Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.3 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder for the subject work. | |
| 2 | L-2₹21.1 L+₹42,746 (2.07%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L-2 | Rejected-Finance other than the lowest bidder | |
| 3 | L-3₹23.6 L+₹2.9 L (14.0%)Rejected-Finance | L-3 | Rejected-Finance other than the lowest bidder |
| Sl No | Description | Qty | Unit | M/S JAINENDRA KUMAR JAIN L2 | M/s VIKAS TRADERS L3 | SUNIL KUMAR KORPAL L1 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work built in cement mortar of any description incl quions arches but excluding aslars facing complete all as specified and as directed. | 2.5 | Cum | 200 ₹500 | 100 ₹250 Lowest | 100 ₹250 Lowest |
| 2.00 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc. 6 mtr mean radius built in CM(1:6) complete all as specified and directed. | 1.35 | Cum | 5,000 ₹6,750 | 6,000 ₹8,100 | 4,000 ₹5,400 Lowest |
| 3.00 | M&L for brick work with sub class B bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. | 10 | Sqm | 500 ₹5,000 | 200 ₹2,000 Lowest | 600 ₹6,000 |
| 4.00 | Taking down plaster on brick or concrete surfaces including raking out joints for key and srubbing down with water etc complete all as specified . | 653 | Sqm | 5 ₹3,265 Lowest | 100 ₹65,300 | 5 ₹3,265 Lowest |
| 5.00 | M&L for rendering 15 mm thick on fair faces of brick or concrete the surface even and smooth without using extra cement in CM (1:4) Mixed with water proofing compound @ 3% complete all as specified and directed.
Note :Water proofing compound shall be measured and paid separatel. | 313 | Sqm | 120 ₹37,560 Lowest | 220 ₹68,860 | 140 ₹43,820 |
| 6.00 | Supply only integral water proofing compound complete all as specified and directed. | 100 | Kg | 70 ₹7,000 | 60 ₹6,000 | 30 ₹3,000 Lowest |
| 7.00 | M&L for rendering 15 mm thick on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement. in CM (1:6) complete all as specified and directed. | 230 | Sqm | 110 ₹25,300 Lowest | 200 ₹46,000 | 130 ₹29,900 |
| 8.00 | M&L for 5mm rendering thick in CM (1:3) on concrete sufaces, finished even & smooth (without using extra cement), complete all as specified and directed. | 150 | Sqm | 130 ₹19,500 | 150 ₹22,500 | 50 ₹7,500 Lowest |
| 9.00 | M&L for sunken floor treatment as in following precedence
(i) The treatment of existing sunken floor is to be dismantled upto full depth of Sunken RCC Slab and the surfaces both vertical and horizontal shall be cleaned by removing all loose mortar, dirt, dust etc. by chisel, hammer, wire brush/Jute Brush and Air Blower machine than apply two coats of elastomeric compound viz back bond WPC-30 over one coat on neat primer i.e. Super latex be applied on clean surface.
(ii) Provide 40mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in sub base and provide 40mm dia GI pipe med gde as in (spout) of 600mm long as in sunken portion.
(iii) Then rendering 15mm thick in CM 1:3 using liquid water proofing compound @ rate 200 ml per 50 Kg bag of cement on horizontal and vertical surfaces of sunken portion. Note: Water proofing compound shall be measured and paid separately. (iv) The sunken floor tested for leakage/seepage by ponding it with water for minimum 72 hrs.
(v) Then fill the remaining sunken portion with PCC 1:5:10 using brick aggregates including fixing sanitary items requiring embedding in cement concrete.
To ensure that there shall not be any seepage/dampness in the slab as seen underneath and side. | 4.5 | Sqm | 2,400 ₹10,800 | 1,000 ₹4,500 | 700 ₹3,150 Lowest |
| 10.00 | Dismantling unserviceable PVC water storage tank of 500 Ltr capacity, complete all as specified and directed. | 8 | Each | 50 ₹400 | 200 ₹1,600 | 20 ₹160 Lowest |
Tender Value
₹29.1 L
EMD Value
₹58,160
Closing Date
27 Dec 2025, 6:00 pmClosed
Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
SPECIAL REPAIR TO BLDG NO PG-15 (08 X QTRS) ORS MD ACCN AT DHANA MIL STN UNDER AGE (I) DHANA
2025_MES_743538_1
84131/E8
Open Tender
Civil Works
Item Rate
180 days
Dhana
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
AGE (I) Dhana
₹58,160
Yes
20 Jan 2026
8 Dec 2025
29 Dec 2025
8 Dec 2025
27 Dec 2025
22 Dec 2025
8 Dec 2025 - 22 Dec 2025
Amount
Demolition of brick work built in cement mortar of any description incl quions arches but excluding aslars facing complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc. 6 mtr mean radius built in CM(1:6) complete all as specified and directed.
M&L for brick work with sub class B bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Taking down plaster on brick or concrete surfaces including raking out joints for key and srubbing down with water etc complete all as specified .
M&L for rendering 15 mm thick on fair faces of brick or concrete the surface even and smooth without using extra cement in CM (1:4) Mixed with water proofing compound @ 3% complete all as specified and directed. Note :Water proofing compound shall be measured and paid separatel.
Supply only integral water proofing compound complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement. in CM (1:6) complete all as specified and directed.
M&L for 5mm rendering thick in CM (1:3) on concrete sufaces, finished even & smooth (without using extra cement), complete all as specified and directed.
M&L for sunken floor treatment as in following precedence (i) The treatment of existing sunken floor is to be dismantled upto full depth of Sunken RCC Slab and the surfaces both vertical and horizontal shall be cleaned by removing all loose mortar, dirt, dust etc. by chisel, hammer, wire brush/Jute Brush and Air Blower machine than apply two coats of elastomeric compound viz back bond WPC-30 over one coat on neat primer i.e. Super latex be applied on clean surface. (ii) Provide 40mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in sub base and provide 40mm dia GI pipe med gde as in (spout) of 600mm long as in sunken portion. (iii) Then rendering 15mm thick in CM 1:3 using liquid water proofing compound @ rate 200 ml per 50 Kg bag of cement on horizontal and vertical surfaces of sunken portion. Note: Water proofing compound shall be measured and paid separately. (iv) The sunken floor tested for leakage/seepage by ponding it with water for minimum 72 hrs. (v) Then fill the remaining sunken portion with PCC 1:5:10 using brick aggregates including fixing sanitary items requiring embedding in cement concrete. To ensure that there shall not be any seepage/dampness in the slab as seen underneath and side.
Dismantling unserviceable PVC water storage tank of 500 Ltr capacity, complete all as specified and directed.
Supply and fixing 500 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with all as specified in SSR Part I complete all as specified and directed.
S&F in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for ironpipe and fixed. (Minimum weight 210 gms) complete screwed for iron pipe or brass ferrule of size 20 mm bore.
S&F Vitreous china water closet Orissa pattern long pan size 580x440mm with trap front or back inlet and integral foot rest complete fixed in repair including lime concrete bedding and connection to drain or outgoing pipe and to flushing pipe and anti siphon pipe complete all as specified and as directed.
S & F in repair brass chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges, complete all as specified and directed.
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specfied and directed.
S & F in repair Bib taps cast copper chromium plated fancy type with crutch or butterfly handle screwed for iron pipe or for brass ferrule of 15 mm bore dia complete all as specified and directed.
S & F in repairs Fancy type chromium plated with long shank and cup (Concealed type) 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S & F repair in 10 ltr low level PVC value less, syphonic action type flushing cistern,white, with ball value, float and handle including brackets all as specified and directed.
S & Fixed in repairs Angle stop valve cast copper alloy, with fancy type chromium plated capstan head, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unions and fixed complete, all as specified.
S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union
M & L for mechine cut kota stone slab flooring 20-25 mm thickover cement screed 20mm thick base laid in CM 1:6 and jointed with white cement slurry with pigment including cutting and polishing.
M & L for mechine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed/backing coat in CM 1:4 and jointed with white cement slurry with pigment including cutting and polishing.
Demolition of cement concrete in ground floors and pavings n.exc. 15cm thick above or below ground level complete all as specified and directed.
M & L for 25 mm thick PCC 1:2:4, typeB-O, using 12.5mm graded stone aggregate finished fair and even etc complete all as specified
M&L for 75mm thick cement concrete (1:3:6) type C-2 using 40mm graded stone agg finished even & smooth without using extra cement as in plinth protection, complete all as specified and directed.
M & L for 3 mm thick Glass dividing strips forming joint to full depth at every 3.0m interval and at every charge of direction and filled mixture in plinth Protection complete all as specified and directed.
M/L for 75 mm thick Cement concrete type C1, 1:3:6 (using 20 mm graded granite stone aggregate) in sub base of flooring/ hard standing finishing the surface even and smooth without using extra cement
M&L for Non-skid ceramic colour tiles7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
M&L for Non-skid ceramic colour tiles7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in dado/skerting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 10 mm thick backing coat in cement sand mortar 1:4 complete all as specified and as directed.
M&L Non skid ceramic coloured tiles 7mm to 8mm (square/rectangular) area each tiles exc. 0.11sqm but not exc. 0.18 sqm in floors thick in floor etc set & jointed in neat cement slurry and pointed in white cement and pigment over 15mm screed bed or beading layer in CM 1:4 complete all as specified and as directed.
M&L Glazed ceramic colour tiles of size 300 x 450 x7mm thick in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete as specified and directed.
M&L for Granite (of any type) tiles 20mm thick machine cut, in , bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed.
Rounding to edges of stone slabs one edge such as in steps cooking platform and other similer shine complete all as specified and as directed.
Demolition of PCC as in roof pedding(Incl APP membrane, plaster) (other than ground floors), beams, staircases, landing,chajjas and similar suspended workcomplete all as specified and directed.
M & L for 50 mm thick cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair to receive APP membrine complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid for separately.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound@ 3% cement and finished even and smooth without using extra cement. Note:- Water proofing compound shall be measured and paid for separately.
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and applying APP membrane HMHDPE 3 Kg plain (thickness 3 mm) (total weight of the finished membrane not less than 3.0 kg/ sqm ± 5 % per sqm) confirming to IS 16540: 2017 of following operation complete all as specified and directed:- (a) Applying a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25⁰C, 0.87-0.89 kg/ litre and viscosity 70-160 cps, laying over the primer coat using Butane Torch and sealing all joints, overlapping etc. as per Annex D of IS 16540: 2017 (b) Applying hot blown grade bituminen 85/25 @ 1.20 Kg/Sqm over primer. (c) Laying of polymeric water proofing membrane of weight not less than 3 kg/Sqm
M & L for cutting grooves or chase in brick wall, 75 mm wide and 65 mm deep and including filling with cement mortar 1:4 mixed with water proofing as mentioned in Annex D of IS 16532: 2017, IS 16540: 2017 compound complete all as specified and as directed.
M&L for two coat of aluminium paint at the rate of 100 gm/ Sqm as per manufacturer instruction over bituminous layer complete all as specified and directed.
Taking down chowket or frame exc 1.50 sqm but n. exc. 4.00 sqm with shutters (wihtout taking of shutter from frame ) etc complete all as specified.
Taking down chowket or frame n.exc 1.50 sqm with shutters (wihtout taking of shutter from frame ) etc complete all as specified and directed.
Taking down shutters of any description exceeding 1 sq.m and not exceeding 2 sqm each complete all as specified and directed.
M&L for Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., complete, as specified, supplied and fixed (125x60mm) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for fixing hold fast, coping, cills and filling in pressed steel door frames including necessary form work and finishing the surfaces to match with existing, complete all as specified and directed.
M & L for 2 nd class hard wood factory made 35mm thick plain framed pannelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
M/L for 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.complete all as specified and directed.
S & F for 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
Supply and fixing 150mm size Extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed.
S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed.
S & F for 300mm mild steel , ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and as directed.
Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified.
S & F Steel windows with side hung shutters, Guard bars (Double shutter glazing and mesh) including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded.Glass and mesh measured and paid separtely complete all as specified and directed.
S & F for factory solid PVC door frame of size 50mm x 47 mm made out of 5mm wood grain printed PVC sheet reinforced with MS Square tube as per specified & drawing in opening complete all as specified and directed.
S & F for Factory Made Solid PVC Moulded Door Shutter, 28 to 30 mm thick (stiles),with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm Plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face complete all as specified and directed.
S&F for MS butt hinges of 100 mm size cold rolled mild steel medium weight, ISI marked complete all as specified and directed.
Supply & fixing Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane & glazing with wooden/ aluminium bead/oil putty in Square n.exc 0.5 Sqm in Each panel 3 mm thick complete all as per specified and directed.
Supply & fixing Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane & glazing with wooden/ aluminium bead/oil putty in Square n.exc 0.5 Sqm in Each panel 3 mm thick complete all as per specified and directed.
S & F Galvanized mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples wooden bead complete all as specified and directed.
Preparation of new wooden surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
Preparation of old wooden surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
Preparation of old steel surfaces of any description, over 10cm width or girth and applying one coats of synthetic enamel paint, complete, all as specified and as directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome , complete, all as specified and as directed.
S & F in repairs 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs.
M & L for PVC (SWR) multi floor trap diameter of outlet 75 mm with grating including jointing with solvent cement.
S&F PVC (SWR) pipes single socketed in any length with rubbering joints fixed to walls 110mm bore.
S&F PVC (SWR) pipes single socketed in any length with rubbering joints fixed to walls 75 mm bore.
S&F PVC (SWR) bends any radius 110mm bore with access door.
S&F PVC (SWR) bends any radius 75 mm bore with access door.
PVC(SWR) junction single (single 'T') equal or unequal 110mm bore with access to door ccomplete all as specified and directed.
PVC(SWR) junction single (single 'T') equal or unequal 75 mm bore with access to door ccomplete all as specified and directed.
S&F in repair stainless steel sink 1.00mm thick for kitchen with plug , waste pipe , washers incl bedding in cement mortar to platform l or including fixing cantilever cast iron brackets, connecting union to pipe. overall size 495x420mm bowl size 410mmx330mm x160mm complete all as sepcified and directed.
S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia15 mm, complete all as specified and as directed.
S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20 mm, complete all as specified and as directed.
Refixing old steel tubing and connections in new or old position with all fittings retrieved from Serial here-in-before and fixed (walls, ceiling, floors, etc) of 15 mm dia complete all as specified and as directed.
Refixing old steel tubing and connections in new or old position with all fittings retrieved from Serial here-in-before and fixed (walls, ceiling, floors, etc) of 20 mm dia complete all as specified and as directed.
Taking up or down 15 mm steel tubing and connections including clearing for refixing or removal to store.
Taking up or down 20 mm steel tubing and connections including clearing for refixing or removal to store.
TMT steel bars 10mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping to columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia, all as specified and directed.
Form work to soffit of suspended slab such as roof slab/cooking platform not exc 200 mm thick horizontal or slopinf flate including fair finished to concrete surfaces.
M&L RCC 1:2:4 Type B-1 (using 20 mm graded aggregate) in Roof slab, shelves supported on wall/column and the like etc complete as required.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for.
S & F for Harrison rails, 20/25mm dia aluminium alloy rod (Poles, finials , ring & bracket complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls with applying two coats of distemper oil emulsion and chalk whiting, on plastered surface,prepara tory to distempreing complete all as specified and directed.
M& L for complete removal of existing treatment by scrapping, wire brushing from old walls and applying two coats of oil bound distemper over chalk whitening primer including preparation of surfaces with wall care puty as directed.
M&L for preparation of old decorated plastered surfaces of ceiling including cornices, pilasters etc and applying two coat of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling including cornices, pilasters etc and applying three coat of white wash complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of wall including cornices, pilasters etc and applying one coat of white wash complete all as specified and directed.
M & L for preparing new plaster surfaces walls including chajjas, facias etc including smoothening surface with wall care putty as per manufacturer's instructions and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M & L for complete removal of existing treatment and appllying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & dirt resistance exterior aint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.
Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing all as specified and directed.
Disconnecting electric connections and taking down old unsv main switches/DB's steel metal enclosure 02 ways/04ways/08ways duly fitted with MCB's cutouts 32 amps capacity including unserviceable wooden boards and making good the disturb surface of the complete all as specified and directed.
Disconnecting and taking down of unserviceable sub main/ service connection of any size and including steel conduit and accessories and removing from site and making good the disturbed surface complete all as specified and directed.
Taking down fan, cealing cable end, dismantling and removing fan and blades to store
M & L for point wiring complete with PVC insulated and unsheathed, copper conductor cable Multistrand FRLS single core 1100 volt grade electric cable of 1.5 sqmm (nominal area) in and including rigid PVC concealed conduit medium grade of suitable size not less than 20mm as per site requirement including 1.50 sqmm PVC insulated & unsheathed copper cable as continuous earth wire with all accessories including lugs required, complete all as specified and directed.
One light point controlled by one switch SP 230 Volts
One fan point controlled by one switch SP 230 Volts
One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent bd.
One light point controlled by 2- two way switch
One bell/ buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 sqmm
Description all as per item No 05 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm green solid copper conductor cable as continuous earth wire with lugs complete all as specified and directed.
Supply and fixing modular plate with frame of 12 module complete all as specified and as directed.
Supply and fixing modular plate with frame of 6 module complete all as specified and as directed.
Supply and fixing modular plate with frame of 3 module complete all as specified and as directed.
Supply and fixing modular plate with frame of 2 module complete all as specified and as directed.
Supply and fixing modular plate with frame of 1 module complete all as specified and as directed.
S & F modular switch 1 way 16 Amp, 1 module, complete all as specified and as directed.
S&F modular socket 6 Amp/16 Amp, 2/3 pin combined, 2 module complete all as specified and as directed.
S&F modular switch 6 Amp/10 Amp, 2/3 pin combined, 1 module complete all as specified and as directed.
S&F modular socket 6 Amp, 2/3 pin combined 2 module complete all as specified and as directed.
Supply & fix modular bell push, 6 Amp,1 module, 240 volt single pole complete all as specified and as directed.
S&F modular switch, two way 5 Amp complete all as specified and as directed.
M & L ceiling rose, 3 pin surface, white /any shade , three terminal.
S&F in replacement Bell Multi Music Type, AC 230 volt, Single Pole, complete all as specified and as directed.
S & F in replacement lamp holder , insulated body with back plate suitable for batten fittings .
S & F in replacement Fan step regulator, 120W - 2 module complete all as specified and as directed.
Supply& fix in replacement New Adore LED lamps 10W B22 COL BALL LAMP ,MAKE Cat part no- LHLDEUEBML8Z010 of HAVELLS or equivalent .
Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing in replacement 20 watts LED building security light fitting including suitable bracket and nut bolts etc complete all as specified and as directed.
Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan.
Fixing only exhaust fan (M.D. supply) and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and as directed.
Fixing only electric water heater, storage type steel body with glass lead tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etccomplete all as specified and as directed.
S&F MCB distribution board steel sheet, enclosure power coated fitted with bus bar, neutral link, earth bar din rail confirms IS-8822:96 and EIC 898-96, 415V double door complete all as specified and as directed.:-
04 way, 415 V, TPN
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
TPN 40 To 100 AMP
MCB SPN 32 amps curve 'C' breaking capacity 10KA
S&F MCB DB 08 way, 230 volt, sheet metal enclosure for MCB's, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified.
S&F SP 6-32 Amps, curve 'C' breaking capacity 10KA
M & L for concealed submain wiring with two run of 6.00 sqmm single core multi stranded ISI marked PVC (FRLS) insulated copper conductor cable drawn through concealed in surface in PVC rigid conduits and the conduit accessories not less than 25mm including one run of earth continuity conductor with 6.00 sqmm multi stranded copper conductor including cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and directed by Engineer-in-charge.cable all as specified and directed. Note:- 1. Two run of single core cable, one run of earth continuity conductor and one meter of conduit shall be measured as one unit. 2. Cost of cutting chase and making good shall be included in the quoted rate.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH all specified and directed. Note: Old Unsv electirc meter Should be deposite to E/M Store yard for BER disposal.
M&L in replacemnet of Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically in pit of depth not less than 2.25 meter below normal ground level with top edge of the earth plate at a depth not less than 1.5 meter below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore dia (light grade) connected to main switch board all as shown in electrical plate No. 3 of SSR-1991 Part I and including necessary excavation and earth work, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC type C-1 chamber, CI cover and MS frame etc., complete all as specified. Note: The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point.
M/S JAINENDRA KUMAR JAIN (BID ID -3509345)
M/s VIKAS TRADERS (BID ID -3515342)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
84131TenderDocuments.pdf
Tender Documents • 1.21 MB
BOQ_832561.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .