PIPE WITH 19 MM INSULATION Rmt 1,022.00 3.40 3,474.80
Balance work (Testing and commissioning of Refigerant pipes
as per boq in proper condition of insulation or any other work as
required for handing over to NBCC / Client at their satisfaction)
5.8 28.6 MM COPPER PIPE WITH 19 MM INSULATION Rmt 1,108.00 16.65 18,448.20
Balance work (Testing and commissioning of Refigerant pipes
as per boq in proper condition of insulation or any other work as
required for handing over to NBCC / Client at their satisfaction)
5.9 31.8 MM COPPER PIPE WITH 19 MM INSULATION Rmt 1,170.00 5.50 6,435.00
Balance work (Testing and commissioning of Refigerant pipes
as per boq in proper condition of insulation or any other work as
required for handing over to NBCC / Client at their satisfaction)
5.10 34.9 MM COPPER PIPE WITH 19 MM INSULATION Rmt 1,230.00 4.40 5,412.00
Balance work (Testing and commissioning of Refigerant pipes
as per boq in proper condition of insulation or any other work as
required for handing over to NBCC / Client at their satisfaction)
5.12 41.3 MM COPPER PIPE WITH 19 MM INSULATION Rmt 1,309.00 18.00 23,562.00
Balance work (Testing and commissioning of Refigerant pipes
as per boq in proper condition of insulation or any other work as
required for handing over to NBCC / Client at their satisfaction)
487 MR Empty boring for bored cast-in-situ reinforced cement concrete
piles of specified diameter and length shall be from working level
to the cut off level of the pile, by percussion drilling using Direct
mud circulation (DMC) or Bailer and chisel technique by tripod
and mechanical Winch Machine all complete, including removal
of excavated earth with all its lifts and leads (length shall be from
working level to the cut off level of the pile shall be measured).
MR 600 mm dia. Piles Mtr. 763.00 - -
488 MR Providing, designing & laying MS sheet piling work with ISMB-
450 mm of required depth/height an interval of 600 mm with 2
nos. MS angle iron 65X65X6 mm for making slot to receive MS
sheets by means of welding at an interval of 650 mm c/c of 650
mm & 12 mm thick MS sheet with 3 nos. Stiffner of MS angle
iron 65X65X6 mm welded with MS plate at an interval of 160
mm c/c of 6000 mm length including making hole of 50 mm dia
over top of ISMB and MS sheet strengthening ISMB and MS
sheet during pull out of the same and as per direction of EIC.
489 MR Supply and Fixing in position of 250 mm diameter (L) 700 mm
(450mm X 450mm X 6mm) Puddle plate end MS Flange with
epoxy coat required as per site. Nos. 12,090.00 - -
490 MR Supply and Fixing in position of required size 600 mm circular
C.I. manhole cover (Medium Duty) with frame as per drawing. Nos. 5,438.00 - -
491 MR Cinder Filling In the Sunken Area of Every Toilet of 1st, 2nd, 3rd,
4th & 5th Floor as Per Mentioned Reference Drawing - -
i) For Toilet Portion Cum 3,833.00 - -
ii) For Sunken Balcony Portion Cum 3,833.00 - -
492 MR Core cutting the required dia, size with using the DD200 heavy
duty machine for various services crossing in floor slab as per
the site requirement for the following - -
i) Dia 125 mm and depth upto 200 mm Nos. 3,631.00 - -
ii) Dia 125 mm and depth upto 300 mm Nos. 3,907.00 - -
iii) Dia 250mm and depth upto 200 mm Nos. 3,981.00 - -
MR Tiles - -
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
493 i Providing and laying vitrified paver floor tiles of sizes
600X600mm and thickness of 20mm with water absorption less
than 0.08% and conforming to IS : 4457, of approved make, in
all colours and shades, laid on 20 mm thick cement mortar 1:4
(1 cement : 4 coarse sand), including grouting the joints with
white cement and matching pigments etc., complete. (Make:
Johnson - KORNETO IVORY)
Work already executed by the previous agency
Balance work (Tiles available at site, balance work is to repair,
laying as per specs or any other work as required for handing
over to NBCC / Client at their satisfaction) sqm 915.90 1,528.59 1,400,036.27
494 ii Providing and fixing 10 mm thick acid and / or alkali resistant
tiles of Johnson make (GMALO - 10mm thick) using acid and /
or alkali resisting mortar bedding, and joints filled with acid and /
or alkali resisting cement as per IS : 4457, complete as per the
direction of Engineer-in-Charge.
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof
cement : 4 coarse sand)
Acid and alkali resistant tile (Size of Tile 600x600 mm)
Work already executed by the previous agency
Balance work (Tiles available at site, balance work is to repair,
laying as per specs or any other work as required for handing
over to NBCC / Client at their satisfaction) sqm 554.70 27.97 15,513.85
495 iii) Providing and fixing 10 mm thick acid and / or alkali resistant
tiles of Johnson make (SANDEX GREY - 10mm thick) using
acid and / or alkali resisting mortar bedding, and joints filled with
acid and / or alkali resisting cement as per IS : 4457, complete
as per the direction of Engineer-in-Charge.
In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement
: 4 coarse sand)
Acid and alkali resistant tile (Size of Tile 600x600 mm)
Work already executed by the previous agency
Balance work (Tiles available at site, balance work is to repair,
laying as per specs or any other work as required for handing
over to NBCC / Client at their satisfaction) sqm 475.80 42.84 20,383.27
ELECTRICAL WORK - -
496 MR Supplying and fixing following Data Outlet on the existing
modular plate ncluding connections . nos 393.00 62.00 24,366.00
497 MR Supplying and fixing POP UP box (for Floor Plug Point) with box
cover 6/16 A switch & Socket. nos 2,928.00 38.00 111,264.00
498 MR Supplying and fixing following 25 A AC starter on the existing
modular plate ncluding connections . nos 468.00 11.00 5,148.00
499 MR Supply, installation, testing & commissioning of 6 KV/433 V ,
500 KVA Outdoor type Commpact sub-station with SF6
insulated RMU (3 WAY) HT Metering, Dry type Cast Resin
Transformer & ACB as per Technical particulars and BOQ. set 2,344,703.00 - -
Balance work (Lifting,Testing and commissioning as per boq in
proper condition of insulation or any other work as required for
handing over to NBCC / Client at their satisfaction)
500 MR Supply, installation, Testing and commissioning of the following
UPS SYSTEM as per specifications and complete in all
30 KVA(3:3)High Performance IGBT/PWM based True-On-Line
Double Conversion with DSP controlled UPS system with static
By Pass and Maintenance By Pass Switch with Connected load
with inbuilt Isolation Transformer.
12V-65Ah SMF Batteries-40 Nos for 30-35mins of Backup of
Full Load with Battery Rack, Interlink Cables (DC Cables & AC
COVENTIONAL LIGHTING ARRESTER - -
501 MR Supply& installation of single spike air terminals of 10 mmdia.
lengths as required and as per site conditions.The air terminal
shall be manufactured with aluminum. The terminal shall be
provided with the integrated/attached base support suitable for
Mounting the terminals as per site condition.The base support
shall be minimum 3 mm thick and shall have in built connect or
fitting for connectiono flightning conductor in such away that
conductor contact are as hall not be less than 40mm on all side
of the conductor.
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
502 MR Roof Conductor for Parapet: Supply & installation of 8mm dia
aluminum round conductor for air termination network at parapet
503 MR Roof Conductor for Air Termination and for Making Mesh:
Supply & installation of 8mm dia aluminum round conductor for
making mesh & air termination network at terrace levels, to be
installed on wall/parapet,with suitable type of clamps, hardware
etc.as required.
504 MR Supply & installation of roof / mesh Conductor holder for holding
of 8mm round conductor.The minimum height of the conductor
should be 85mm PVC clear height between roof and conductor
and installate very 1mtr. Nos. 281.00 300.00 84,300.00
505 MR Supply & installation of Straight -Connect or for making straight
joint of 8mm aluminum Conductor to 8mm dia aluminum
conductor on parapet wall, roof and vertical façade of
mesonery/glass/metalic work. Nos. 441.00 12.00 5,292.00
506 MR Supply & installationof T-Connector for making Tee joint of
8mm aluminium Conductor to 8 mm dia aluminium conductor on
parapet wall, roof and vertical façade of mesonery
/glass/metalicwork.
507 MR Supply & installation of X-Connector for making Cross joint of
8mm aluminium Conductor to 8 mm dia aluminium conductor on
parapet wall,roof and vertical façade of mesonery
/glass/metalicwork.
DownConductor: - -
508 MR Supply & installation of 8mm dia aluminium round conductor for
Down conductors to be installed on vertical façade of
mesonery/glass/metalicwork.
509 MR Supply & installation of wall Conductor holder for holding of 8mm
round conductor.The min height of the PVC conductor holder
should be 85mm clear height between roof and conductor and
install at every 1mtr. Nos. 281.00 200.00 56,200.00
510 MR Supply & installation of Test Clamp to disconnect the down
conductor from the earth termination network for regular checks
of the earth termination resistance value.
511 MR Supply & installation of Expansion piece of made of 8mm
aluminium at every 20mtr to maintain the flexibility to the
conductor due to heat. Nos. 467.00 30.00 14,010.00
512 MR Lightning Strike counter Model: JMV 6D for counting the number
of lightning strikes without any power supply.The Counter should
be mounted on the Down Conductor.The Lightning Counter
should be IP65 rated enclosure suitable for external application.
EarthTerminationNetwork: - -
513 MR Supply & installation of Earthing termination made of copper-
bonded rod of 10 feet length,14 mmdia.(Minimumcopper
bonding shallbe0.25mm)alongwithRod-to-Conductor
connectors,Earthenhancement material,PitCover
andotheraccessoriesas required
andasperspecificationandotherapplicablecodes.
514 MR Supply & fixing of 25 X 6 mm GI Strip laid at 600mm below the
ground, as Required and as per specification and code of
MR Surge ProtectionDevice: - -
515 MR Supply & installation of ClassB/Type I Single Phase Surge
Protection Devices as per IEC
62305-4 and tested according to IEC61643 –11,DIN Rail
Maximum Continuous Operating Voltage of 320V and Voltage
Protection Level of
1.3kV (L-N).Response Time should be less than 100ns(L-N&N-
PE). The maximumim pulse test current should be 65kA(10/350
µs) per pole and 100kA (10/350 µs) neutral to protective
earth.The surge protection devices shall be enclosed in
polycarbonate enclosure of IP65 rating.
Sl. No. Ref. Name of Estimate Unit Rate Quantity for BOQ Amount for BOQ
516 MR Supply & installation of ClassC/Type II Single Phase Surge
Protection Devices as per IEC
62305-4 and tested according to IEC 61643 –11,DIN Rail
Maximum Continuous Operating Voltage of 320V and Voltage
Protection Level of
1.3kV (L-N).Response Time should be less than 25 ns per pole
100ns between neutral to protective earth.The maximumim
pulse discharge surge current should be40kA(8/20µs) per pole
and 60kA(8/20µs) neutral to protective earth.The surge
protection devices shall be enclosed in polycarbonate enclosure
517 MR Supply, Installation, Testing and commissioning of CAT6A UTP
(unshielded twisted pair) cable 23 AWG copper conductors.
HVAC WORKS - -
518 MR Supply of Remote controller individual for operation of each
indoor units. Each 3,158.00 - -
Balance work (Testing and commissioning as per boq in proper
condition or any other work as required for handing over to
NBCC / Client at their satisfaction) Each 631.60 49.00 30,948.40
519 MR Supply, installation, testing and commissioning of Inline fan of
static pressure of 19 mm wc starter and louvers at outlet. The
units shall operate at 220 volt, 1 phase, 50 Hz, AC supply. - -
520 MR Supply, installation, testing and commissioning of inverter type
split AC of following capacity. The units shall operate at 220
volt, 1 phase, 50 Hz, AC supply. - -
521 MR Supply, installation, testing and commissioning of dehumidifier of
appropriate capacity. The units shall operate at 220 volt, 1
phase, 50 Hz, AC supply. - -
COLLAR DAMPER - -
522 MR Supplying, Installing, Testing and Commissioning of Collar
dampers which will make the entire system as complete and
functional and prove the practical results as per the design with
all lead and lifts, all levels -Collar Damper of opposed blade type
made out of Aluminium alloy extrusion with
anodised matt black finish
Condensate Drain Piping: - -
523 MR Providing, fixing and testing PVC drain piping for condensate
from unit to nearest suitable drain system as per site conditions
as per instructed at site engineer complete with all required
fittings complete with 6mm thick elastomeric nitrile rubber
insulation over pipe: - -
524 MR Supply , filling/charging of extra Refrigerant R410A Gas with
appropriate method as per site condition and requirement. - -
R410A Refrigerant Kgs 1,739.00 95.00 165,205.00
FIRE FIGHTING WORKS - -
525 MR Supply, installation testing & commissioning of Fire
Extinghusher 4.5 kgs CO2. Set 7,092.00 12.00 85,104.00
526 MR Supplying of all materials and making terminations of 1.1 KV
grade aluminium multicore cables of the following sizes. The
work includes cable glanding using brass plated double
compression glands, sizing the core leads, removing insulation,
fixing suitable crimping type copper lugs/ thimbles by using
hydraulic crimping tools with correct size of the dies, shaping the
leads and neatly connecting the same to the equipment
terminals. - -
3.5 Core 70 sq. mm. Armoured Aluminium cable. Mtr 656.00 75.00 49,200.00
527 MR Control Cabling (PVC insulated and PVC sheathed, armoured,
Copper Conductor of 1.1 KV grade on existing cable trays).
Total BOQ Amount = 39,532,099.15
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
01NITITTLalitKalaAkademi.pdf
Tender Document
02GCC2016inclAmendment01to02.pdf
Tender Document
CS_cover_2_Quotingsheet.xlsx
Tender Document
03ApprovedmakeList.pdf
Tender Document
04TenderDrawings.pdf
Tender Document
05BOQLKA.pdf
Tender Document
corrigendum-228-CORRIGENDUM01.pdf
pdf • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .