Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.9 LAccepted-AOC | ₹81.9 L Quoted ₹82.9 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹88.8 L+₹5.9 L (7.12%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹88.8 L+₹5.9 L (7.12%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | L3₹91.4 L+₹8.5 L (10.3%)Rejected-Finance | ₹91.4 L+₹8.5 L (10.3%) | L3 | Rejected-Finance HIGHER BIDDER |
| 4 | L4₹91.5 L+₹8.6 L (10.3%)Rejected-Finance FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹91.5 L+₹8.6 L (10.3%) | L4 | Rejected-Finance HIGHER BIDDER |
| 5 | L5₹91.8 L+₹8.9 L (10.8%)Rejected-Finance | ₹91.8 L+₹8.9 L (10.8%) | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹95.3 L
EMD Value
₹1.7 L
Closing Date
11 Jun 2020, 6:00 pmClosed
SH M V SANKAR SE CWE
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO BUILDING P 80 P 82 HANSA MARRIED ACCOMADATION AT INS HANSA UNDER GE NW VASCO
2020_MES_341959_1
85254/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE NW VASCO
₹1.7 L
Yes
4 Sept 2020
30 Apr 2020
13 Jun 2020
30 Apr 2020
11 Jun 2020
28 May 2020
Amount
Schedule 'A' -Part I ( B&R Works)
M&L for chipping , removing carefullly the concrete work by low impact hammer ,breakar without damaging the structure & cleaning and disposal of debries out side the premises etc complete all as specified and as directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement with wire/rotary wire brush, making the surfaces free from loose material dirt etc complete and applying two coats of alkaline rust converting primer FEOVERT conforming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB all as specified and as directed.
M&L for replacement of steel reinforcement with TMT CRS bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET-RB all as specified and as directed.
M & L for carrying out Bi-polar migratory corrosion inhibitor EPCO-KP-100 or equivalent on concrete surface. This inhibitor shall have migratory kind of property which permits the material to migrate to a vertical extent of 100mm , through pores of concrete, inhibiting the corrosion and de-passivating the electro-chemical reaction , it should have property to attract anode as well as cathode , which is purely alkaline in nature(Ph-9.5) so it has no carcinogen activity with concrete all as specified and as directed.
M&L for drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes in structural members at the intervals of 500 mm center to center in staggered manner or as directed in RCC structural element. Work shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum of about 12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements.
M&L for Injecting of site cement slurry grout, in the ratio 1:2 (1- Cement, 2-water) including super plasticizer (Supercom-100) 250 ml/50 Kgs of cement mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of grout by means of pump at a pressure of 0.5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled for repair to wall & slab all as specified and as directed.
M&L for injecting low viscosity MONOPOL (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including, mixing of materials :mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching .Grouting maintain the pressure at exit 0.5 to 1.0 kg/cm2 by monitoring pressure guage at exit. Grout the material through prefixed nozzles in the structural elements at the rate of 100ml per nozzle. Repeat the process for all the nozzles in beam and columns all as specified and as directed.
M&L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all as specified and as directed.
M&L for building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5 Cement-15 sand) -in damaged areas in 30mm thickness including leveling profiling etc all as specified and as directed.
M&L for providing and applying jacketing around columns with micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specifications complete. Notes: (i) Reinforcement shall be measured and paid separately. (ii) Quoted rates shall include for jacketing, formwork and micro concrete.
M&L for TMT steel bars CRS 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
M&L for TMT steel bars CRS 6 mm to 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
M & L for TMT CRS bar 5mm dia and over upto and including 10 mm cut to length, bend to shape required including cranking bending & hooking ends & binding with MS wire annealed not less 0.9mm dia for stirrups/binders all as specified and as directed.
Dismantling/Taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled all as specified and as directed.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the morther slab. Fillig the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalant) on prepared concrete/plastered surface by diluting 2 parts of Primeseal with 1 part of water and allow to dry for 04 hours. Apply the first coat of waterproofing coating (Dr. Fixit Newcoat/ Waterseal concentrate of M/s Krishna Conchem Products) without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as specified and as directed.
M&L for rendering 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement. Note :- Integral water proofing compound shall be measured and paid separately.
Demolition of un-reinforced cement concrete in ground floor and pavings n exc 15 cm thick (below or above ground level) and removing all the rubbish off the premises complete all as specified and as directed
Demolition of concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L for cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades , shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc; and making good, cutting exceeding 10cm but not exceeding 20cm girth all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing removing rubbish off the premises all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
Taking down chowkats or frames not exceeding 1.5 sq.m. each with shutters without taking off shutters from the frames and removing off site etc complete all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 sq.m and not exceeding 4 sqm each with shutters without taking off shutters from the frames and removing off site etc complete all as specified and as directed.
Taking down shutter of any description not exceeding 1 Sqm all as specified and as directed.
Taking down shutter of any description exceeding 1 Sqm and not exceeding 2 sq m all as specified and as directed.
Taking down shutter of any description exceeding 2 Sqm all as specified and as directed.
Dismantling old particle boards/plywood as in shelves boarding, any description, fixed in any position with nails all as specified and as directed.
Taking down cement plaster at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed.
Dismantling asbestos cement / PVC pipe including clamps all as specified and as directed.
Demolition of brick work or stone/boulder masonry,built in all quoins, arches, pillars etc , but excluding ashlar facings, dressed boulder masonry, built in cement mortar complete all as specified and as directed.
M & L for 75 mm thick cement concrete type B1, 1:2:4 using 20 mm graded stone aggregate as in floor topping surfaces finished even and smooth without using extra cement all as specified and as directed.
Supply only glass dividing strips of size 38 mm x 3 mm as in floors all as specified and as directed.
M & L for providing 40 mm thick cement concrete type B1, 1:2:4 using 20 mm graded stone aggregate as in floor finished surfaces finished even and rough to receive to topping layers like similar work as arequired all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15 mm thick cement plaster 1:6 for laying floor finishes to receive floor tiles all as specified and as directed.
M & L for vitrified ceramic tiles light / dark coloured shade, 10 mm thick (Square/rectangular), area of each tile not exceeding 0.36 sqm as in floors etc set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M & L for non - skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry at 3 kg /sqm and pointed in white or coloured cement to match existing surfaces all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:4 to receive tiles in vertical surfaces all as specified and as directed.
M & L for vitrified ceramic tiles light coloured shade, 10 mm thick (Square/rectangular), area of each tile not exceeding 0.36 sqm as in skirting dado etc set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surfaces 300 x 450 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over all as specified and as directed.
M&L for 18-20 mm thick granite as approved type machine cut, bedded and jointed with grey cement slurry over and including screed bed of 20 mm thick in cement mortar 1:6 and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing for treads etc complete all as specified and as directed.s directed.
M&L for 18-20 mm thick granite machine cut,in vertical / horizontal set of jointed in cement slurry over and including rendering coat of 15 mm thick in cement mortar 1:4 and pointed in cement mixed with pigment to match the shade of slab including rubbing,cutting and polishing all as specified and as directed.s directed.
M&L for 18- 20 mm thick granite of any type work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite all as specified and as directed.
M&L for RCC Type A 1 ,1:1.5:3 using 20 mm graded stone aggregate in slabs supported on walls , beams etc .and columns landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. Note: Reinforcement shall be measured and paid separately.
M&L for use & waste wooden form work (rough finished) to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal/sloping), all as specified and as directed.
S & F Solid PVC one or more rebate (single/double) door frame of size 50 mm x 95 mm made out of 5 mm single side prelam PVC sheet reinforced with MS square tube all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with head moulded prelam PVC 'C' channel having a both side prelam PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and both side prelam PVC sheet for top rail, lock rain & bottom rail paneling of plain gap insert for top rail & bottom rail paneling of both side prelam PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails feathered at edges/with suitable PVC sheet beading and jointed together with solvent cement all as specified and as directed.
All as per Item No.46 above but wire gauzed i.e. panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly all as specified and as directed.
S&F Aluminium anodised, 150mm barrel tower bolts of extruded section and fixed all as specified and as directed
S & F 200 mm long aluminium, anodised, barrel tower bolts of extruded section all as specified and as directed.
S&F 100 mm size butt hinges medium weight cold rolled stainless steel all as specified and as directed.
S&F Aluminium handles, cast type, anodised 125mm long fixed with screws all as specified and as directed
S&F 150 mm long extruded aluminium alloy handles, fabricated type, anodized all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy all as specified and as directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of cover plate 140 mm all as specified and as directed.
S&F Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm prelam colour PVC sheet reinforced with MS square tube all as specified and as directed.
S&F Factory made solid panel prelam PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded PVC ‘C’ channel having single side PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both face prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as specified and as directed.
S&F 12 mm thick single side prelaminated wood grain solid PVC sheet suitably fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work including all hardware fittings all as specified and as directed.
S&F 18 mm thick single side prelaminated wood grain solid PVC sheet suitably fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work including all hardware fittings all as specified and as directed.
S&F Powder coated aluminium window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the JINDAL/HINDAL CO standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10 mm dia rod fixed with and including standed aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and as directed
S & F Aluminium alloy wire mesh, 0.45 mm dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples all as specified and as directed
S&F 4mm thick sheet glass ordinary quality not exceeding 0.5 sqm each pane all as specified and as directed
S&F Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull or manual type 1.25mm thickness of laths all as specified and as directed
S&F Safety lever locks mild steel with 4 levers for rolling shutters all as specified and as directed
M&L for preparing new surfaces of iron and steel and applying one coat of aluminium red oxide primer and two coats of aluminium paint over 10 cm width or girth all as specified and as directed
S& F Stainless steel railing for design No RMG - 159 or as approved including all accessories and fittings(Chain, etc) including necessary fixing arrangements all as specified and as directed.
M & L for surface preparation by mechanical means to remove all loose particles laitance, oil and grease etc and applying two coat of Dr fixit pidifin 2K all over the sunken portion and upwards over the masonry wall up to 6-7 feet and 6 to 8 hrs after completion of first coat, take up second coat application in a direction perpendicular to the first coat. After the 2nd coat is completely dry apply a 3rd coat of Dr fixit Pidifin 2k and sprinkle coarse sand while it is still wet all as specified and as directed
M &L for plain cement concrete type E2 ,1:5:10 for filling in sunken floor all as specified and as directed
M&L for PCC 1:3:6 type C-2, 75 mm thick padding to required slop in sunken floor finished even and smooth without using extra cement all as specified and as directed
M&L for providing 150 mm thick cement concrete type B-2 , 1:2:4 using 40mm graded stone aggregate with water proofing compound at the rate of 3% of weight of cement as in water tank rest plate form even and smooth all as specified and as directed
M&L for rendering 15mm thick in cement mortar 1:3 cement plaster on fair faces of brick or concrete surfaces finished even and smooth without using extra cement, with water proofing compound at the rate of 3% by weight of cement all as specified and as directed
Dismantling of asbestos cement (Corrugated or semi corrugated etc) as in roof covering all as specified and as directed
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed
S & F Roof trusses (framed), trussed, purlins,rafters, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to (Fe 410-W(Gde-E- 250) all as specified and as directed
M&L for pre - cast cement concrete type C-1, 1:3:6 using 20mm graded stone aggregate block masonry with solid blocks built in cement mortar 1:6 all as specified and as directed
Taking up or down steel water tubing and connections 15 mm dia all as specified and as directed
Taking up or down steel water tubing and connections 20 mm dia all as specified and as directed
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 16 mm all as specified and as directed
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm all as specified and as directed
Dismantling PVC water tank 1000 ltr complete all as specified and as directed.
S&F 1000ltr rotational moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position all as specified and as directed.
S&F 500ltr rotational moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position all as specified and as directed.
Disconnecting existing tanks of capacity exceeding 500 and not exceeding 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting and reconnecting and re-fixing in position all as specified and as directed. Note: Cleaning shall be measured and paid separately
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. capacity exceeding 500 and not exceeding 1000 ltrs, all as specified and as directed.
S&F PVC ball valve 20mm dia high pressure of PTMT with aluminium rod & high density plastic ball screwed for iron pipe all as specified and as directed.
S&F 20 mm bore dia stop/Gate valve cast copper alloy screwed down high pressure with crutch or bitter fly handle screwed both ends for iron pipe or for union, complete all as specified and as directed.
S&F in repairs vitreous china wash basin, white, flat back, size 580x450 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets all as specified and as directed.
S&F in repairs vitreous china under counter wash basin, size 575 x 430 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand all as specified and as directed. Make: Cat No-91039 GRANDE of Hindware or equivalent as per Appendix ‘B’
S & F in repairs push type pillar cocks fancy type cast copper alloy chromium plated concealed type with necessary fixing arrangements and connecting to water pipe connected fixing complete all specified and as directed
S & F Vitreous china white squatting pan orissa pattern of size 580mm x 440 mm with integral foot rests including necessary lime concrete and 100 mm bore cast iron ‘P’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, fixed as in repair, complete all as specified and as directed.
S & F in repairs vitreous china white wash down water closet pedestal pattern including necessary lime concrete and 100 mm bore cast iron ‘S’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, including necessary connections and jet pressure with nozzle all as specified and as directed.
S&F in repair PVC low level flushing cistern 10 ltrs capacity ISI Marked including all accessories and 32 mm dia PVC flush/discharge pipe including float valve, inlet PVC connection 15mm bore all as specified and as directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450 m all as specified and as directed.
S&F PVC waste pipe 32mm dia of length 900m m PTMT all as specified and as directed.
S&F in repais reflection Mirror size 60 x 45 cm all as specified and as directed Make :Parryware Cat No C 8607 or equivalent of Saint Gobain/Modiguard
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified and as directed
S & F in repairs towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs all as specified & as directed
S & F in repairs 125mm dia CP brass shower rose with swivel joints, any colour CP brass all as specified and as directed
S & F in repairs 15mm bore stop valves of brass chromium plated , screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) all as specified & as directed
S & F in repairs stop cock brass chromium plated screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union of 20 mm bore fixed in repairs all as specified and as directed
S & F Bib tap of brass chromium plated, 15mm bore, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed
S & F in repairs low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm, 450mm long, heavy duty with two sets of brass nuts & washers (one at each end)etc suitable for 15mm bore of pipe all as specified and as directed
S & F Shelf PTMT fixed to wall with steel screws and PVC rawl plug all as specified & as directed Make: Prayag or equivalent as approved by GE
S & F 110 mm bore PVC (SWR) "P" Trap all as specified and as directed
M&L PVC (SWR) gully traps 125 x 110 mm, setting and jointing with solvent cement all as specified and as directed
M&L PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement all as specified and as directed
S&F in repairs kitchen sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mmx460mm bowl size 410 mmx330mmx 160mm etc complete all as specified and as directed.
S&F Stainless steel kitchen plate rack of approved make, size not less than 900mm x800mm and weight not less than 6.00 kgs each all as specified and as directed
S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls all as specified and as directed
S&F in repairs 75mm dia PVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches all as specified and as directed
S&F PVC (SWR) bends any radius, 110mm bore, fitted with oval access door all as specified and as directed
S&F bend suitable for 110mm dia PVC (SWR) pipe all as specified and as directed
S&F PVC (SWR) bends any radius, 75mm bore, fitted with oval access door all as specified and as directed
S&F PVC (SWR) reducers any radius 110mm bore all as specified and as directed
S&F 110mm bore PVC (SWR) junction, single (single T) equal or unequal with door access all as specified and as directed
S&F PVC (SWR) vent cowl 75mm dia all as specified and as directed
S&F High density polythene pipe(HDPE)of pressure rating 6 Kgf /Sq cm fixed comp to wall or laid in tranches or under floors.(50 mm bore) including all fittings all as specified and as directed
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement in cement mortar 1:4 all as specified and as directed
M&L for dubbing out average 20 mm thick on irregular face of external and internal walls surfaces (when specificially ordered in writing) in cement mortar 1:6 all as specified and as directed
M&L for rendring 15mm thick on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement in cement mortar 1:6 all as specified and as directed
M&L for rendering 15mm thick on other than fair faces of brick or stone masonry surfaces of walls in cement mortar 1:4 in two coats, 10 mm thick and finished with 5mm thick mixed with approval water proofing compound at the rate of 3% by weight of cement finished even & smooth without using extra cement all as specified and as directed Note : Water proofing compound will be measured and paid separately.
Supply only water proofing compound all as specified and as directed
M&L for rendering 5mm thick on ceiling concrete surfaces finished even & smooth without using extra cement in cement mortar 1:3 all as specified and as directed
M&L for applying three coats of white wash on newly plastered surfaces of wall including preparation of surfaces all as specified and as directed
M&L for complete removal of existing treatment and applying three coats of white wash on old plastered surfaces of wall including preparation of surfaces all as specified and as directed
M&L for two coats of oil bound distemper over a coat of primer with 3mm wall care putty finish after preparation of new plastered surface all as specified and as directed
M & L for complete removal of existing treatment and preparation of old surfaces of painted walls and applying two coats of acrylic anti-fungal weather proof exterior grade paint of first quality all as specified and as directed.
M&L for preparation of new surface and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer all as specified and as directed.
M&L applying one coat of white wash on old plastered surfaces of ceiling including preparation of surfaces all as specified and as directed.
M&L applying three coat of white wash on new plastered surfaces of ceiling including preparation of surfaces all as specified and as directed.
M&L for applying two coats of water proofing treatment by using araldite builder barrier rain coat or equivalent @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat (alongwith suitable pigments for colour as directed all as specified in manufacturer's instructions and to be applied through applicator of authorised manufaturer with 5 Years guarantee.
M&L for preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel and iron work of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed
S&F in repairs harrison curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc all as specified and as directed
M&L for precast cement concrete type B1, 1:2:4 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 all as specified and as directed
M & L for cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate in kerbs or mud stops, rounded or chamfered on edges all as specified and as directed
M&L for cement concrete 75mm thick type C-2, 1:3:6 using 20mm graded stone aggregate as in plinth protection all as specified and as directed
Schedule 'A' -Part II ( Internal Electrification Works)
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits/casing capping with fittings such as switches ,ceiling roses, pendants, regulators, bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium grade with all accessories of same grade fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light/fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per Item No 140 here in before, but for One bell point controlled by one bell push complete all as specified and as directed.
All as per Item No 140 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium duty, with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
M & L for one cable TV point wiring with PVC Coaxial wire insulated cable of standard required size drawn in and including concealed PVC rigid conduit in a length 20 m, terminated in to any required module as in required size including inner/outer plate Emerald/Ovation/Platinum/Sapphire complete for one TV connector point firm grip due to spring action in perfect contact and making connection from main coming TV cable all as specified and as directed
M & L for one telephone signal cable point wiring with insulated signal cable of standard required size drawn in and including concealed PVC rigid conduit in a length 20 m, terminated in to any required module as in required size including inner/outer plate Emerald/Ovation/Platinum/Sapphire complete for one telephone jack socket and making connection from main coming Signal cable/DB complete as specified and as directed.
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing capping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with two runs of single core 10 Sq mm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as Tees, elbows, junction boxes etc, as required fixed concealed in wall along with one run of 10 Sq mm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. Note :- Three runs of cable and one run of PVC casing capping/conduit shall be measured as one unit
S & F in repairs modular switch single pole one way 6 A, 240 V complete all as specified and as directed
S & F in repairs modular bell push ,flush type, 6 Amps complete all as specified and as directed.
S & F in repairs modular switch single pole one way 16 A, 240 V complete all as specified and as directed
S & F in repairs modular socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed
S & F in repairs modular socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 volts complete all as specified and as directed
S & F in repairs ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S & F in repairs fan step regulator, 120W - 2 module all as specified and as directed
S & F in repairs call bell AC, 230 Volts single pole, ding-dong sound type all as specified and as directed
Taking down unserviceable any type of main switch, DB's including MCBs including wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
S&F 20 Amps SPN AC Box all as specified and as directed
M & L for DB with sheet metal enclosure double door 240 volts, 12 way with 200 Amp rated bus bar single pole & neutral double door type for MCBs including mounting work as required in position .complete all as specified and as directed
S & F in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
Dismantling of water heater of any capacity from the position and removing to store all as specified and as directed.
S & F storage type water heater (Geyser) 25 Ltrs capacity BEE 5 star rated of existing wall Including electrical and water supply connections and testing for its satisfatory functioning complete all as specified and as directed.
M & L for earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 3 of SSR part I including necessary excavation and earth work, GI Pipe 20 mm bore light grade for watering with funnel, wire mesh, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B 0 with 8 mm dia TMT bar and handle with lifting hooks, adequate quantity of charcoal dust and common salt etc including testing and taking out old unserviceable any type complete all as specified and as directed.
Taking down from position opening the body cover of ceiling fan of 1200 mm sweep any type, any make and cutting the existing winding without damaging the stator removing the coil insulation and putting new wire of suitable gauge with correct number of turns of auxiliary and main winding, varnishing and baking complete and soldering new lead of copper wire three core cable of size 23/0076 testing complete including replacing U/S ball bearings and including transportation from working site to workshop and back and refixing in position with new rubber seal, split pin and MS nut bolt and testing all as specified and as directed
Taking down exhaust fan from the position and removing to store all as specified and as directed.
S & F in repairs energy efficient surface Mounted LED Luminaire 20 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr complete all as specified and as directed Make : - Bajaj Cat No BCLSBAL 20W CW or equivalent in Philips/CG
S & F in repairs energy efficient surface Mounted LED Luminaire 10 watts 2' long, with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 m all as specified and as directed
S & F in repairs 1x36 watts LED building security light made up of pressure die cast housing with toughened glass and individual LEDs with secondary optics and IP66 protection for building security lights all as specified and as directed Make : Bajaj Cat No BRTFG 36W LED or equivalent in Philips/CG
M & L for street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc all as specified and as directed
M & L for exhaust fan AC single phase 230V of size 300 mm sweep heavy duty with louver and connecting up including provision of flexible copper wire three core of size 23/0.0076 from ceiling rose/PVC connector to exhaust fan all as specified and as directed
Supply, install, testing and commissioning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation made out of 2 mm thick CRCA sheet duly powder coated, CPRI approved, factory fabricated. Panel board shall have front opening with hinged type doors and rubber gasket, handles ,industrial type locking arrangement and see through glass for meter reading ,bus bar chamber and switch gear compartment , bottom cable entry holes for incoming and outgoing cables, earthing terminals, danger notice plate, each compartment shall be numbered/lettered for indication, copper bus bar duly covered with colour coded heat shrinkable sleeves duly fixed over DMC/SMC insulators housed in a separate bus bar chamber and including providing control wiring with PVC insulated, flexible, multi stranded copper conductor cables of adequate size and of adequate length duly ferruled crimped with suitable lugs/thimbles etc and including connecting of existing incoming and outgoing cables. Panel board shall be mounted on and including MS angle iron frame of suitable 50X50X6mm size duly painted and PCC 1:2:4 type B1 for foundation/Platform to suit the site requirement and removing old existing electric meters after disconnection of electric supply and deposit in MES store yard complete all as specified and directed and comprising of following:-
(i)MCCB 100 Amps, 4 pole, 25 KA, 415 volts, 50Hz - 01 No (ii)MCB DP 40 Amps, 10 KA, 240 volts, 'C' curve, 50Hz - 5 Nos (iii) Static energy meter in poly carbonate body with LCD type display in class 1.0 as per IS:13779 single phase, ISI marked, 5-30Amps,240 volts,50 Hz - 5 Nos (iv) TPN copper busbar of rating 80 Amps - 01 Set (v) Voltmeter analogue type with VSS - 01 set (vi) Ammeter analogue type with ASS and suitable CTs - 01 Set (vii) LED phase indication lamps RYB - 01 set
Schedule 'A' -Part III ( External Electrification Works)
Taking down of old unserviceable cable of any core and any size from any description all as specified and as directed
S&F Under ground LT Cable XLPE insulated heavy duty armoured, (earthed) electric power cables (heavyduty) with aluminium conductor, ISI marked as per IS : 7098( Part-1), 11000 volts, grade cross sectional area 25 sq. mm 4 core laid in trenches/ fixed on walls/ poles/ ceilling/floors etc. complete all as specified and as directed Note: Excavation, PCC cable cover and Sand for cushioning shall be measured and paid separately
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil getting out and levelling of bottom surface to required level for laying of UG cable all as specified and as directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in soft/disintegrated rock getting out and levelling of bottom surface to required level for laying of UG cable all as specified and as directed
Removing excavated material of soils from site to a distance not exceeding 50 m away and depositing where directed not exceeding 1.5 m from the starting point.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as specified and as directed
Supplying & Laying in trenches clear sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified and as directed Note:Punned thickness of sand shall be measured and paid
Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40 mm in trenches to protect under ground cable complete all as specified and as directed.
Supplying & fixing GI pipe light grade ISI marked including all fittings on wall or laid on floor as required position of size 50 mm bore all as specified and as directed
Excavation in trenches by cutting of road/ concrete/ bituminous/PCC hard standing getting out and levelling of bottom surface to required level for laying of pipe/cable including making good the existing surface with same finish to match the original finish all as specified and as directed
M/S jvsr constructions
M/s RAJ CONSTRUCTION
M/s J.D. DESAI
M/S G.N.POWAR
M/S P S BABU
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .