Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-Finance 0 SANRPUR MISHRAULIYA PUCHPEDIYA ROAD SANTPUR MISHRAULIYA BASTI UTTAR PRADESH 272001 INDIA | BASTI | UTTAR PRADESH | 272001 | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹20.0 L+₹69,877 (3.63%)Rejected-Finance 704 NEW PUMP HOUSE NEAR RED ROSE SCHOOL BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹24.9 L+₹5.7 L (29.4%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹26.5 L+₹7.2 L (37.4%)Rejected-Finance NEW PUMP HOUSE ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
5 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Babina
GE Babina Cantt PIN 284401
SPL REPAIR OF DRAINAGE AND BLDG OF CERTAIN UNIT UNDER AGE B/R-I BABINA AT GE BABINA CANTT.
2025_MES_703694_1
8365/E8
Open Tender
Civil Works
Item Rate
180 days
GE Babina
As per tender documents
8 documents required · 8 mandatory
₹500
GE Babina
₹92,000
Yes
5 Jul 2025
5 Apr 2025
7 May 2025
5 Apr 2025
5 May 2025
21 Apr 2025
Amount
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed by the Engineer in Charge.
M&L for walling of random rubble masonry, regular courses well bonded bedded and solidly hearted, built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for walling of random rubble masonry, regular courses well bonded bedded and solidly hearted, built in CM 1:6 but except stone complete all as specified and directed by Engr-in-Charge. (Unit rate for cleaning of old stone shall be included in this item).
M&L for OLD SIZE BRICKS built in cm (1:4) using sub class 'B' bricks of compressive strength not less than 35 Kg/Sqcm straight or curved on plan exceeding 6 mtr mean radius with old size bricks all shown on drawing complete all as specified and directed by the Engineer in Charge.
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4) but except bricks (Bricks shall be obtained from demolition. Unit rate for cleaning of old bricks shall be included in this item).
M&L for raised pointing to stone masonry wall un coursed or brought up to course in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M/L for rendering 15mm thick in CM 1:4 on fair faces of bricks or concrete surfaces finished fair and even complete all as specified and directed by Engr-in-Charge.
M & L preparation of walls newly plastered surfaces & applying two coats of white wash complete all as specified and directed by Engr-in-Charge. .
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed by the Engineer in Charge.
M & L for cement concrete type C2 (1:3:6) (using 40 mm graded stone aggregate) in surface channels, drains and manhole foundation etc complete all as specified and directed by Engr-in-Charge. .
M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered necessary for work
M&L, for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed by the Engineer in Charge.
M&L, for Add or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed by the Engineer in Charge.
Demolition of reinforced cement Concrete of any description and in any position disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer in Charge. (Reinforcement shall be cut as required to facilitate demolition).
M & L for precast reinforced cement concrete (1:2:4), type B-1 (using 20 mm graded stone aggregate) as in cover slabs and similar articles with plain faces and set in cement mortar (1:4) complete all as specified and directed by the Engineer in Charge.
M & L for mild steel TMT bars 12 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips. complete all as specified and directed by the Engineer in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and complete all as specified and as directed.
Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Machine cut kota stone slab flooring 20-25mm thick n riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from froms exe 1.5 sqm and n.exe 4 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from froms n exe 1.5sqm each complete all as specified and directed.
Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in CM 1:3 or cement conc 1:2:4 type B1 as required exc half brick but not exc full brick wall complete all as specified and as directed.
M&L PCC 1:3:6 type C-1 (using 20mm graded stone aggt) as in filling in holes of hold fasts and back filling of chowkats complete all as specified and directed.
M&L Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed
S&F 2nd class soft wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F of 30 mm thick 2nd class Hard wood paneled door shutter localy made (two panel) with lock rail and panel of 9mm thick BWP commercial ply wood, the size of rail and stile is as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F Butt hinges, extruded aluminum alloy with galvanized MS sheet hinges pin anodized of100mm size type B-21 complete all as specified and directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F of 150 mm long anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
Material and labour for Steel window localy made double shutter and pressed steel frame suitable for double shutter (double for mosquito proof one glazed with glazing bars ) with side hung shutters including projecting type hinges non friction with 3mm thick 100mm long handle and two nos tower bolts 100mm long welded and including hold fast and gaurd bar and painting with one shop coat of zinc chrome primer complete all as specified and directed.
M& L for demolition cement concrete of any description in any position not otherwise specifically provided including existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime coba 80 to 100mm thick mud phuska/cement concrete/lime coba etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush and removing debries/rubbish off materials out side of Ministry of defence (MOD) land complete all as specified and directed.
M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed.
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M & L Plain cement concrete (1:2:4) type B0 using 12.5 mm graded stone agg as in coping or roof kerbs on roof chamfered on edge including troweling slightly complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stil green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and as directed.Note :- Water proofing compound shall be measured separately
Supply only integral water proofing compound complete all as specified and as directed.
M&L applying water proofing treatment with the following (a) First coat of bitumen primer conforming to IS-3384 @ 0.3Kg / sqm to be applied on prepared surface till the surface is properly impregnated (b) after the application of approved bituminous primer the water proofing memberne minimum weight 3kg/sqm and minimum 3mm thick reinforced with polyesterd non woven fabric (weight not less then 160gms/sqm) shall be laid on the primed surface by torch application method as per manufactured instruction.(c) All joints and change in direction should be curved with cement mortar (1:3) mixed with SBR latex @ 200ml per bag on cement and cured well before laying of membrane including Aluminium paint on top surface complete all as specified and directed
Taking down plaster on brick or stone wall, ceiling etc incl racking out joints hacking for keys scrubbing down with water etc complete all as specified and directed.
M&L for external rendering 15 mm thick in CM 1:4 on brick work or concrete surfaces of wall finished even and smooth complete all as specified .
M& L for two coat of cement base paint on new plastered surface over a coat of primer including preparation of surface complete all as specified and as directed
M&L for prepration of old wall surface and applying two coats of cement base paint white etc complete all as specified
M&L for prepration of old wall surface and two coat of oil bound distemper in cluding one coat of putty all as specified and as directed by the Engineer-in-Charge
M & L for preparation of old ceiling surfaces and applying two coats of white wash complete all as specified and directed.
M&L, preparing for new steel surfaces and applying two coats of synthetic enamel paint over one coat of rex oxide primer over 10 cm width or girth complete all as specified and as directed.
M&L, preparing for new wood surfaces and applying two coats of synthetic enamel paint over one coat of pink primer over 10 cm width or girth complete all as specified and as directed.
Demolition of cement concrete(un Reinforced) of any description in any position not otherwise specifically provided for etc. complete all as specified and directed.
M&L, Hardcore of guage n exc 63mm deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface Broken stone or boulders complete all as specified and directed.
Material and labour 75 mm thick PCC 1:3:6 type C2 using 40 mm graded aggregate as in plinth protection finished fair and even w/o using extra cement and making groove of 10mm width at every 3m intervals and at diagonals and filling the joints with bitumen mastic( a mix of bitumen and sand in 1:1 by weight) complete all as specified
M&L PCC 1:4:8 type D2 using 40mm graded stone agg as in filling Sub base/flooring complete all as specified and directed.
Material & Labour for writing letters or figures (block, Roman, Italic or Indian) n.exc.30 cm high complete all as specified and directed.
Taking down carefully unserviceable aluminium point wiring (light, fan, socket or power) complete with fitting such as switches, ceiling roses, lamp holders, sockets, fan regulators, wooden terminal box plastic laminated sheet cover from TW battens including TW batten or drawing from existing conduit removing including TW batten all as specified and as directed by Engr-in-Charge.
Taking down carefully existing wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size any capacity from boards complete all as specified and as directed.
Taking down carefully sub main wiring / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed.
M & L for concealed point wiring for one light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 19 mm dia, clip, with MS terminal boxes (not less than 1.0 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing all as specified and as directed .
Description same as per item No 55 above but one fan point controlled by one switch & regulator.
Description same as per item No 55 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
Description same as per item No 55 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
Description all as per item No 55 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
S&F switch piano flush button type 5 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F switch piano flush button type 15 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and as directed.
S&F ceiling rose,surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F Sheet metal enclosure double door concealed suitable for distribution board when MCB to be used having 100 Amp rated bus bar 8 ways 240 volts complete all as specified and as directed.
S&F MCB single pole and neutral 40 Amp/63 Amp 240 V ,10KA , 'C' series, connected with copper lugs complete all as specified and as directed.
Supply and laying GI pipe 50mm bore "LIGHT GRADE" in trenches, under floors, roads, along poles for protection of cables, including sealing ends complete all as specified and as directed.
Supply and laying, or fixing or passing through HDPE pipe connecting and testing in replacement of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 25 sqmm 4 core as per IS 7092 Pt-I complete all as specified and as directed.
S&F MCB single pole 6 to 32Amps 240 V,10KA, 'C' series, connected with copper lugs complete all as specified and as directed.
S&F MCCB 4 pole, 415V, AC , 3 phase, 50 HZ, breaking capacity 16 KA with fixed thermal and fixed magnetic setting of capacity 63 Amps 'C' series complete all as specified and as directed.
S&F MCCB DB/TPN vertical type suitable for 125 amps MCCB as incommer made of sheet steel, powder coated with neutral bus bar 200A, neutral link, IP-43-IK09 protection grade 415 Volts 4 way double door complete all as specified and directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning filling in including spreading ,levelling,watering and well ramming in layers not exc 25cm complete all as specified and as directed.
Removing excavated at a level n.exc 50m m above the starting point complete all as specified and as directed.
S & F Lamp holder,PVC/Urea type with back plate suitable for batten fittings complete all as specified as directed
S & F delux Fan Regulator electronic rotary, step type 240 Volt 50 Hz, complete all as specified as directed.
S&F LED security/street light fittings1x35W LED 5700K energy saving and envoiremental frendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LED as light siurce and electronic driver suitable for pole dia 35mm including 35mm dia light grade tube bracket, bend to shape 1.80m long with two numbers clamp of size 50mmx6mm with nuts, bolts, washers etc including connection with 1.5Sqmm two single core PVC insulated and PVC sheathed cable stranded copper conductor upto ceiling rose and fixing on wall /pole complete as ditrected by Engineer in Charge. Make: Bajaj Cat Part No BRLEP20WLEDWH or equivalent make as specified in Appendix B to particular specification.
S & F 9W/10W LED retrofit lamp B-22 holder base with polycorbonate body and aluminium heat sink complete all as specified as directed. Make C&S Cat No LTHPLEDLAMP7W/B22 or equivalent make as specified in Appndx 'B' to PS .
M&L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into conduit (Existing / new) including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code concealed on wall complete all as specified and as directed Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) New conduit 25mm dia and conduit accossories shall be included in the quoted rates.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 20 W LED 6000k 4 feet Decorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 28watts lamp fitted including wiring upto and terminal into ceiling rose complete all as specified and directed by Engr-in- Charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick weithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M/s Pratham Enterprises (BID ID -3288760)
DEVENDRA ENTERPRISES (BID ID -3291826)
N K ENTERPRISES (BID ID -3292082)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .