Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | ₹34.0 L Quoted ₹34.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹37.2 LRejected-Finance | ₹37.2 L | L2 | Rejected-Finance other than L1 |
| 3 | L3₹43.1 LRejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹43.1 L | L3 | Rejected-Finance other than L1 |
| 4 | L4₹44.4 LRejected-Finance | ₹44.4 L | L4 | Rejected-Finance other than L1 |
| Sl No | Description | Qty | Unit | shiva enterprises L3 | M/S MG GROUP L4 | Laxmi traders L2 | SURESH KUMAR SHARMA & CO L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed by Engr In Charge. | 22.08 | Cum | 111 ₹2,450.88 | 200 ₹4,416 | 50 ₹1,104 | 500 ₹11,040 |
| 2.00 | M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 complete all as specified and directed. | 16 | Cum | 4,999 ₹79,984 | 3,800 ₹60,800 | 3,500 ₹56,000 | 3,800 ₹60,800 |
| 3.00 | M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. | 12 | Sqm | 555 ₹6,660 | 1,000 ₹12,000 | 450 ₹5,400 | 750 ₹9,000 |
| 4.00 | Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc and removing the debries outside the MOD land complete all as specified and as directed by Engr -in - Charge. | 577.5 | Sqm | 11 ₹6,352.50 | 5 ₹2,887.50 | 50 ₹28,875 | 20 ₹11,550 |
| 5.00 | M&L for rendering 10 mm thick in CM 1: 6 on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge. | 250 | Sqm | 201 ₹50,250 | 150 ₹37,500 | 160 ₹40,000 | 150 ₹37,500 |
| 6.00 | M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement upto four storey complete all as specified and directed. | 256 | Sqm | 201 ₹51,456 | 150 ₹38,400 | 190 ₹48,640 | 220 ₹56,320 |
| 7.00 | M & L rendering 5 mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement complete all as specified and directed. | 103 | Sqm | 166 ₹17,098 | 150 ₹15,450 | 110 ₹11,330 | 180 ₹18,540 |
| 8.00 | M&L for preparing surfaces of new plaster on walls and applying exterior two or more coats of APEX/WEATHER over 1 mm putty including priming coat of exterior primer complete all as specified and directed by Engineer-in-charge. | 221 | Sqm | 55 ₹12,155 | 70 ₹15,470 | 90 ₹19,890 | 60 ₹13,260 |
| 9.00 | M&L for preparation of new plastered surfaces of walls/ceiling and applying two coats of distemper oil emulsion over a coat of alkali resistant primer incl 1 mm thick elastomeric wall care putty on walls complete and specified and as directed. | 322 | Sqm | 44 ₹14,168 | 35 ₹11,270 | 50 ₹16,100 | 40 ₹12,880 |
| 10.00 | M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty, complete all as specified and directed by Engr-in-Charge. | 140 | Sqm | 33 ₹4,620 | 35 ₹4,900 | 35 ₹4,900 | 40 ₹5,600 |
Updated dates
Tender Value
₹48.5 L
EMD Value
₹96,940
Closing Date
7 Feb 2026, 6:00 pmClosed
GE (AF) SUBROTO PARK
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2026_MES_747598_1
GE/SP/TOKEN-70/2025-26
Open Tender
Miscellaneous Works
120 days
GE (AF) SUBROTO PARK
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) SUBROTO PARK
₹96,940
Yes
18 May 2026
7 Jan 2026
10 Feb 2026
7 Jan 2026
7 Feb 2026
26 Jan 2026
Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed by Engr In Charge.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 complete all as specified and directed.
M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc and removing the debries outside the MOD land complete all as specified and as directed by Engr -in - Charge.
M&L for rendering 10 mm thick in CM 1: 6 on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement upto four storey complete all as specified and directed.
M & L rendering 5 mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement complete all as specified and directed.
M&L for preparing surfaces of new plaster on walls and applying exterior two or more coats of APEX/WEATHER over 1 mm putty including priming coat of exterior primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls/ceiling and applying two coats of distemper oil emulsion over a coat of alkali resistant primer incl 1 mm thick elastomeric wall care putty on walls complete and specified and as directed.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty, complete all as specified and directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr In Charge.
S & F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders;Chajj, framed balusters; walk ways; railings; cooler stand,stair, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engr In Charge.
S & F steel work in tubular trussesand ,column including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 1979 grade St-240
S & F Mild Steel plates (plain or chequred ) channels, square cut to notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings. complete all as specified and directed.
S & F moulded pre-painted galvanume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F moulded pre-painted galvanume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in eaves sheeting /cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for prepation of old /New painted wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel Paint, complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out returning , filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing surplus soil to a distance n.exc 50 m and making good in hard/dense soil complete all as specified and directed
M & L PCC (1:4:8) type D-2 ( using 40mm crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed
M & L PCC (1:3:6) type C-2 ( using 20mm crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed.
All as per item No 23 here in before but not exc 1.5 Sqm .
S&F for size 105x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, hold fast, lock strike plate, etc complete all as specified and directed
S&F for size 125 x 60 mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, hold fast, lock strike plate, etc. complete all as specified and directed
M & L for cement concrete type C1, 1:3:6 (using 20 mm graded stone aggregate) in door and windows frames, any size, single or double rebated, including ar- rangement for fixing of hinges and fixtures as required complete all as specified and directed by Engr In Charge.
S&F for 35 mm thick II nd Class hardwood Glazed and skeleton shutters, open rebated and with prepared to receive wire cloth (gauze), etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by Engr In Charge.
S & F 30 mm factory made plain framed, Flush shutters, solid core construction, with block board core and plywood face panels, commercial particle board with type on both faces.complete all as specified and directed.
S&F factory made PVC door frame (Choukhat) of the size 50x47 mm with a wall thickness of 5mm (±0.25), made out of extruded 5mm (±0.25) thick PVC Sheet of Density 600 Kg /Cbm Manufactured by an ISO-9001 - 2015 certified Company , All three frame lengths reinforced with 19mmx19mm M.S. square tube cut at two corners and joined with 2nos. of 150mm long brackets of 15mmx15mm M.S. square tube or joint by fusion heat welding. The door frame shall be fixed to the wall using 8/100mm long M.S.Screws through the frame by using PVC fasteners. A minimum of 4nos of screws to be provided for each vertical member & minimum 2nos of horizontal member etc. complete as per manufacturers specification and directed.
S&F factory made (28-30) MM thick solid PVC door shutter consisting of frame made out of M.S tubes of size 19 X 19mm for style & 15x15mm for the top and bottom rails, M.S frame shall have a coat of metal primer of approved make and manufacture . M.S.frame shall be covered with heat moulded PVC ‘C’ channel made from 5mm (±0.25) thick sheet of Density 600 Kg /Cbm manufactured by an ISO- 9001-2015 certified company, 50mm width to form styles and 5mm (±0.25) thick and 75 mm wide PVC sheet for the top rail, lock rail and bottom rail on either side of the panel.Complete as per direction of Engineer-in-Charge.
S&F 150mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed complete and specified and directed by engr-in -charge.
S&F 150mm long aluminium handle cast type polished bright complete and specified and directed by engr-in -charge.
S&F 100 mm long butt hinges medium weight, stainless steel, and fixed complete and specified and directed.
S&F for 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed
S & F in repair 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and directed
S & F in repair 140mm long floor door stopper of Almn alloy body and tongue with hard drawn steel spring complete all as specified and directed
S&F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed
S&F windows/ventilators section of frame 72 X 55 fixed to wall or concrete surface with ms hold fast (30 x 5 section) 150 mm long made of galvanised steel powder coated and section of shutter 47 X 20 mm mulion section 72 X 50 mm (Base steel as per IS 513 "D" quality galvanised as per IS 277 with zinc of 120 gms/ Sqm ) glazed or guaged and wire guage shutter prepare to recieve wire mess to the shutters ( Double door shutter) with total coated thickness of 0.60 mm including powder coated grill/guard bars made of surface bars 10 mm dia at 100 c/c horizontal spacing fixed in ms flat frame ( 30 x 5 mm ) fixed to windwods frames with screws incl 4 to 5 mm thick sheet glass, 0.36 mm stainless steel wire cloth with 1.40 mm aparture neccessary fittings and all builders hard ware such as handles ,tower bolts, and stays and cooler opening shall be provided with double side shutter with grill and design of window shall be approved by Engr-in-Charge etc. complete all as specified and shown in Drg No : CEAF/STD-191/2014 Sheet No 1/2 and 2/2 dated 11-12-2014 including taking down existing window/vetilator and making good .
Demolition of reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas, RCC Jali,slab, Parapit wall and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-Charge.
M & L Reinforced cement concrete M-25 (using 20mm graded stone aggregate) as in chajjas,roof and the like complete all as specified and directed.
M&L RCC M-25 (using 20 mm graded stone aggregate) as in slab,shelves etc complete all as specified and directed
M & L formwork to chullah hoods, slab, trough and similar items including edges finished rough surfaces of concrete upto four storey complete all as specified and directed
S& F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia upto four storey complete all as specified and directed
All as per item No 44 above but 6 to 8mm dia, as in stirrups, spacers and binders complete all as specified and directed by Engr In Charge.
Supply only liquid water proofing compound only complete all as specified and directed by Engr In Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises and disposed from outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete all as specified and directed
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not xceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) over 100mm thick plain cement concrete, type D-2, 1:4:8 (using 40mm graded stone aggregate) complete all as specified and directed
M&L Glazed ceramic coloured tiles in vertical surface 300X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl back plaster 10 mm thick in cm 1:4 complete all as specified and directed.
All as per item No 48 but as on vertical surface of wall such as skirting/dado incl 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and directed by Engr In Charge.
Demolition of concrete surfaces in ground floor and paving n.exc. 15cm thickness (below or above ground level) complete all as specified and directed
M & L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in Plinth Protection and hard standing using 40 mm stone including making joints & filling with sand bitumen mastic complete all as specified and directed.
M & L for complete removal of existing roof treatment (Mud puska, Cement Tiles, bricks or Old APP Roof treatment and vegitation from root) including bedding layer in cement mortar/Mud and disposed from outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope.All overlaps shall be bonded with bitumen primer and levelled by the heating the overlaps with butane torch. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (c) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. Note:- This treatement shall be done by the approved authorized applicators and guarantee of treatement shall be minimum 10 years complete all as specified and directed by Engr In Charge.
M&L for providing cement concrete type B1 1:2:4 using 20mm graded aggregate in roof kerbs or mud stops,padding, rounded or chamfered on edges without using extra cement complete all as specified and directed by Engr In Charge.
M&L for 10 mm thick cement mortar 1:4 on fair faces of brick or concrete surfaces with integrlal water proofing compound as per manufacturers instructions complete all as directed and specified. Note : WPC shall be paid and measured seperately under relavent item
M&L for cement concrete tiles 20cmx20cmx18-20mm thick, with grey cement and no pigment; machine pressed; set, jointed and pointed in net cement slurry in floor/roof slab and cut and polished incl over 15mm thick screed bed in cement mortar (1:4) including demolition of tiles and removing of all material out side of MOD land complete all as specified and directed
Taking down steel tubing or removing from site of 15mm bore pipe all as specified and directed by Engineer-in-charge.
All as per item No 58 here in before but 20mm bore.
S&F for 15mm bore steel water tubing medium grade , galvanized ISI marked with all concealed fittings fixed to wall & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
All as per item No 60 here in before but 20mm bore
Dismantling water tanks exc 250 but not exc 500 ltrs capasity and removing to store complete all as specified and directed by Engr In Charge.
S&F Rotational moulded polyethylene 500 Ltr water storage tanks white colour as per IS (cylindrical vertical with closed top) hoisted and fixed in position including necessary fittings complete all as specified and as directed by Engr-in-Charge.
S &F for 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe orr brass errule and fixed complete all as specified and directed by Engr In Charge.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engr In Charge.
S&F for PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc complete all as specified and directed by Engr In Charge.
All as per item No 66 here in before But 75 mm dia..
S&F for PVC SWR bends 110 mm complete all as specified and directed by Engr In Charge.
S&F PVC SWR bends 75 mm complete all as specified and directed by Engr In Charge.
S&F for PVC SWR vent cowl of size 75 mm complete all as specified and directed by Engr In Charge.
Supplying and fixing in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, including fixing bolts, flushing cistern and flush pipe) complete all as specified.
S&F in repair PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia complete all as specified and directed by Engr In Charge.
S & F in repairs for 125mm dia Steelness steel grating doom with waste hole for waste pipe ( minimum weight 40 gram) complete all as specified and directed by Engr In Charge.
S&F in repair Gun-metal, globe or gate valves, bore dia of pipe 20mmwith iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-In-Charge.
S & F in repairs 15mm CP bib tap fancy type copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe etc complete all as specified and directed by Engr In Charge.
M&L in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cemen complete all as specified and directed by Engr In Charge.
M&L for removal of old malba , (debris) incluiding old broken bricks , rcc debris and all using trolley tractor , loading trolley to full capacity and leveling the surface of land and disposing debris outside MOD land as per directed by engr-in-charge. Note : Capacity of per load not less than 16 Cum
S&F in repairs vitreous china wash hand basin of size 550mm x 400mm white, flat back including angle iron brackets with two coats of synthetic enamel paints including PVC waste pipe of 32mm dia of suitable length, PVC connection of 15mm dia & 450mm long with PTMT nuts, and 32mm dia brass waste fitting complete all as specified and directed
M & L in repairs for 15 mm dia Fancy type Chromium plated Angle valves, cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
S&F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints complete all as specified and directed
S&F in repairs Brass CP tubular Towel rail , 20 mm dia, D Type 600mm long between flanges brass chromium plated with screws and cleats, (Minimum weight 190 gms) complete all as specified and directed
S&F of glass shelf consisting of 5.5 mm thick sheets glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engr In Charge.
S & F in repair 25 mm dia Stainless steel coated curtain rod including all necessary fixing arrangement like clamps, end to end bracket per meter complete all as specified and directed by Engr In Charge.
S & F repair CP towel ring complete all as specified and directed.
S & F in repair brass CP hand shower( health faucet ) with 1.0 m long easy flex tube in chrome finish and wall hock complete all as specified and directed.
S&F in repairs brass CP cloth hanging hooks set of six hooks complete all as specified and as directed
S &F M S Work in post and struts in fencing inc cutting top to shape ,drilling holes,notching for wire etc,flat iron fillets inc all necessary drilling,bolting or rivetting and similar work cofirming to Fe -290 Gde E-165
Supply only Chain link MS galvanised fencing, any size or type weighting complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long dia of shank 5 to 10 mm
S&F for mild steel round bars, 10 mm dia and over cut to length bent to shape required including cranking binding spirally, hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality conforming to Fe-410W Gde E-250 complete all as specified and directed.
Dismantling to Stone slabs and tiles of any description or thickness in floors, aprons etc, and inclu removal upto 20 km from premises (defence land), complete all as specified and directed
M&L 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed
M&L for rubber moulded glossy finished colour Chequered cement concrete tiles with white cement and pigment 30cm x 30cm x 22-25mm thick, set, jointed and pointed in neat cement slurry incl 15mm thick Screed bed or bedding layer of cement mortar 1:4 for for laying tiles complete all as specified and directed
M & L for Machine pressed precast conctete colour interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment laid and bedded on sand cushioning complete all as specified and directed
M&L for Sand filling under floors or in foundations including watering and consolidation all as specified and directed.
M & L for providing cement concrete (1:2:4) (20 mm graded stone aggregate) as in copping/ roof kerbs or mud stops, rounded or chamferd edges, including form work complete all as specified and directed
Complete removal of existing treatment on walls and applying two coat of approved shade of oil emulsion distemper over a coat of alkali resistant primer with (1to2) mm thick elastomeric wall care putty on walls complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered or unplastered surface and applying three coat of white wash on ceiling incl 1mm thick wall care putty on walls complete all as specified and directed by Engr-In-Charge.
M&L Vitrified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed
All as per item No 101 here in before but as on vertical surface of wall such as skirting/dado including 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and as directed
S&F false ceiling with Semi perforated 12mm thick acoustical false ceiling, (fire retardant and sound absorbent) micro regular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595 mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99% NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 475 (Part 4) -1970 and light code description unit rate No 429 Sub Head : 26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanised @ 120 grams per sqm including both sides) comprising of maint -T runners of size 15x32mm of length 300mm, cross -T of size 15x32 of length 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @80 grams per sqmm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-Shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on perimeter wall /partition with the help of plastic rawl plugs at 450mm centre to canter and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of Engr- in -charge
S&F factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note : The unit rate quoated by contractor include cost of glass and includes all other connected accessories like film or tinted glass. Net opening will be meausered for payment purpose) all as specified and directed by enge - in - charge.
S&F aluminium powder coated any colour (minimum thickness of powder coating 50 micron) for doors, windows, partician, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium powder coated an (minimum thickness of powder coating 50 micron) as in window and ventilator shutters, both side openable , aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber packing, anodised aluminum snap beading screws etc complete all as s&d by Engr-In-Charge.
S&F in repair aluminium deco grills confirming to DG-104 grade all as specified and directed by Engr-In-Charge.
S & F aluminium extruded section door closer hydraulically operated designation No-03, universal type, suitable for door shutters of 851 to 1000mm width and of weight of 61 to 80 Kg complete all as specified and directed by Engr In Charge.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
All as per item No 114 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size. Note: (a) one circuit with max 8 points (not more than 2x 6 A sochet in one circuit)
All as per item No 114 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size. Note:(a) socket outlet 6 amp only , one circuit with max 4 points with 2.5 sqmm circuit wire, otherwise only one point in each circuit with 1.5 sqmm wire.
All as per item No 114 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge.Note: (a) only one point in each circuit .
S&F switch piano 5 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet flush type 5 pin 6 amps suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F switch piano 16 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 5 pin 16 amps flush type suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Taking down including disconnecting the electric connection of exhaust fan and dismantling blades,greasing and painting the whole assembly including marking MES No complete all as specified and directed
Fixing only Exhaust fan received from item No 110 above and connecting up including fastner and provision of suitable size of copper cable from connector of fans to ceiling rose complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
M & L for in replacement submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified. NOTE: 3 Runs of 6.0 Sqmm single core and one run of 20mm conduit included in deemed rate.
S&F of load line vertical distribution board 'A' frame made out of CRCA sheet 2mm,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 125 Amps =01 No MCCB for outgoing comlete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 16 KA complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Make - Havells or equivalent to Standard/Asian (Note :- MCB shall be measured and paid seperately.)
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Make - Havells or equivalent to Standard/Asian (Note :- MCB shall be measured and paid seperately.)
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
Supply and fixing MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts,40 C Curve capacity all as specified and directed by engineer-in-charge.
S&F MCB SP 40 Amps 10 KA, 240 volt 'c' Series all as specified and directed by engineer-in-charge.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including 4 mm dia as earth lead wire by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth and getting out in soft/loose soil for laying cables etc complete all as specified and as directed by the Engineer - in - Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
M&L for sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as specified and directed by Engineer-in-Charge
Supplying and laying unreinforced precast cement concrete cable covers, Class LV, Type - 1, Flat, size 250mm X 150mm X 40mm in trenches for cable protection, embossed with " LV ELECTRIC" on the top surface complete all as specified and as directed by the Engineer - in - Charge.
Supplying, laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 120 Sqmm x 3.5 core complete all as specified and directed.
Supply, Installation, testing and commissioning of indoor type 40 KVA Isolation Transformer S.I.T.C of Isolation transformer , Three phase ,50 Hz , indoor , Copper wound , oil cooled , class of insulation A ,metallic body duly powder coated designed for input Voltage range 415+-5% and output voltage range 415+-5% ,Ratio 1:1 , Vector Group :Dyn 11, Delta- star with first filling of transformer oil of requisite dielectric strength up to level , efficiency more than 95 % , separate neutral bushing shall be brought out for earthing Potential difference between neutral to earth less than one volt with all standard fittings like digital temperature meter , adequate number of cooling radiators , lifting hooks one set , Earthing terminal two nos complete . Testing as per BIS 9815 and 2026
S&F in sheet metal enclosure, duly powder coated with MCCB 200 Amps TPN 415 volts 3 phase 50 HZ, Ics=100%Icu, breaking capacity 25 KA complete all as specified and directed.
Supply and fixing cable tray made out of perforated 16 SWG GI cable tray of size 500mm width and 50mm height complete all as specified and directed.
M&L for cutting of Hardstanding/road by mannual method upto 600mm deep for inserting HDPE pipe 150mm dia for cable protection complete and making good disturbed surface as existing with pre mix ready made repair patching compound complete all as specified and directed.
M&L for conductive concrete Earth Grid of multiple interconnected Earth Electrodes to achieve the earth resistance value of less than <5 Ohm. The excavation is to be carried out in any type of soil including hard rock. The approx specification are as under:- (i) Earth Electrodes: Metal conductor - Copper bonded MS rod dia 17,2 mm (+-5mm) , Length 2.25 meter with conductive concrete including provision of bore 65 mm dia, 2.25 meter length of earth electrode. (ii) All earth electrodes (min two Nos) should be installed to achieved the desired result. (iii) Interconnected strip : All the multiple Earth Electrodes will be horizontally interconnected with metal conductor - Copper strip flat size : 25mm x 3 mm & conductive concrete embedding size : 60 Sqmm. (iv) Test Link: Test links- Copper stripflat size: 40 mm x 6 mm x 200 mm shall be provided, at any one of the multiple Earth Electrodes of the grid for connection between earth grid pit and application. (v) Pit Cover: RCC pit cover & frame shall be provided at all Earth Electrode (with test links)
Supply & fixing aluminium strip 20x3.15 mm with saddles and fixing screws etc.for roof conductors and down conductors having insulators at one meter interval complete all as specified and directed.
Taking down of light fittings of any wattage complete all as specified and directed
Taking down ceiling fan, sealing cable end,dismantling blades ,removing fan and blades , switches and fan regulators to store for re-fixing complete all as specified and directed.
All as per item No 150 above but one fan point controlled by one switch
All as per item No 150 above but with copper conductor cable FLRS 2.5 sqmm for one 3 pin socket outlet,15 Amps concealed and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
S&F Modular switch 1 way 16A, 1 module suitable for 240 volt AC complete all as specified and directed.
S&F Modular socket 6/16A, 2/3 pin combined 2 module, suitable for 240 volt AC complete all as specified and directed.
S&F electronic modular fan regulaor rotary flush type 120 watt, 240 volt complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Hanging only ceiling fan connecting up with necessary clamps , nuts , bolts and required length of rod including cutting of existing false ceiling board complete all as specified and directed
M&L sub main wiring with two single core PVC insulated unsheathed cable 10.00 Sqmm (Nominal area) with multistranded FRLS copper conductor cable, 1100 volts grade drawn through and including PVC casing & caping of size not less than 25mm dia with fixing accessories and earth continuity conductor of single core PVC insulated, unsheathed cable 10.00 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade and making good disturbed surfaces complete all as specified and directed. Note - (i) Two run of wiring cable, one run of earth wire and one run of PVC casing & caping shall be measured as one unit.
M&L sub main wiring with two single core PVC insulated unsheathed cable 6.00 Sqmm (Nominal area) with multistranded FRLS copper conductor cable, 1100 volts grade drawn through and including PVC casing & caping of size not less than 25mm dia with fixing accessories and earth continuity conductor of single core PVC insulated, unsheathed cable 6.00 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade and making good disturbed surfaces complete all as specified and directed. Note - (i) Two run of wiring cable, one run of earth wire and one run of PVC casing & caping shall be measured as one unit.
Supply and fixing of modular socket and plug complete with one single pole MCB of 20 Amps rating complete all as specified and directed.
S&F Moulded case circuit breaker (MCCBs) Triple pole and Nuetral, 415 Volts, 200Amps, 25 KA with current carrying capacity in the DB complete all as specified and directed.
S&F Miniature circuit breaker (MCBs) single pole and Nuetral, 240 Volts, 10KA, 40 Amps, 'C' cure complete all as specified and directed.
S&F surge protection device type 2 AC, TPN , 415V, 50Hz complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or DB's/Indoor type LT PBs or any other indicated situation for loop earthing etc. 4mm dia galvanised iron or steel wire all as specified and directed.
Supply, install test & commmissioning of high wall mounted inverter type split AC ,having indoor and outdoor units with copper tube evaporator & condensing unit of capacity 1.5 Ton capacity complete with cordless remote control unit and with minimum 5 star rated and EER 5.05 with necessary fixing arrangements,drain water pipe upto required length ,stand for outdoor unit ,with 3 core PVC insulated and PVC sheathed copper cable of required size complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stablized at 230 volt with accuracy of 2.5% of capacity 4 KVA complete all as specified and directed.
S&F line copper tube 1/2" bore including insulation of AC pipe complete all as specified and directed
S&F line copper tube 1/4" bore including insulation of AC pipe complete all as specified and directed
Supply, Installing, testing and commissioning factory made and tested LT indoor type, platform mounted / wall mounted, suitable for 415 volts, 3 phase and neutral, 4 wore 50 Hz AC supply system. The panel shall be dust and vermin proof, protection class (IP-54) and made of 2.00 mm thick CRCA sheet, front opening type bottom for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adquated size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of siemens grey shade 7035. The scope of work also comprising of the following:- (i) Control panel for Air conditioning unit is designed to work in two halves. i.e first 12 hour period for 1st and 2nd AC unit and next 12 hour period for 3 rd & 4th AC unit & process vice versa. The panel is capable to cut-off both the AC unit at set or predefined control timer. (ii) The panel manufacturer sholdh have following Govt. approved certificatess. (a) CPRI certification Degree of Protection IP-54 (should have IEC-60439-1 & IEC-60529 tests) (b) CPRI certification short circuit withstand strength should be 50 kArms for 1.0 sec with initial peak of 105kA (c) CPRI certification rated current for shor circuit not less than 4000A with rated insulation voltage 660v. (d) ISO 9001 certified.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
Tender70.pdf
Tender Documents • 1.50 MB
BOQ_837196.xls
BOQ • 1.87 MB
Download all tender documents and submit your bid