Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.9 L+₹54,534 (2.97%)Rejected-Finance H 8 NO 15 SCHOOL KE SAMNE OUTSIDE JASSUSAR GATE BIKANER | BIKANER | BIKANER | RAJASTHAN | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.8 L+₹1.4 L (7.67%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in c(vi) Cat. | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in c(vi) Cat. |
Tender Value
₹19.3 L
EMD Value
₹38,500
Closing Date
11 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Sirsa
Military Engineer Services, Garrison Engineer (AF), Sirsa, Haryana-125055
GE/SRA/T-50/2022-23
2022_MES_561563_2
GE/SRA/T-50 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
365 days
GE (AF) Sirsa
Please Refer Tender Documents
3 documents required · 3 mandatory
₹500
GE (AF) Sirsa
₹38,500
Yes
10 Feb 2023
21 Dec 2022
13 Jan 2023
21 Dec 2022
11 Jan 2023
28 Dec 2022
22 Dec 2022 - 24 Dec 2022
Amount
Annual Maintenance Contract for Fire Fighting System, Fire Alarm & Fire Detection System at ATC, Including dismentling & refixing of unservicable items complete all as specified and as directed comprising of the following :- Fire Fighting System :- (a) Fire Fighting Panel - 01 No. (b) Jockey Pump 10 HP - 01 No. (c) Electric Driven Pump 75 HP - 01 No. (d) Diesel Engine Driven Pump 75 HP - 01 No. (e) Fire Hydrant Landing Valve - 16 No. (f) Hose Box - 10 No. (g) Branch Pipe - 10 No. (h) Hose Reel Drum - 10 No. (j) Hose 15 Metre Long - 10 No. (k) Fire Hydrant Stand Post - 06 No. (l) CI Sluice Valve 80mm - 05 No. (m) Fire Brigade - 01 No. (n) CI Non Return Valve 100mm-05 No. (o) CI Foot Valve 100mm - 03 No. (p) MS ERW Pipe 150mm - 185 RM (q) MS ERW Pipe 100mm - 209 RM (r) MS ERW Pipe 80mm - 95 RM (s) GI Heavy Duty Pipe 80mm - 12 RM (t) GI Heavy Duty Pipe 40mm - 190 RM (u) GI Heavy Duty Pipe 25mm - 160 RM (v) Sprinkle Glass Tube type - 92 No. (w) Sprinkle Glass Tube Upright type- 59 No. Fire Detection & Alarm System :- (a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 No. (c) Smoke Detectors - 58 No. (d) Heat Detectors - 58 No. (e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No (j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible wire - 1660 RM (Note- Old U/S part will be replaced and paid seperatelly under respective item)
Annual Maintenance Contract for Fire Fighting System, Fire Alarm & Fire Detection System at SRE Including dismentling & refixing of unservicable items complete all as specified and as directed comprising of the following :- Fire Fighting System:- (a) Fire Fighting Panel - 01 No. (b) Jockey Pump 180 LPM at 70 mtr head - 01 No. (c) Electric Driven Pump 2280 LPM at 70 Mtr head - 01 No. (d) Diesel Engine Driven Pump 2280 LPM at 70 mtr head ,water cooled with 2 x 180 AH bty with AMF panel - 01 No. (e) Fire Hydrant Landing Valve - 11 No. (f) Hose Box - 11 No. (g) Branch Pipe 63 mm - 22 No. (h) Hose Reel Drum - 10 No. (j) Hose Canvas 15 Metre Long - 12 No. (k) Fire Hydrant Stand Post 80mm - 4 No. (l) Hose Canvas 30 Metre Long - 10 No. (m) CI Sluice Valve 150 mm - 3 No. (n) CI Sluice Valve 100 mm - 2 No. (o) Fire Brigade 4 way 63mm - 01 No. (p) CI reflux valve Valve 150 mm with bypass arangement - 3 No. (q) CI Foot Valve 100mm - 03 No. (r) MS ERW Pipe 150mm - 206 RM (s) MS ERW Pipe 100mm - 48 RM (t) MS ERW Pipe 80mm - 9 RM (u) GI Heavy Duty Pipe 80mm - 12 RM (v) GI Heavy Duty Pipe 40mm - 190 RM (w) GI Heavy Duty Pipe 25mm - 160 RM Fire Detection & Alarm System:- (a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 03 No. (c) Multi senser detector Smoke & Heat with base - 27 No. (d) Fire alarm sounder/siren electronic type 65 DB to 120 DB -2 No (e) Manual Call Point - 06 No. (f) Addresable Control Module - 06 No. (g) Fault/ Short Circuit Isolator - 04 No. (h) Remote Response Indicator - 27 No (j) PVC Conduit Pipe 25mm - 416 RM (k) Copper HFFR PVC cooper counductor cable - 1940 RM (Note- Old U/S part will be replaced and paid seperatelly under respective item)
Annual Maintenance Contract for Fire Alarm & Fire Detection System at WSA Including dismentling & refixing of unservicable items complete all as specified and as directed comprising of the following :- Fire Detection & Alarm System:- (a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 No. (c) Smoke Detectors - 58 No. (d) Heat Detectors - 58 No. (e) Manual Call Point - 14 No. (f) Control Module - 59 No. (g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No. (j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible Wire - 1660 RM (Note- Old U/S part will be replaced and paid seperatelly under respective item)
Annual Maintenance Contract for Lift of 08 Passenger/ 544 Kg ( Manufactering No 10943048/ Schniender) at ATC, Technical area as per Terms and Conditions given as follows:- (a) Servicing of Lift at Regular Intervals and as Frequently as the Company deems necessary based on the Age, Nature and Condition of the Elevator and take all Reasonable Care and Maintaining of Lift Equipment in Safe and Proper Working Condition. (b) Carry out the Servicing Work as required whenever possible on a Day including Sundays & Holidays and during Regular Working Hours. (c) Replenish the Gear and Motor bearing with necessary Manufacturer recommended Lubricants whenever necessary and All Parts of the Lift will be checked, cleaned and lubricated to keep them, both Mechanically and Electrically in Perfect Working Condition. Replacement of Unserviceable Parts will be included in Quoted Unit Rate. (d) Carry out according to its Standards Customary Annual Safety Test to Examine All Safety Devices. (e) Lift AMC will be as per Terms and Conditions of SCHINDLER Company. (f) Contractor has to submit AMC within 20 Days after Acceptance of Tender. If the Contractor fails then necessary Recovery will be made as per Terms and Conditions of the Contract. NOTE : Contractor is responsible for Working and Inspection of Registration for the Year 2021-22 of Lift by Lift Inspector Cum Executive Engineer, Electrical Inspectorate, Haryana - Hisar is included in Quoted Unit Rate.
All as per Srl item No 04, but for Lift of 06 Passenger/ 408 Kg (Manufactering No L-13830/ Jhonson ) at SMC .
S&F in repairs Automatic Rescue device with mother board suitable for lift complete all as specified and directed by Engineer-in-Charge.
S&F Battery 12V, 12 AH dry type complete all as specified and directed.
S&F in repairs fire hydrant landing valve type A single head outlet of 63 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Hose Box made of 18 gauge MS steel of min size 800m x 600 mm x 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside box complete all as specified suitable to house 02 Nos hose reel drum 02 Nos Gun metal nozzle complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Branch pipe gun metal 63mm instantaneous inlet made threaded outlet 15mm bore nozzel short complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of Hose reel Drum suitable for hose pipe of size 63 mm and up to all as specified and directed by Engineer-in-Charge.
S&F in repairs 63 mm dia Hose 15 mtr long canvas hose including taking down existing complete with male female coupling complete all as specied and directed by Engineer-in-Charge.
S&F in repairs Fire hyderant stand post 80mm dia GI/MS flanged type 1.5 m height single outlet confirming to IS 908 complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, testing & installation of CI sluice valve flanged of class PN 1.6 ISI marked with gun metal spindal, brass nuts and cast iron wheels jointiting material size 80 mm dia ,in repairs complete all as specified and directed by Engineer-in-Charge.
Supply, fixing & testing of Cast Iron Non Return Valve size 80 mm dia including taking down existing Cast Iron Non Return Valve , complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Fire brigade connection consisting of two way 63 mm dia instaneous complete all as specified and directed by Engineer-in-Charge.
S&F in repairs CI foot valve 100 mm dia both side complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Sprinkle glass tube type complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Sprinkle glass tube upright type complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, testing and commissning in repair of Fire alarm control panel compiling(FACP) 2 loop panel with 99 detectors &99 modules & upto 200 detectors and modules (per each loop) including taking down existing panel complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, testing and commissning of in repair Fire alarm control panel compiling(FACP) 4 loop panel with 99 detectors & 99 modules & upto 200 detectors and modules (per each loop) including taking down existing panel complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, testing and commissning in repair of Addressable type multisensor detector with heat and smoke combination Addressable type multisensor detector with heat and smoke combination as per IS 11360 including taking down existing detector, complete all as per specified and directed by Engineer-in-Charge.
Supply, fixing, testing & commissioning in repair of addressable manual call point/pill station resettable type with base including taking down existing manual call point/pill station complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, testing & commissioning in repairs of control module with base complete all as specified and directed and directed by Engineer-in-Charge.
Supply, fixing, testing & commissioning in repairs of intellegent addressable fault / short circuit Isolator with base complete all as specified and directed by Engineer-in-Charge.
Supply, fixing & testing in repairs of remote Response Indicator complete all as specified and directed by Engineer-in-Charge.
Maintenance and complete servicing of Diesel Engine of KIRLOSKAR Make (Model : 4R1040T) of capacity 83 HP coupled with fire pump of capacity (Discharge capacity 2280 LPM at 70 mtr head) 75 HP consisting of normal repairs if required including replacement of defective / worn out parts such as filters, gaskets, V belts, Engine oil, coolent , rubber hoses, worm drive clamps, nuts & bolts, cleaning of alternator with vacuum cleaner , replacemnt of battery terminals including greasing of bearings etc and testing and commissioning complete after necessary repairs all as specified and directed. Note: Replacement of unserviceable parts shall be measured and paid separately as supply only under respective items of BOQ
Supply only Rubber coupling TC 16 complete all as specified and directed.
Replacement of rubber hose pipe set with clamps suitable complete all as specified and directed.
Supply only oil filter element with O ring suitable complete all as specified and directed.
Supply only Fuel filter element with O ring suitable complete all as specified and directed.
Supply only air filter element complete with outer and inner suitable complete all as specified and directed.
Supply only Engine oil 15 W 40 of 10 Ltrs pack
Supply only coolant for Engine complete all as specified and directed.
Overhauling of self starter of 12 V capacity (Make: LUCAS) including repair/replacement of carbon brushes, bearings, bushes, rewinding of armature with super enameled winding wire and field, varnishing complete all as specified and directed.
Dismantling the Fire centrifugal pump set type DSM 100/36 discharge capacity 2280 LPM at 70 mtr head, 75 HP (Make Kirloskar) , transportation to workshop for carrying out repairs, replacement of unserviceable parts, reassembling, transporting back, fixing the pump in position and testing and commissioning complete with entire satisfaction of Engr-in- Charge. Note: The replacement of unserviceable parts shall be measured and paid separately as "Supply only" under the relevant items.
Supply only CI impeller suitable for pump type DSM 100/36
Supply only gun metal bush suitable for pump type DSM 100/36
Supply only MS Keys suitable for pump type DSM 100/36
Replacement of Ball bearing suitable for pump type DSM 100/36
Replacement of Roller bearing suitable for pump type DSM 100/36
Dismantling the Fire centrifugal pump set type DB 80/26, discharge capacity 2280 LPM at 70 mtr head, 75 HP (Make: Kirloskar) , transportation to workshop for carrying out repairs, replacement of unserviceable parts, reassembling, transporting back, fixing the pump in position and testing and commissioning complete with entire satisfaction of Engr-in- Charge. Note: The replacement of unserviceable parts shall be measured and paid separately as "Supply only" under the relevant items.
Supply only CI impeller suitable for pump type BD 80/26
Supply only gun metal bush suitable for pump type BD 80/26
Supply only MS Keys suitable for pump type BD 80/26
Replacement of Ball bearing suitable for pump type BD 80/26
Replacement of roller bearing suitable for pump type BD 80/26
Dissmantling the Fire jockey pump set 10 HP to 12,5 HP (Make: Kirloskar) , transportation to workshop for carrying out repairs, replacement of unserviceable parts, reassembling, transporting back, fixing the pump in position and testing and commissioning complete with the entire satisfaction of Engr-in- Charge. Note: The replacement of unserviceable parts shall be measured and paid separately as "Supply only" under the relevant items.
Supply only CI impeller suitable for jockey pump
Supply only gun metal bush suitable for jockey pump
Supply only MS Keys suitable for jockey pump
Replacement of Ball bearing suitable for jockey pump
Replacement of roller bearing suitable for jockey pump
S&F in repair Battery 12V, 7 AH dry type complete all as specified and directed.
S&F in repairs Addressable electronic sounder cum strobe complete all as specified and directed.
Supply , fixing & testing PVC insulated HFFR single core multi stranded copper counductor cable 1.5 sqmm, 1.1KV complete all as specified and directed.
Supply , fixing & testing pressure switches KP35 complete complete all as specified and directed.
Supply , fixing & testing pressure switches KP 36 complete complete all as specified and directed.
Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 complete all as specified and directed.
Supply and fix hose reel of 20 mm dia and 30 meter length conforming to IS 5132 complete all as specified and directed.
S & F Battery 12V 180 AH lead acid type Heavy dudy of 36 month warrenty complete all as specified and directed.
S & F Pressure gauge 4"dial 0-21 kgs rating complete all as specified and directed.
S & F Pressure gauge 8"dial 0-21 kgs rating complete all as specified and directed.
M/S GODARA CONSTRUCTION CO.
S S Infra Tech
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .