Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹24.0 L+₹53,442.80 (2.28%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹24.0 L+₹55,365.50 (2.36%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹24.1 L+₹61,213 (2.61%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹24.2 L+₹69,283.65 (2.95%)Rejected-AOC | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹22.3 L
EMD Value
₹44,660
Closing Date
19 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
SPL REPAIR TO BLDG NO TP-87 MT LINE AT PEDONG UNDER GE 867 EWS
2022_MES_560379_1
GE/867/TOKEN/24 OF 2022-2023
Open Tender
Civil Works
Item Wise
180 days
KALIMPONG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹44,660
17 Dec 2022
29 Oct 2022
22 Nov 2022
29 Oct 2022
19 Nov 2022
12 Nov 2022
29 Oct 2022 - 8 Nov 2022
Amount
Dismantling of plain or corrugated steel sheeting any gauge and thickness including Nanital or similar pattern roof covering complete all as specified.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.4mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Preparation of old painted steel and iron surfaces of any description and in any position over 10 cm width or girth as in roof not other wise specially described and applying one coat of Ist grade enamel paint over a coate of red oxide primer zinc chrome complete all as specified and directed.
Preparation of new painted steel and iron surfaces of any description and in any position over 10 cm width or girth as in roof not other wise specially described and applying one coat of Ist grade enamel paint over a coate of red oxide primer zinc chrome complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not other wise specifically provided for.
S&F roof trusses, framed trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (Beam, tee, angle channel or flat section) incl distance pieces, cleats, nut and bolts conforming to FE-410w (grade 250-E quality A) complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets.
S&F for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall and screws at 450 mm centre/intermediate channel 0.9mm th having two equal flanges of 15mm each and web of 450 mm suspended from soffit at approx 900mm centre to centre with GI cleats and steel steel expansion fasteners with and incl ceiling section (n.exc 1.2 mtr length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each eith lips of 10.5 mm fixed to intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre size of grid 605 x 605 mm incl using of 0.9 mm MS wires as hangers complete all as specified and directed by Engineer-in-Charge.
S&F PVC insulation panels with EPS stuck 1mm printed sheet and thickness of PVC insulation panel is 10mm sutibley placed in false ceilin grid made of aluminum/GI/MS/Wooden all as specified and directed at site by Engineer-in-Charge.
Dismantling of timber in scantling 40 sqcm and over in section in any position in unframed work.
M & L clean sawn 2nd class hard wood in scantling,clean sawn,fixed as scantiling complete all as specified and directed by Engineer-in-Charge.
M & L preparing surfaces of wood & wood based materials new or old of any description & girth not other wise described & treated with two coats of creosote oil.
Demolition of brick/ concrete block/ stone boulder masonery walling built in Cement mortar of any description complete all as specified and directed by Engineer-in-Charge.
M & L precast cement concrete type C-1 , (1:3:6) (using 20mm graded stone aggt) block masonry with solid blocks exc 10cm in width and setting in CM (1:6) complete all as specified and directed.
Taking down cement plaster of any description from stone walls incl raking out joints hacking for key, scrubing down with water etc.
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:6) on internel wall complete all as specified and directed.
M & L 15mm thick rendering on fair faces of brick work concrete surface in CM (1:4) on externel wall with water proofing compound. Note : WPC will be measured and paid separately.
Supply only integral water proofing compound.
M&L for newly plastered surfaces of walls and applying two coat of oil bound distemper all as specified and as directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed
Taking down chowkats frames but with shutters (with out taking off shutter from the frames) exc 1.5 sqm but not exc 4.00 sqm each complete all as specified and directed..
Taking down chowkats frames but with shutters (with out taking off shutter from the frames) n.exc 1.5 sqm each complete all as specified and directed..
S&F steel window (with fly froof) with side hung shutter, incl projecting type hinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or welded
S & F 3.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane complete all as specified and directed..
S&F Pressed steel frames of size 125x60 mm for door with one or more rebates including necessary fixing lugs, hings, lock strike plate etc., complete as specified
S & F 30mm thick flush door shutters , solid core construction with black board core and plywood face panels,commercial type on both face complete all s specifiedhard & fitted to chowkats complete all as specified and directed..
S&F 200mm size aluminium anodised barrel tower bolts of extruded sections.
S & F 150mm size aluminium handle cast type anodised.
S & F 250 mm long aluminium alloy, anodised sliding door bolt with hasp and staple (bolt type ) and fixing clip of sheet cost or extruded section or cost aluminium alloy & fixed complete all as specified and directed..
M&L prepration of newly wooden surfaces of any description & applying two coats of synthetic enamel paints over one coat of pink primer incl prepration of surfaces complete all as specified and directed..
Preparation of new painted steel and iron surfaces of any description and in any position over 10 cm width or girth as in roof not other wise specially described and applying one coat of Ist grade enamel paint over a coate of red oxide primer zinc chrome complete all as specified and directed.
Demolition of cement concrete(Unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level).
M & L 75mm thick PCC (1:3:6) type C-2 (40mm graded stone aggt) in plinth protection laid to slope of 1 in 12 and finishing cement concrete suraface even and smooth without using extea cement with and including all necessary form work to divide the area in panel, finishing exposed edges fair or rounding or chamfered of exposed edges and providing 6mm thick joints therough the thickness of plinth protection duly filled mastic filling of one part of hot bitumen 85/25 grade and three part of fine sand complete all as specified and directed by Engineer-in-charge.
Forming construction joint (dummy) joints 65mm deepx 10mm wide filled with sealing compound grade A
M&L 40 mm thick Plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floors finished even and smooth using extra cement all as specified.
Dismantling floor hearth or wall tiling including cement morter bedding (but not backing) removing serviceable tiles to store & rubbish of the premises.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/Rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed with coloured cement to match over and incl 15mm thick screed bed in cm (1:6) in flooring complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to IS-13712, grade B-II(a) (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm on vertical surfaces such as dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 10 mm thick backing coat in cement mortar (1:3) complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 75 mm thick as in sub base to floors
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for reinfored cement concrete (nominal mix) in (1:2:4) type B1 (using 20mm graded aggregate) as in beams, lintels over 1.5m span complete all as specified and directed.
M&L for reinfored cement concrete (nominal mix) in (1:2:4) type B1 (using 20mm graded aggregate) as in slabs supported on walls, beams and shelves and the like complete all as specified and directed.
Formwork to sides and soffits of lintels, shelves including suppotrts, beams etc in rough finished and flat surfaces of concrete complete all as specified and directed.
M&L for mild steel deformed TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally etc and binding with M.S. wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No.46 but 5mm dia & over upto and incl 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
S&F in repairs 20mm dia curtain rails, mild steel, chromium plated with incl fixing brackets, stops, rollers etc.
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for LT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge.
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
M&L for sand cushioning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Puned layers shall be measured.
Supply and laying reinforced precast concrete cable cover, class LV, type 1, flat, size 250mmx150mmx40mm complete.
Supply and Laying service cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core as required at site.
M & L GI tube light grade for passing through cables under the floor ,along the wall or along the pole of 25 mm bore and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc complete all as specified and as ditected.
Taking down copper/aluminium point wiring (light, fan, socket or power ) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, light fitting etc and making good disturbed surfaces of wall, floors, etc all as specified and as directed by the Engineer – in - Charge.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing capping with all necessary fittings for light/fan/bell point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc. complete all as specified or directed including testing on completion.
All as per item No 59 here – in – before but for one 3 / 5 -pin switch socket outlet 5 amps on independent board.
All as per item No 59 here – in – before but for one 3 / 5 -pin switch socket outlet 5 amps on same board.
M&L for one 3 pin socket, outlet,15 amps, independent with cables 4 sq mm size all as specified and as directed.
Supply and fix switch socket combination 2 – in – one, 5 amps flush type all as specified and as directed. Make : Anchor/Havells/Plaza
Supply and fix switch socket combination 3 Pin 16A, flush type all as specified and as directed. Make : Anchor/Havells/Plaza
Supply and fix switch piano flush button, single pole, 5 amps, one way all as specified and as directed. Make : Anchor/Havells/Plaza
Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal all as specified and as directed.Make : Anchor/Havells/Plaza
S & F Energy efficient LED tube light fitting 4", 1x18 watt, with bipin holders, connector block, CCT - 6500K, system output lumen not less than 1800lm, aluminium housing, surge protection range 3KV including connecting up with PVC insulated 3 core sheathed 0.5 sqmm copper conductor two numbers PVC mounting blocks for fixing of fitting complete all as specified and as directed by Engineer-in-charge. Make: Philips/Crompton/Havells.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and as directed. Make: Philips/Crompton/Havells.
Supply and fixing lamp holder insulated body with back plate for batten fitting all as specified and directed.Make : Anchor/Havells/Plaza
S & F in LED lamp B-22 10 W poly carbonate body 3 Star.(Cat part No LED ADORE 10W B22 CDL 3 STAR of Havells or equivalent in Philips/Crompton.
Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral (SPN) linkof 12 way 240 Volts AC,concealed in wall including connection with copper thimbles as required complete all as specified. Make- Legrand /Siemens / Schneider.
Supply and fix MCB, Single Pole & Neutral (SPN), 32/40 Amps, 240V, 10KA 'C' curve, 50 Hz, complete all as specified and directed by Engr-in-Charge including taking down old unserviceable MCB. Make- Legrand, Siemens, Schneider.
Supply and fix MCB single pole (SP), 10 kA of 5 Amps to 32 Amps capacity 240 Volts. conforming to IS/IEC 60898-1 2002, integrated label holder, Sliding bottom clamp, IP 20 protection all as specified and directed by Engr-in-Charge including taking down old unserviceable MCB. Make- Legrand, Siemens, Schneider.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1:3:6) type C-1 , 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed.
MS BRAHMA CONSTRUCTION
MANOJ JINDAL
RAJU TAMANG
PRASAD PRADHAN AND SON
M/S G. K. SUTHAR
Sri Gupta Construction
MS MAYA PRAKASH GOEL AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .