THE DIRECTOR
THE DIRECTOR, CSIR-CECRI, KARAIKUDI
Repair and renovation works in old MnO2 building at CSIR - CECRI, Karaikudi
2021_CSIR_81945_1
CSIR CECRI NIT No 11/2021
Open Tender
Civil Works
Item Rate
150 days
KARAIKUDI
Please refer NIT
8 documents required · 8 mandatory
₹0
Exempted
4 Oct 2021
13 Jul 2021
27 Jul 2021
13 Jul 2021
26 Jul 2021
13 Jul 2021
Amount
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles 10 mm to 25 mm
Demolishing the existing wethering course laid in roofs and including disposal / levelling near the site as directed.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area beyond 3 sq. metres
Of area 3 sq. metres and below
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
Of area 3 sq. metres and below
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
Asbestos Cement sheet
Dismantling G.I. pipes including stacking of pipes within the nearest dumping ground as per direction of Engineer-in-charge : upto 50mm dia pipe
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 manufactured sand derived from Recycled concrete aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size Recycled aggregate (RA)
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :
cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster of mix :
1:6 (1 cement: 6 coarse sand)
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.)
Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
Providing and laying Ceramic terrace tiles of size 300x300 mm (thickness to be specified by the manufacturer) , laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing precoated galvanised iron profile sheets 0.50mm thick or below. The sheet shall be fixed using self drilling /self tapping screws with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Precoated galvanised iron profile sheets will be supllied by the department)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 9 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with Non -decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Providing and laying rectified Glazed Ceramic floor tiles of size 600x600mm (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in all colours, shades, laid on cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Water thinnable cement primer
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
One or more coats on old work
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
White washing with lime to give an even shade :
Old work (one or more coats)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
110 mm bend
Shoe (Plain)
110 mm Shoe
Providing and fixing Stainless steel round handle 25mm dia bar with 300mm long including necessary screws as directed by the Enginner- in -charge
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
25 to 40 mm nominal bore
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including using of rack bolts for fixing wherever required White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Providing and fixing PVC multi trap (Nahini trap) with jalli including necessary fittings as directed by the Engineer - in- charge. 100mm dia
Providing and fixing CP two way tap of approved quality as directed by the Engineer-in-charge 15mm nominal bore
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providng and fixing precast reinforced cement concrete rings with 25mm thick of size 450mm dia & height 300mm in existing masonry walls with neat finishing as per the direction of Engineer-in-charge.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm
Providing and fixing SS towel rail complete with fixed to wooden cleats with CP brass screws of approved quality as directed by the Engineer -in -charge. 600 mm long towel rail
Providing and fixing CP coated health faucet 1.0mtr length of approved quality with necessary fittings and screws as directed by the Engineer - in -charge
Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.
30 mm thick plain PVC door shutters
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including necessary opening for drin pipes and neat finishing complete as per standard design as directed.
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)
Acid and alkali resistant tile
Removing old unnecessary clamps , angles ,curtain rods and other unwanted minor parts projected in walls & roofs. the rate inclusive of all lift and leads including necessary scaffolding as directed by the Engineer-in-charge.
Removing and placing the existing wooden furnitures and other movable items after executing the work including proper placing, cleaning wherever & whenever required as directed
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole :
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level :
1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 150mm
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15 mm nominal bore
Providing and fixing 110 mm dia PVC pipes (4kg/cm2) (Finolax or equivalent ) complete with necessary fittings as directed.
Providing and fixing 90 mm dia PVC pipes(4kg/cm2) (Finolax or equivalent ) complete with necessary fittings and clamps including cutting and making good the walls etc.
Providing and fixing 63 mm dia PVC pipes(4kg/cm2) (Finolax or equivalent ) complete with necessary fittings and clamps including cutting and making good the walls etc.
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 sqm
Providing and fixing granite of 18 mm thick gang saw cut, mirror polished (double side), premoulded and prepolished, machine cut for urinal spearator and similar locations of required size (1300mm x 600mm), approved shade, colour, texture and fixing the walls as per site condition, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Providing and fixing CP brass urinal half turn valve of aprroved quality as directed by the Engineer-in-charge. 15mm nominal bore
Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings :
Size 600x450x200 mm
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Closing the minor holes upto 0.10sqm area in existing mansonry wallls with necessary plastering and neat finishing as directed by the Engineer-in-charge
Providing and fixing Aluminium roof turbine gravity ventilator fan with following specifications, MOC of vanes, top plate & Bottom of ring made up of aluminium, Bearing with Self Lubricated - 2 Nos, Center Shaft with M.S 12mm dia with Electro Zinc Plating, Thickness of 0.5 mm , Turbine Height 350 mm , Blade of size 415x63x0.50mm ,42 Nos with 45 degree angle and triple Groove - press formed Blades, centre pipe having aluminium, centre width of ventilator 715mm, Dia of top plate 500mm, Dia of top ring 650mm, Dia of Bottom ring 610mm, Rivets - aluimium rivets, with suitable fixing arrangements and ensure leak proof in the ceiling as directed by the engineer - in -charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using flats 30x6mm for diagonal braces and central cross piece
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 100 to 250 mm diameter
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Upto 5mm depth and 5 mm width
Supplying and fixing etching sticker for glass doors/ winows /glass partition including required design as directed by the Engineer-in-chage.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes (MS tubular sections will be supplied by the Department)
12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand):
Flush Band
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.
Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in:
Channels, angles, tees and flats
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
12 mm cement plaster
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Applying priming coat:
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
Laying old RCC pavement slab of available size upto 75 mm thick of any shape laid in required line, level, curvature and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with cement mortar 1:3 (1 cement : 3 coarse sand) etc. including handling of slab and transporation all complete as per the direction of Engineerin- charge. (Old RCC slab shall be supplied by the department free of cost).
Laying of gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. (Old granite slab shall be supplied by the department free of cost).
Granite work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete, , including cutting required size rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.(18mm thick granite slab will be supplied by the Department)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured):
In cement mortar
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Cutting holes up to 30x30 cm in walls including making good the same:
With common burnt clay F.P.S. (non modular) bricks
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.
50 mm thick
Providing and fixing zinc alloyed (white powder coated) touch lock for aluminium sliding window with necessary screws etc. complete.
Cleaning the surface of bitumen road/concrete flooring of all dirt, scales, oil, grease and foreign material etc. The rate inclusive of all lift and leads and using mechanical brooms & air blowers as directed by the Engineer-in-charge.
Cleaning of MS angles from rust to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Upto 50x50mm MS 'L' angles
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.
12 mm average thickness.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 4 sq. mm
6 x 4 sq. mm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
200 mm X 150 mm X 75 mm deep
200 mm X 250 mm X 60 mm deep
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
For 6 way, Double door TPN MCBDB
For 8 way, Double door TPN MCBDB
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 X 25 sq. mm (22mm)
3.5 X 70 sq. mm (38mm)
3.5 X 400 sq. mm (82mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 X 400 sq. mm
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and paint etc. as required.
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
250 mm dia
300 mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
90 mm dia (OD-90 mm & ID-76 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
(b)Erection in all aspect including providing necessary angle iron chennels for the panel complete in all aspects as required as per site condition Including necessary civil works, as required and finishing the same to the original condition, along with cable excavation for loose/loop purpose as required.)
Furnace I/c Units : Supplying and fixing 40-63 amps rating, 415 volts, "C" curve, FP miniature circuit breaker suitable for inductive load in 6 module sheet steel enclosure with suitable blanking plate etc,complete with connections,testing and commissioning etc. as required
2x2 LED Fitting: Supply and fixing recessed mounting full glow 2x2 LED energy efficient fitting, 4200 lumens, 38 watts, glare free light along with suitable driver in the existing false ceiling with required accessories for mounting the fittings firmly in the ceiling including interconnections as required. Similar to Philips model no: 4200 lumens RC380B LED42S-6500 G5 L60W60 PSU OD or equivalent as approved by department.
LED down light: Supply and fixing recessed mounting Down lighter LED energy efficient fitting,1000 lumens, glare-free light along with suitable driver in the existing false ceiling with required accessories for mounting the fittings firmly including interconnections as required. Similar to Philips Green perform Model No: DN295B LED10S-3000 PSU WH or Equivalent as approved by department.
Supply and Fixing of 45 Watts LED/4500 Lumens street light fittings similar to Philips (BRP052series)Smart Brite luminaire having high efficient lighting including making necessary interconnections from the point to the fittings while installing the same etc as required.
Twin Tube with Powder coated fitting : Supplying of indoor industrial Twin Tube with powder coated MS box type suitable for 2x20 W lamps including 2 nos of lamps complete with all accessories, similar to the Jaquar model LUN01X2 20XC or equivalent as approved by the department
Tube light patty for the LED Tube:- Supply of standard 4 feet tubel light patty of reputed brand with holders excluding choke and starters with necessary alteration in the wirings for housing LED tubel light as required (department supply).
Exhaust Fan : Supply of heavy duty 18" exhaust fan along with louver shutter,totally enclosed,continuously rated, dynamically balanced impeller suitable for single phase power supply, 900 rpm, having minimum 2290 CFM and noise level not exceeding 60 db having 2 years guarantee and shall be conforming to the Is standards.
Cast Iron Body Earthing : Providing cast iron pipe earth pit with 2000mm long 100mm dia 7mm thick cast iron pipe including excavation, refilling with salt, charcoal, natural soil and providing masonry cover etc.,complete in all aspects as required.
20 Pair Krone DB : Supply, fixing and termination of 20 pair Krone in 30 pairMDF krone junction box with lock and key including identification of lines as required.
Ceiling Fan: Supply of 1200mm/48"ceiling fan similar to High Speed/High Breeze Model of Crompton Greaves or Norwester/New Hurricane model of Orient make or Equivalent as approved by department.
12 Ways VTPNDB with 100 A MCCB: Supplying and fixing 12 ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board (with wire way/cable end box) of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, along with 100 amps TP 18 KA, TMD MCCB having adjustable thermal and fixed magnetic rereleases with set of spreaders as incomer, interconnection between incomer MCCB and bus bars as required. The VTPN DB shall be mounted on an adequate size angle/flat and grouted/ fixed (drilling, cutting welding painting etc) firmly in the existing wall as required as per site condition complete in all aspects. The above DB shall include the following’C' series, 10 kA MCB's in the outgoing circuits TP MCB-63A-2 Nos TP MCB-32A-5 Nos SP MCB-6-32A-15Nos Blanking plates -As required.
In MNO2 Area: Removing the existing TPN and SPN DB's including frames,open type industrial panels, SFU’s of all size, Fuse carriers, Motor Starters, industrial sockets, Main switches, circuit and point wirings, fans, switch boards, power boards and light fittings with GI pipe , and other unused and worn-out electrical installations, cutting the L angle channels and other unwanted materials which is deemed to be removed in and around the Mno2 division area complete and returning the removed items to the departments stores or any such place within the institute area as directed by the engineer in charge as per site condition. Required as per site condition.
Civil Plumbing storage Area: Removing the existing old 400 A Bus bar industrial open type panel and 2 no’s TPN DB and main switch in civil plumbing storage area along with the old UG cables of various sizes, up to 6 " beyond floor level and returning the removed materials to the departments stores or any such place within the institute area as directed by the engineer in charge as per site condition.
Dismantling Item- AL Bus bar in MNO2 Division:- Removing the unused aluminium bus bars (apprx-40 mtrs of sizes 150mm) along with the structural support provided in the truss level, removing the unnessery channels/ TL pattys etc holding/mounted in the supoporting structures, removing the supports provided in the wall and removing the ground level support at minimum 6 " below the ground level with necessary gas/machine cutting as required as per site condition.in and around the MNO2 Division area,completein all aspects as required as per site condition and returning the removed materials to the stores section as directed by the engineer in charge.
A PRABAHAR
J AMBROSE
M ALAGESAN
Four Square Agencies LLP
M/s. ABHINAV PROMOTERS
tamilan builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .