| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | ₹20.9 L Quoted ₹21.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.3 L+₹41,866.67 (1.91%)Rejected-Finance 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | ₹22.3 L+₹41,866.67 (1.91%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹25.3 L+₹3.4 L (15.5%)Rejected-Finance | ₹25.3 L+₹3.4 L (15.5%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹27.9 L+₹6.0 L (27.4%)Rejected-Finance B 17 SHRIRAM INDUSTRIAL ESTATE G D AMBEKAR ROAD WADALA MUMBAI CITY MAHARASHTRA 400031 | MUMBAI | MAHARASHTRA | 400031 | ₹27.9 L+₹6.0 L (27.4%) | L4 | Rejected-Finance BEING L4 |
| 5 | L5₹31.7 L+₹9.8 L (44.8%)Rejected-Finance | ₹31.7 L+₹9.8 L (44.8%) | L5 | Rejected-Finance BEING L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
30 Apr 2022, 6:00 pmClosed
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR AND MAINTENANCE LT EXTERNAL ELECTRIC SUPPLY AND DISTRIBUTION SYSTEM AND ALLIED WORKS AT SITE P AF STATION THANE AND REPAIR/ MAINT TO LT PANEL,APFC PANELS,FEEDER PILLAR BOX AND ALLIED WORKS AT SITE P UNDER GE AF THANE
2022_MES_516101_1
8190/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹50,000
Yes
24 May 2022
1 Apr 2022
2 May 2022
1 Apr 2022
30 Apr 2022
19 Apr 2022
1 Apr 2022 - 19 Apr 2022
Amount
Taking out old unservicable LT UG cable of 4/3.5 core x 10 Sqmm to 25 Sqmm size and shall be deposited to place where as directed by Engr In Charge
Taking out old unservicable LT UG cable of 3.5 core x 35Sqmm to 150 Sqmm size and shall be deposited to place where as directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3½core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3½core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 4 core.Make: Polycab/Havells/Paragon
Excavation in trenches, n exc 1.5 mtr wide and n,exc 1.5 mtr in depth; for foundation etc. or for shafts, wells cesspit, manholes, pier holes,etc n,exc 10 Sqm on plan and n exc 1.5mtr in depth and getting out as in Soft/loose Soil,complete all as specified and directed by Engg-in-Charge.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, in Soft/Loose Soil, ,complete all as specified and directed by Engg-in-Charge.
Removing excavated material n exc. 50m in soil and depositing where directed at a level n exc. 1.5 m above the starting point , including loading, unloading and stacking at the destination , complete all as specified and directed by Engr-in-charge.
M&L for Sand cushioning for UG cable protection/ducts, consolidated sand compacted with clean dry sand , complete all as specified and directed by Engr-in-charge.
M & L for Boring of road crossing in any kind of soil/rock strata , complete all as specified and directed by Engr-in-charge.
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified.
Supply and laying un reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and as directed.
Supply & laying GI pipe light graded of size 50mm dia in trenches and fixing on wall / pole with help of suitable size MS clamp for cable protection with all fitting; complete all as specified and directed by Engr-in-charge.
M & L for earthing complete with coper earth plate electrode 600 x 600 x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal ground level and connected to earth test point by means of GI strip 25X4 mm all as specified and show in electric plate No 3 of MES SSR Part -I 2009 Including earthwork, PCC Chamber CI cover,protection and watering pipe, funnel,mesh etc all as reuired at site and all as directed note (i)7.5 M Copper strip in deemed to be cluded in quoted rates beyond 7.5 RM shall be meaured and paid separately (2) Earth resistance of earth pit should be less than 1.00 Ohms.on testing after completion if teh desired earth resistance in not obtained the earthing will be redone at no extra cost (3) Rate quoted by the tenderer is deemed of include salt & charcoal upto & above 450 mm top of copper plate
S&F GI pipe light grade of size 40mm dia fixing on pole/laid in trenches complete all as specified and directed by Engr-in-charge.
S&F GI pipe light grade of size 80mm dia fixing on pole/laid in trenches complete all as specified and directed by Engr-in-charge.
S&F GI pipe light grade of size 15 mm dia fixing on pole/laid in trenches complete all as specified and directed by Engr-in-charge.
Taking down Defective street light of LED of Capacity 25/30/60/90 W, flood light and bldg security light fitting of any type from their existing postion ie. Poles and bldg and re-fixing the same after carried out repairs ie. replecement of LED driver and SPD,PVC Wire etc all as specified and directed by Engr In Chrarge. Note: LED Driver,SPD and 3 core cable for replacement shall be measured and paid separatly under relevent item of Sch 'A' as supply only.
Supply only Surge protection device (SPD) of capacity as mentioned below, with phase ,neutral and earth wire in incoming and out going both sides, complete all as specified and directed by Engg.in.Charge. Make: Bajaj/Havells/Crompton.Of the following Capacity:-
Of capacity 8 KV
Of capacity 5 KV
Supply only LED driver for LED Street light Fitiing ,of the following,complete all as specified and directed by Engg-in-Charge.Make: Bajaj/Havells/Crompton
for 25 Watt
for 30 Watt
for 60 Watt
for 90 Watt
Supply, fixing and testing LED street light fitting including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report ,complete all as specified and directed by Engg-in-Charge .Make: Bajaj /Havells/Wipro. Of the following:-
For 25 Watt
For 60 Watt
Supply, fixing and testing LED Flood light fitting in repair/replacement of existing high mast lights including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report ,complete all as specified and directed by Engg-in-Charge .Make: Bajaj /Havells/Wipro. Of the following:-
Of 120 Watt
Of 80 Watt
M&L for connecting 1100 volt grade heavy duty cable PVC insulated copper conductor, served with inner sheathing of PVC tap and over all PVC sheathed in service connection for street light from FRP junction box to street light of size 3 core 1.5 Sqmm ,complete all as specified and directed by Engg-in-Charge. Make: Paragon/HPL/Havells
M&L for Cutting/Trimming of tree branched not exc 10 cm girth touching /approaching the LT/HT Over head line (having each span of 45 mtr) upto 3 mtr width on each side with cutting machine or manually to clear the LT/HT line including disposal of trimmed branches 100 mtrs away inside the cantonment area & cleaning site ,complete all as specified and directed by Engg-in-Charge. ( Note : All tools and plant required for cutting shall included in quoted rates)
Providing and deployement of manpower for Cleaning and removing vegetation from electric substation and surrounding area with the helper of labour upto proper satifaction of Engineer-in-Charge complete all as specified and as directed. (Note -1. Each Jobs includes cleaning the area of 3 Nos of Substation & 2 DG sets Installation Approx total 1500 Sqm Area 2. Necessary tools, plant & safety equipments shall be arranged by the contractor in his own cost.)
M&L for hardcore of broken stone boulder, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat , complete all as specified and directed by Engr-in-Charge.of the following sizes:-
For flat of size 6 Sqmm
For flat of size 10 Sqmm
Supply, perform, testing, commissioning of LT cable straight through joint kit heat shrinkable of 4 core x 10/16/25 Sqmm size , complete all as specified and directed by Engg-in-Charge. Make : Denson Part No : XSS-02/Raychem / M-Seal/ Birla-3M
Supply, perform, testing, commissioning of LT cable straight through joint kit heat shrinkable of 3.5 core x 35/50 Sqmm , complete all as specified and directed by Engg-in-Charge. Make : Denson Part No : XSS-02/Raychem / M-Seal/ Birla-3M
Supply, perform, testing, commissioning of LT cable End through joint kit heat shrinkable of 3.5 core x 50/70 Sqmm size complete all as specified. Make : Denson Part No : XSS-02 /Raychem / M-Seal/ Birla-3M
Supply and fixing HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 32 Amp 4 way heavy duty terminal block with 10Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole, including taking down existing , complete all as specified and directed by Engg-in-Charge.
Supply & Fixing LED Bollard light 9/10 watts with opal acrylic diffuser and IP-65 protection , pressure die cast housing with PC diffuser, suitable for garden and pathway complete with internal connection including suitable size of stand for LED garden light of 9/10 Watts capacity , complete all as specified and directed by Engg-in-Charge. Make: Bajaj cat part No. BGBOM 650 9W LED/Halonix Cat Part No.HLOB-03-10 CW/Crompton Cat part No.LBLA2-10-CDL Note : Warranty and test certificate of LED light fittings to be produced as and when asked by Engr-in-charge.
Supply and fixing MCB DB single door vertical type for 2 way 240 volt SPN confirming to IP-45 protection and IS 13032 , complete all as specified and directed by Engg-in-Charge.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate, in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed by Engr-in-charge.
M&L for Plain Cement concrete in foundations, filling and mass concrete , type D-2 (1:4:8) using 40mm graded stone aggregate as in foundations, filling & mass concrete, complete all as specified and directed by Engr-in-Charge.
Disconnecting of LT supply and opening bus bar chamber / Cable box chamber of outdoor/ indoor LT kiosks / Panel , removing of burnt out lugs, MCB / isolators of any capcity/ size and cleaning of bus bar with CTC solutions, insulating the bus bar by taping with RYB colours, necessary nuts bolts of existing size and refixing after rapairs,complete all as specified and directed by Engineer in charge. (Note: Aluminium lugs of size and MCCB as mentioned below shall be measured and paid separately under relevent item of Sch A as supply only.)
Supply only aluminum lugs suitable for Cable of the following sizes:- Make : Denson/Raychem / M-Seal/ Birla-3M
Of size 10 Sqmm to 16 Sqmm
Of size 25 Sqmm.
Of size 35 Sqmm
Of size 50 Sqmm.
Of size 70 Sqmm.
Of size 95 Sqmm.
Of size 120 Sqmm.
Of size 150 Sqmm.
Supply only MCCB 4 pole 63 A , 415 V, 50Hz having breaking capacity 16 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engr-in-Charge.Make: Indoasian /Havells/HPL
Supply only MCCB 4 pole 100 A , 415 V, 50Hz having breaking capacity 16 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engr-in-Charge.Make: Indoasian/Havells/HPL
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as spd and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts,ashers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
Supply only MCCB 4 pole 160 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engr-in-Charge.Make: Indoasian Cat No.X220M4T/Havells/HPL
Supply only MCCB 4 pole 200 A , 415 V, 50Hz having breaking capacity 36 KA with adjustable thermal & magnetic setting , complete all as specified and directed by Engr-in-Charge.Make: Indoasian Cat No.X250H4T/Havells/HPL
Supply only MCCB 4 pole 250 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting , complete all as specified and directed by Engr-in-Charge .Make: Indoasian Cat No.N3200M4P/Havells/HPL
Inspection/checking & testing after repair of APFC panel 3 Phase,440 voltage 50Hz AC supply system to improve power factor 0.80 to 0.99 automatic step wise switched capacitor panel to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,contactors,MCB's.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMF panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage. (Notes :-This items includes the cost of cleaning & rewiring of panel. Spare parts required shall be measured and paid for separately under respective items as supply only)
Supply only in replacement of AIPFC microprocessor based relay 8 stage PFC controller ,230 volts complete all as specified and directed by Engineer-in-Charge. Make- L&T/EPCOS/Siemens
Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 10 KVAR complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 15 KVAR complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of capacitor duty contactor 3 phase suitable upto 20 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of capacitor duty contactor 3 phase suitable upto 16 KVAR capacity duty contactor 1NO1NC 240 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in repair of MCB 6 to 32 Amps, 3 Pole,10 KA coplete all as specified and directed by Enginner-in-Charge.
Supply only in replacement of current transformer of ratio 200/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of current transformer of ratio 100/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement indictor lamp assembly LED type complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing Start/stop push button complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement of digital type voltmeter 96 mm x96 mm, of range 0-500 Volts,Class-I complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement of digital type ammeter 96 mm x96 mm, of range 0-200 Amps,Single Phase complete all as specified and as directed by Engineer-in-Charge.
M& L for preparation of existing painted surface of panel board/feeder pillar box (inddor/outdoor type), area not exeeding 10 Square metre each and applying one coat of synthetic enamel paint after preparation of surfaces on external and internal surfaces of approved tint by using spray machine (not exceeding of height 5 cm each) including welding of broken panel, tightening electric connection of switch gear and cleaning of vegetation all around the panels upto one meter from all sides complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement heavy duty TPN bus bar chamber 100 Amps,4 way fixed with hinges and locking arrangments for 4 Nos incoming/outgoing connection each bus bar fixed on wall complete all as specified and directed by Engineer-in-Charge.
M&L for fixing MS sheet 2mm thick to existing LT panels / feeder pillar box including necessary straightening /correcting the distorted parts, cuttings, welding / riveting,drilling bend to shape as required, welding of hinges, sliding door bolts, locking arrangement, nut, bolts, washers etc and appying two coats of synthetic enamedled paint over a coat of red oxide primer to match with the existing surfaces comlepte including butt hinges sliding door bolts and taping , thimbling disconnecting all incoming and outgoing complete all as specified and as directed by Engineer-in-charge. Note :- Rate of butt hinges and sliding door bolts shall be deemed to be included in quoted rate.
Material and labour for carrying out repair/maintenance through manufacturer or authorised service center of Auto servo control voltage stabilizer 300KVA capacity located at HQ area . (i)Opening of stabilizer and maintanance of spare parts,fixing of new/repaired parts after repair in place of defective parts,repairing the defective control system etc and assembling complet all as specified and directed. (ii) Testing of stabilizer after repair on existing location to desired and rated output. Note:- All defective parts maint and cost of labour for maint is deem too be included in unit rate .
EVEREST POWER CONTROL ENGINEERS
Vinod Enterprises
Urja Techniques India Pvt. Ltd.
Safe Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .